Cited by 242Luminescence and Fluorescent MaterialsOptical Imaging and Spectroscopy TechniquesMolecular Sensors and Ion Detection

Semiconducting Polymer Dots with Dual‐Enhanced NIR‐IIa Fluorescence for Through‐Skull Mouse‐Brain Imaging

Zhang, Zhe, Fang, Xiaofeng, Liu, Zhihe, Liu, Haichao, Chen, Dandan, He, Shuqing, Zheng, Jie, Yang, Bing +3 more·2020·Angewandte Chemie International Edition

Abstract

Fluorescence probes in the NIR‐IIa region show drastically improved imaging owing to the reduced photon scattering and autofluorescence in biological tissues. Now, NIR‐IIa polymer dots (Pdots) are developed with a dual fluorescence enhancement mechanism. First, the aggregation induced emission of phenothiazine was used to reduce the nonradiative decay pathways of the polymers in condensed states. Second, fluorescence quenching was minimized by different levels of steric hindrance to further boost the fluorescence. The resulting Pdots displayed a fluorescence QY of ca. 1.7 % in aqueous solution, suggesting an enhancement of ca. 21 times in comparison with the original polymer in tetrahydrofuran (THF) solution. Small‐animal imaging by using the NIR‐IIa Pdots exhibited a remarkable improvement in penetration depth and signal to background ratio, as confirmed by through‐skull and through‐scalp fluorescent imaging of the cerebral vasculature of live mice.

Integrity signals

Registry

Crossref · 10.1002/anie.201914397

Cites

55 of 55 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Zhang, Z., Fang, X., Liu, Z., Liu, H., Chen, D., He, S., Zheng, J., Yang, B., Qin, W., Zhang, X., & Wu, C.
Affiliations
  • Jilin University (CN)
  • Southern University of Science and Technology (CN)
  • University of Macau (MO)
Corresponding author
Wu, Changfeng
Venue
Angewandte Chemie International Edition
Publisher
Wiley
Published
2020-01-21
Volume
59
Issue
9
Pages
3691-3698
ISSN
  • 1433-7851 (ISSN-L)
  • 1521-3773
OpenAlex
W2994821582
Cited by
242
References
55
Citations by year
2026: 16 · 2025: 27 · 2024: 34 · 2023: 39 · 2022: 41 · 2021: 51 · 2020: 34
FWCI
11.35
Type
journal article
Language
en
Open access
closed
Locations
  • Angewandte Chemie International Edition (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Science, Technology and Innovation Commission of Shenzhen Municipality (JCYJ20170307110157501)
  • National Natural Science Foundation of China (81771930)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
Keywords
semiconducting polymer dots, neuroimaging, aggregation-induced emission, phenothiazines, fluorescence quenching, steric hindrance, fluorescence quantum yield enhancement, cerebral vasculature, small animal imaging
MeSH terms
Animals, Bone and Bones, Brain, Fluorescent Dyes, Furans, Polymers, Quantum Theory, Semiconductors, Spectroscopy, Near-Infrared, Quantum Dots, Mice

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review