Stable, Bright, and Long-Fluorescence-Lifetime Dyes for Deep-Near-Infrared Bioimaging
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Near-infrared (NIR) fluorophores absorbing maximally in the region beyond 800 nm, i.e., deep-NIR spectral region, are actively sought for biomedical applications. Ideal dyes are bright, nontoxic, photostable, biocompatible, and easily derivatized to introduce functionalities (e.g., for bioconjugation or aqueous solubility). The rational design of such fluorophores remains a major challenge. Silicon-substituted rhodamines have been successful for bioimaging applications in the red spectral region. The longer-wavelength silicon-substituted congeners for the deep-NIR spectral region are unknown to date. We successfully prepared four silicon-substituted bis-benzannulated rhodamine dyes ( ESi5a–ESi5d ), with an efficient five-step cascade on a gram-scale. Because of the extensive overlapping of their HOMO–LUMO orbitals, ESi5a–ESi5d are highly absorbing (λ abs ≈ 865 nm and ε > 10 5 cm –1 M –1 ). By restraining both the rotational freedom via annulation and the vibrational freedom via silicon-imparted strain, the fluorochromic scaffold of ESi5 is highly rigid, resulting in an unusually long fluorescence lifetime (τ > 700 ps in CH 2 Cl 2 ) and a high fluorescence quantum yield (ϕ = 0.14 in CH 2 Cl 2 ). Their half-lives toward photobleaching are 2 orders of magnitude longer than the current standard (ICG in serum). They are stable in the presence of biorelevant concentration of nucleophiles or reactive oxygen species. They are minimally toxic and readily metabolized. Upon tail vein injection of ESi5a (as an example), the vasculature of a nude mouse was imaged with a high signal-to-background ratio. ESi5 dyes have broad potentials for bioimaging in the deep-NIR spectral region.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new mixing of Hartree–Fock and local density-functional theories
Becke, A. D. (1993) · The Journal of Chemical Physics · doi:10.1063/1.464304 · Cited by 16,515
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
Self-citationAdvanced Fluorescence Imaging Technology in the Near-Infrared-II Window for Biomedical Applications
Li, C., Chen, G., Zhang, Y., Wu, F., & Wang, Q. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07022 · Cited by 1,037
Carr, J. A., Franke, D., Caram, J. R., Perkinson, C. F., Saif, M., Askoxylakis, V., Datta, M., Fukumura, D., Jain, R. K., Bawendi, M. G., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1718917115 · Cited by 721
Li, B., Lu, L., Zhao, M., Lei, Z., & Zhang, F. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201801226 · Cited by 658
Self-citationAnti-quenching NIR-II molecular fluorophores for in vivo high-contrast imaging and pH sensing
Wang, S., Fan, Y., Li, D., Sun, C., Lei, Z., Lu, L., Wang, T., & Zhang, F. (2019) · Nature Communications · doi:10.1038/s41467-019-09043-x · Cited by 510
Self-citationSheng, Z., Guo, B., Hu, D., Xu, S., Wu, W., Liew, W. H., Yao, K., Jiang, J., Liu, C., Zheng, H., et al. (2018) · Advanced Materials · doi:10.1002/adma.201800766 · Cited by 445
Flavylium Polymethine Fluorophores for Near‐ and Shortwave Infrared Imaging
Cosco, E. D., Caram, J. R., Bruns, O. T., Franke, D., Day, R. A., Farr, E. P., Bawendi, M. G., & Sletten, E. M. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201706974 · Cited by 415
Lei, Z., Sun, C., Pei, P., Wang, S., Li, D., Zhang, X., & Zhang, F. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201904182 · Cited by 362
Self-citationFang, Y., Shang, J., Liu, D., Shi, W., Li, X., & Ma, H. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c08187 · Cited by 223
Cited by
Near infrared fluorescent probes for detecting and imaging active small molecules
Ding, C., & Ren, T. (2023) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2023.215080 · Cited by 247
Ma, D., Bian, H., Gu, M., Wang, L., Chen, X., & Peng, X. (2024) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2024.215677 · Cited by 124
Liu, Y., Ran, X., Zhou, D., Zhang, H., Chen, Y., Xu, J., Chen, S., Kong, Q., Yu, X., & Li, K. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202311365 · Cited by 69
Liu, D., He, Z., Gao, W., Shang, J., Yang, Y., Zhang, X., Li, X., Ma, H., & Shi, W. (2025) · Nature Communications · doi:10.1038/s41467-025-60241-2 · Cited by 32
“Similarto cyanines, xanthene dyes show small Stokes shift due to their symmetric con fi guration 37 .”
Self-citation
Metadata
- Authors
- Li, J., Dong, Y., Wei, R., Jiang, G., Yao, C., Lv, M., Wu, Y., Gardner, S. H., Zhang, F., Lucero, M. Y., Huang, J., Chen, H., Ge, G., Chan, J., Chen, J., Sun, H., Luo, X., Qian, X., & Yang, Y.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2022-07-29
- Volume
- 144
- Issue
- 31
- Pages
- 14351-14362
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W4288714484
- Cited by
- 156
- References
- 22
- FWCI
- 9.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.