The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
An Optofluidic Nanoplasmonic Biosensor for Direct Detection of Live Viruses from Biological Media
Open accessAbstract
Fast and sensitive virus detection techniques, which can be rapidly deployed at multiple sites, are essential to prevent and control future epidemics and bioterrorism threats. In this Letter, we demonstrate a label-free optofluidic nanoplasmonic sensor that can directly detect intact viruses from biological media at clinically relevant concentrations with little to no sample preparation. Our sensing platform is based on an extraordinary light transmission effect in plasmonic nanoholes and utilizes group-specific antibodies for highly divergent strains of rapidly evolving viruses. So far, the questions remain for the possible limitations of this technique for virus detection, as the penetration depths of the surface plasmon polaritons are comparable to the dimensions of the pathogens. Here, we demonstrate detection and recognition of small enveloped RNA viruses (vesicular stomatitis virus and pseudotyped Ebola) as well as large enveloped DNA viruses (vaccinia virus) within a dynamic range spanning 3 orders of magnitude. Our platform, by enabling high signal to noise measurements without any mechanical or optical isolation, opens up opportunities for detection of a broad range of pathogens in typical biology laboratory settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Extraordinary optical transmission through sub-wavelength hole arrays
Ebbesen, T. W., Lezec, H. J., Ghaemi, H. F., Thio, T., & Wolff, P. A. (1998) · Nature · doi:10.1038/35570 · Cited by 7,687
Biosensing with plasmonic nanosensors
Anker, J. N., Hall, W. P., Lyandres, O., Shah, N. C., Zhao, J., & Van Duyne, R. P. (2008) · Nature Materials · doi:10.1038/nmat2162 · Cited by 6,786
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809
Present and future of surface plasmon resonance biosensors
Homola, J. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2101-0 · Cited by 2,321
Nano-optics from sensing to waveguiding
Lal, S., Link, S., & Halas, N. J. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.223 · Cited by 2,138
Translating Biomolecular Recognition into Nanomechanics
Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., -J. Güntherodt, H., Gerber, C., & Gimzewski, J. K. (2000) · Science · doi:10.1126/science.288.5464.316 · Cited by 1,646
Label-Free, Single-Molecule Detection with Optical Microcavities
Armani, A. M., Kulkarni, R. P., Fraser, S. E., Flagan, R. C., & Vahala, K. J. (2007) · Science · doi:10.1126/science.1145002 · Cited by 1,141
Making it stick: convection, reaction and diffusion in surface-based biosensors
Squires, T. M., Messinger, R. J., & Manalis, S. R. (2008) · Nature Biotechnology · doi:10.1038/nbt1388 · Cited by 986
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Shift of whispering-gallery modes in microspheres by protein adsorption
Arnold, S., Khoshsima, M., Teraoka, I., Holler, S., & Vollmer, F. (2003) · Optics Letters · doi:10.1364/ol.28.000272 · Cited by 736
Cited by
Wu, C., Khanikaev, A. B., Adato, R., Arju, N., Yanik, A. A., Altug, H., & Shvets, G. (2012) · Nature Materials · doi:10.1038/nmat3161 · Cited by 1,045
Self-citationDiagnostics for SARS-CoV-2 infections
Kevadiya, B. D., Machhi, J., Herskovitz, J., Oleynikov, M. D., Blomberg, W. R., Bajwa, N., Soni, D., Das, S., Hasan, M., Patel, M., et al. (2021) · Nature Materials · doi:10.1038/s41563-020-00906-z · Cited by 833
Seeing protein monolayers with naked eye through plasmonic Fano resonances
Yanik, A. A., Cetin, A. E., Huang, M., Artar, A., Mousavi, S. H., Khanikaev, A., Connor, J. H., Shvets, G., & Altug, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1101910108 · Cited by 522
Self-citationBiosensor technology: recent advances in threat agent detection and medicine
Kirsch, J., Siltanen, C., Zhou, Q., Revzin, A., & Simonian, A. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60141b · Cited by 462
Advances and challenges in biosensor-based diagnosis of infectious diseases
Sin, M. L., Mach, K. E., Wong, P. K., & Liao, J. C. (2014) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.2014.888313 · Cited by 435
Optical Biosensors Based on Plasmonic Nanostructures: A Review
Spackova, B., Wrobel, P., Bockova, M., & Homola, J. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2624340 · Cited by 421
Advances in Plasmonic Technologies for Point of Care Applications
Tokel, O., Inci, F., & Demirci, U. (2014) · Chemical Reviews · doi:10.1021/cr4000623 · Cited by 407
Handheld high-throughput plasmonic biosensor using computational on-chip imaging
Cetin, A. E., Coskun, A. F., Galarreta, B. C., Huang, M., Herman, D., Ozcan, A., & Altug, H. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.3 · Cited by 354
Self-citationAhmadivand, A., Gerislioglu, B., Ramezani, Z., Kaushik, A., Manickam, P., & Ghoreishi, S. A. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.112971 · Cited by 314
Trends and challenges of refractometric nanoplasmonic biosensors: A review
Estevez, M.-C., Otte, M. A., Sepulveda, B., & Lechuga, L. M. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.10.048 · Cited by 301
The photonic integration of non-solid media using optofluidics
Schmidt, H., & Hawkins, A. R. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.163 · Cited by 298
Optical biosensors: A decade in review
Singh, A. K., Mittal, S., Das, M., Saharia, A., & Tiwari, M. (2023) · Alexandria Engineering Journal · doi:10.1016/j.aej.2022.12.040 · Cited by 292
Point of care testing for infectious diseases
Chen, H., Liu, K., Li, Z., & Wang, P. (2019) · Clinica Chimica Acta · doi:10.1016/j.cca.2019.03.008 · Cited by 270
An Alternative Medical Diagnosis Method: Biosensors for Virus Detection
Saylan, Y., Erdem, Ö., Ünal, S., & Denizli, A. (2019) · Biosensors · doi:10.3390/bios9020065 · Cited by 264
Nanoplasmonic sensors for biointerfacial science
Jackman, J. A., Rahim Ferhan, A., & Cho, N.-J. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00494f · Cited by 258
Koya, A. N., Zhu, X., Ohannesian, N., Yanik, A. A., Alabastri, A., Proietti Zaccaria, R., Krahne, R., Shih, W.-C., & Garoli, D. (2021) · ACS Nano · doi:10.1021/acsnano.0c10945 · Cited by 257
Self-citationXu, X., Peng, B., Li, D., Zhang, J., Wong, L. M., Zhang, Q., Wang, S., & Xiong, Q. (2011) · Nano Letters · doi:10.1021/nl2014982 · Cited by 253
Self-Similar Multiresonant Nanoantenna Arrays for Sensing from Near- to Mid-Infrared
Rodrigo, D., Tittl, A., John-Herpin, A., Limaj, O., & Altug, H. (2018) · ACS Photonics · doi:10.1021/acsphotonics.8b01050 · Cited by 85
Self-citationMiranda, B., Rea, I., Dardano, P., De Stefano, L., & Forestiere, C. (2021) · Biosensors · doi:10.3390/bios11040107 · Cited by 63
Parametric Simulations of Slanted 1D Photonic Crystal Sensors
Breuer-Weil, A., Almasoud, N. N., Abbasi, B., Yetisen, A. K., Yun, S.-H., & Butt, H. (2016) · Nanoscale Research Letters · doi:10.1186/s11671-016-1321-0 · Cited by 11
Metadata
- Authors
- Yanik, A. A., Huang, M., Kamohara, O., Artar, A., Geisbert, T. W., Connor, J. H., & Altug, H.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-11-05
- Volume
- 10
- Issue
- 12
- Pages
- 4962-4969
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2080627425
- Cited by
- 454
- References
- 52
- FWCI
- 14.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.