The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
An Optofluidic Nanoplasmonic Biosensor for Direct Detection of Live Viruses from Biological Media
Open accessAbstract
Fast and sensitive virus detection techniques, which can be rapidly deployed at multiple sites, are essential to prevent and control future epidemics and bioterrorism threats. In this Letter, we demonstrate a label-free optofluidic nanoplasmonic sensor that can directly detect intact viruses from biological media at clinically relevant concentrations with little to no sample preparation. Our sensing platform is based on an extraordinary light transmission effect in plasmonic nanoholes and utilizes group-specific antibodies for highly divergent strains of rapidly evolving viruses. So far, the questions remain for the possible limitations of this technique for virus detection, as the penetration depths of the surface plasmon polaritons are comparable to the dimensions of the pathogens. Here, we demonstrate detection and recognition of small enveloped RNA viruses (vesicular stomatitis virus and pseudotyped Ebola) as well as large enveloped DNA viruses (vaccinia virus) within a dynamic range spanning 3 orders of magnitude. Our platform, by enabling high signal to noise measurements without any mechanical or optical isolation, opens up opportunities for detection of a broad range of pathogens in typical biology laboratory settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Extraordinary optical transmission through sub-wavelength hole arrays
Ebbesen, T. W., Lezec, H. J., Ghaemi, H. F., Thio, T., & Wolff, P. A. (1998) · Nature · doi:10.1038/35570 · Cited by 7,687
Biosensing with plasmonic nanosensors
Anker, J. N., Hall, W. P., Lyandres, O., Shah, N. C., Zhao, J., & Van Duyne, R. P. (2008) · Nature Materials · doi:10.1038/nmat2162 · Cited by 6,786
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809
Present and future of surface plasmon resonance biosensors
Homola, J. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2101-0 · Cited by 2,321
Nano-optics from sensing to waveguiding
Lal, S., Link, S., & Halas, N. J. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.223 · Cited by 2,138
Translating Biomolecular Recognition into Nanomechanics
Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., -J. Güntherodt, H., Gerber, C., & Gimzewski, J. K. (2000) · Science · doi:10.1126/science.288.5464.316 · Cited by 1,646
Label-Free, Single-Molecule Detection with Optical Microcavities
Armani, A. M., Kulkarni, R. P., Fraser, S. E., Flagan, R. C., & Vahala, K. J. (2007) · Science · doi:10.1126/science.1145002 · Cited by 1,141
Making it stick: convection, reaction and diffusion in surface-based biosensors
Squires, T. M., Messinger, R. J., & Manalis, S. R. (2008) · Nature Biotechnology · doi:10.1038/nbt1388 · Cited by 986
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Shift of whispering-gallery modes in microspheres by protein adsorption
Arnold, S., Khoshsima, M., Teraoka, I., Holler, S., & Vollmer, F. (2003) · Optics Letters · doi:10.1364/ol.28.000272 · Cited by 736
Barnes, W. L., Murray, W. A., Dintinger, J., Devaux, E., & Ebbesen, T. W. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.107401 · Cited by 718
Ultra-sensitive vibrational spectroscopy of protein monolayers with plasmonic nanoantenna arrays
Adato, R., Yanik, A. A., Amsden, J. J., Kaplan, D. L., Omenetto, F. G., Hong, M. K., Erramilli, S., & Altug, H. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0907459106 · Cited by 668
Self-citationDrosten, C., Göttig, S., Schilling, S., Asper, M., Panning, M., Schmitz, H., & Günther, S. (2002) · Journal of Clinical Microbiology · doi:10.1128/jcm.40.7.2323-2330.2002 · Cited by 631
Detection Limits for Nanoscale Biosensors
Sheehan, P. E., & Whitman, L. J. (2005) · Nano Letters · doi:10.1021/nl050298x · Cited by 615
Newly Discovered Ebola Virus Associated with Hemorrhagic Fever Outbreak in Uganda
Towner, J. S., Sealy, T. K., Khristova, M. L., Albariño, C. G., Conlan, S., Reeder, S. A., Quan, P.-L., Lipkin, W. I., Downing, R., Tappero, J. W., et al. (2008) · PLoS Pathogens · doi:10.1371/journal.ppat.1000212 · Cited by 599
Potter, C. W. (2001) · Journal of Applied Microbiology · doi:10.1046/j.1365-2672.2001.01492.x · Cited by 584
The viruses and their replication
Lindenbach, B. D. (2007) · Medical Entomology and Zoology · Cited by 553
Principles of biosensing with an extended coupling matrix and surface plasmon resonance
Liedberg, B., Lundström, I., & Stenberg, E. (1993) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(93)85239-7 · Cited by 524
Bunimovich, Y. L., Shin, Y. S., Yeo, W.-S., Amori, M., Kwong, G., & Heath, J. R. (2006) · Journal of the American Chemical Society · doi:10.1021/ja065923u · Cited by 480
Lensfree microscopy on a cellphone
Tseng, D., Mudanyali, O., Oztoprak, C., Isikman, S. O., Sencan, I., Yaglidere, O., & Ozcan, A. (2010) · Lab on a Chip · doi:10.1039/c003477k · Cited by 480
Garbutt, M., Liebscher, R., Wahl-Jensen, V., Jones, S., Möller, P., Wagner, R., Volchkov, V., Klenk, H.-D., Feldmann, H., & Ströher, U. (2004) · Journal of Virology · doi:10.1128/jvi.78.10.5458-5465.2004 · Cited by 381
All-Optical Nanoscale pH Meter
Bishnoi, S. W., Rozell, C. J., Levin, C. S., Gheith, M. K., Johnson, B. R., Johnson, D. H., & Halas, N. J. (2006) · Nano Letters · doi:10.1021/nl060865w · Cited by 346
Quantitative multispectral biosensing and 1D imaging using quasi-3D plasmonic crystals
Stewart, M. E., Mack, N. H., Malyarchuk, V., Soares, J. A. N. T., Lee, T.-W., Gray, S. K., Nuzzo, R. G., & Rogers, J. A. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0606216103 · Cited by 340
Micromechanical Detection of Proteins Using Aptamer-Based Receptor Molecules
Savran, C. A., Knudsen, S. M., Ellington, A. D., & Manalis, S. R. (2004) · Analytical Chemistry · doi:10.1021/ac049859f · Cited by 310
Periodic nanohole arrays with shape-enhanced plasmon resonance as real-time biosensors
Lesuffleur, A., Im, H., Lindquist, N. C., & Oh, S. (2007) · Applied Physics Letters · doi:10.1063/1.2747668 · Cited by 282
Split ring resonator sensors for infrared detection of single molecular monolayers
Cubukcu, E., Zhang, S., Park, Y.-S., Bartal, G., & Zhang, X. (2009) · Applied Physics Letters · doi:10.1063/1.3194154 · Cited by 275
Introduction to Modern Virology
Dimmock, N. J., Easton, A. J., & Leppard, K. N. (1974) · Cited by 274
Leaky and bound modes of surface plasmon waveguides
Zia, R., Selker, M. D., & Brongersma, M. L. (2005) · Physical Review B · doi:10.1103/physrevb.71.165431 · Cited by 229
Electron Microscopy for Rapid Diagnosis of Emerging Infectious Agents1
Hazelton, P. R., & Gelderblom, H. R. (2003) · Emerging infectious diseases · doi:10.3201/eid0903.020327 · Cited by 198
Guiding, Focusing, and Sensing on the Subwavelength Scale Using Metallic Wire Arrays
Shvets, G., Trendafilov, S., Pendry, J. B., & Sarychev, A. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.053903 · Cited by 183
Jones, L. J., Upson, R. H., Haugland, R. P., Panchuk-Voloshina, N., Zhou, M., & Haugland, R. P. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2259 · Cited by 181
Chimeric IgG-binding receptors engineered from staphylococcal protein A and streptococcal protein G.
Eliasson, M., Olsson, A., Palmcrantz, E., Wiberg, K., Inganäs, M., Guss, B., Lindberg, M., & Uhlén, M. (1988) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)68928-8 · Cited by 178
Pathogenesis of Noroviruses, Emerging RNA Viruses
Karst, S. M. (2010) · Viruses · doi:10.3390/v2030748 · Cited by 168
Anomalous resonance in a nanomechanical biosensor
Gupta, A. K., Nair, P. R., Akin, D., Ladisch, M. R., Broyles, S., Alam, M. A., & Bashir, R. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602022103 · Cited by 160
Molecular diagnostics of viral hemorrhagic fevers
Drosten, C., Kümmerer, B. M., Schmitz, H., & Günther, S. (2003) · Antiviral Research · doi:10.1016/s0166-3542(02)00201-2 · Cited by 159
Lefrançois, L., & Lyles, D. S. (1982) · Virology · doi:10.1016/0042-6822(82)90126-x · Cited by 140
Gaydos, C. A., Crotchfelt, K. A., Howell, M. R., Kralian, S., Hauptman, P., & Quinn, T. C. (1998) · The Journal of Infectious Diseases · doi:10.1086/514207 · Cited by 127
Defense against filoviruses used as biological weapons
Bray, M. (2003) · Antiviral Research · doi:10.1016/s0166-3542(02)00200-0 · Cited by 119
The origin and evolution of Ebola and Marburg viruses
Suzuki, Y., & Gojobori, T. (1997) · Molecular Biology and Evolution · doi:10.1093/oxfordjournals.molbev.a025820 · Cited by 108
Diffractometric Detection of Proteins Using Microbead-Based Rolling Circle Amplification
Lee, J., İçöz, K., Roberts, A., Ellington, A. D., & Savran, C. A. (2009) · Analytical Chemistry · doi:10.1021/ac901716d · Cited by 108
Fabry–Pérot nanocavities in multilayered plasmonic crystals for enhanced biosensing
Artar, A., Yanik, A. A., & Altug, H. (2009) · Applied Physics Letters · doi:10.1063/1.3202391 · Cited by 92
Self-citationMeasles Infection of the Central Nervous System
Schneider‐Schaulies, J., ter Meulen, V., & Schneider‐Schaulies, S. (2003) · Journal of NeuroVirology · doi:10.1080/13550280390193993 · Cited by 89
Detection of plant viruses using a surface plasmon resonance via complexing with specific antibodies
Boltovets, P. M., Снопок, Б. А., Boyko, V. R., SHEVCHENKO, T., Dyachenko, N. S., & Shirshov, Y. M. (2004) · Journal of Virological Methods · doi:10.1016/j.jviromet.2004.06.019 · Cited by 72
Real-time detection of airborne viruses on a mass-sensitive device
Lee, J., Jang, J., Akin, D., Savran, C. A., & Bashir, R. (2008) · Applied Physics Letters · doi:10.1063/1.2956679 · Cited by 62
Mid-infrared photothermal heterodyne spectroscopy in a liquid crystal using a quantum cascade laser
Mërtiri, A., JEYS, T. H., Liberman, V., Hong, M., Mertz, J. C., Altug, H., & Erramilli, S. (2012) · Applied Physics Letters · doi:10.1063/1.4737942 · Cited by 57
Self-citationRing-coupled Mach-Zehnder interferometer optimized for sensing
Terrel, M. A., Digonnet, M. J. F., & Fan, S. (2009) · Applied Optics · doi:10.1364/ao.48.004874 · Cited by 57
Measles Virus Infections of the Central Nervous System
Liebert, U. G. (1997) · Intervirology · doi:10.1159/000150544 · Cited by 55
Golden, J. W., & Hooper, J. W. (2008) · Virology · doi:10.1016/j.virol.2008.04.003 · Cited by 49
Extraordinary midinfrared transmission of rectangular coaxial nanoaperture arrays
Yanik, A. A., Wang, X., Erramilli, S., et al. (2008) · Applied Physics Letters · doi:10.1063/1.2973165 · Cited by 43
Self-citationСнопок, Б. А., Kostyukevych, K. V., Rengevych, O. V., Shirshov, Y. M., Venger, E. F., Колесникова, И. Н., & Lugovskoi, E. V. (1998) · Semiconductor Physics Quantum Electronics & Optoelectronics · doi:10.15407/spqeo1.01.121 · Cited by 37
Aligned carbon nanotubes as polarization-sensitive, molecular near-field detectors
Cubukcu, E., Degirmenci, F., Kocabaş, C., Zimmler, M. A., Rogers, J. A., & Capasso, F. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0812217106 · Cited by 35
Hybridized nanocavities as single-polarized plasmonic antennas
Yanik, A. A., Adato, R., Erramilli, S., & Altug, H. (2009) · Optics Express · doi:10.1364/oe.17.020900 · Cited by 27
Self-citation
Cited by
Wu, C., Khanikaev, A. B., Adato, R., Arju, N., Yanik, A. A., Altug, H., & Shvets, G. (2012) · Nature Materials · doi:10.1038/nmat3161 · Cited by 1,045
Self-citationDiagnostics for SARS-CoV-2 infections
Kevadiya, B. D., Machhi, J., Herskovitz, J., Oleynikov, M. D., Blomberg, W. R., Bajwa, N., Soni, D., Das, S., Hasan, M., Patel, M., et al. (2021) · Nature Materials · doi:10.1038/s41563-020-00906-z · Cited by 833
Seeing protein monolayers with naked eye through plasmonic Fano resonances
Yanik, A. A., Cetin, A. E., Huang, M., Artar, A., Mousavi, S. H., Khanikaev, A., Connor, J. H., Shvets, G., & Altug, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1101910108 · Cited by 522
Self-citationBiosensor technology: recent advances in threat agent detection and medicine
Kirsch, J., Siltanen, C., Zhou, Q., Revzin, A., & Simonian, A. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60141b · Cited by 462
Trends and challenges of refractometric nanoplasmonic biosensors: A review
Estevez, M.-C., Otte, M. A., Sepulveda, B., & Lechuga, L. M. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.10.048 · Cited by 301
Metadata
- Authors
- Yanik, A. A., Huang, M., Kamohara, O., Artar, A., Geisbert, T. W., Connor, J. H., & Altug, H.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-11-05
- Volume
- 10
- Issue
- 12
- Pages
- 4962-4969
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2080627425
- Cited by
- 454
- References
- 52
- FWCI
- 14.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.