Risk of Sick Leave Associated with Outdoor Air Supply Rate, Humidification, and Occupant Complaints: Sick Leave and Building Ventilation
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
We analyzed 1994 sick leave for 3,720 hourly employees of a large Massachusetts manufacturer, in 40 buildings with 115 independently ventilated work areas. Corporate records identified building characteristics and IEQ complaints. We rated ventilation as moderate (approximately 25 cfm/person, 12 ls-1) or high (approximately 50 cfm/person, 24 ls-1) outdoor air supply based on knowledge of ventilation systems and CO2 measurements on a subset of work areas, and used Poisson regression to analyze sick leave controlled for age, gender, seniority, hours of non-illness absence, shift, ethnicity, crowding, and type of job (office, technical, or manufacturing worker). We found consistent associations of increased sick leave with lower levels of outdoor air supply and IEQ complaints. Among office workers, the relative risk for short-term sick leave was 1.53 (95% confidence 1.22-1.92) with lower ventilation, and 1.52 (1.18-1.97) in areas with IEQ complaints. The effect of ventilation was independent of IEQ complaints and among those exposed to lower outdoor air supply rates the attributable risk of short-term sick leave was 35%. The cost of sick leave attributable to ventilation at current recommended rates was estimated as $480 per employee per year at Polaroid. These findings suggest that net savings of $400 per employee per year may be obtained with increased ventilation. Thus, currently recommended levels of outdoor air supply may be associated with significant morbidity, and lost productivity on a national scale could be as much as $22.8 billion per year. Additional studies of IEQ impacts on productivity and sick leave, and the mechanisms underlying the apparent association are needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2001) · Statistics for Psychologists · doi:10.4324/9781410605542-11 · Cited by 6,877
Ventilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 2,497
The Effectiveness of Vaccination against Influenza in Healthy, Working Adults
Nichol, K. L., Lind, A., Margolis, K. L., Murdoch, M., McFadden, R., Hauge, M., Magnan, S., & Drake, M. (1995) · New England Journal of Medicine · doi:10.1056/nejm199510053331401 · Cited by 673
Johnston, S. L., Pattemore, P. K., Sanderson, G., Smith, S., Campbell, M. J., Josephs, L. K., Cunningham, A., Robinson, B. S., Myint, S. H., Ward, M. E., et al. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.3.8810601 · Cited by 565
Estimates of Improved Productivity and Health from Better Indoor Environments
Fisk, W. J., & Rosenfeld, A. H. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.t01-1-00002.x · Cited by 549
Wargocki, P., Wyon, D. P., Baik, Y. K., Clausen, G., & Fanger, P. O. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.t01-1-00003.x · Cited by 507
Explaining socioeconomic differences in sickness absence: the Whitehall II Study.
North, F., Syme, S. L., Feeney, A., Head, J., Shipley, M. J., & Marmot, M. G. (1993) · BMJ · doi:10.1136/bmj.306.6874.361 · Cited by 391
Rhinovirus Infections in an Industrial Population: The Occurrence of Illness
Gwaltney, J. M., Hendley, J. O., Simon, G., & Jordan, W. S. (1966) · New England Journal of Medicine · doi:10.1056/nejm196612082752301 · Cited by 338
Non-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature
Mendell, M. J. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00003.x · Cited by 284
Aerosol transmission of rhinovirus colds
Dick, E. C., Jennings, L. C., Mink, K. A., Wartgow, C. D., & Inborn, S. L. (1987) · Journal of Infectious Diseases · doi:10.1093/infdis/156.3.442 · Cited by 280
Cited by
Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104789 · Cited by 1,064
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
“Supportive evidence for the earlier paper (Milton et al., 2000) on short-term sick leave”
BackgroundRudnick, S. N., & Milton, D. K. (2003) · Indoor Air · doi:10.1034/j.1600-0668.2003.00189.x · Cited by 624
Self-citationFisk, W. J. (2000) · Annual Review of Energy and the Environment · doi:10.1146/annurev.energy.25.1.537 · Cited by 557
Wyon, D. P. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00278.x · Cited by 500
Vischer, J. C. (2007) · Stress and Health · doi:10.1002/smi.1134 · Cited by 488
“In addition, researchers are increasingly finding links between employee health and aspects of the physical environment at work such as indoor air quality, ergonomic furniture and lighting (Dilani, 2004; Milton, Glencross, & Walters, 2000; Veitch & Newsham, 2000).”
BackgroundAssociations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462
“These findings of this study are generally consistent with those of Milton et al. (2000), who found a 50% reduction in ventilation rates in offices, with corresponding increases in indoor CO2 concentrations, was associated with a 50% increase in short term absence among the office workers occupying…”
BackgroundResultChapter 5. Risk factors for sick leave - general studies
Allebeck, P., & Mastekaasa, A. (2004) · Scandinavian Journal of Public Health · doi:10.1080/14034950410021853 · Cited by 462
Wargocki, P., Sundell, J., Bischof, W., Brundrett, G., Fanger, P. O., Gyntelberg, F., Hanssen, S. O., Harrison, P., Pickering, A., Seppänen, O., et al. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01145.x · Cited by 418
Zhang, X., Wargocki, P., Lian, Z., & Thyregod, C. (2017) · Indoor Air · doi:10.1111/ina.12284 · Cited by 360
Ten questions concerning well-being in the built environment
Altomonte, S., Allen, J., Bluyssen, P. M., Brager, G., Heschong, L., Loder, A., Schiavon, S., Veitch, J. A., Wang, L., & Wargocki, P. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106949 · Cited by 303
Mendell, M. J., Eliseeva, E. A., Davies, M. M., Spears, M., Lobscheid, A., Fisk, W. J., & Apte, M. G. (2013) · Indoor Air · doi:10.1111/ina.12042 · Cited by 299
Wargocki, P., & Wyon, D. P. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.11.020 · Cited by 290
The relationships between classroom air quality and children’s performance in school
Wargocki, P., Porras-Salazar, J. A., Contreras-Espinoza, S., & Bahnfleth, W. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106749 · Cited by 263
Awada, M., Becerik-Gerber, B., Hoque, S., O'Neill, Z., Pedrielli, G., Wen, J., & Wu, T. (2021) · Building and Environment · doi:10.1016/j.buildenv.2020.107480 · Cited by 262
Santamouris, M., Synnefa, A., Asssimakopoulos, M., Livada, I., Pavlou, K., Papaglastra, M., Gaitani, N., Kolokotsa, D., & Assimakopoulos, V. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2008.04.002 · Cited by 253
Rashid, M., & Zimring, C. (2008) · Environment and Behavior · doi:10.1177/0013916507311550 · Cited by 252
Towards a user-centred theory of the built environment
Vischer, J. C. (2008) · Building Research & Information · doi:10.1080/09613210801936472 · Cited by 251
“Studies in this category may look at precise phenomena, such as the effect of variations in ventilation conditions on amount of sick leave (Milton et al., 2000), or at less easy-to-define relationships, such as patterns of friendship and sociability on an urban street (Appleyard et al., 1981), or…”
BackgroundSummary of human responses to ventilation
Seppanen, O. A., & Fisk, W. J. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00279.x · Cited by 249
“The strongest evidence is provided by the most recent study of these (Milton et al., 2000).”
Kelly, F. J., & Fussell, J. C. (2019) · Atmospheric Environment · doi:10.1016/j.atmosenv.2018.11.058 · Cited by 246
Che, W. W., Tso, C. Y., Sun, L., Ip, D. Y. K., Lee, H., Chao, C. Y. H., & Lau, A. K. H. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.06.029 · Cited by 240
Mendell, M. J., Fisk, W. J., Kreiss, K., Levin, H., Alexander, D., Cain, W. S., Girman, J. R., Hines, C. J., Jensen, P. A., Milton, D. K., et al. (2002) · American Journal of Public Health · doi:10.2105/ajph.92.9.1430 · Cited by 229
Self-citationFisk, W. J., Eliseeva, E. A., & Mendell, M. J. (2010) · Environmental Health · doi:10.1186/1476-069x-9-72 · Cited by 217
“The few documented environmental risk factors for respiratory infections include environmental tobacco smoke [23], wood or biofuel stoves [24], and low building ventilation rates [25].”
BackgroundAzimi, P., & Stephens, B. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.08.025 · Cited by 202
“Regardless, results from the modeling effort herein demonstrate that HVAC filtration can very likely play a role in preventing the transmission of airborne infectious diseases at lower costs than providing an equivalent amount of outdoor air ventilation, as previous studies have typically explored [3,4,6,7].”
Impact of sustainable office buildings on occupant's comfort and productivity
Feige, A., Wallbaum, H., Janser, M., & Windlinger, L. (2013) · Journal of Corporate Real Estate · doi:10.1108/jcre-01-2013-0004 · Cited by 177
Carrer, P., Wargocki, P., Fanetti, A., Bischof, W., De Oliveira Fernandes, E., Hartmann, T., Kephalopoulos, S., Palkonen, S., & Seppänen, O. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.08.011 · Cited by 172
Law, J., Van Baalen, M., Foy, M., Mason, S. S., Mendez, C., Wear, M. L., Meyers, V. E., & Alexander, D. (2014) · Journal of Occupational & Environmental Medicine · doi:10.1097/jom.0000000000000158 · Cited by 168
Benefits and costs of improved IEQ in U.S. offices
Fisk, W. J., Black, D., & Brunner, G. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2011.00719.x · Cited by 162
“The findings of a single study in 40 buildings (Milton et al. 2000) were employed to estimate the quantitative relationship of office VR with short term absence.”
BackgroundDetection of Airborne Rhinovirus and Its Relation to Outdoor Air Supply in Office Environments
Myatt, T. A., Johnston, S. L., Zuo, Z., Wand, M., Kebadze, T., Rudnick, S., & Milton, D. K. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200306-760oc · Cited by 161
“(6) in which lower levels of outdoor air supply in office buildings were associated with increased sick leave.”
BackgroundSelf-citationIrga, P. J., Torpy, F. R., & Burchett, M. D. (2013) · Atmospheric Environment · doi:10.1016/j.atmosenv.2013.04.078 · Cited by 137
Some Quantitative Relations between Indoor Environmental Quality and Work Performance or Health
Seppänen, O. A., & Fisk, W. (2006) · HVAC&R Research · doi:10.1080/10789669.2006.10391446 · Cited by 53
Measuring the productivity impacts of energy-efficiency: The case of high-efficiency buildings
Chatterjee, S., & Ürge-Vorsatz, D. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2021.128535 · Cited by 36
Metadata
- Authors
- MILTON, D. K., GLENCROSS, P. M., & WALTERS, M. D.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2000-12
- Volume
- 10
- Issue
- 4
- Pages
- 212-221
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2020548779
- Cited by
- 364
- References
- 35
- FWCI
- 8.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.