A high-performance brain–computer interface
The DOI matches its Crossref record; 23 of the 26 references it cites were found in a registry or an index.
Abstract
Recent studies have demonstrated that monkeys and humans can use signals from the brain to guide computer cursors. Brain-computer interfaces (BCIs) may one day assist patients suffering from neurological injury or disease, but relatively low system performance remains a major obstacle. In fact, the speed and accuracy with which keys can be selected using BCIs is still far lower than for systems relying on eye movements. This is true whether BCIs use recordings from populations of individual neurons using invasive electrode techniques or electroencephalogram recordings using less- or non-invasive techniques. Here we present the design and demonstration, using electrode arrays implanted in monkey dorsal premotor cortex, of a manyfold higher performance BCI than previously reported. These results indicate that a fast and accurate key selection system, capable of operating with a range of keyboard sizes, is possible (up to 6.5 bits per second, or approximately 15 words per minute, with 96 electrodes). The highest information throughput is achieved with unprecedentedly brief neural recordings, even as recording quality degrades over time. These performance results and their implications for system design should substantially increase the clinical viability of BCIs in humans.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Other discrete (classification-based) BCIs have also typically used directional movements with little temporal variety, which may have limited their accuracy and/or the size of the movement set24,25.”
From High-performance brain-to-text communication via handwriting (2021) · cites this paper as [25]
Citations
Cites
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb01338.x · Cited by 88,486
Elements of Information Theory
Cover, T. M., & Thomas, J. A. (2001) · Wiley eBooks · doi:10.1002/0471200611 · Cited by 36,808
Advances in Neural Information Processing Systems 19
(2007) · The MIT Press eBooks · doi:10.52202/085713 · Cited by 15,539
Elements of Information Theory
Cover, T. M., & Thomas, J. A. (2005) · doi:10.1002/047174882x · Cited by 13,791
Theoretical Neuroscience: Computational and Mathematical Modeling of Neural Systems
Dayan, P., & Abbott, L. F. (2001) · Cited by 4,099
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 1×
“Second, a common concern for BCIs such as ours is that as the electrode implant ages the number of recordable neurons declines, leading to a drop in overall performance 19 .”
BackgroundLearning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761 · cited 2×
“Thehandwasalsonotallowedtomoveuntilthegocuewaspresented,providingaproxyfor thecorticalfunctionofaparalysedsubject 1–3 .”
BackgroundDirect Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
Research works printed but not linked: 2
- Hochberg, L. R., Mukand, J., Polykoff, G., Friehs, G. & Donoghue, J. Braingate Neuromotor Prosthesis: Nature and Use of Neural Control Signals. Program No. 520.17, 2005 Abstract Viewer/Itinerary Planner (Society for Neuroscience, Washington DC, 2005)
- Batista, A. et al. Heterogeneous Coordinate Frames for Reaching in Macaque PMd. Program No. 363.12, 2005 Abstract Viewer/Itinerary Planner (Society for Neuroscience, Washington DC, 2005)
Cited by
Items 101–200 of 702
Rapid control and feedback rates enhance neuroprosthetic control
Shanechi, M. M., Orsborn, A. L., Moorman, H. G., Gowda, S., Dangi, S., & Carmena, J. M. (2017) · Nature Communications · doi:10.1038/ncomms13825 · Cited by 120
Sensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121
“For discrete selection, monkeys choose a reach target position/direction from a finite list of options (21, 22).”
Behavioral Demonstration of a Somatosensory Neuroprosthesis
Berg, J. A., Dammann, J. F., Tenore, F. V., Tabot, G. A., Boback, J. L., Manfredi, L. R., Peterson, M. L., Katyal, K. D., Johannes, M. S., Makhlin, A., et al. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2244616 · Cited by 119
Power-saving design opportunities for wireless intracortical brain–computer interfaces
Even-Chen, N., Muratore, D. G., Stavisky, S. D., Hochberg, L. R., Henderson, J. M., Murmann, B., & Shenoy, K. V. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0595-9 · Cited by 118
Self-citationShanechi, M. M., Orsborn, A. L., & Carmena, J. M. (2016) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1004730 · Cited by 113
Prediction of upper limb muscle activity from motor cortical discharge during reaching
Pohlmeyer, E. A., Solla, S. A., Perreault, E. J., & Miller, L. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/003 · Cited by 118
Advances in Neuroprosthetic Learning and Control
Carmena, J. M. (2013) · PLoS Biology · doi:10.1371/journal.pbio.1001561 · Cited by 117
Jarosiewicz, B., Masse, N. Y., Bacher, D., Cash, S. S., Eskandar, E., Friehs, G., Donoghue, J. P., & Hochberg, L. R. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046012 · Cited by 104
DESIGN OF ASSISTIVE WHEELCHAIR SYSTEM DIRECTLY STEERED BY HUMAN THOUGHTS
LI, J., LIANG, J., ZHAO, Q., LI, J., HONG, K., & ZHANG, L. (2013) · International Journal of Neural Systems · doi:10.1142/s0129065713500135 · Cited by 114
Factor-Analysis Methods for Higher-Performance Neural Prostheses
Santhanam, G., Yu, B. M., Gilja, V., Ryu, S. I., Afshar, A., Sahani, M., & Shenoy, K. V. (2009) · Journal of Neurophysiology · doi:10.1152/jn.00097.2009 · Cited by 116
Self-citationContinuous neuronal ensemble control of simulated arm reaching by a human with tetraplegia
Chadwick, E. K., Blana, D., Simeral, J. D., Lambrecht, J., Kim, S. P., Cornwell, A. S., Taylor, D. M., Hochberg, L. R., Donoghue, J. P., & Kirsch, R. F. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/034003 · Cited by 109
A cognitive neuroprosthetic that uses cortical stimulation for somatosensory feedback
Klaes, C., Shi, Y., Kellis, S., Minxha, J., Revechkis, B., & Andersen, R. A. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056024 · Cited by 110
Luu, T. P., He, Y., Brown, S., Nakagome, S., & Contreras-Vidal, J. L. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036006 · Cited by 123
Liu, X., Zhang, M., Richardson, A. G., Lucas, T. H., & Van der Spiegel, J. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2622738 · Cited by 109
Dissecting Biological and Synthetic Soft–Hard Interfaces for Tissue-Like Systems
Fang, Y., Yang, X., Lin, Y., Shi, J., Promiński, A., Clayton, C., Ostroff, E., & Tian, B. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00365 · Cited by 114
Optimizing the Decoding of Movement Goals from Local Field Potentials in Macaque Cortex
Markowitz, D. A., Wong, Y. T., Gray, C. M., & Pesaran, B. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.4165-11.2011 · Cited by 110
“More recent work using 96- electrode Utah arrays in dorsal premotor cortex found that 1-of-8 movement goals were correctly decoded from spiking activity on up to 69% or 77% of trials, depending on the duration of the trial, and hence, the decoding analysis window (Santhanam et al., 2006).”
BackgroundMethodState-of-the-art non-invasive brain–computer interface for neural rehabilitation: A review
Zhuang, M., Wu, Q., Wan, F., & Hu, Y. S. (2020) · Journal of Neurorestoratology · doi:10.26599/jnr.2020.9040001 · Cited by 118
Invasive or Noninvasive: Understanding Brain-Machine Interface Technology [Conversations in BME
del R. Milan, J., & Carmena, J. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2009.935475 · Cited by 100
Predicting Reaching Targets from Human EEG
Hammon, P. S., Makeig, S., Howard Poizner, A., Todorov, E. V., & de Sa, V. R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408443 · Cited by 109
Extraction of Network Topology From Multi-Electrode Recordings: Is there a Small-World Effect?
Gerhard, F., Pipa, G., Lima, B., Neuenschwander, S., & Gerstner, W. (2011) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2011.00004 · Cited by 114
Pu, X., Tang, Q., Chen, W., Huang, Z., Liu, G., Zeng, Q., Chen, J., Guo, H., Xin, L., & Hu, C. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105047 · Cited by 106
Review: Human Intracortical Recording and Neural Decoding for Brain–Computer Interfaces
Brandman, D. M., Cash, S. S., & Hochberg, L. R. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2677443 · Cited by 103
Weber, D. J., London, B. M., Hokanson, J. A., Ayers, C. A., Gaunt, R. A., Torres, R. R., Zaaimi, B., & Miller, L. E. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163145 · Cited by 100
Asynchronous Decoding of Dexterous Finger Movements Using M1 Neurons
Aggarwal, V., Acharya, S., Tenore, F., Shin, H.-C., Etienne-Cummings, R., Schieber, M. H., & Thakor, N. V. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.916289 · Cited by 99
Human cortical prostheses: lost in translation?
Ryu, S. I., & Shenoy, K. V. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0987 · Cited by 104
Self-citationEEG-based asynchronous BCI control of a car in 3D virtual reality environments
Zhao, Q., Zhang, L., & Cichocki, A. S. (2009) · Chinese Science Bulletin · doi:10.1007/s11434-008-0547-3 · Cited by 117
Design and analysis of closed-loop decoder adaptation algorithms for brain-machine interfaces
Dangi, S., Orsborn, A. L., Moorman, H. G., & Carmena, J. M. (2013) · Neural Computation · doi:10.1162/neco_a_00460 · Cited by 103
Christie, B. P., Tat, D. M., Irwin, Z. T., Gilja, V., Nuyujukian, P., Foster, J. D., Ryu, S. I., Shenoy, K. V., Thompson, D. E., & Chestek, C. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016009 · Cited by 103
“We used Naïve Bayes classification as a discrete neural decoder to calculate how accurately we could predict target selection [7].”
MethodSelf-citationA Bayesian approach for inferring neuronal connectivity from calcium fluorescent imaging data
Mishchenko, Y., Vogelstein, J. T., & Paninski, L. (2011) · The Annals of Applied Statistics · doi:10.1214/09-aoas303 · Cited by 122
Neural stimulation and recording performance in human sensorimotor cortex over 1500 days
Hughes, C. L., Flesher, S. N., Weiss, J. M., Downey, J. E., Boninger, M., Collinger, J. L., & Gaunt, R. A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac18ad · Cited by 96
Efficient Decoding With Steady-State Kalman Filter in Neural Interface Systems
Malik, W. Q., Truccolo, W., Brown, E. N., & Hochberg, L. R. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2092443 · Cited by 101
Hauschild, M., Mulliken, G. H., Fineman, I., Loeb, G. E., & Andersen, R. A. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1215092109 · Cited by 96
He, T., & Lee, C. (2021) · IEEE Open Journal of Circuits and Systems · doi:10.1109/ojcas.2021.3123272 · Cited by 103
Grasp Movement Decoding from Premotor and Parietal Cortex
Townsend, B. R., Subasi, E., & Scherberger, H. (2011) · Journal of Neuroscience · doi:10.1523/jneurosci.2451-11.2011 · Cited by 102
Electronic and Ionic Materials for Neurointerfaces
Ferro, M. D., & Melosh, N. A. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201704335 · Cited by 96
Shanechi, M. M., Hu, R. C., Powers, M., Wornell, G. W., Brown, E. N., & Williams, Z. M. (2012) · Nature Neuroscience · doi:10.1038/nn.3250 · Cited by 96
A system for neural recording and closed-loop intracortical microstimulation in awake rodents.
Venkatraman, S., Elkabany, K., Long, J. D., Yao, Y., & Carmena, J. M. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005944 · Cited by 96
Intracortical Recording Interfaces: Current Challenges to Chronic Recording Function
Gunasekera, B., Saxena, T., Bellamkonda, R., & Karumbaiah, L. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn5002864 · Cited by 93
From thought to action: The brain–machine interface in posterior parietal cortex
Andersen, R. A., Aflalo, T., & Kellis, S. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1902276116 · Cited by 94
A 130-$\mu$W, 64-Channel Neural Spike-Sorting DSP Chip
Karkare, V., Gibson, S., & Markovic, D. M. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2116410 · Cited by 106
Localization of neurosurgically implanted electrodes via photograph–MRI–radiograph coregistration
Dalal, S. S., Edwards, E., Kirsch, H. E., Barbaro, N. M., Knight, R. T., & Nagarajan, S. S. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.06.028 · Cited by 92
Xie, X., Rieth, L. W., Caldwell, R., Negi, S., Bhandari, R., Sharma, R., Tathireddy, P., & Solzbacher, F. (2015) · Biomedical Microdevices · doi:10.1007/s10544-014-9904-y · Cited by 91
Explant Analysis of Utah Electrode Arrays Implanted in Human Cortex for Brain-Computer-Interfaces
Woeppel, K., Hughes, C., Herrera, A. J., Eles, J. R., Tyler-Kabara, E. C., Gaunt, R. A., Collinger, J. L., & Cui, X. T. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.759711 · Cited by 90
The Emergence of Single Neurons in Clinical Neurology
Cash, S. S., & Hochberg, L. R. (2015) · Neuron · doi:10.1016/j.neuron.2015.03.058 · Cited by 87
Visual Guidance in Control of Grasping
Janssen, P., & Scherberger, H. (2015) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-071714-034028 · Cited by 92
Decoding M1 Neurons During Multiple Finger Movements
Hamed, S. B., Schieber, M. H., & Pouget, A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00760.2006 · Cited by 87
Information Systems Opportunities in Brain–Machine Interface Decoders
Kao, J. C., Stavisky, S. D., Sussillo, D., Nuyujukian, P., & Shenoy, K. V. (2014) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2307357 · Cited by 86
Self-citationElectrical Guidance of Human Stem Cells in the Rat Brain
Feng, J.-F., Liu, J., Zhang, L., Jiang, J.-Y., Russell, M., Lyeth, B. G., Nolta, J. A., & Zhao, M. (2017) · Stem Cell Reports · doi:10.1016/j.stemcr.2017.05.035 · Cited by 86
Shanechi, M. M., Williams, Z. M., Wornell, G. W., Hu, R. C., Powers, M. E., & Brown, E. N. (2013) · PLoS ONE · doi:10.1371/journal.pone.0059049 · Cited by 90
Brain-computer interfaces: military, neurosurgical, and ethical perspective
Kotchetkov, I. S., Hwang, B. Y., Appelboom, G., Kellner, C. P., & Connolly, E. S. (2010) · Neurosurgical Focus · doi:10.3171/2010.2.focus1027 · Cited by 86
Methods for estimating neural firing rates, and their application to brain–machine interfaces
Cunningham, J. P., Gilja, V., Ryu, S. I., & Shenoy, K. V. (2009) · Neural Networks · doi:10.1016/j.neunet.2009.02.004 · Cited by 83
Self-citationXie, H. B., Liu, Y., Zhu, Y., Ding, X., Yang, Y., & Guan, J. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1316808111 · Cited by 92
Dynamic Encoding of Movement Direction in Motor Cortical Neurons
Rickert, J., Riehle, A., Aertsen, A., Rotter, S., & Nawrot, M. P. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.5441-08.2009 · Cited by 75
Kao, J. C., Nuyujukian, P., Ryu, S. I., & Shenoy, K. V. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2582691 · Cited by 78
Self-citationA dynamical systems view of motor preparation
Shenoy, K. V., Kaufman, M. T., Sahani, M., & Churchland, M. M. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53355-5.00003-8 · Cited by 80
Self-citationThe science and engineering behind sensitized brain-controlled bionic hands
Pandarinath, C., & Bensmaïa, S. J. (2021) · Physiological Reviews · doi:10.1152/physrev.00034.2020 · Cited by 90
A brain–computer interface method combined with eye tracking for 3D interaction
Lee, E. C., Woo, J. C., Kim, J. H., Whang, M., & Park, K. R. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.05.008 · Cited by 83
Pohlmeyer, E. A., Mahmoudi, B., Geng, S., Prins, N. W., & Sanchez, J. C. (2014) · PLoS ONE · doi:10.1371/journal.pone.0087253 · Cited by 85
Physiological Challenges for Intracortical Electrodes
Groothuis, J., Ramsey, N. F., Ramakers, G. M. J., & Plasse, G. (2013) · Brain stimulation · doi:10.1016/j.brs.2013.07.001 · Cited by 86
Electroencephalogram based brain-computer interface: Applications, challenges, and opportunities
Yadav, H., & Maini, S. (2023) · Multimedia Tools and Applications · doi:10.1007/s11042-023-15653-x · Cited by 85
General-Purpose Filter Design for Neural Prosthetic Devices
Srinivasan, L., Eden, U. T., Mitter, S. K., & Brown, E. N. (2007) · Journal of Neurophysiology · doi:10.1152/jn.01118.2006 · Cited by 75
Schalk, G., & Mellinger, J. (2010) · Springer eBooks · doi:10.1007/978-1-84996-092-2_1 · Cited by 77
Welkenhuysen, M., Andrei, A., Ameye, L., Eberle, W., & Nuttin, B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2166963 · Cited by 85
Milekovic, T., Fischer, J., Pistohl, T., Ruescher, J., Schulze-Bonhage, A., Aertsen, A., Rickert, J., Ball, T., & Mehring, C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/046003 · Cited by 72
Design and validation of a real-time spiking-neural-network decoder for brain–machine interfaces
Dethier, J., Nuyujukian, P., Ryu, S. I., Shenoy, K. V., & Boahen, K. A. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036008 · Cited by 76
Self-citationNeural Decoding of Hand Motion Using a Linear State-Space Model With Hidden States
Wu, W. L., Kulkarni, J. E., Hatsopoulos, N. G., & Paninski, L. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023307 · Cited by 76
Ince, N. F., Gupta, R., Arica, S., Tewfik, A. H., Ashe, J., & Pellizzer, G. (2010) · PLoS ONE · doi:10.1371/journal.pone.0014384 · Cited by 74
Signal Processing Challenges for Neural Prostheses
Linderman, M. D., Santhanam, G., Kemere, C. T., Gilja, V., O’Driscoll, S., Yu, B. M., Afshar, A., Ryu, S. I., Shenoy, K. V., & Meng, T. H. Y. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408439 · Cited by 84
Self-citationBerger, M., Agha, N. S., & Gail, A. (2020) · eLife · doi:10.7554/elife.51322 · Cited by 68
Ästrand, E., Wardak, C., & Hamed, S. B. (2014) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2014.00144 · Cited by 86
Decoding center-out hand velocity from MEG signals during visuomotor adaptation
Bradberry, T. J., Rong, F., & Contreras-Vidal, J. L. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.06.023 · Cited by 76
A freely-moving monkey treadmill model
D Foster, J., Nuyujukian, P., Freifeld, O., Gao, H., Walker, R., I Ryu, S., H Meng, T., Murmann, B., J Black, M., & V Shenoy, K. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/4/046020 · Cited by 71
Self-citationSharma, G., Friedenberg, D. A., Annetta, N. V., Glenn, B., Bockbrader, M. A., Majstorovic, C., Domas, S., Mysiw, W. J., Rezai, A. R., & Bouton, C. E. (2016) · Scientific Reports · doi:10.1038/srep33807 · Cited by 76
Abbott, A. (2006) · Nature · doi:10.1038/442125a · Cited by 73
Yeom, H. G., Kim, J. S., & Chung, C. K. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026006 · Cited by 76
O’Shaughnessy, W. S., Murthy, S. K., Edell, D. J., & Gleason, K. K. (2007) · Biomacromolecules · doi:10.1021/bm070242s · Cited by 71
Decoding and Cortical Source Localization for Intended Movement Direction With MEG
Wang, W., Sudre, G. P., Xu, Y., Kass, R. E., Collinger, J. L., Degenhart, A. D., Bagic, A. I., & Weber, D. J. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00239.2010 · Cited by 71
The “sewing machine” for minimally invasive neural recording
Hanson, T. L., Diaz-Botia, C. A., Kharazia, V., Maharbiz, M. M., & Sabes, P. N. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/578542 · Cited by 66
What limits the performance of current invasive brain machine interfaces?
Baranauskas, G. (2014) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2014.00068 · Cited by 79
Volitional activation of remote place representations with a hippocampal brain–machine interface
Lai, C., Tanaka, S., Harris, T. D., & Lee, A. K. (2023) · Science · doi:10.1126/science.adh5206 · Cited by 72
Robust Neuroprosthetic Control from the Stroke Perilesional Cortex
Gulati, T., Won, S. J., Ramanathan, D. S., Wong, C. C., Bodepudi, A., Swanson, R. A., & Ganguly, K. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.5007-14.2015 · Cited by 67
Volitional control of single cortical neurons in a brain–machine interface
Moritz, C. T., & Fetz, E. E. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025017 · Cited by 70
Dendritic calcium signals in rhesus macaque motor cortex drive an optical brain-computer interface
Trautmann, E. M., O’Shea, D. J., Sun, X., Marshel, J. H., Crow, A., Hsueh, B., Vesuna, S. S., Cofer, L. B., Bohner, G., Allen, W., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23884-5 · Cited by 73
Self-citationHwaidi, J. F., & Chen, T. (2022) · IEEE Access · doi:10.1109/access.2022.3171906 · Cited by 77
Performance sustaining intracortical neural prostheses
Nuyujukian, P., Kao, J. C., Fan, J. M., Stavisky, S. D., Ryu, S. I., & Shenoy, K. V. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/6/066003 · Cited by 66
Self-citationBidirectional brain-computer interfaces
Hughes, C. L., Herrera, A. J., Gaunt, R. A., & Collinger, J. L. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00013-5 · Cited by 81
A Low-Power ECoG/EEG Processing IC With Integrated Multiband Energy Extractor
Zhang, F., Mishra, A., Richardson, A. G., & Otis, B. P. (2011) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2011.2163972 · Cited by 73
Free-paced high-performance brain–computer interfaces
Achtman, N., Afshar, A., Santhanam, G., Yu, B. M., Ryu, S. I., & Shenoy, K. V. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/018 · Cited by 70
Self-citationMoioli, R. C., Nardelli, P. H. J., Barros, M. T., Saad, W., Hekmatmanesh, A., Silva, P. E. G., de Sena, A. S., Dzaferagic, M., Šiljak, H., Leekwijck, W. V., et al. (2021) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2021.3090778 · Cited by 69
Can Electrocorticography (ECoG) Support Robust and Powerful Brain-Computer Interfaces?
Schalk, G. (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00009 · Cited by 82
Converting thoughts into action
Scott, S. H. (2006) · Nature · doi:10.1038/442141a · Cited by 74
Self-recalibrating classifiers for intracortical brain–computer interfaces
Bishop, W., Chestek, C. C., Gilja, V., Nuyujukian, P., Foster, J. D., Ryu, S. I., Shenoy, K. V., & Yu, B. M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026001 · Cited by 60
Self-citationLearning in Closed-Loop Brain–Machine Interfaces: Modeling and Experimental Validation
Héliot, R., Ganguly, K., Jimenez, J., & Carmena, J. M. (2010) · IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics) · doi:10.1109/tsmcb.2009.2036931 · Cited by 61
A cortical–spinal prosthesis for targeted limb movement in paralysed primate avatars
Shanechi, M. M., Hu, R. C., & Williams, Z. M. (2014) · Nature Communications · doi:10.1038/ncomms4237 · Cited by 58
Jeon, M., Cho, J., Kim, Y. K., Jung, D., Yoon, E.-S., Shin, S., & Cho, I.-J. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/2/025010 · Cited by 61
A High-Performance Keyboard Neural Prosthesis Enabled by Task Optimization
Nuyujukian, P., Fan, J. M., Kao, J. C., Ryu, S. I., & Shenoy, K. V. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2354697 · Cited by 60
Self-citationCarpaneto, J., Umiltà, M. A., Fogassi, L., Murata, A., Gallese, V., Micera, S., & Raos, V. (2011) · Neuroscience · doi:10.1016/j.neuroscience.2011.04.062 · Cited by 64
Millán, J. D. R. (2013) · Wiley eBooks · doi:10.1002/9781118628522.ch12 · Cited by 63
Brain–Machine Interface Control Algorithms
Shanechi, M. M. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2639501 · Cited by 61
The effect of chronic intracortical microstimulation on the electrode–tissue interface
Chen, K. H., Dammann, J. F., Boback, J. L., Tenore, F. V., Otto, K. J., Gaunt, R. A., & Bensmaia, S. J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026004 · Cited by 59
Metadata
- Authors
- Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V.
- Affiliations
- Stanford SystemX Alliance (US)
- Stanford Medicine (US)
- Corresponding author
- Shenoy, Krishna V.
- Venue
- Nature
- Published
- 2006-07
- Volume
- 442
- Issue
- 7099
- Pages
- 195-198
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2037547604
- Cited by
- 698
- References
- 26
- Citations by year
- 2026: 13 · 2025: 28 · 2024: 27 · 2023: 21 · 2022: 17 · 2021: 32 · 2020: 35 · 2019: 20 · 2018: 22 · 2017: 28 · 2016: 32 · 2015: 41 · 2014: 51 · 2013: 49 · 2012: 35
- FWCI
- 23.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Funders
- Iran Telecommunication Research Center
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- brain-computer interface, dorsal premotor cortex, neural decoding, cursor control, key selection, information throughput, spinal cord injury, invasive neural recording
- MeSH terms
- Animals, Bionics, Brain, Brain Injuries, Electrodes, Humans, Macaca mulatta, Psychomotor Performance, User-Computer Interface, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.