Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Open accessThe DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index.
Abstract
The pursuit of better atomic clocks has advanced many research areas, providing better quantum state control, new insights in quantum science, tighter limits on fundamental constant variation and improved tests of relativity. The record for the best stability and accuracy is currently held by optical lattice clocks. Here we take an important step towards realizing the full potential of a many-particle clock with a state-of-the-art stable laser. Our 87 Sr optical lattice clock now achieves fractional stability of 2.2 × 10−16 at 1 s. With this improved stability, we perform a new accuracy evaluation of our clock, reducing many systematic uncertainties that limited our previous measurements, such as those in the lattice ac Stark shift, the atoms’ thermal environment and the atomic response to room-temperature blackbody radiation. Our combined measurements have reduced the total uncertainty of the JILA Sr clock to 2.1 × 10−18 in fractional frequency units.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



![Figure 4 The measurement of the 3D1 decay rate. (a) The electronic states used for the decay rate measurement. First, we drive the clock transition and then we use a 200-ns laser pulse to drive the 2.6 μm 3P0→3D1 transition. The 3D1 state decays into the 3P manifold with the branching ratios depicted in the panel. Photons from 3P1→1S0 are collected by a photomultiplier tube (PMT). (b) The sum of photon counts for eight million decay events (black dots), fit with the function y(t)=y0+A{exp[–(t–t0)/τ3P1]–exp[–(t–t0)/τ3D1]} (red curve). Data when the pulse is on is excluded to ensure an unbiased fit. The inset is the error ellipse for the fits of τ3D1 and τ3P1. (c) Lifetime versus atom number. Comparing a constant model of this data with a model that is linear in density (the first-order correction for a density-dependent effect) using an F-test, we find no statistically significant lifetime dependence on density. Error bars represent 1σ fit uncertainties (see Methods). The blue band is the ±1σ confidence interval in the weighted mean of these data.](https://figures.cochat.ai/paper-figures/f28c9fdf8f634e8f945b4ec015e03ac3/systematic-evaluation-of-an-atomic-clock-at-2-1018-total-uncertainty-figure-4.jpg)


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Following the lattice light shift model in Ref. [37], we describe firstand higher-order lattice light shifts in a combined model.”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [37]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“More recently, an accuracy of 2 . 1 × 10 -18 (JILA, Nicholson et al. 2015) has been obtained, equivalent to geopotential differences of 0 . 2 m 2 s -2 , or 2 cm on the geoid.”
From Determination of a high spatial resolution geopotential model using atomic clock comparisons (2017) · cites this paper as Nicholson et al. 2015
The cited source says what the claim attributes to it.
In the citing paper
“In comparison to [24], the uncertainty of Sr2 was reduced owing to an extended investigation of the cold-collision shift and a combined evaluation of the lattice light shifts of different orders, using the model from Ref. [37].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [37]
The cited source says what the claim attributes to it.
In the citing paper
“with the current generation of optical atomic clocks reporting fractional performance below the 10 -17 level 1-5 .”
From Atomic clock performance enabling geodesy below the centimetre level (2018) · cites this paper as [2]
The cited source says what the claim attributes to it.
In the citing paper
“They reach systematic uncertainties of a few 10 -18 , which can be resolved after a mere few hours of measurement with optical lattice clocks based on trapped neutral atoms [2][3][4][5][6].”
From Test of Special Relativity Using a Fiber Network of Optical Clocks (2017) · cites this paper as [4]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences.
C., E. L., & Bevington, P. R. (1972) · Journal of the American Statistical Association · doi:10.2307/2284752 · Cited by 3,534
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Self-citationFrequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Kómár, P., Kessler, E. M., Bishof, M., Jiang, L., Sørensen, A. S., Ye, J., & Lukin, M. D. (2014) · Nature Physics · doi:10.1038/nphys3000 · Cited by 768
Self-citationA sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Kessler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 754
Self-citationSpectroscopy Using Quantum Logic
Schmidt, P. O., Rosenband, T., Langer, C., Itano, W. M., Bergquist, J. C., & Wineland, D. J. (2005) · Science · doi:10.1126/science.1114375 · Cited by 643
Nobel Lecture: Controlling photons in a box and exploring the quantum to classical boundary
Haroche, S. (2013) · Reviews of Modern Physics · doi:10.1103/revmodphys.85.1083 · Cited by 633
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Research works printed but not linked: 3
- Dick, J. G. In Proc 19th Precise Time Time Interval Meet. 133–147 (1987).
- Kimble, H. J. In Proc. XIV Int. Conf. Laser Spectrosc. 80–89 (1999).
- Dick, G., Prestage, J., Greenhall, C. & Maleki, L. In Proc. 22nd Precise Time Time Interval Meet. 487–508 (1990).
Cited by
Items 201–300 of 768
Multipolar Polarizabilities and Hyperpolarizabilities in the Sr Optical Lattice Clock
Porsev, S. G., Safronova, M. S., Safronova, U. I., & Kozlov, M. G. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.063204 · Cited by 32
Self-citationOptical atomic clock interrogation using an integrated spiral cavity laser
Loh, W., Reens, D., Kharas, D., Sumant, A., Belanger, C., Maxson, R., Medeiros, A., Setzer, W., Gray, D. J., DeBry, K., et al. (2025) · Nature Photonics · doi:10.1038/s41566-024-01588-8 · Cited by 43
Quantum resonance catastrophe for conductance through a periodically driven barrier
Thuberg, D., Reyes, S. A., & Eggert, S. (2016) · Physical review. B./Physical review. B · doi:10.1103/physrevb.93.180301 · Cited by 31
“On the other hand, there has been tremendous progress in stabilizing lasers and oscillators using a frequency comb, leading in some cases to world-record accuracy of up to 10−18 [44].”
BackgroundKobayashi, T., Akamatsu, D., Hosaka, K., Inaba, H., Okubo, S., Tanabe, T., Yasuda, M., Onae, A., & Hong, F.-L. (2015) · Optics Express · doi:10.1364/oe.23.020749 · Cited by 36
Koke, S., Kühl, A., Waterholter, T., Raupach, S. M. F., Lopez, O., Cantin, E., Quintin, N., Amy‐Klein, A., Pottie, P.-É., & Grosche, G. (2019) · New Journal of Physics · doi:10.1088/1367-2630/ab5d95 · Cited by 37
Recent developments in fiber-based optical frequency comb and its applications
Xia, W., & Chen, X. (2016) · Measurement Science and Technology · doi:10.1088/0957-0233/27/4/041001 · Cited by 33
Holliman, C. A., Fan, M., Contractor, A., Brewer, S. M., & Jayich, A. M. (2022) · Physical Review Letters · doi:10.1103/physrevlett.128.033202 · Cited by 35
Integrated Polarization-Splitting Grating Coupler for Chip-Scale Atomic Magnetometer
Hu, J., Lu, J., Liang, Z., Liu, L., Wang, W., Zhou, P., & Ye, M. (2022) · Biosensors · doi:10.3390/bios12070529 · Cited by 29
“Atomic devices based on the light–atom interaction mechanism such as atomic clocks [1,2], atomic magnetometers [3,4], nuclear magnetic resonance gyroscopes [5,6], and laser frequency stabilizers [7,8] have experienced rapid development in recent decades.”
BackgroundPark, A. J., Trautmann, J., Šantić, N., Klüsener, V., Heinz, A., Bloch, I., & Blatt, S. (2022) · PRX Quantum · doi:10.1103/prxquantum.3.030314 · Cited by 39
“The cavity resonance frequency can be further fine-tuned by placing it in a temperature-controlled enclosure that is also required to create a well-defined blackbody-radiation environment [53].”
BackgroundChabuda, K., Leroux, I. D., & Demkowicz-Dobrzański, R. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/8/083035 · Cited by 37
Howl, R., Hackermüller, L., Bruschi, D. E., & Fuentes, I. (2017) · Advances in Physics X · doi:10.1080/23746149.2017.1383184 · Cited by 50
Phase-Stable Free-Space Optical Lattices for Trapped Ions
Schmiegelow, C. T., Kaufmann, H., Ruster, T., Schulz, J., Kaushal, V., Hettrich, M., Schmidt‐Kaler, F., & Poschinger, U. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.033002 · Cited by 38
Tanabe, T., Akamatsu, D., Kobayashi, T., Takamizawa, A., Yanagimachi, S., Ikegami, T., Suzuyama, T., Inaba, H., Okubo, S., Yasuda, M., et al. (2015) · Journal of the Physical Society of Japan · doi:10.7566/jpsj.84.115002 · Cited by 28
Continuous Real-Time Tracking of a Quantum Phase Below the Standard Quantum Limit
Shankar, A., Greve, G. P., Wu, B., Thompson, J. K., & Holland, M. (2019) · Physical Review Letters · doi:10.1103/physrevlett.122.233602 · Cited by 34
Rydberg electrometry for optical lattice clocks
Bowden, W., Hobson, R., Huillery, P. H., Gill, P. R., Jones, M. P. A., & Hill, I. R. (2017) · Physical Review A · doi:10.1103/physreva.96.023419 · Cited by 28
Optical atomic clock comparison through turbulent air
Bodine, M. I., Deschênes, J.-D., Khader, I. H., Swann, W. C., Leopardi, H., Beloy, K., Bothwell, T., Brewer, S. M., Bromley, S., Chen, J.-S., et al. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.033395 · Cited by 30
Self-citationQuantum enhanced time synchronisation for communication network
Nande, S. S., Paul, M., Senk, S., Ulbricht, M., Bassoli, R., Fitzek, F. H. P., & Boche, H. (2023) · Computer Networks · doi:10.1016/j.comnet.2023.109772 · Cited by 30
“The fractional frequency uncertainty of optical clocks for a variety of atoms, such as Yb [25], Yb+ [8], Sr [20] and Al+ [3], can reach a low level of 10 − 18 .”
BackgroundActinide ions for testing the spatial α -variation hypothesis
Dzuba, V. A., Safronova, M. S., Safronova, M. S., & Flambaum, V. V. (2015) · Physical Review A · doi:10.1103/physreva.92.060502 · Cited by 29
Self-citationSingle electron relativistic clock interferometer
Bushev, P. A., Cole, J. H., Sholokhov, D., Kukharchyk, N., & Zych, M. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/9/093050 · Cited by 37
Robust optical clock transitions in trapped ions using dynamical decoupling
Aharon, N., Spethmann, N., Leroux, I. D., Schmidt, P. O., & Retzker, A. (2019) · New Journal of Physics · doi:10.1088/1367-2630/ab3871 · Cited by 34
Thirolf, P. G., Seiferle, B., & von der Wense, L. (2019) · Annalen der Physik · doi:10.1002/andp.201800381 · Cited by 35
Towards a 229Th-Based Nuclear Clock
von der Wense, L., Seiferle, B., & Thirolf, P. G. (2018) · Measurement Techniques · doi:10.1007/s11018-018-1337-1 · Cited by 38
“By today, optical lattice clocks are the most precise clocks in the world, approaching a total frequency uncertainty of 10 [16, 17].”
BackgroundLu, B.-K., Sun, Z. G., Yang, T., Lin, Y., Wang, Q., Li, Y., Meng, F., Lin, B.-K., Li, T., & Fang, Z. (2022) · Chinese Physics Letters · doi:10.1088/0256-307x/39/8/080601 · Cited by 33
Transportable optical atomic clocks for use in out-of-the-lab environments
Gellesch, M., Jones, J., Barron, R., Singh, A., Sun, Q., Bongs, K., & Singh, Y. (2020) · Advanced Optical Technologies · doi:10.1515/aot-2020-0023 · Cited by 26
Evaluating Optical Clock Performance for GNSS Positioning
Boldbaatar, E., Grant, D., Choy, S., Zaminpardaz, S., & Holden, L. (2023) · Sensors · doi:10.3390/s23135998 · Cited by 32
“In some cases, clocks were self-tested [49].”
BackgroundLiehl, A., Fehrenbacher, D., Sulzer, P., Leitenstorfer, A., & Seletskiy, D. V. (2017) · Optics Letters · doi:10.1364/ol.42.002050 · Cited by 27
Recent progresses of ultracold two-electron atoms
He, C., Hajiyev, E., Ren, Z., Song, B., & Jo, G.-B. (2019) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/ab153e · Cited by 31
Uncertainty Evaluation of an 171Yb Optical Lattice Clock at NMIJ
Kobayashi, T., Akamatsu, D., Hisai, Y., Tanabe, T., Inaba, H., Suzuyama, T., Hong, F.-L., Hosaka, K., & Yasuda, M. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2870937 · Cited by 31
Quantum superpositions of ‘common-cause’ and ‘direct-cause’ causal structures
Feix, A., & Brukner, Č. (2017) · New Journal of Physics · doi:10.1088/1367-2630/aa9b1a · Cited by 29
“This regime is still quite far from experimental implementation, since the bestmolecule interferometers [35] do not go beyond M 10 amu 5 = , x 10 m 6 D = - , while the best atomic lattice clocks achieve a precision of one part in 10(18) [36].”
BackgroundOptical frequency synthesizer referenced to an ytterbium optical clock
Yao, Y., Li, B., Yang, G. H., Chen, X., Hao, Y., Yu, H., Jiang, Y., & Ma, L.-S. (2020) · Photonics Research · doi:10.1364/prj.409534 · Cited by 26
Coherent fibre link for synchronization of delocalized atomic clocks
Cizek, M., Pravdova, L., Pham, T. M., Lesundak, A., Hrabina, J., Lazar, J., Pronebner, T., Aeikens, E., Premper, J., Havliš, O., et al. (2022) · Optics Express · doi:10.1364/oe.447498 · Cited by 27
Two-Color Grating Magneto-Optical Trap for Narrow-Line Laser Cooling
Bondza, S., Lisdat, C., Kroker, S., & Leopold, T. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.044002 · Cited by 34
Thirolf, P. G., Kraemer, S., Moritz, D., & Scharl, K. (2024) · The European Physical Journal Special Topics · doi:10.1140/epjs/s11734-024-01098-2 · Cited by 39
Porsev, S. G., Kozlov, M. G., Safronova, M. S., & Tupitsyn, I. I. (2016) · Physical Review A · doi:10.1103/physreva.93.012501 · Cited by 25
Self-citationPrecision test of the ac Stark shift in a rubidium atomic vapor
Levi, F., Camparo, J. C., Francois, B., Calosso, C. E., Micalizio, S., & Godone, A. (2016) · Physical Review A · doi:10.1103/physreva.93.023433 · Cited by 25
Kobayashi, T., Akamatsu, D., Nishida, Y., Tanabe, T., Yasuda, M., Hong, F.-L., & Hosaka, K. (2016) · Optics Express · doi:10.1364/oe.24.012142 · Cited by 26
Meta-grating outcouplers for optimized beam shaping in the visible
Ropp, C., Yulaev, A., Westly, D., Simelgor, G., & Aksyuk, V. (2021) · Optics Express · doi:10.1364/oe.424644 · Cited by 30
“This wavelength is used for laser cooling strontium atoms in MOTs and atomic clocks [20,21].”
MethodRealization of Closed-Loop Operation of Optical Lattice Clock Based on 171 Yb
Liu, H., Zhang, X., Jiang, K., Wang, J., Zhu, Q., Xiong, Z.-X., He, L., & Lyu, B. (2017) · Chinese Physics Letters · doi:10.1088/0256-307x/34/2/020601 · Cited by 26
Synthetic frequency protocol for Ramsey spectroscopy of clock transitions
Yudin, V. I., Taǐchenachev, A. V., Basalaev, M. Y., & Zanon-Willette, T. (2016) · Physical Review A · doi:10.1103/physreva.94.052505 · Cited by 29
The Pulsating White Dwarf G117-B15A: Still the Most Stable Optical Clock Known
Kepler, S. O., Winget, D. E., Vanderbosch, Z. P., Castanheira, B. G., Hermes, J. J., Bell, K. J., Mullally, F. R., Romero, A. D., Montgomery, M. H., DeGennaro, S., et al. (2020) · The Astrophysical Journal · doi:10.3847/1538-4357/abc626 · Cited by 26
Why did the apple fall? A new model to explain Einstein’s gravity
Stannard, W., Blair, D. G., Zadnik, M. G., & Kaur, T. (2016) · European Journal of Physics · doi:10.1088/0143-0807/38/1/015603 · Cited by 24
Midinfrared magneto-optical trap of metastable strontium for an optical lattice clock
Hobson, R., Bowden, W., Vianello, A., Hill, I. R., & Gill, P. R. (2020) · Physical Review A · doi:10.1103/physreva.101.013420 · Cited by 25
Hyperfine Averaging by Dynamic Decoupling in a Multi-Ion Lutetium Clock
Kaewuam, R., Tan, T. R., Arnold, K. J., Chanu, S. R., Zhang, Z., & Barrett, M. D. (2020) · Physical Review Letters · doi:10.1103/physrevlett.124.083202 · Cited by 24
“[2] TL Nicholson, SL Campbell, RB Hutson, GE Marti, BJ Bloom, RL McNally, Wei Zhang, MD Barrett, MS Safronova, GF Strouse, et al.”
BackgroundSelf-citationTime Synchronization in Communication Networks: A Comparative Study of Quantum Technologies
Nande, S. S., Garbugli, A., Bassoli, R., & Fitzek, F. H. P. (2024) · IEEE Wireless Communications and Networking Conference · doi:10.1109/wcnc57260.2024.10570688 · Cited by 22
“The energy-level shift due to the lattice potential is minimized by operating the lattice at a “magic wavelength”, where the shifts for both the ground and excited states are equal, thereby canceling out [29], [30].”
BackgroundCao, J. Z., Yuan, J., Wang, S., Zhang, P., Yuan, Y., Liu, D., Cui, K., Chao, S., Shu, H., Lin, Y., et al. (2022) · Applied Physics Letters · doi:10.1063/5.0079432 · Cited by 23
Light propagation and atom interferometry in gravity and dilaton fields
Pumpo, F. D., Friedrich, A., Geyer, A., Ufrecht, C., & Giese, E. (2022) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.105.084065 · Cited by 27
Ultralow noise microwave synthesis via difference frequency division of a Brillouin resonator
Loh, W., Gray, D. J., Irion, R. A., May, O., Belanger, C., Plant, J. J., Juodawlkis, P., & Yegnanarayanan, S. S. (2024) · Optica · doi:10.1364/optica.515321 · Cited by 25
“Such is the case in techniques for feedforward stabilization of ultrastable lasers [3,4], for advanced manipulation of light delivery to atomic systems [5], and for frequency comb generation via electro-optic modulation [6,7].”
MethodRealizing exactly solvable SU(N) magnets with thermal atoms
Beverland, M. E., Alagic, G., Martin, M. J., Koller, A., Rey, A. M., & Gorshkov, A. V. (2016) · Physical Review A · doi:10.1103/physreva.93.051601 · Cited by 27
Cox, K. C., Greve, G. P., Wu, B., & Thompson, J. K. (2016) · Physical Review A · doi:10.1103/physreva.94.061601 · Cited by 25
Lu, X., Guo, F., Wang, Y., Xu, Q., Zhou, C., Xia, J., Wu, W., & Chang, H. (2023) · Metrologia · doi:10.1088/1681-7575/acb05c · Cited by 24
Electric dipole matrix elements for the 6p2PJ→7s2S1/2 transition in atomic cesium
Toh, G., Damitz, A., Glotzbach, N., Quirk, J., Stevenson, I., Choi, J., Safronova, M. S., & Elliott, D. S. (2019) · Physical Review A · doi:10.1103/physreva.99.032504 · Cited by 22
Self-citationGuidelines for developing optical clocks with $10^{-18}$ fractional frequency uncertaintyPreprint
Hafiz, M. A., Ablewski, P., Al-Masoudi, A., Martínez, H. Á., Balling, P., Barwood, G. P., Benkler, E., Bober, M., Borkowski, M., Bowden, W., et al. (2019) · arXiv (Cornell University) · doi:10.15488/5553 · Cited by 44
“Raman scattering P0→ P1 is followed by radiative decay to the ground state, since the state P1 has a lifetime of about 21 μs (Nicholson et al., 2015).”
BackgroundMethodInfluentialAdiabatic control of atomic dressed states for transport and sensing
Cooper, N. R., & Rey, A. M. (2015) · Physical Review A · doi:10.1103/physreva.92.021401 · Cited by 24
An Atomic Sensor for Direct Detection of Weak Microwave Signals
Gerginov, V. P., da Silva, F. C. S., Hati, A., & Nelson, C. W. (2019) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2019.2921351 · Cited by 22
“Atomic clock accuracies reach 18 digits of precision [1]–[3], enabled through sensitive probing of atomic transitions.”
BackgroundDevelopment of a strontium optical lattice clock for the SOC mission on the ISS
Origlia, S., Schiller, S., Pramod, M. S., Smith, L., Singh, Y., He, W., Viswam, S., Świerad, D., Hughes, J., Bongs, K., et al. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2229473 · Cited by 34
Ultra-stability Yb-doped fiber optical frequency comb with 2 × 10^−18/s stability in-loop
Pang, L., Han, H., Zhao, Z., Liu, W., & Wei, Z. (2016) · Optics Express · doi:10.1364/oe.24.028993 · Cited by 22
Quantum complementarity of clocks in the context of general relativity
Zhou, Z., Margalit, Y., Rohrlich, D., Japha, Y., & Folman, R. (2018) · Classical and Quantum Gravity · doi:10.1088/1361-6382/aad56b · Cited by 21
Galland, N., Lučić, N., Zhang, S., Martínez, H. Á., Targat, R. L., Ferrier, A., Goldner, P., Fang, B., Seidelin, S. L., & Coq, Y. L. (2020) · Optics Letters · doi:10.1364/ol.389833 · Cited by 26
Faraday-Shielded dc Stark-Shift-Free Optical Lattice Clock
Beloy, K., Zhang, X., McGrew, W. F., Hinkley, N., Yoon, T. H., Nicolodi, D., Fasano, R. J., Schäffer, S. A., Brown, R. C., & Ludlow, A. D. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.183201 · Cited by 20
Compact magneto-optical trap of thulium atoms for a transportable optical clock
Golovizin, A. A., Tregubov, D. O., Mishin, D., Provorchenko, D. I., & Kolachevsky, N. (2021) · Optics Express · doi:10.1364/oe.435105 · Cited by 21
State-Insensitive Trapping of Alkaline-Earth Atoms in a Nanofiber-Based Optical Dipole Trap
Kestler, G., Ton, K., Filin, D., Cheung, C., Schneeweiß, P., Hoinkes, T., Volz, J., Safronova, M. S., Rauschenbeutel, A., & Barreiro, J. T. (2023) · PRX Quantum · doi:10.1103/prxquantum.4.040308 · Cited by 22
Self-citationA low noise optical frequency synthesizer at 700–990 nm
Yao, Y., Jiang, Y., Wu, L., Yu, H., Bi, Z., & Ma, L.-S. (2016) · Applied Physics Letters · doi:10.1063/1.4963690 · Cited by 21
Time keeping and searching for new physics using metastable states of Cu, Ag, and Au
Dzuba, V. A., Allehabi, S. O., Flambaum, V. V., Li, J., & Schiller, S. (2021) · Physical Review A · doi:10.1103/physreva.103.022822 · Cited by 26
Simultaneous preparation of two initial clock states in a thulium optical clock
Fedorova, E. S., Golovizin, A. A., Tregubov, D. O., Mishin, D., Provorchenko, D. I., Сорокин, В. Н., Khabarova, K. Y., & Kolachevsky, N. (2020) · Physical Review A · doi:10.1103/physreva.102.063114 · Cited by 21
Optical-lattice-based Cs active clock with a continual superradiant lasing signal
Pan, D., Arora, B., Yu, Y., Sahoo, B. K., & Chen, J. (2020) · Physical Review A · doi:10.1103/physreva.102.041101 · Cited by 22
Circulating pulse cavity enhancement as a method for extreme momentum transfer atom interferometry
Nourshargh, R., Lellouch, S., Hedges, S., Langlois, M., Bongs, K., & Holynski, M. (2021) · Communications Physics · doi:10.1038/s42005-021-00754-6 · Cited by 22
“. With a beam to cloud diameter ratio of 20, residual intensity variations have a negligible contribution to fidelity loss. A typical cloud of radius of 200 m would require a 1=e2 beam radius of 4 mm (42), and a total input power of 1.1 W (31,35). However, divergence of the Gaussian beam over the 1 km arm length is the…”
BackgroundInfluentialS01−P23 magnetic quadrupole transition in neutral strontium
Trautmann, J., Yankelev, D., Klüsener, V., Park, A. J., Bloch, I., & Blatt, S. (2023) · Physical Review Research · doi:10.1103/physrevresearch.5.013219 · Cited by 24
A transportable optical lattice clock at the National Time Service Center*
Kong, D., Wang, Z., Guo, F., Zhang, Q., Lu, X., Wang, Y., & Chang, H. (2020) · Chinese Physics B · doi:10.1088/1674-1056/ab9290 · Cited by 21
Liang, D., Zhang, H., Cai, Y., Liu, K., & Zhang, K. (2021) · Remote Sensing · doi:10.3390/rs13050981 · Cited by 19
Universality-of-clock-rates test using atom interferometry with T3 scaling
Pumpo, F. D., Friedrich, A., Ufrecht, C., & Giese, E. (2023) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.107.064007 · Cited by 24
Kajita, M. (2017) · Physical Review A · doi:10.1103/physreva.95.023418 · Cited by 19
Quantum stopwatch: how to store time in a quantum memory
Yang, Y., Chiribella, G., & Hayashi, M. (2018) · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rspa.2017.0773 · Cited by 26
“[12] Nicholson T, Campbell S, Hutson R, Marti G, Bloom B, McNally R, Zhang W, Barrett M, Safronova M, Strouse G et al.”
BackgroundMethodPhotovoltaic Effect of Atomtronics Induced by an Artificial Gauge Field
Lai, W., Ma, Y.-Q., Zhuang, L., & Liu, W. (2019) · Physical Review Letters · doi:10.1103/physrevlett.122.223202 · Cited by 21
Huang, Y., Guan, H., Bian, W., Ma, L., Liang, K., Li, T., & Gao, K. (2017) · Applied Physics B · doi:10.1007/s00340-017-6731-x · Cited by 21
Nauta, J., Borodin, A. M., Ledwa, H. B., Stark, J., Schwarz, M., Schmöger, L., Micke, P., López-Urrutia, J. R. C., & Pfeifer, T. (2017) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2017.04.077 · Cited by 22
Progress on the 40Ca+ ion optical clock*
Zhang, B., Huang, Y., Zhang, H., Hao, Y., Zeng, M., Guan, H., & Gao, K. (2020) · Chinese Physics B · doi:10.1088/1674-1056/ab9432 · Cited by 20
Zhang, P., Zhang, Y., Li, M., Rao, B., Yan, L., Chen, F., Zhang, X.-F., Chen, Q., Jiang, H., & Zhang, S. (2021) · Chinese Physics B · doi:10.1088/1674-1056/ac40f6 · Cited by 19
Field deployable atomics package for an optical lattice clock
Kale, Y. B., Singh, A. K., Gellesch, M., Jones, J. M., Morris, D. C., Aldous, M., Bongs, K., & Singh, Y. (2022) · Quantum Science and Technology · doi:10.1088/2058-9565/ac7b40 · Cited by 21
Post-Newtonian reference ellipsoid for relativistic geodesy
Kopeikin, S. M., Han, W.-B., & Михайловна, М. Е. (2016) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.93.044069 · Cited by 18
“1 × 10−18 [40] which enables their use for relativistic geodesy at an absolute level of one centimetre.”
BackgroundBreaking the Femtosecond Barrier in Multi-Kilometer Timing Synchronization Systems
Xin, M., Şafak, K., Peng, M. Y., Kalaydzhyan, A., Callahan, P. T., Wang, W., Mücke, O. D., & Käertner, F. X. (2016) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2016.2614676 · Cited by 19
Zanon-Willette, T., Lefèvre, R., Taǐchenachev, A. V., & Yudin, V. I. (2017) · Physical Review A · doi:10.1103/physreva.96.023408 · Cited by 23
Development of 8-branch Er:fiber frequency comb for Sr and Yb optical lattice clocks
Hisai, Y., Akamatsu, D., Kobayashi, T., Okubo, S., Inaba, H., Hosaka, K., Yasuda, M., & Hong, F.-L. (2019) · Optics Express · doi:10.1364/oe.27.006404 · Cited by 22
Cold atom clocks and their applications in precision measurements*
Dai, S., Zheng, F., Liu, K., Chen, W., Lin, Y., Li, T., & Fang, F. (2020) · Chinese Physics B · doi:10.1088/1674-1056/abbbee · Cited by 24
A compact sub-hertz linewidth Fabry Perot cavity frequency stabilized laser for space application
Liu, J., Liu, T., Chen, L. F., Zhang, L., Xu, G., Jiao, D., & Zhang, S. (2020) · Optics & Laser Technology · doi:10.1016/j.optlastec.2020.106777 · Cited by 22
Dipole-Dipole Frequency Shifts in Multilevel Atoms
Cidrim, A., Orioli, A. P., Sanner, C., Hutson, R. B., Ye, J., Bachelard, R., & Rey, A. M. (2021) · Physical Review Letters · doi:10.1103/physrevlett.127.013401 · Cited by 21
Self-citationOptical atomic clocks: defining the future of time and frequency metrology
Fortier, T. M., Luiten, A. N., & Margolis, H. S. (2025) · Optica · doi:10.1364/optica.575770 · Cited by 43
Mi, X., Zhang, B., El‐Mowafy, A., Wang, K., & Yuan, Y. (2022) · GPS Solutions · doi:10.1007/s10291-022-01363-8 · Cited by 18
Laser spectroscopy of cold molecules
Borri, S., & Santambrogio, G. (2016) · Advances in Physics X · doi:10.1080/23746149.2016.1203732 · Cited by 22
How to use the Sun–Earth Lagrange points for fundamental physics and navigation
Tartaglia, A., Lorenzini, E. C., Lucchesi, D. M., Pucacco, G., Ruggiero, M. L., & Valko, P. (2017) · General Relativity and Gravitation · doi:10.1007/s10714-017-2332-6 · Cited by 17
Evaluation of laser frequency offset locking using an electrical delay line
Hisai, Y., Ikeda, K., Sakagami, H., Horikiri, T., Kobayashi, T., Yoshii, K., & Hong, F.-L. (2018) · Applied Optics · doi:10.1364/ao.57.005628 · Cited by 21
An extended-cavity diode laser at 497 nm for laser cooling and trapping of neutral strontium
Schkolnik, V., Fartmann, O., & Krutzik, M. (2019) · Laser Physics · doi:10.1088/1555-6611/aaffc8 · Cited by 21
Annexing magic and tune-out wavelengths to the clock transitions of the alkaline-earth-metal ions
Kaur, J., Sehra, S. S., Arora, B., & Sahoo, B. K. (2017) · Physical Review A · doi:10.1103/physreva.95.042501 · Cited by 17
A proof-of-concept model of compact and high-performance 87Sr optical lattice clock for space
Guo, F., Tan, W., Zhou, C.-H., Xia, J., Chen, Y.-X., Liang, T., Liu, Q., Liu, Y., He, D.-J., Zhou, Y.-Z., et al. (2021) · AIP Advances · doi:10.1063/5.0064087 · Cited by 16
Advances in Laser Linewidth Measurement Techniques: A Comprehensive Review
Liu, Z., Zheng, H., Li, C., Qi, Z., Zhang, C., Li, T., & Bai, Z. (2025) · Micromachines · doi:10.3390/mi16090990 · Cited by 19
“In the field of atomic clocks [111–118], precise linewidth characterization supports the realization of enhanced temporal and frequency standards, which hold critical importance for satellite navigation and high-speed communication systems.”
Satellite-based positioning enhanced by quantum synchronization
Nande, S. S., Rossi, T., Habibie, M. I., Barhoumi, M., Palaparthy, K., Mansouri, W., Raju, A., Bassoli, R., Cianca, E., Fitzek, F. H. P., et al. (2024) · Computer Networks · doi:10.1016/j.comnet.2024.110734 · Cited by 17
Current Trends and Advances in Quantum Navigation for Maritime Applications: A Comprehensive Review
Sambataro, O., Costanzi, R., Alves, J., Caiti, A., Paglierani, P., Petroccia, R., & Munafò, A. (2025) · IEEE Journal of Oceanic Engineering · doi:10.1109/joe.2025.3538941 · Cited by 20
“This schema makes it possible to image objects at extremely low light levels, and it has been demonstrated in cases where infrared light can penetrate with a better SNR [110].”
Cryogenic Optical Lattice Clock with 1.7 × 10 − 20 Blackbody Radiation Stark Uncertainty
Hassan, Y. S., Beloy, K., Siegel, J. L., Kobayashi, T., Swiler, E., Grogan, T., Brown, R. C., Rojo, T., Bothwell, T., Hunt, B. D., et al. (2025) · Physical Review Letters · doi:10.1103/4tky-jmsm · Cited by 30
Prospects for a polar-molecular-ion optical probe of varying proton-electron mass ratio
Kokish, M., Stollenwerk, P., Kajita, M., & Odom, B. (2018) · Physical Review A · doi:10.1103/physreva.98.052513 · Cited by 17
Porsev, S. G., & Safronova, M. S. (2020) · Physical Review A · doi:10.1103/physreva.102.012811 · Cited by 17
Self-citationOptical Atomic Clocks for Redefining SI Units of Time and Frequency
Sharma, L., Rathore, H. K., Utreja, S., Neelam, N., Roy, A., De, S., & Panja, S. (2020) · MAPAN · doi:10.1007/s12647-020-00397-y · Cited by 20
Metadata
- Authors
- Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., Tew, W. L., & Ye, J.
- Affiliations
- National Institute of Standards and Technology (US)
- Centre for Quantum Technologies (SG)
- Corresponding author
- Ye, J.
- ORCID
- Venue
- Nature Communications
- Published
- 2015-04-21
- Volume
- 6
- Issue
- 1
- Pages
- 6896-6896
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC4411304
- OpenAlex
- W2073958075
- Cited by
- 780
- References
- 53
- Citations by year
- 2026: 33 · 2025: 48 · 2024: 63 · 2023: 61 · 2022: 60 · 2021: 59 · 2020: 68 · 2019: 84 · 2018: 86 · 2017: 81 · 2016: 102 · 2015: 35
- FWCI
- 51.26
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by)
- arXiv (Cornell University) (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- National University of Singapore (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- arXiv (Cornell University)
- Funders
- National Science Foundation
- National Institute of Standards and Technology
- Advanced Research Projects Agency
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- optical lattice clock, strontium-87, systematic uncertainties, fractional frequency stability, AC Stark shift, blackbody radiation shift, thermal environment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.