Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Open accessThe DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index.
Abstract
The pursuit of better atomic clocks has advanced many research areas, providing better quantum state control, new insights in quantum science, tighter limits on fundamental constant variation and improved tests of relativity. The record for the best stability and accuracy is currently held by optical lattice clocks. Here we take an important step towards realizing the full potential of a many-particle clock with a state-of-the-art stable laser. Our 87 Sr optical lattice clock now achieves fractional stability of 2.2 × 10−16 at 1 s. With this improved stability, we perform a new accuracy evaluation of our clock, reducing many systematic uncertainties that limited our previous measurements, such as those in the lattice ac Stark shift, the atoms’ thermal environment and the atomic response to room-temperature blackbody radiation. Our combined measurements have reduced the total uncertainty of the JILA Sr clock to 2.1 × 10−18 in fractional frequency units.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



![Figure 4 The measurement of the 3D1 decay rate. (a) The electronic states used for the decay rate measurement. First, we drive the clock transition and then we use a 200-ns laser pulse to drive the 2.6 μm 3P0→3D1 transition. The 3D1 state decays into the 3P manifold with the branching ratios depicted in the panel. Photons from 3P1→1S0 are collected by a photomultiplier tube (PMT). (b) The sum of photon counts for eight million decay events (black dots), fit with the function y(t)=y0+A{exp[–(t–t0)/τ3P1]–exp[–(t–t0)/τ3D1]} (red curve). Data when the pulse is on is excluded to ensure an unbiased fit. The inset is the error ellipse for the fits of τ3D1 and τ3P1. (c) Lifetime versus atom number. Comparing a constant model of this data with a model that is linear in density (the first-order correction for a density-dependent effect) using an F-test, we find no statistically significant lifetime dependence on density. Error bars represent 1σ fit uncertainties (see Methods). The blue band is the ±1σ confidence interval in the weighted mean of these data.](https://figures.cochat.ai/paper-figures/f28c9fdf8f634e8f945b4ec015e03ac3/systematic-evaluation-of-an-atomic-clock-at-2-1018-total-uncertainty-figure-4.jpg)


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Following the lattice light shift model in Ref. [37], we describe firstand higher-order lattice light shifts in a combined model.”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [37]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“More recently, an accuracy of 2 . 1 × 10 -18 (JILA, Nicholson et al. 2015) has been obtained, equivalent to geopotential differences of 0 . 2 m 2 s -2 , or 2 cm on the geoid.”
From Determination of a high spatial resolution geopotential model using atomic clock comparisons (2017) · cites this paper as Nicholson et al. 2015
The cited source says what the claim attributes to it.
In the citing paper
“In comparison to [24], the uncertainty of Sr2 was reduced owing to an extended investigation of the cold-collision shift and a combined evaluation of the lattice light shifts of different orders, using the model from Ref. [37].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [37]
The cited source says what the claim attributes to it.
In the citing paper
“with the current generation of optical atomic clocks reporting fractional performance below the 10 -17 level 1-5 .”
From Atomic clock performance enabling geodesy below the centimetre level (2018) · cites this paper as [2]
The cited source says what the claim attributes to it.
In the citing paper
“They reach systematic uncertainties of a few 10 -18 , which can be resolved after a mere few hours of measurement with optical lattice clocks based on trapped neutral atoms [2][3][4][5][6].”
From Test of Special Relativity Using a Fiber Network of Optical Clocks (2017) · cites this paper as [4]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences.
C., E. L., & Bevington, P. R. (1972) · Journal of the American Statistical Association · doi:10.2307/2284752 · Cited by 3,534
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Self-citationFrequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Kómár, P., Kessler, E. M., Bishof, M., Jiang, L., Sørensen, A. S., Ye, J., & Lukin, M. D. (2014) · Nature Physics · doi:10.1038/nphys3000 · Cited by 768
Self-citationA sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Kessler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 754
Self-citationSpectroscopy Using Quantum Logic
Schmidt, P. O., Rosenband, T., Langer, C., Itano, W. M., Bergquist, J. C., & Wineland, D. J. (2005) · Science · doi:10.1126/science.1114375 · Cited by 643
Nobel Lecture: Controlling photons in a box and exploring the quantum to classical boundary
Haroche, S. (2013) · Reviews of Modern Physics · doi:10.1103/revmodphys.85.1083 · Cited by 633
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Research works printed but not linked: 3
- Dick, J. G. In Proc 19th Precise Time Time Interval Meet. 133–147 (1987).
- Kimble, H. J. In Proc. XIV Int. Conf. Laser Spectrosc. 80–89 (1999).
- Dick, G., Prestage, J., Greenhall, C. & Maleki, L. In Proc. 22nd Precise Time Time Interval Meet. 487–508 (1990).
Cited by
Items 301–400 of 768
Improved frequency ratio measurement with 87 Sr and 171 Yb optical lattice clocks at NMIJ
Hisai, Y., Akamatsu, D., Kobayashi, T., Hosaka, K., Inaba, H., Hong, F.-L., & Yasuda, M. (2020) · Metrologia · doi:10.1088/1681-7575/abc104 · Cited by 17
“We evaluated the light shift caused by the probe laser employed in Rabi spectroscopy using the value reported in [6].”
Li, L., Wang, J., Bi, J., Zhang, T., Peng, J., Zhi, Y., & Chen, L. (2021) · Review of Scientific Instruments · doi:10.1063/5.0025498 · Cited by 17
Precision theoretical determination of electric-dipole matrix elements in atomic cesium
Tan, H. B. T., & Derevianko, A. (2023) · Physical Review A · doi:10.1103/physreva.107.042809 · Cited by 16
Liu, H., Yin, M.-J., Kong, D., Xu, Q., Zhang, S., & Chang, H. (2015) · Applied Physics Letters · doi:10.1063/1.4933259 · Cited by 16
Dual-Mode Operation of an Optical Lattice Clock Using Strontium and Ytterbium Atoms
Akamatsu, D., Kobayashi, T., Hisai, Y., Tanabe, T., Hosaka, K., Yasuda, M., & Hong, F.-L. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2819888 · Cited by 19
Cheung, C., Kozlov, M. G., Porsev, S. G., Safronova, M. S., Tupitsyn, I. I., & Bondarev, A. I. (2024) · Computer Physics Communications · doi:10.1016/j.cpc.2024.109463 · Cited by 18
“We have developed and tested state-of-the-art relativistic atomic codes [1, 2, 3, 4, 5] capable of computing a wide variety of atomic properties for a large number of atoms and ions [6, 7, 8, 9, 10, 11, 12], including negative ions [13, 14] and highly charged ions [4, 15, 16, 17, 18, 19, 20].”
BackgroundMethodSelf-citationThree-photon process for producing a degenerate gas of metastable alkaline-earth-metal atoms
Barker, D. S., Pisenti, N. C., Reschovsky, B. J., & Campbell, G. K. (2016) · Physical Review A · doi:10.1103/physreva.93.053417 · Cited by 19
On the usefulness of relativistic space-times for the description of the Earth’s gravitational field
Soffel, M. H., & Frutos─Alfaro, F. (2016) · Journal of Geodesy · doi:10.1007/s00190-016-0927-4 · Cited by 17
Sympathetic Cooling of 40 Ca + − 27 Al + Ion Pair Crystal in a Linear Paul Trap
Shang, J., Cui, K., Cao, J. Z., Wang, S., Chao, S., Shu, H.-L., & Huang, X.-R. (2016) · Chinese Physics Letters · doi:10.1088/0256-307x/33/10/103701 · Cited by 17
Relativistic tidal effects on clock-comparison experiments
Qin, C.-G., Tan, Y.-J., & Shao, C.-G. (2019) · Classical and Quantum Gravity · doi:10.1088/1361-6382/ab01ae · Cited by 16
Improvement in the stability of a 40Ca+ ion optical clock using the Ramsey method
Zhang, B., Huang, Y., Hao, Y., Zhang, H., Zeng, M., Guan, H., & Gao, K. (2020) · Journal of Applied Physics · doi:10.1063/5.0012726 · Cited by 16
Optically Loaded Strontium Lattice Clock With a Single Multi-Wavelength Reference Cavity
Barbiero, M., Calonico, D., Levi, F., & Tarallo, M. G. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3165292 · Cited by 22
Measurement of the tune-out wavelength for Cs133 at 880 nm
Ratkata, A., Gregory, P. D., Innes, A. D., Matthies, A. J., McArd, L. A., Mortlock, J. M., Safronova, M. S., Bromley, S., & Cornish, S. L. (2021) · Physical Review A · doi:10.1103/physreva.104.052813 · Cited by 17
Self-citationAtom-Number Enhancement by Shielding Atoms From Losses in Strontium Magneto-Optical Traps
Höschele, J., Buob, S., Rubio-Abadal, A., Makhalov, V., & Tarruell, L. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.064011 · Cited by 20
Costanzo, G. A., Micalizio, S., Godone, A., Camparo, J. C., & Levi, F. (2016) · Physical Review A · doi:10.1103/physreva.93.063404 · Cited by 15
Koepsell, J., Thiele, T., Deiglmayr, J., Wallraff, A. J., & Merkt, F. (2017) · Physical Review A · doi:10.1103/physreva.95.053860 · Cited by 15
Phase noise of frequency doublers in optical clock lasers
Herbers, S., Dörscher, S., Benkler, E., & Lisdat, C. (2019) · Optics Express · doi:10.1364/oe.27.023262 · Cited by 18
Progress on the optical lattice clock
Ludlow, A. D., & Ye, J. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.008 · Cited by 14
Self-citationContinuous cavity QED with an atomic beam
Famà, F., Zhou, S., Heizenreder, B., Tang, M., Bennetts, S., Jäger, S. B., Schäffer, S. A., & Schreck, F. (2024) · Physical Review A · doi:10.1103/physreva.110.063721 · Cited by 17
Josephson Junctions for Metrology Applications
Benz, S. P. (2019) · Springer series in materials science · doi:10.1007/978-3-030-20726-7_15 · Cited by 14
Dynamic multipolar polarizabilities and hyperpolarizabilities of the Sr lattice clock
Wu, F.-F., Tang, Y.-B., Shi, T.-Y., & Tang, L.-Y. (2019) · Physical Review A · doi:10.1103/physreva.100.042514 · Cited by 17
Optical telecommunications-band clock based on neutral titanium atoms
Eustice, S., Filin, D., Schrott, J., Porsev, S. G., Cheung, C., Novoa, D., Stamper-Kurn, D., & Safronova, M. S. (2023) · Physical Review A · doi:10.1103/physreva.107.l051102 · Cited by 15
“We have advanced atomic structure calculations to determine critical properties of such clocks, including identifying magic wavelengths for optical trapping, estimating clock transition widths and line strengths, and determining that the BBR shift for Ti clock transitions is an order of magnitude smaller than the shif…”
BackgroundMethodSelf-citationOptical Technologies for Future Global Navigation Satellite Systems
Schmidt, T. D., Schuldt, T., Michalak, G., Surof, J., Poliak, J., Giorgi, G., Braxmaier, C., Meurer, M., & Günther, C. G. (2023) · IEEE/ION Position Location and Navigation Symposium · doi:10.1109/plans53410.2023.10140082 · Cited by 16
State-dependent potentials for the S01 and P03 clock states of neutral ytterbium atoms
Höhn, T. O., Staub, E., Brochier, G., Oppong, N. D., & Aidelsburger, M. (2023) · Physical Review A · doi:10.1103/physreva.108.053325 · Cited by 19
Finite-field calculation of static polarizabilities and hyperpolarizabilities of In+ and Sr
Yu, Y., Suo, B., Feng, H., Fan, H., & Liu, W. (2015) · Physical Review A · doi:10.1103/physreva.92.052515 · Cited by 15
Coherence transfer of subhertz-linewidth laser light via an 82-km fiber link
Ma, C., Wu, L., Jiang, Y., Yu, H., Bi, Z., & Ma, L.-S. (2015) · Applied Physics Letters · doi:10.1063/1.4937566 · Cited by 14
Clock-related properties of Lu+
Porsev, S. G., Safronova, M. S., & Safronova, M. S. (2018) · Physical Review A · doi:10.1103/physreva.98.022509 · Cited by 14
Self-citationUltra-low noise optical injection locking amplifier with AOM-based coherent detection scheme
Feng, Z., Yang, F., Zhang, X., Chen, D., Wei, F., Cheng, N., Sun, Y., Gui, Y., & Cai, H. (2018) · Scientific Reports · doi:10.1038/s41598-018-31381-x · Cited by 15
Synchronization of active atomic clocks via quantum and classical channels
Roth, A., & Hammerer, K. (2016) · Physical Review A · doi:10.1103/physreva.94.043841 · Cited by 15
Tunable magic wavelengths for trapping with focused Laguerre-Gaussian beams
Bhowmik, A., Dutta, N. N., & Majumder, S. (2018) · Physical Review A · doi:10.1103/physreva.97.022511 · Cited by 14
Quantum time delay in the gravitational field of a rotating mass
Battista, E., Tartaglia, A., Esposito, G. V. M., Lucchesi, D. M., Ruggiero, M. L., Valko, P., Dell’Agnello, S., Fiore, L. D., Simo, J., & Grado, A. (2017) · Classical and Quantum Gravity · doi:10.1088/1361-6382/aa7f11 · Cited by 15
Simulation of force-insensitive optical cavities in cubic spacers
Wiens, E., & Schiller, S. (2018) · Applied Physics B · doi:10.1007/s00340-018-7000-3 · Cited by 13
Precision measurements with cold atoms and trapped ions*
Zhang, Q., Wang, Y., Zhu, C., Wang, Y., Zhang, X., Gao, K., & Zhang, W. (2020) · Chinese Physics B · doi:10.1088/1674-1056/aba9c6 · Cited by 17
Self-citationSteady-state magneto-optical trap of fermionic strontium on a narrow-line transition
Escudero, R. G., Chen, C.-C., Bennetts, S., Pasquiou, B., & Schreck, F. (2021) · Physical Review Research · doi:10.1103/physrevresearch.3.033159 · Cited by 22
“48(5)-kHz-wide [40,41] 1 S 0 - 3 P 1 transition can be locally shifted out of resonance.”
Allehabi, S. O., Dzuba, V. A., & Flambaum, V. V. (2022) · Physical Review A · doi:10.1103/physreva.106.032807 · Cited by 15
A transportable optical lattice clock
Vogt, S., Häfner, S., Grotti, J., Koller, S., Al-Masoudi, A., Sterr, U., & Lisdat, C. (2016) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/723/1/012020 · Cited by 13
Observation of the 1S0 to 3D1 clock transition in 175Lu+
Arnold, K. J., Kaewuam, R., Roy, A., Paez, E. J., Wang, S.-J., & Barrett, M. D. (2016) · Physical Review A · doi:10.1103/physreva.94.052512 · Cited by 14
Self-citationStannard, W. (2018) · Physics Education · doi:10.1088/1361-6552/aaab99 · Cited by 16
Dual-Wavelength Good–Bad-Cavity Laser System for Cavity-Stabilized Active Optical Clock
Pan, D., Shi, T., & Chen, J. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2854738 · Cited by 13
“OPTICAL clocks [1]–[7], where lasers prestabilized by the Pound–Drever–Hall (PDH) technique [8], [9] serve as local oscillators to interrogate ultranarrow optical transitions and then are frequency-stabilized, have achieved both instability and accuracy of 10−18 level [1]–[3], [5], [6].”
MethodRecent Advances Concerning the 87Sr Optical Lattice Clock at the National Time Service Center
Wang, Y., Lu, X., Lu, B., Kong, D., & Chang, H. (2018) · Applied Sciences · doi:10.3390/app8112194 · Cited by 14
Sisyphus optical lattice decelerator
Chen, C.-C., Bennetts, S., Escudero, R. G., Schreck, F., & Pasquiou, B. (2019) · Physical Review A · doi:10.1103/physreva.100.023401 · Cited by 18
Achromatic, planar Fresnel-reflector for a single-beam magneto-optical trap
Bondza, S., Leopold, T., Schwarz, R., & Lisdat, C. (2024) · Review of Scientific Instruments · doi:10.1063/5.0174674 · Cited by 12
Yuan, Y., Cui, K., Liu, D., Yuan, J., Cao, J. Z., Wang, D., Chao, S., Shu, H., & Huang, X.-R. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.044052 · Cited by 13
GHZ protocols enhance frequency metrology despite spontaneous decay
Kielinski, T., Schmidt, P. O., & Hammerer, K. (2024) · Science Advances · doi:10.1126/sciadv.adr1439 · Cited by 33
A 780 nm optical frequency standard based on diffuse laser cooled 87Rb atoms
Guan, X., Zhang, J., Gao, X., Wang, Y., Shi, T., & Chen, J. (2025) · Applied Physics Letters · doi:10.1063/5.0250471 · Cited by 14
Lattice Light Shift Evaluations in a Dual-Ensemble Yb Optical Lattice Clock
Bothwell, T., Hunt, B. D., Siegel, J. L., Hassan, Y. S., Grogan, T., Kobayashi, T., Gibble, K., Porsev, S. G., Safronova, M. S., Brown, R. C., et al. (2025) · Physical Review Letters · doi:10.1103/physrevlett.134.033201 · Cited by 18
Self-citationDesign of an ultra-compact reference ULE cavity
Didier, A., Millo, J., Lacroûte, C., Ouisse, M., Delporte, J., Giordano, V., Rubiola, E., & Kersalé, Y. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/723/1/012029 · Cited by 19
Accuracy budget of the 88 Sr optical atomic clocks at KL FAMO
Radzewicz, C., Bober, M., Morzyński, P., Cygan, A., Lisak, D., Bartoszek-Bober, D., Masłowski, P., Ablewski, P., Zachorowski, J., Gawlik, W., et al. (2016) · Physica Scripta · doi:10.1088/0031-8949/91/8/084003 · Cited by 12
Magic polarization for cancellation of light shifts in two-photon optical clocks
Jackson, S., & Vutha, A. C. (2019) · Physical Review A · doi:10.1103/physreva.99.063422 · Cited by 13
Improved absolute frequency measurement of the strontium ion clock using a GPS link to the SI second
Jian, B., Bernard, J. E., Gertsvolf, M., & Dubé, P. (2022) · Metrologia · doi:10.1088/1681-7575/aca615 · Cited by 17
Highly vibration-resistant sub-Hertz ultra-stable laser passing over 1700 km transport test
Jiao, D., Deng, X., Gao, J., Zhang, L., Xu, G., Liu, T., Dong, R., & Zhang, S. (2023) · Infrared Physics & Technology · doi:10.1016/j.infrared.2023.104608 · Cited by 15
Optical lattice clocks towards the redefinition of the second
Bregolin, F., Milani, G., Pizzocaro, M., Rauf, B., Thoumany, P., Levi, F., & Calonico, D. (2017) · Journal of Physics Conference Series · doi:10.1088/1742-6596/841/1/012015 · Cited by 15
Can the apparent expansion of the universe be attributed to an increasing vacuum refractive index ?
Sarazin, X., Couchot, F., Djannati-Ataï, A., & Urban, M. (2018) · The European Physical Journal C · doi:10.1140/epjc/s10052-018-5932-8 · Cited by 14
Lu, X., Yin, M.-J., Li, T., Wang, Y., & Chang, H. (2020) · Applied Sciences · doi:10.3390/app10041440 · Cited by 13
Xu, Q., Lu, X., Xia, J., Wang, Y., & Chang, H. (2021) · Applied Physics Letters · doi:10.1063/5.0060277 · Cited by 12
Ultraprecision optical frequency standards using ultracold atoms: state of the art and prospects
Taichenachev, A. V., Yudin, V. I., & Bagayev, S. N. (2016) · Uspekhi Fizicheskih Nauk · doi:10.3367/ufnr.0186.201602j.0193 · Cited by 15
Measurement of the 27 Al + and 87 Sr absolute optical frequencies
Leopardi, H., Beloy, K., Bothwell, T., Brewer, S. M., Bromley, S., Chen, J.-S., Diddams, S. A., Fasano, R., Hassan, Y. S., Hume, D. B., et al. (2020) · Metrologia · doi:10.1088/1681-7575/abd040 · Cited by 14
“[1–4].”
Self-citationEvaluation of the blackbody radiation shift of an Yb optical lattice clock at KRISS
Heo, M.-S., Kim, H., Yu, D.-H., Lee, W.-K., & Park, C. Y. (2022) · Metrologia · doi:10.1088/1681-7575/ac8483 · Cited by 15
“Also, there has been a method of measuring Tatom directly using a thermal probe [16] (and additional FE analysis in [17]) in a well-controlled thermal environment.”
MethodA Decade of Advancement of Quantum Sensing and Metrology in India Using Cold Atoms and Ions
Dutta, P., Maurya, S. S., Patel, K., Biswas, K., Mangaonkar, J., Sarkar, S., & Rapol, U. D. (2022) · Journal of the Indian Institute of Science · doi:10.1007/s41745-022-00335-8 · Cited by 11
Contribution of negative-energy states to the E2−M1 polarizability of optical clocks
Wu, F.-F., Shi, T.-Y., Ni, W.-T., & Tang, L.-Y. (2023) · Physical Review A · doi:10.1103/physreva.108.l051101 · Cited by 11
Ultra-low phase noise all-PM Er:fiber optical frequency comb
Hänsel, W., Giunta, M., Beha, K., Lezius, M., Fischer, M., & Holzwarth, R. (2015) · Advanced Solid-State Lasers · doi:10.1364/assl.2015.ath4a.2 · Cited by 11
Wu, K., Shen, Z., Shen, W., Sun, X. L., Cai, C., & Wu, Y. (2020) · Geodesy and Geodynamics · doi:10.1016/j.geog.2020.03.006 · Cited by 12
Distributed Bragg reflector lasers emitting between 696 and 712 nm
Wenzel, H., Arar, B., Maaßdorf, A., Fricke, J., Martin, D., Zink, C., Schiemangk, M., Wicht, A., Weyers, M., & Knigge, A. C. (2022) · Electronics Letters · doi:10.1049/ell2.12645 · Cited by 12
Laser noise imposed limitations of ensemble quantum metrology
Plankensteiner, D., Schachenmayer, J., Ritsch, H., & Genes, C. (2016) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/49/24/245501 · Cited by 11
Adhikari, C. M., Kawasaki, A., & Jentschura, U. D. (2016) · Physical Review A · doi:10.1103/physreva.94.032510 · Cited by 13
“The ac Stark shift due to the black-body radiation is one of the major uncertainties in optical lattice-clock experiments [5], and the ac Stark shift due to the optical lattice light is an essential effect in optical lattice-clock experiments [6,7].”
BackgroundFine-structure transitions as a tool for studying variation of α at high redshifts
Levshakov, S. A., & Kozlov, M. G. (2017) · Monthly Notices of the Royal Astronomical Society Letters · doi:10.1093/mnrasl/slx049 · Cited by 12
“…frequency shift, ∆ω. Laboratory experiments provide extremely high sensitivity with fractional uncertainties of ∆ω/ω ∼ 10−16 − 10−17 (Tyumenev et al. 2016; Nemitz et al. 2016; Huang et al. 2016) and even at the 10−18 level (Nisbet-Jones et al. 2016; Huntemann et al. 2016; Nicholson et al. 2015).”
Laboratory demonstration of geopotential measurement using transportable optical clocks
Liu, D.-X., Cao, J., Yuan, J.-B., Cui, K.-F., Yuan, Y., Zhang, P., Chao, S.-J., Shu, H.-L., & Huang, X.-R. (2023) · Chinese Physics B · doi:10.1088/1674-1056/ac6337 · Cited by 10
Laser-cooling 88 Sr to microkelvin temperature with an integrated-photonics system
Ferdinand, A. R., Luo, Z., Jammi, S., Newman, Z. L., Spektor, G., Koksal, O., Patel, P., Sheredy, D., Lunden, W. D. M., Rakholia, A., et al. (2025) · Physical Review Applied · doi:10.1103/physrevapplied.23.l031002 · Cited by 12
Validating frequency transfer via interferometric fiber links for optical clock comparisons
Koke, S., Benkler, E., Kühl, A., & Grosche, G. (2021) · New Journal of Physics · doi:10.1088/1367-2630/ac21a0 · Cited by 11
Jet-loaded cold atomic beam source for strontium
Kwon, M., Holman, A., Gan, Q., Liu, C.-W., Molinelli, M., Stevenson, I., & Will, S. (2023) · Review of Scientific Instruments · doi:10.1063/5.0131429 · Cited by 18
Porsev, S. G., Kozlov, M. G., & Safronova, M. S. (2023) · Physical Review A · doi:10.1103/physreva.108.l051102 · Cited by 10
Self-citationClassical and quantum frequency combs for satellite-based clock synchronization
Gosalia, R., Aguinaldo, R., Green, J. T., Leopardi, H., Brereton, P., & Malaney, R. (2024) · APL Photonics · doi:10.1063/5.0220546 · Cited by 14
Analysis of the blackbody-radiation shift in an ytterbium optical lattice clock
Xu, Y., & Xu, X. (2016) · Chinese Physics B · doi:10.1088/1674-1056/25/10/103202 · Cited by 12
Ultra Low Noise Er:fiber Frequency Comb Comparison
Giunta, M., Hänsel, W., Beha, K., Fischer, M., Lezius, M., & Holzwarth, R. (2016) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2016.sth4h.1 · Cited by 11
[C i], [C ii] and CO emission lines as a probe for α variations at low and high redshifts
Levshakov, S. A., Ng, K., Henkel, C., & Mookerjea, B. (2017) · Monthly Notices of the Royal Astronomical Society · doi:10.1093/mnras/stx1782 · Cited by 11
“For a shorter period (t <∼ 1000 s), a fractional frequency uncertainty in atomic clocks is ∆ω/ω ∼ 10−18 (Huntemann et al. 2016; Nisbet-Jones et al. 2016; Nicholson et al. 2015), which can provide even tighter constraints on α̇/α with longer time intervals3.”
BackgroundDual-wavelength-pumped Tm3+-doped ZBLAN fiber MOPA at 813 nm
Kajikawa, E., Ishii, T., Kubo, T., Takeuchi, Y.-I., Ogawa, K., & Musha, M. (2019) · Optics Letters · doi:10.1364/ol.44.002875 · Cited by 11
Chang, L., Zhang, L., & Xu, X. (2022) · Expert Systems with Applications · doi:10.1016/j.eswa.2022.117283 · Cited by 10
Experimental determination of the E2−M1 polarizability of the strontium clock transition
Dörscher, S., Klose, J., Marathapalli, S., & Lisdat, C. (2023) · Physical Review Research · doi:10.1103/physrevresearch.5.l012013 · Cited by 11
von der Wense, L., Seiferle, B., Schneider, C., Jeet, J., Amersdorffer, I., Arlt, N., Zacherl, F., Haas, R., Renisch, D., Mosel, P., et al. (2019) · Hyperfine Interactions · doi:10.1007/s10751-019-1564-0 · Cited by 15
“lude 171Yb+ [2] and 27Al+ [3]. In an optical lattice clock, typically 104 atoms are stored and irradiated in parallel to serve as a reference for laser stabilization - prominent examples include 87Sr [4] and 171Yb [5]. In 2003, a new type of clock was proposed that uses a nuclear transition instead of an atomic shell…”
BackgroundZhang, Z., Han, H., Wang, H., Shao, X., Fang, S., & Wei, Z. (2019) · Optics Letters · doi:10.1364/ol.44.005489 · Cited by 11
Portable Frequency Stabilized Lasers for Quantum Technologies Using Digital Techniques
Chau, H. K., Bridges, C., & Nisbet-Jones, P. B. R. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3285974 · Cited by 11
The Tidal Clock Effects of the Lunisolar Gravitational Field and the Earth’s Tidal Deformation
Qin, C.-G., Tan, Y.-J., & Shao, C.-G. (2020) · The Astronomical Journal · doi:10.3847/1538-3881/abc06f · Cited by 11
“These short periods should be treated carefully since the temperature effects may have same periodic effects, as well as the possible violation effects of LI (Nicholson et al. 2015).”
BackgroundRelativistic corrections to the thermal interaction of bound particles
Solovyev, D. A., Zalialiutdinov, T. A., & Anikin, A. (2021) · Physical Review Research · doi:10.1103/physrevresearch.3.023102 · Cited by 9
Atomic Clock Ensemble in Space
Cacciapuoti, L., Busso, A., Jansen, R., Pataraia, S., Peignier, T., Weinberg, S., Crescence, P., Helm, A., Kehrer, J., Koller, S., et al. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2889/1/012005 · Cited by 15
Influence of cosmological expansion in local experiments
Spengler, F., Belenchia, A., Rätzel, D., & Braun, D. (2022) · Classical and Quantum Gravity · doi:10.1088/1361-6382/ac4954 · Cited by 11
Deep macroscopic pure-optical potential for laser cooling and trapping of neutral atoms
Prudnikov, O. N., Ilenkov, R. Y., Taǐchenachev, A. V., Yudin, V. I., & Bagaev, S. N. (2023) · Physical Review A · doi:10.1103/physreva.108.043107 · Cited by 9
Zhang, P., Cao, J. Z., Yuan, J., Liu, D., Yuan, Y., Wei, Y.-F., Shu, H.-L., & Huang, X.-R. (2021) · Metrologia · doi:10.1088/1681-7575/abe9c4 · Cited by 10
Hoang, A. T., Shen, Z., Wu, K., Ning, A., & Shen, W. (2022) · Remote Sensing · doi:10.3390/rs14194850 · Cited by 11
Enhanced magnetic trap loading for atomic strontium
Barker, D. S., Reschovsky, B. J., Pisenti, N. C., & Campbell, G. K. (2015) · Physical Review A · doi:10.1103/physreva.92.043418 · Cited by 13
Effective three-particle forces in polyvalent atoms
Kozlov, M. G., Safronova, M. S., Porsev, S. G., & Tupitsyn, I. I. (2016) · Physical Review A · doi:10.1103/physreva.94.032512 · Cited by 9
Self-citationA compact, sub-Hertz linewidth 729 nm laser for a miniaturized 40 Ca + optical clock
Shang, J., Cao, J. Z., Cui, K., Wang, S., Zhang, P., Yuan, J., Chao, S., Shu, H., & Huang, X.-R. (2016) · Optics Communications · doi:10.1016/j.optcom.2016.08.027 · Cited by 10
Magic Wavelength Measurement of the 87 Sr Optical Lattice Clock at NIM
Wang, Q., Lin, Y., Meng, F., Li, Y., Lin, B.-K., Zang, E., Li, T., & Fang, Z. (2016) · Chinese Physics Letters · doi:10.1088/0256-307x/33/10/103201 · Cited by 10
Why do things fall? How to explain why gravity is not a force
Stannard, W. (2018) · Physics Education · doi:10.1088/1361-6552/aa9d6e · Cited by 9
Sub-femtosecond precision timing synchronization systems
Xin, M., Şafak, K., Peng, M. Y., Callahan, P. T., Kalaydzhyan, A., Wang, W., Shtyrkova, K., Zhang, Q., Chia, S., Jones, B., et al. (2018) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2017.12.040 · Cited by 9
Jin, L., Hang, C., Jiang, Y., Zhu, C., Zheng, Z., Yao, Y., Huang, G., & Ma, L.-S. (2019) · Applied Physics Letters · doi:10.1063/1.5082660 · Cited by 9
Miyake, H., Pisenti, N. C., Elgee, P. K., Sitaram, A., & Campbell, G. K. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1907.06746 · Cited by 9
Reference Ellipsoid and Geoid in Chronometric Geodesy
Kopeikin, S. M. (2016) · Frontiers in Astronomy and Space Sciences · doi:10.3389/fspas.2016.00005 · Cited by 10
“…frequency standards have recently reached stability of 2.2 × 10−16 at 1 s, and demonstrated an overall fractional frequency uncertainty of 2.1× 10−18 (Nicholson et al., 2015) which enables Frontiers in Astronomy and Space Sciences | www.frontiersin.org 2 February 2016 | Volume 3 | Article…”
BackgroundInfluentialKestler, G., Ton, K., Filin, D., Safronova, M. S., & Barreiro, J. T. (2022) · Physical Review A · doi:10.1103/physreva.105.012821 · Cited by 8
Self-citationA normally off time-of-event logging system triggered by a battery-less sensor
Yamada, S., & Toshiyoshi, H. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114306 · Cited by 8
Zhang, J. J., & Li, J. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-95107-4.00004-4 · Cited by 8
Metadata
- Authors
- Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., Tew, W. L., & Ye, J.
- Affiliations
- National Institute of Standards and Technology (US)
- Centre for Quantum Technologies (SG)
- Corresponding author
- Ye, J.
- ORCID
- Venue
- Nature Communications
- Published
- 2015-04-21
- Volume
- 6
- Issue
- 1
- Pages
- 6896-6896
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC4411304
- OpenAlex
- W2073958075
- Cited by
- 780
- References
- 53
- Citations by year
- 2026: 33 · 2025: 48 · 2024: 63 · 2023: 61 · 2022: 60 · 2021: 59 · 2020: 68 · 2019: 84 · 2018: 86 · 2017: 81 · 2016: 102 · 2015: 35
- FWCI
- 51.26
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by)
- arXiv (Cornell University) (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- National University of Singapore (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- arXiv (Cornell University)
- Funders
- National Science Foundation
- National Institute of Standards and Technology
- Advanced Research Projects Agency
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- optical lattice clock, strontium-87, systematic uncertainties, fractional frequency stability, AC Stark shift, blackbody radiation shift, thermal environment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.