Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Open accessThe DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index.
Abstract
The pursuit of better atomic clocks has advanced many research areas, providing better quantum state control, new insights in quantum science, tighter limits on fundamental constant variation and improved tests of relativity. The record for the best stability and accuracy is currently held by optical lattice clocks. Here we take an important step towards realizing the full potential of a many-particle clock with a state-of-the-art stable laser. Our 87 Sr optical lattice clock now achieves fractional stability of 2.2 × 10−16 at 1 s. With this improved stability, we perform a new accuracy evaluation of our clock, reducing many systematic uncertainties that limited our previous measurements, such as those in the lattice ac Stark shift, the atoms’ thermal environment and the atomic response to room-temperature blackbody radiation. Our combined measurements have reduced the total uncertainty of the JILA Sr clock to 2.1 × 10−18 in fractional frequency units.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



![Figure 4 The measurement of the 3D1 decay rate. (a) The electronic states used for the decay rate measurement. First, we drive the clock transition and then we use a 200-ns laser pulse to drive the 2.6 μm 3P0→3D1 transition. The 3D1 state decays into the 3P manifold with the branching ratios depicted in the panel. Photons from 3P1→1S0 are collected by a photomultiplier tube (PMT). (b) The sum of photon counts for eight million decay events (black dots), fit with the function y(t)=y0+A{exp[–(t–t0)/τ3P1]–exp[–(t–t0)/τ3D1]} (red curve). Data when the pulse is on is excluded to ensure an unbiased fit. The inset is the error ellipse for the fits of τ3D1 and τ3P1. (c) Lifetime versus atom number. Comparing a constant model of this data with a model that is linear in density (the first-order correction for a density-dependent effect) using an F-test, we find no statistically significant lifetime dependence on density. Error bars represent 1σ fit uncertainties (see Methods). The blue band is the ±1σ confidence interval in the weighted mean of these data.](https://figures.cochat.ai/paper-figures/f28c9fdf8f634e8f945b4ec015e03ac3/systematic-evaluation-of-an-atomic-clock-at-2-1018-total-uncertainty-figure-4.jpg)


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Following the lattice light shift model in Ref. [37], we describe firstand higher-order lattice light shifts in a combined model.”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [37]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“More recently, an accuracy of 2 . 1 × 10 -18 (JILA, Nicholson et al. 2015) has been obtained, equivalent to geopotential differences of 0 . 2 m 2 s -2 , or 2 cm on the geoid.”
From Determination of a high spatial resolution geopotential model using atomic clock comparisons (2017) · cites this paper as Nicholson et al. 2015
The cited source says what the claim attributes to it.
In the citing paper
“In comparison to [24], the uncertainty of Sr2 was reduced owing to an extended investigation of the cold-collision shift and a combined evaluation of the lattice light shifts of different orders, using the model from Ref. [37].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [37]
The cited source says what the claim attributes to it.
In the citing paper
“with the current generation of optical atomic clocks reporting fractional performance below the 10 -17 level 1-5 .”
From Atomic clock performance enabling geodesy below the centimetre level (2018) · cites this paper as [2]
The cited source says what the claim attributes to it.
In the citing paper
“They reach systematic uncertainties of a few 10 -18 , which can be resolved after a mere few hours of measurement with optical lattice clocks based on trapped neutral atoms [2][3][4][5][6].”
From Test of Special Relativity Using a Fiber Network of Optical Clocks (2017) · cites this paper as [4]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences.
C., E. L., & Bevington, P. R. (1972) · Journal of the American Statistical Association · doi:10.2307/2284752 · Cited by 3,534
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Self-citationFrequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Kómár, P., Kessler, E. M., Bishof, M., Jiang, L., Sørensen, A. S., Ye, J., & Lukin, M. D. (2014) · Nature Physics · doi:10.1038/nphys3000 · Cited by 768
Self-citationA sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Kessler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 754
Self-citationSpectroscopy Using Quantum Logic
Schmidt, P. O., Rosenband, T., Langer, C., Itano, W. M., Bergquist, J. C., & Wineland, D. J. (2005) · Science · doi:10.1126/science.1114375 · Cited by 643
Nobel Lecture: Controlling photons in a box and exploring the quantum to classical boundary
Haroche, S. (2013) · Reviews of Modern Physics · doi:10.1103/revmodphys.85.1083 · Cited by 633
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Research works printed but not linked: 3
- Dick, J. G. In Proc 19th Precise Time Time Interval Meet. 133–147 (1987).
- Kimble, H. J. In Proc. XIV Int. Conf. Laser Spectrosc. 80–89 (1999).
- Dick, G., Prestage, J., Greenhall, C. & Maleki, L. In Proc. 22nd Precise Time Time Interval Meet. 487–508 (1990).
Cited by
Items 101–200 of 768
Prospects and challenges for squeezing-enhanced optical atomic clocks
Schulte, M., Lisdat, C., Schmidt, P. O., Sterr, U., & Hammerer, K. (2020) · Nature Communications · doi:10.1038/s41467-020-19403-7 · Cited by 90
“(2), with N= 10 (blue) and N= 2000 (red) uncorrelated clock atoms.”
BackgroundInfluentialProspects for atomic clocks based on large ion crystals
Arnold, K., Hajiyev, E., Paez, E., Lee, C. H., Barrett, M. D., & Bollinger, J. (2015) · Physical Review A · doi:10.1103/physreva.92.032108 · Cited by 62
Self-citationTerahertz Frequency Metrology for Spectroscopic Applications: a Review
Consolino, L., Bartalini, S., & Natale, P. D. (2017) · Journal of Infrared Millimeter and Terahertz Waves · doi:10.1007/s10762-017-0406-x · Cited by 66
Measuring the Thermodynamic Cost of Timekeeping
Pearson, A., Guryanova, Y., Erker, P., Laird, E. A., Briggs, G. A. D., Huber, M., & Ares, N. (2021) · Physical Review X · doi:10.1103/physrevx.11.021029 · Cited by 74
The $$^{229}$$Th isomer: prospects for a nuclear optical clock
von der Wense, L., & Seiferle, B. (2020) · The European Physical Journal A · doi:10.1140/epja/s10050-020-00263-0 · Cited by 65
Ground-based optical atomic clocks as a tool to monitor vertical surface motion
Bondarescu, R., Schärer, A., Lundgren, A., Hetényi, G., Houlié, N., Jetzer, P., & Bondarescu, M. (2015) · Geophysical Journal International · doi:10.1093/gji/ggv246 · Cited by 56
Lux, O., Sarang, S., Williams, R. J., McKay, A. M., & Mildren, R. P. (2016) · Optics Express · doi:10.1364/oe.24.027812 · Cited by 56
A pyramid MOT with integrated optical cavities as a cold atom platform for an optical lattice clock
Bowden, W., Hobson, R., Hill, I. R., Vianello, A., Schioppo, M., Silva, A., Margolis, H. S., Baird, P. E. G., & Gill, P. (2019) · Scientific Reports · doi:10.1038/s41598-019-48168-3 · Cited by 55
Exploring the foundations of the physical universe with space tests of the equivalence principle
Battelier, B., Bergé, J., Bertoldi, A. D., Blanchet, L., Bongs, K., Bouyer, P., Braxmaier, C., Calonico, D., Fayet, P., Gaaloul, N., et al. (2021) · Experimental Astronomy · doi:10.1007/s10686-021-09718-8 · Cited by 66
“It has recently been pointed out [124], that this effect is not only of importance in atomic clocks [125] but that temperature gradients, leading to AC-Stark shift gradients, act as a force that accelerates the atoms.”
BackgroundOptical frequency distribution using laser repeater stations with planar lightwave circuits
Akatsuka, T., Goh, T., Imai, H., Oguri, K., Ishizawa, A., Ushijima, I., Ohmae, N., Takamoto, M., Katori, H., Hashimoto, T., et al. (2020) · Optics Express · doi:10.1364/oe.383526 · Cited by 55
Hamiltonian engineering of spin-orbit–coupled fermions in a Wannier-Stark optical lattice clock
Aeppli, A., Chu, A., Bothwell, T., Kennedy, C. J., Kedar, D., He, P., Rey, A. M., & Ye, J. (2022) · Science Advances · doi:10.1126/sciadv.adc9242 · Cited by 53
“B ⊥ = { 0 , 0, − + 2( 0 + 1 ) 〈 ̂ S z 〉 + C 0 N loc } (3) A B”
Self-citationAtomic source selection in space-borne gravitational wave detection
Loriani, S., Schlippert, D., Schubert, C., Abend, S., Ahlers, H., Ertmer, W. A., Rudolph, J., Hogan, J. M., Kasevich, M. A., Rasel, E. M., et al. (2019) · New Journal of Physics · doi:10.1088/1367-2630/ab22d0 · Cited by 69
Zanon-Willette, T., Lefèvre, R., Metzdorff, R., Sillitoe, N., Almonacil, S., Minissale, M., de Clercq, E., Тайченачев, А. В., Yudin, V. I., & Arimondo, E. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aac9e9 · Cited by 67
“In atomic transitions with fermionic species weakly allowed by hyperfine mixing [24], the frequency lightshift is usually small and does not represent an important contribution at the present level of relative accuracy [25, 26].”
Chepurov, S. V., Lugovoy, A. A., Prudnikov, O. N., Тайченачев, А. В., & Bagayev, S. N. (2019) · Quantum Electronics · doi:10.1070/qel16996 · Cited by 11
Interference of clocks: A quantum twin paradox
Loriani, S., Friedrich, A., Ufrecht, C., Pumpo, F. D., Kleinert, S., Abend, S., Gaaloul, N., Meiners, C., Schubert, C., Tell, D., et al. (2019) · Science Advances · doi:10.1126/sciadv.aax8966 · Cited by 79
Hachisu, H., Petit, G., Nakagawa, F., Hanado, Y., & Ido, T. (2017) · Optics Express · doi:10.1364/oe.25.008511 · Cited by 53
Ca+40 ion optical clock with micromotion-induced shifts below 1×10−18
Huang (2019) · Physical Review A · doi:10.1103/physreva.99.011401 · Cited by 51
A strontium lattice clock with both stability and uncertainty below 5 × 10 − 18
Li, J., Cui, X.-Y., Jia, Z.-P., Kong, D.-Q., Yu, H.-W., Zhu, X.-Q., Liu, X., Wang, D., Zhang, X., Huang, X.-Y., et al. (2024) · Metrologia · doi:10.1088/1681-7575/ad1a4c · Cited by 56
Optical frequency divider with division uncertainty at the 10−21 level
Yao, Y., Jiang, Y., Yu, H., Bi, Z., & Ma, L. (2016) · National Science Review · doi:10.1093/nsr/nww063 · Cited by 57
Isotope-shift spectroscopy of the S 0 1 → P 1 3 and S 0 1 → P 0 3 transitions in strontium
Miyake, H., Pisenti, N. C., Elgee, P. K., Sitaram, A., & Campbell, G. K. (2019) · Physical Review Research · doi:10.1103/physrevresearch.1.033113 · Cited by 57
Voigt, C., Denker, H., & Timmen, L. (2016) · Metrologia · doi:10.1088/0026-1394/53/6/1365 · Cited by 50
Vast World of Quantum Advantage
Huang, H.-Y., Choi, S., McClean, J. R., & Preskill, J. P. (2026) · Physical Review X · doi:10.1103/tn89-g1xz · Cited by 77
Detection of metastable electronic states by Penning trap mass spectrometry
Schüssler, R. X., Bekker, H., Braß, M., Cakir, H., Crespo López-Urrutia, J. R., Door, M., Filianin, P., Harman, Z., Haverkort, M. W., Huang, W. J., et al. (2020) · Nature · doi:10.1038/s41586-020-2221-0 · Cited by 48
Sr88+single-ion optical clock with a stability approaching the quantum projection noise limit
Dubé, P., Madej, A. A., Shiner, A., & Jian, B. (2015) · Physical Review A · doi:10.1103/physreva.92.042119 · Cited by 50
Vallet, G., Bookjans, E., Eismann, U., Bilicki, S., Targat, R. L., & Lodewyck, J. (2017) · New Journal of Physics · doi:10.1088/1367-2630/aa7c84 · Cited by 51
“have to be reduced. Currently, the most stable clock lasers are frequency-locked to ultra-stable cavities, which have reached stabilities on the order of 10 16, using e.g. a long ultra-stable cavity [6, 5, 1] and a novel cryogenic single-crystal Si cavity [7]. To further push the frequency stability limit of the clock…”
BackgroundMethodInfluentialEngineering Quantum States of Matter for Atomic Clocks in Shallow Optical Lattices
Hutson, R. B., Goban, A., Marti, G. E., Sonderhouse, L., Sanner, C., & Ye, J. (2019) · Physical Review Letters · doi:10.1103/physrevlett.123.123401 · Cited by 54
Self-citationIntermittent optical frequency measurements to reduce the dead time uncertainty of frequency link
Hachisu, H., & Ido, T. (2015) · Japanese Journal of Applied Physics · doi:10.7567/jjap.54.112401 · Cited by 48
Dicke Superradiance in Ordered Arrays of Multilevel Atoms
Masson, S. J., Covey, J. P., Will, S., & Asenjo-García, A. (2024) · PRX Quantum · doi:10.1103/prxquantum.5.010344 · Cited by 67
Radioluminescence and photoluminescence of Th:CaF2 crystals
Stellmer, S., Schreitl, M., & Schumm, T. (2015) · Scientific Reports · doi:10.1038/srep15580 · Cited by 47
Hobson, R., Bowden, W., Vianello, A., Silva, A., Baynham, C. F. A., Margolis, H. S., Baird, P. E. G., Gill, P., & Hill, I. R. (2020) · Metrologia · doi:10.1088/1681-7575/abb530 · Cited by 58
Modified hyper-Ramsey methods for the elimination of probe shifts in optical clocks
Hobson, R., Bowden, W., King, S. A., Baird, P. E. G., Hill, I. R., & Gill, P. (2016) · Physical Review A · doi:10.1103/physreva.93.010501 · Cited by 60
Inner-shell magnetic dipole transition in Tm atoms: A candidate for optical lattice clocks
Сукачев, Д. Д., Fedorov, S., TOLSTIKHINA, I. Y., Tregubov, D. O., Калганова, Е. С., Vishnyakova, G. A., Golovizin, A. A., Kolachevsky, N., Khabarova, K. Y., & Сорокин, В. Н. (2016) · Physical Review A · doi:10.1103/physreva.94.022512 · Cited by 51
The unit of time: Present and future directions
Bize, S. (2019) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2019.02.002 · Cited by 47
“possible uncertainties. Figure 4 explains the principle of operation of these two types of standards. Optical frequency standards achieve fractional frequency uncertainties close to 10−18 [61][62][63][64][65][66][67][68]. For example, reference [61] reports an uncertainty of 1.4 ×10−18 for an 171Yb optical lattice sta…”
BackgroundInfluentialQuantum lock-in force sensing using optical clock Doppler velocimetry
Shaniv, R., & Ozeri, R. (2017) · Nature Communications · doi:10.1038/ncomms14157 · Cited by 50
“5 nm, by a maximum likelihood fit of equation (5) to the data.”
BackgroundMethodA highly stable monolithic enhancement cavity for second harmonic generation in the ultraviolet
Hannig, S., Mielke, J., Fenske, J.-A., Misera, M., Beev, N., Ospelkaus, C., & Schmidt, P. O. (2018) · Review of Scientific Instruments · doi:10.1063/1.5005515 · Cited by 51
Facchinetti, G., & Ruostekoski, J. (2018) · Physical Review A · doi:10.1103/physreva.97.023833 · Cited by 46
“, in metrology [30, 31], we apply the cooperatively coupled atomic arrays to precision measurements of weak magnetic fields.”
MethodImplementing and Characterizing Precise Multiqubit Measurements
Blumoff, J. Z., Chou, K., Shen, C., Reagor, M., Axline, C. J., Brierley, R. T., Silveri, M., Wang, C., Vlastakis, B., Nigg, S. E., et al. (2016) · Physical Review X · doi:10.1103/physrevx.6.031041 · Cited by 52
“Building on impressive progress in control [1, 2], measurement [3, 4], and coherence [5, 6], experimental quantum information science is addressing increasingly complex challenges, such as quantum error correction (QEC) [7–12] and quantum simulation [13, 14].”
Strontium optical lattice clock at the National Time Service Center
Wang, Y., Yin, M.-J., Ren, J., Xu, Q., Lu, B., Han, J.-X., Guo, Y., & Chang, H. (2018) · Chinese Physics B · doi:10.1088/1674-1056/27/2/023701 · Cited by 46
Gravitational Redshift Tests with Atomic Clocks and Atom Interferometers
Pumpo, F. D., Ufrecht, C., Friedrich, A., Giese, E., Schleich, W. P., & Unruh, W. G. (2021) · PRX Quantum · doi:10.1103/prxquantum.2.040333 · Cited by 59
Probing beyond the laser coherence time in optical clock comparisons
Hume, D. B., & Leibrandt, D. R. (2016) · Physical Review A · doi:10.1103/physreva.93.032138 · Cited by 44
Quantum Network of Atom Clocks: A Possible Implementation with Neutral Atoms
Kómár, P., Topcu, T., Kessler, E. M., Derevianko, A., Vuletić, V., Ye, J., & Lukin, M. D. (2016) · Physical Review Letters · doi:10.1103/physrevlett.117.060506 · Cited by 42
Self-citationShang, H., Zhang, X., Zhang, S., Pan, D., Chen, H., & Chen, J. (2017) · Optics Express · doi:10.1364/oe.25.030459 · Cited by 45
Real-time phase tracking for wide-band optical frequency measurements at the 20th decimal place
Giunta, M., Hänsel, W., Fischer, M., Lezius, M., Udem, T., & Holzwarth, R. (2020) · Nature Photonics · doi:10.1038/s41566-019-0520-5 · Cited by 41
Frequency-stabilized Faraday laser with 10−14 short-term instability for atomic clocks
Chang, P., Shi, H., Miao, J., Shi, T., Pan, D., Luo, B., Guo, H. M., & Chen, J. (2022) · Applied Physics Letters · doi:10.1063/5.0083390 · Cited by 41
von der Wense, L., & Zhang, C. (2020) · The European Physical Journal D · doi:10.1140/epjd/e2020-100582-5 · Cited by 46
Terahertz Vibrational Molecular Clock with Systematic Uncertainty at the 10−14 Level
Leung, K. H., Iritani, B., Tiberi, E., Majewska, I., Borkowski, M., Moszyński, R., & Zelevinsky, T. (2023) · Physical Review X · doi:10.1103/physrevx.13.011047 · Cited by 47
Single-ion, transportable optical atomic clocks
Delehaye, M., & Lacroûte, C. (2018) · Journal of Modern Optics · doi:10.1080/09500340.2018.1441917 · Cited by 40
A null test of general relativity based on a long-term comparison of atomic transition frequencies
Ashby, N., Parker, T. E., & Patla, B. R. (2018) · Nature Physics · doi:10.1038/s41567-018-0156-2 · Cited by 53
A perspective on the future of transportable optical lattice clocks
Takamoto, M., Tanaka, Y., & Katori, H. (2022) · Applied Physics Letters · doi:10.1063/5.0087894 · Cited by 40
Margolis, H. S., & Gill, P. (2015) · Metrologia · doi:10.1088/0026-1394/52/5/628 · Cited by 40
Takano, T., Mizushima, R., & Katori, H. (2017) · Applied Physics Express · doi:10.7567/apex.10.072801 · Cited by 35
Laser frequency instability of 2 × 10−16by stabilizing to 30-cm-long Fabry-Pérot cavities at 578 nm
Li, J., Jiang, Y., Yao, Y., Yu, H., Bi, Z., & Ma, L.-S. (2018) · Optics Express · doi:10.1364/oe.26.018699 · Cited by 44
Dichroic Two-Photon Rubidium Frequency Standard
Perrella, C., Light, P. S., Anstie, J. D., Baynes, F. N., White, R. T., & Luiten, A. N. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.12.054063 · Cited by 45
Compact Rb optical frequency standard with 10−15 stability
Zhang, S., Zhang, X., Cui, J., Jiang, Z., Shang, H., Zhu, C., Chang, P., Zhang, L., Tu, J., & Chen, J. (2017) · Review of Scientific Instruments · doi:10.1063/1.5006962 · Cited by 44
Probing Long-Range Neutrino-Mediated Forces with Atomic and Nuclear Spectroscopy
Stadnik, Y. V. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.223202 · Cited by 56
Is the time right for a redefinition of the second by optical atomic clocks?
Gill, P. (2016) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/723/1/012053 · Cited by 37
Muniz, J. A., Young, D. J., Cline, J. R. K., & Thompson, J. K. (2021) · Physical Review Research · doi:10.1103/physrevresearch.3.023152 · Cited by 38
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Riedel, F., Al-Masoudi, A., Benkler, E., Dörscher, S., Gerginov, V, Grebing, C., Häfner, S., Huntemann, N., Lipphardt, B., Lisdat, C., et al. (2020) · Metrologia · doi:10.1088/1681-7575/ab6745 · Cited by 38
Suppressing residual amplitude modulation to the 10−7 level in optical phase modulation
Bi, J., Zhi, Y., Li, L., & Chen, L. (2019) · Applied Optics · doi:10.1364/ao.58.000690 · Cited by 38
Chang, P., Zhang, S., Shang, H., & Chen, J. (2019) · Applied Physics B · doi:10.1007/s00340-019-7313-x · Cited by 43
SI-traceable molecular transition frequency measurements at the 10−12 relative uncertainty level
Reed, Z., Long, D. A., Fleurbaey, H., & Hodges, J. T. (2020) · Optica · doi:10.1364/optica.395943 · Cited by 39
Ramsey Spectroscopy with Displaced Frequency Jumps
Shuker, M., Pollock, J. W., Boudot, R., Yudin, V. I., Тайченачев, А. В., Kitching, J. E., & Donley, E. A. (2019) · Physical Review Letters · doi:10.1103/physrevlett.122.113601 · Cited by 44
A low maintenance Sr optical lattice clock
Hill, I. R., Hobson, R., Bowden, W., Bridge, E. M., Donnellan, S., Curtis, E. A., & Gill, P. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/723/1/012019 · Cited by 37
Kim, H., Heo, M.-S., Lee, W.-K., Park, C. Y., Hong, H.-G., Hwang, S.-W., & Yu, D.-H. (2017) · Japanese Journal of Applied Physics · doi:10.7567/jjap.56.050302 · Cited by 38
Realization of phase locking in good-bad-cavity active optical clock
Shi, T., Pan, D., & Chen, J. (2019) · Optics Express · doi:10.1364/oe.27.022040 · Cited by 39
Demonstration of the nearly continuous operation of an 171 Yb optical lattice clock for half a year
Kobayashi, T., Akamatsu, D., Hosaka, K., Hisai, Y., Wada, M., Inaba, H., Suzuyama, T., Hong, F.-L., & Yasuda, M. (2020) · Metrologia · doi:10.1088/1681-7575/ab9f1f · Cited by 50
Precision measurement and frequency metrology with ultracold atoms
Zhang, X., & Ye, J. (2016) · National Science Review · doi:10.1093/nsr/nww013 · Cited by 51
“The dominant BBR shift is controlled and characterized to high accuracy via precise determination of the Sr polarizability [21,54,55] and by the in situmeasurement of the BBR radiation field around the atoms using radiation thermal sensors calibrated against the NIST International Temperature Scale.”
BackgroundMethodInfluentialSelf-citationThe 229-thorium isomer: doorway to the road from the atomic clock to the nuclear clock
Thirolf, P. G., Seiferle, B., & von der Wense, L. (2019) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/1361-6455/ab29b8 · Cited by 38
A 87 Sr optical lattice clock with 2.9 × 10 − 17 uncertainty and its absolute frequency measurement
Lin, Y., Wang, Q., Meng, F., Cao, S., Wang, Y., Li, Y., Sun, Z. G., Lu, B.-K., Yang, T., Lin, B.-K., et al. (2021) · Metrologia · doi:10.1088/1681-7575/abf33e · Cited by 41
Studying the fundamental limit of optical fiber links to the 10−21 level
Xu, D., Lee, W.-K., Stefani, F., Lopez, O., Amy-Klein, A., & Pottie, P.-E. (2018) · Optics Express · doi:10.1364/oe.26.009515 · Cited by 35
Controlling the interaction of ultracold alkaline-earth atoms
Zhang, R., Cheng, Y., Zhang, P., & Zhai, H. (2020) · Nature Reviews Physics · doi:10.1038/s42254-020-0157-9 · Cited by 44
Ohmae, N., Bregolin, F., Nemitz, N., & Katori, H. (2020) · Optics Express · doi:10.1364/oe.391602 · Cited by 36
Extracting transition rates from zero-polarizability spectroscopy
Safronova, M. S., Zuhrianda, Z., Safronova, M. S., & Clark, C. W. (2015) · Physical Review A · doi:10.1103/physreva.92.040501 · Cited by 44
Self-citationGeneralized hyper-Ramsey resonance with separated oscillating fields
Zanon-Willette, T., Yudin, V. I., & Тайченачев, А. В. (2015) · Physical Review A · doi:10.1103/physreva.92.023416 · Cited by 42
Deceleration, precooling, and multi-pass stopping of highly charged ions in Be+ Coulomb crystals
Schmöger, L., Schwarz, M., Baumann, T. M., Versolato, O. O., Piest, B., Pfeifer, T., Ullrich, J., Schmidt, P. O., & López-Urrutia, J. R. C. (2015) · Review of Scientific Instruments · doi:10.1063/1.4934245 · Cited by 40
Gobron, O., Jung, K., Galland, N., Predehl, K., Targat, R. L., Ferrier, A., Goldner, P., Seidelin, S. L., & Coq, Y. L. (2017) · Optics Express · doi:10.1364/oe.25.015539 · Cited by 42
Probing new physics using Rydberg states of atomic hydrogen
Jones, M. P. A., Potvliege, R. M., & Spannowsky, M. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.013244 · Cited by 39
“01 K have been achieved using platinum resistance thermometers [117].”
MethodLaser controlled atom source for optical clocks
Kock, O., He, W. J., Świerad, D., Smith, L., Hughes, J., Bongs, K., & Singh, Y. (2016) · Scientific Reports · doi:10.1038/srep37321 · Cited by 40
Modeling light shifts in optical lattice clocks
Nemitz, N., Jørgensen, A. A., Yanagimoto, R., Bregolin, F., & Katori, H. (2019) · Physical Review A · doi:10.1103/physreva.99.033424 · Cited by 34
Long-distance chronometric leveling with a portable optical clock
Grotti, J., Nosske, I., Koller, S. B., Herbers, S., Denker, H., Timmen, L., Vishnyakova, G., Grosche, G., Waterholter, T., Kuhl, A., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.l061001 · Cited by 33
“(1) and (2) in the main paper: where we have omitted the labels rem/loc for clarity.”
Measuring molecular frequencies in the 1–10 μm range at 11-digits accuracy
Insero, G., Borri, S., Calonico, D., Pastor, P. C., Clivati, C., D’Ambrosio, D., Natale, P. D., Inguscio, M., Levi, F., & Santambrogio, G. (2017) · Scientific Reports · doi:10.1038/s41598-017-12891-6 · Cited by 35
Frequency comb-based time transfer over a 159 km long installed fiber network
Lessing, M., Margolis, H. S., Brown, C. T. A., & Marra, G. (2017) · Applied Physics Letters · doi:10.1063/1.4984144 · Cited by 38
Baynham, C. F. A., Godun, R. M., Jones, J. M., King, S. A., Nisbet-Jones, P. B. R., Baynes, F., Rolland, A., Baird, P. E. G., Bongs, K., Gill, P., et al. (2018) · Journal of Modern Optics · doi:10.1080/09500340.2017.1384514 · Cited by 32
Injection locking of a low cost high power laser diode at 461 nm
Pagett, C. J. H., Moriya, P. H., Teixeira, R., Shiozaki, R. F., Hemmerling, M., & Courteille, P. W. (2016) · Review of Scientific Instruments · doi:10.1063/1.4947462 · Cited by 32
Fast and dense magneto-optical traps for strontium
Snigirev, S., Park, A. J., Heinz, A., Bloch, I., & Blatt, S. (2019) · Physical Review A · doi:10.1103/physreva.99.063421 · Cited by 38
Nemitz, N., Gotoh, T., Nakagawa, F., Ito, H., Hanado, Y., Ido, T., & Hachisu, H. (2020) · Metrologia · doi:10.1088/1681-7575/abc232 · Cited by 38
Liang, D., Zhang, H., Liu, K., Liu, D., & Wang, R. (2022) · IEEE Geoscience and Remote Sensing Magazine · doi:10.1109/mgrs.2022.3189005 · Cited by 33
Universal visible emitters in nanoscale integrated photonics
Spektor, G., Carlson, D. R., Newman, Z. L., Skarda, J., Sapra, N. V., Su, L., Jammi, S., Ferdinand, A. R., Agrawal, A. K., Vučković, J., et al. (2023) · Optica · doi:10.1364/optica.486747 · Cited by 37
Entanglement and spin squeezing in a network of distant optical lattice clocks
Polzik, E. S., & Ye, J. (2016) · Physical Review A · doi:10.1103/physreva.93.021404 · Cited by 37
Self-citationNonlinear spectroscopy of Sr atoms in an optical cavity for laser stabilization
Christensen, B. T. R., Henriksen, M. R., Schäffer, S. A., Westergaard, P. G., Tieri, D., Ye, J., Holland, M., & Thomsen, J. W. (2015) · Physical Review A · doi:10.1103/physreva.92.053820 · Cited by 35
Self-citationAbsolute distance measurement by chirped pulse interferometry using a femtosecond pulse laser
Wu, H., Zhang, F., Liu, T., Meng, F., Li, J., & Qu, X. (2015) · Optics Express · doi:10.1364/oe.23.031582 · Cited by 36
Longitudinal Ramsey spectroscopy of atoms for continuous operation of optical clocks
Katori, H. (2021) · Applied Physics Express · doi:10.35848/1882-0786/ac0e16 · Cited by 31
Exploring potential applications of optical lattice clocks in a plate subduction zone
Tanaka, Y., & Katori, H. (2021) · Journal of Geodesy · doi:10.1007/s00190-021-01548-y · Cited by 31
Paez, E. J., Arnold, K. J., Hajiyev, E., Porsev, S. G., Dzuba, V. A., Safronova, M. S., Safronova, M. S., & Barrett, M. D. (2016) · Physical Review A · doi:10.1103/physreva.93.042112 · Cited by 32
Self-citationHachisu, H., Petit, G., & Ido, T. (2017) · Applied Physics B · doi:10.1007/s00340-016-6603-9 · Cited by 31
Suppressing Inhomogeneous Broadening in a Lutetium Multi-ion Optical Clock
Tan, T. R., Kaewuam, R., Arnold, K. J., Chanu, S. R., Zhang, Z., Safronova, M. S., & Barrett, M. D. (2019) · Physical Review Letters · doi:10.1103/physrevlett.123.063201 · Cited by 38
Self-citationLuo, L., Qiao, H., Ai, D., Zhou, M., Zhang, S., Sheng, Z., Sun, C., Qi, Q., Peng, C., Jin, T., et al. (2020) · Metrologia · doi:10.1088/1681-7575/abb879 · Cited by 35
Golovizin, A. A., Tregubov, D. O., Fedorova, E. S., Mishin, D., Provorchenko, D. I., Khabarova, K. Y., Sorokin, V. N., & Kolachevsky, N. (2021) · Nature Communications · doi:10.1038/s41467-021-25396-8 · Cited by 34
Blackbody radiation shift in strontium lattice clocks revisited
Lisdat, C., Dörscher, S., Nosske, I., & Sterr, U. (2021) · Physical Review Research · doi:10.1103/physrevresearch.3.l042036 · Cited by 36
General relativistic effects in quantum interference of “clocks”
Zych, M., Pikovski, I., Costa, F., & Brukner, Č. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/723/1/012044 · Cited by 49
Metadata
- Authors
- Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., Tew, W. L., & Ye, J.
- Affiliations
- National Institute of Standards and Technology (US)
- Centre for Quantum Technologies (SG)
- Corresponding author
- Ye, J.
- ORCID
- Venue
- Nature Communications
- Published
- 2015-04-21
- Volume
- 6
- Issue
- 1
- Pages
- 6896-6896
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC4411304
- OpenAlex
- W2073958075
- Cited by
- 780
- References
- 53
- Citations by year
- 2026: 33 · 2025: 48 · 2024: 63 · 2023: 61 · 2022: 60 · 2021: 59 · 2020: 68 · 2019: 84 · 2018: 86 · 2017: 81 · 2016: 102 · 2015: 35
- FWCI
- 51.26
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by)
- arXiv (Cornell University) (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- National University of Singapore (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- arXiv (Cornell University)
- Funders
- National Science Foundation
- National Institute of Standards and Technology
- Advanced Research Projects Agency
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- optical lattice clock, strontium-87, systematic uncertainties, fractional frequency stability, AC Stark shift, blackbody radiation shift, thermal environment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.