The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Photovoltaic restoration of sight with high visual acuity
Open accessAbstract
Patients with retinal degeneration lose sight due to the gradual demise of photoreceptors. Electrical stimulation of surviving retinal neurons provides an alternative route for the delivery of visual information. We demonstrate that subretinal implants with 70-μm-wide photovoltaic pixels provide highly localized stimulation of retinal neurons in rats. The electrical receptive fields recorded in retinal ganglion cells were similar in size to the natural visual receptive fields. Similarly to normal vision, the retinal response to prosthetic stimulation exhibited flicker fusion at high frequencies, adaptation to static images and nonlinear spatial summation. In rats with retinal degeneration, these photovoltaic arrays elicited retinal responses with a spatial resolution of 64 ± 11 μm, corresponding to half of the normal visual acuity in healthy rats. The ease of implantation of these wireless and modular arrays, combined with their high resolution, opens the door to the functional restoration of sight in patients blinded by retinal degeneration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · Choice Reviews Online · doi:10.5860/choice.43-0626 · Cited by 4,674
The contrast sensitivity of retinal ganglion cells of the cat
Enroth-Cugell, C., & Robson, J. G. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp008107 · Cited by 2,625
Spatio-temporal correlations and visual signalling in a complete neuronal population
Pillow, J. W., Shlens, J., Paninski, L., Sher, A., Litke, A. M., Chichilnisky, E. J., & Simoncelli, E. P. (2008) · Nature · doi:10.1038/nature07140 · Cited by 1,311
Self-citationThe role of fixational eye movements in visual perception
Martinez-Conde, S., Macknik, S. L., & Hubel, D. H. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1348 · Cited by 1,255
Parallel processing in the mammalian retina
Wässle, H. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1497 · Cited by 1,252
Neural remodeling in retinal degeneration
Marc, R. E., Jones, B. W., Watt, C. B., & Strettoi, E. (2003) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(03)00039-9 · Cited by 867
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Eye Smarter than Scientists Believed: Neural Computations in Circuits of the Retina
Gollisch, T., & Meister, M. (2010) · Neuron · doi:10.1016/j.neuron.2009.12.009 · Cited by 795
A simple white noise analysis of neuronal light responses
Chichilnisky, E. J. (2001) · Network Computation in Neural Systems · doi:10.1080/net.12.2.199.213 · Cited by 770
Interim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700
A simple white noise analysis of neuronal light responses
Chichilnisky, E. J. (2001) · Network: Computation in Neural Systems · doi:10.1080/713663221 · Cited by 670
Preservation of the Inner Retina in Retinitis Pigmentosa: A Morphometric Analysis
Santos, A. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150513011 · Cited by 643
Statistics review 4: sample size calculations.
Whitley, E., & Ball, J. (2002) · Critical Care · doi:10.1186/cc1521 · Cited by 610
Behavioral assessment of visual acuity in mice and rats
Prusky, G. T., West, P. W. R., & Douglas, R. M. (2000) · Vision Research · doi:10.1016/s0042-6989(00)00081-x · Cited by 589
Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices
Delori, F. C., Webb, R. H., & Sliney, D. H. (2007) · Journal of the Optical Society of America A · doi:10.1364/josaa.24.001250 · Cited by 480
Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473
Photovoltaic retinal prosthesis with high pixel density
Mathieson, K., Loudin, J., Goetz, G., Huie, P., Wang, L., Kamins, T. I., Galambos, L., Smith, R., Harris, J. S., Sher, A., et al. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.104 · Cited by 467
Self-citationRetinal remodeling during retinal degeneration
Jones, B. W., & Marc, R. E. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2005.03.006 · Cited by 428
Morphometric analysis of the extramacular retina from postmortem eyes with retinitis pigmentosa.
Humayun, M. S., Prince, M. R., de Juan, E., Barrón, Y., Moskowitz, M., Klock, I. B., & Milam, A. H. (1999) · PubMed · Cited by 366
Functional connectivity in the retina at the resolution of photoreceptors
Field, G. D., Gauthier, J. L., Sher, A., Greschner, M., Machado, T. A., Jepson, L. H., Shlens, J., Gunning, D. E., Mathieson, K., Dabrowski, W., et al. (2010) · Nature · doi:10.1038/nature09424 · Cited by 332
Self-citationMosaic Arrangement of Ganglion Cell Receptive Fields in Rabbit Retina
Devries, S. H., & Baylor, D. A. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.78.4.2048 · Cited by 313
Correction of the retinal dystrophy phenotype of the RCS rat by viral gene transfer of Mertk
Vollrath, D., Feng, W., Duncan, J. L., Yasumura, D., D'Cruz, P. M., Chappelow, A., Matthes, M. T., Kay, M. A., & LaVail, M. M. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.221364198 · Cited by 290
Litke, A. M., Bezayiff, N., Chichilnisky, E. J., Cunningham, W., Dabrowski, W., Grillo, A. A., Grivich, M., Grybos, P., Hottowy, P., Kachiguine, S., et al. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2004.832706 · Cited by 279
Self-citationThe relationship between visual resolution and cone spacing in the human fovea
Rossi, E. A., & Roorda, A. (2010) · Nature Neuroscience · doi:10.1038/nn.2465 · Cited by 255
Fighting Blindness with Microelectronics
Zrenner, E. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007399 · Cited by 190
Demb, J. B., Zaghloul, K., Haarsma, L., & Sterling, P. (2001) · The Journal of Neuroscience · doi:10.1523/jneurosci.21-19-07447.2001 · Cited by 189
The nonlinear pathway of Y ganglion cells in the cat retina.
Victor, J. D., & Shapley, R. M. (1979) · The Journal of general physiology · doi:10.1085/jgp.74.6.671 · Cited by 173
Nanduri, D., Fine, I., Horsager, A., Boynton, G. M., Humayun, M. S., Greenberg, R. J., & Weiland, J. D. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8401 · Cited by 163
Congenic strains of RCS rats with inherited retinal dystrophy
Vail, M. M. L., Sidman, R. L., & GERHARDT, C. O. (1975) · Journal of Heredity · doi:10.1093/oxfordjournals.jhered.a108621 · Cited by 151
Identification and Characterization of a Y-Like Primate Retinal Ganglion Cell Type
Petrusca, D., Grivich, M. I., Sher, A., Field, G. D., Gauthier, J. L., Greschner, M., Shlens, J., Chichilnisky, E. J., & Litke, A. M. (2007) · Journal of Neuroscience · doi:10.1523/jneurosci.2836-07.2007 · Cited by 149
Self-citationBoinagrov, D., Pangratz-Fuehrer, S., Goetz, G., & Palanker, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026008 · Cited by 146
You, Y., Klistorner, A. I., Thie, J., & Graham, S. L. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.11-7434 · Cited by 146
Photovoltaic retinal prosthesis: implant fabrication and performance
Wang, L., Mathieson, K., Kamins, T. I., Loudin, J., Galambos, L., Goetz, G., Sher, A., Mandel, Y., Huie, P., Lavinsky, D., et al. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/046014 · Cited by 146
Self-citationMandel, Y., Goetz, G., Lavinsky, D., Huie, P., Mathieson, K., Wang, L., Kamins, T. I., Galambos, L., Manivanh, R. V., Harris, J. S., et al. (2013) · Nature Communications · doi:10.1038/ncomms2980 · Cited by 140
Self-citationOptoelectronic retinal prosthesis: system design and performance
Loudin, J., Simanovskii, D. M., Vijayraghavan, K., Sramek, C., Butterwick, A., Huie, P., McLean, G. Y., & Palanker, D. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s09 · Cited by 137
Self-citationThresholds for activation of rabbit retinal ganglion cells with a subretinal electrode
Jensen, R. J., & Rizzo, J. F. (2006) · Experimental Eye Research · doi:10.1016/j.exer.2006.01.012 · Cited by 120
Strauß, O., Stumpff, F., Mergler, S., Wienrich, M., & Wiederholt, M. (1998) · Cells Tissues Organs · doi:10.1159/000046474 · Cited by 103
Resolution of the epiretinal prosthesis is not limited by electrode size
Behrend, M. R., Ahuja, A. K., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2140132 · Cited by 102
Nonlinear analysis of cat retinal ganglion cells in the frequency domain.
Victor, J. D., Shapley, R. M., & Knight, B. W. (1977) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.74.7.3068 · Cited by 89
Lorach, H., Goetz, G., Mandel, Y., Lei, X., Kamins, T. I., Mathieson, K., Huie, P., Dalal, R., Harris, J. S., & Palanker, D. (2014) · Vision Research · doi:10.1016/j.visres.2014.09.007 · Cited by 82
Self-citationVisual pathways and acuity in hooded rats
Dean, P. (1981) · Behavioural Brain Research · doi:10.1016/0166-4328(81)90050-4 · Cited by 82
Improved focalization of electrical microstimulation using microelectrode arrays: a modeling study
Joucla, S., & Yvert, B. (2009) · PLoS ONE · doi:10.1371/journal.pone.0004828 · Cited by 68
Contrast sensitivity and visual acuity of the pigmented rat determined electrophysiologically
Silveira, L. C. L., Heywood, C. A., & Cowey, A. (1987) · Vision Research · doi:10.1016/0042-6989(87)90101-5 · Cited by 65
Lorach, H., Benosman, R. B., Marre, O., Ieng, S.-H., Sahel, J., & Picaud, S. A. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066004 · Cited by 57
Self-citationSpatial receptive field properties of rat retinal ganglion cells
Heine, W. F., & Passaglia, C. L. (2011) · Visual Neuroscience · doi:10.1017/s0952523811000307 · Cited by 49
Photodiode Circuits for Retinal Prostheses
Loudin, J., Cogan, S. F., Mathieson, K., Sher, A., & Palanker, D. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2144980 · Cited by 47
Self-citationReceptive Field Mosaics of Retinal Ganglion Cells Are Established Without Visual Experience
Anishchenko, A., Greschner, M., Elstrott, J., Sher, A., Litke, A. M., Feller, M. B., & Chichilnisky, E. J. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00896.2009 · Cited by 47
Self-citationThe effect of contrast and spatial frequency on the visual evoked potential of the hooded rat
Harnois, C., Bodis-Wollner, I. G., & ONOFRJ, M. C. (1984) · Experimental Brain Research · doi:10.1007/bf00231126 · Cited by 34
Holographic display system for restoration of sight to the blind
Goetz, G., Mandel, Y., Manivanh, R. V., Palanker, D., & Čižmár, T. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056021 · Cited by 34
Self-citationLocal signaling from a retinal prosthetic in a rodent retinitis pigmentosa modelin vivo
Fransen, J. W., Pangeni, G., Pardue, M. T., & McCall, M. A. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/4/046012 · Cited by 12
Cited by
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
The Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351
Retinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272
Photovoltaic Restoration of Central Vision in Atrophic Age-Related Macular Degeneration
Palanker, D., Le Mer, Y., Mohand-Said, S., Muqit, M., & Sahel, J. A. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2020.02.024 · Cited by 227
Self-citationAn update on retinal prostheses
Ayton, L. N., Barnes, N., Dagnelie, G., Fujikado, T., Goetz, G., Hornig, R., Jones, B. W., Muqit, M. M. K., Rathbun, D. L., Stingl, K., et al. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.11.029 · Cited by 223
Self-citation
Metadata
- Authors
- Lorach, H., Goetz, G., Smith, R., Lei, X., Mandel, Y., Kamins, T., Mathieson, K., Huie, P., Harris, J., Sher, A., & Palanker, D.
- Venue
- Nature Medicine
- Published
- 2015-04-27
- Volume
- 21
- Issue
- 5
- Pages
- 476-482
- ISSN
- 1078-8956 (ISSN-L)
- 1546-170X
- OpenAlex
- W2127137933
- Cited by
- 351
- References
- 50
- FWCI
- 13.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.