Macroporous nanowire nanoelectronic scaffolds for synthetic tissues
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
The development of three-dimensional (3D) synthetic biomaterials as structural and bioactive scaffolds is central to fields ranging from cellular biophysics to regenerative medicine. As of yet, these scaffolds cannot electrically probe the physicochemical and biological micro-environments throughout their 3D and macroporous interior, although this capability could have a marked impact in both electronics and biomaterials. Here, we address this challenge using macroporous, flexible and free-standing nanowire nanoelectronic scaffolds (nanoES), and their hybrids with synthetic or natural biomaterials. 3D macroporous nanoES mimic the structure of natural tissue scaffolds, and they were formed by self-organization of coplanar reticular networks with built-in strain and by manipulation of 2D mesh matrices. NanoES exhibited robust electronic properties and have been used alone or combined with other biomaterials as biocompatible extracellular scaffolds for 3D culture of neurons, cardiomyocytes and smooth muscle cells. Additionally, we show the integrated sensory capability of the nanoES by real-time monitoring of (i) the local electrical activity within 3D nanoES/cardiomyocyte constructs, (ii) the response of 3D nanoES based neural and cardiac tissue models to drugs, and (iii) distinct pH changes inside and outside tubular vascular smooth muscle constructs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recent advancements in soft and nanomaterials have opened up more options for flexible recording electrodes, like conductive polymers (e.g., PEDOT)[302,312] and nanomaterial composites (metal-based, CNT, graphene)[313–317].”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [313]
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250 · cited 1×
“The bottom PLGA layer was made either by inserting an existing layer underneath the mesh-like scaffold or by directly electrospinning on the nanoES.”
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Ultralight Metallic Microlattices
Schaedler, T. A., Jacobsen, A. J., Torrents, A., Sorensen, A. E., Lian, J., Greer, J. R., Valdevit, L., & Carter, W. B. (2011) · Science · doi:10.1126/science.1211649 · Cited by 1,784 · cited 2×
“c, SEM image of a single-kinked-nanowire FET within a reticular scaffold, showing (1) the kinked nanowire, (2) metallic interconnects (dashed magenta lines) and (3) the SU-8 backbone.”
Photodegradable Hydrogels for Dynamic Tuning of Physical and Chemical Properties
Kloxin, A. M., Kasko, A. M., Salinas, C. N., & Anseth, K. S. (2009) · Science · doi:10.1126/science.1169494 · Cited by 1,748 · cited 1×
“(5) The silicon substrate was then coated with MMA and PMMA double layer resist, the resist was patterned over the chosen SU-8 ribbons, and then nonsymmetrical Cr/ Pd/Cr (1.”
Interfering with pH regulation in tumours as a therapeutic strategy
Neri, D., & Supuran, C. T. (2011) · Nature Reviews Drug Discovery · doi:10.1038/nrd3554 · Cited by 1,547
Nanoelectronics from the bottom up
Lu, W., & Lieber, C. M. (2007) · Nature Materials · doi:10.1038/nmat2028 · Cited by 1,545
Self-citationA completely biological tissue-engineered human blood vessel
L'heureux, N., Pâquet, S., Labbé, R., Germain, L., & Auger, F. A. (1998) · The FASEB Journal · doi:10.1096/fasebj.12.1.47 · Cited by 1,402
Nanotechnological strategies for engineering complex tissues
Dvir, T., Timko, B. P., Kohane, D. S., & Langer, R. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2010.246 · Cited by 1,367
Self-citationA Rubberlike Stretchable Active Matrix Using Elastic Conductors
Sekitani, T., Noguchi, Y., Hata, K., Fukushima, T., Aida, T., & Someya, T. (2008) · Science · doi:10.1126/science.1160309 · Cited by 1,366
Research works printed but not linked: 1
- Zipes, D. P. & Jalife, J. Cardiac Electrophysiology: From Cell to Bedside 5th edn (Saunders, 2009).
Cited by
Injectable, Cellular-Scale Optoelectronics with Applications for Wireless Optogenetics
Kim, T.-I., McCall, J. G., Jung, Y. H., Huang, X., Siuda, E. R., Li, Y., Song, J., Song, Y. M., Pao, H. A., Kim, R.-H., et al. (2013) · Science · doi:10.1126/science.1232437 · Cited by 1,174
Fractal design concepts for stretchable electronics
Fan, J. A., Yeo, W.-H., Su, Y., Hattori, Y., Lee, W., Jung, S.-Y., Zhang, Y., Liu, Z., Cheng, H., Falgout, L., et al. (2014) · Nature Communications · doi:10.1038/ncomms4266 · Cited by 1,088
“square, (2) thick mesh, (3) thin mesh, (4) horizontal and vertical stripes separated by a spacer, (5) Peano curve, (6) Hilbert curve, (7) Serpentine Greek”
BackgroundFunctional and Biomimetic Materials for Engineering of the Three-Dimensional Cell Microenvironment
Huang, G., Li, F., Zhao, X., Ma, Y., Li, Y., Lin, M., Jin, G., Lu, T. J., Genin, G. M., & Xu, F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00094 · Cited by 825
Novel electrode technologies for neural recordings
Hong, G., & Lieber, C. M. (2019) · Nature Reviews Neuroscience · doi:10.1038/s41583-019-0140-6 · Cited by 695
Self-citationSyringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Self-citation3D biofabrication strategies for tissue engineering and regenerative medicine
Bajaj, P., Schweller, R. M., Khademhosseini, A., West, J. L., & Bashir, R. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-105155 · Cited by 632
“8-mm separation in a nanoES/cardiac construct (168).”
BackgroundFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Tissue–electronics interfaces: from implantable devices to engineered tissues
Feiner, R., & Dvir, T. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.76 · Cited by 595
Self-citationMaterials for flexible bioelectronic systems as chronic neural interfaces
Song, E., Li, J., Won, S. M., Bai, W., & Rogers, J. A. (2020) · Nature Materials · doi:10.1038/s41563-020-0679-7 · Cited by 498
Organ-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
Harris, K. D., Elias, A. L., & Chung, H.-J. (2016) · Journal of Materials Science · doi:10.1007/s10853-015-9643-3 · Cited by 403
“nanowire sensors embedded in a tissue scaffold [442].”
BackgroundElastocapillary self-assembled neurotassels for stable neural activity recordings
Guan, S., Wang, J., Gu, X., Zhao, Y., Hou, R., Fan, H., Zou, L., Gao, L., Du, M., Li, C., et al. (2019) · Science Advances · doi:10.1126/sciadv.aav2842 · Cited by 222
Peripheral nerve conduits: technology update
Hasirci, V., Arslantunali, D., Dursun, T., Yucel, D., & Hasirci, N. (2014) · Medical Devices Evidence and Research · doi:10.2147/mder.s59124 · Cited by 224
“Synthetic nerve conduits Biodegradable synthetic polymers are attractive alternatives to the natural origin biopolymers due to the following advantages: 1) some biodegradable synthetic polymers are biocompatible and they do not initiate any immunological responses, 2) their mechanical properties and degradation rates…”
Li, Q., Nan, K., Le Floch, P., Lin, Z., Sheng, H., Blum, T. S., & Liu, J. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b02512 · Cited by 224
Self-citationRecent Advances in Materials, Devices, and Systems for Neural Interfaces
Won, S. M., Song, E., Zhao, J., Li, J., Rivnay, J., & Rogers, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201800534 · Cited by 206
Mesh electronics: a new paradigm for tissue-like brain probes
Hong, G., Yang, X., Zhou, T., & Lieber, C. M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2017.11.007 · Cited by 159
“cardiac and vascular) using nanowire devices capable of detecting chemical signals, mechanical strain and extracellular potentials [32 ,33], as well as simultaneous electrical stimulation and recording that allows for bidirectional flow of information [34 ].”
Self-citationLuan, L., Robinson, J. T., Aazhang, B., Chi, T., Yang, K., Li, X., Rathore, H., Singer, A., Yellapantula, S., Fan, Y., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.011 · Cited by 150
“One approach has been to engineer the form factors of the electrodes to achieve a high level of flexibility (Tian et al., 2012).”
BackgroundSun, H., Zhou, J., Huang, Z., Qu, L., Lin, N., Liang, C., Dai, R., Tang, L., & Tian, F. (2017) · International Journal of Nanomedicine · doi:10.2147/ijn.s128030 · Cited by 144
“More recently, the inclusion of electrically conductive nanomaterials has been demonstrated to address the current shortcomings of these conventional hydrogels.(11,18,19) Specifically, CNTs, due to their outstanding mechanical and electrical properties, have been incorporated with Col to fabricate electroactive nanoco…”
Integrating Organs-on-Chips: Multiplexing, Scaling, Vascularization, and Innervation
Park, D., Lee, J., Chung, J. J., Jung, Y., & Kim, S. H. (2020) · Trends in Biotechnology · doi:10.1016/j.tibtech.2019.06.006 · Cited by 105
Farooq, A. S., & Zhang, P. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.113715 · Cited by 88
Micelle-enabled self-assembly of porous and monolithic carbon membranes for bioelectronic interfaces
Fang, Y., Prominski, A., Rotenberg, M. Y., Meng, L., Acarón Ledesma, H., Lv, Y., Yue, J., Schaumann, E., Jeong, J., Yamamoto, N., et al. (2021) · Nature Nanotechnology · doi:10.1038/s41565-020-00805-z · Cited by 66
Self-citationSyringe-injectable electronics with a plug-and-play input/output interface.
Schuhmann, T. G., Yao, J., Hong, G., Fu, T.-M., & Lieber, C. M. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b03081 · Cited by 63
Self-citationNanowire electrodes for high-density stimulation and measurement of neural circuits
Robinson, J. T., Jorgolli, M., & Park, H. (2013) · Frontiers in Neural Circuits · doi:10.3389/fncir.2013.00038 · Cited by 60
“Recently Tian et al. have taken steps in this direction by embedding NW FETs in a flexible polymer matrix and releasing them from the rigid substrate (Tian et al., 2012).”
Electro-metabolic coupling in multi-chambered vascularized human cardiac organoids
Ghosheh, M., Ehrlich, A., Ioannidis, K., Ayyash, M., Goldfracht, I., Cohen, M., Fischer, A., Mintz, Y., Gepstein, L., & Nahmias, Y. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01071-9 · Cited by 65
Self-assembled ultraflexible probes for long-term neural recordings and neuromodulation
Guan, S., Tian, H., Yang, Y., Liu, M., Ding, J., Wang, J., & Fang, Y. Z. (2023) · Nature Protocols · doi:10.1038/s41596-023-00824-9 · Cited by 51
Brain implantation of soft bioelectronics via embryonic development
Sheng, H., Liu, R., Li, Q., Lin, Z., He, Y., Blum, T. S., Zhao, H., Tang, X., Wang, W., Jin, L., et al. (2025) · Nature · doi:10.1038/s41586-025-09106-8 · Cited by 58
Self-citationYang, X., Qi, Y., Wang, C., Zwang, T. J., Rommelfanger, N. J., Hong, G., & Lieber, C. M. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01101-6 · Cited by 31
“Notably, bioelectronics can function not only as chronic recording and stimulation interfaces for in vitro 14–16 and in vivo nervous systems 17–21 , but also as bioactive scaffolds used for in vitro cell culture 14 and impact cell migration in vivo 17 .”
BackgroundMethodInfluentialSelf-citationLin, Z., Wang, W., Liu, R., Li, Q., Lee, J., Hirschler, C., & Liu, J. (2025) · Nature Protocols · doi:10.1038/s41596-025-01147-7 · Cited by 28
The Pursuit of Chronically Reliable Neural Interfaces: A Materials Perspective
Guo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00599 · Cited by 19
“(A) Macroporous nanowire electrode array with integrated tissue scaffold (Tian et al., 2012), and (B) ECM-based microelectrodes (Shen et al., 2015).”
BackgroundMethodInfluentialNanotechnology meets electrophysiology
Kwiat, M., Stein, D., & Patolsky, F. (2013) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2012.11.014 · Cited by 16
Kirigami pattern design for buckling-induced assembly 3D structures via topology optimization
Zhang, W., Zhuang, X., Youn, S., & Guo, X. (2023) · Extreme Mechanics Letters · doi:10.1016/j.eml.2023.102099 · Cited by 15
Computational Modeling of Inorganic Nanomaterials
Buckeridge, J., & Sokol, A. A. (2016) · CRC Press eBooks · doi:10.1201/b19528 · Cited by 12
Mechanically Compliant Neural Interfaces
Minev, I. R., & Lacour, S. P. (2016) · Microsystems and nanosystems · doi:10.1007/978-3-319-28694-5_13 · Cited by 3
“The microtopographical organization of the extracellular matrix can be mimicked using macroporous solids whose interconnected system of voids can host both cells and functional components of the interface [66].”
BackgroundFolding and assembly methods for forming three-dimensional mesostructures
Fan, Z., Zhang, F., & Zhang, Y. (2018) · Chinese Science Bulletin (Chinese Version) · doi:10.1360/n972018-00396 · Cited by 2
An electromechanical hug for the failing heart
Feiner, R., & Dvir, T. (2016) · Annals of Translational Medicine · doi:10.21037/atm.2016.08.36
“The electrodes inside the tissue could report both on the function of the heart and on that of the engineered tissue as has recently been demonstrated (12,13).”
BackgroundSelf-citationRecording and Processing of Brain Waves using Nanotechnology
Welch, B., & Liu, C. (2019) · doi:10.17303/jnsm.2018.3.101
Horowitz, L. G. (2023) · Acta Scientific Medical Sciences · doi:10.31080/asms.2023.07.1534
Advances In Therapeutic Use of Microfluidics (Body on A Chip): A Review
(2023) · International Journal of Nanotechnology and Nanomedicine · doi:10.33140/ijnn.08.01.07
Metadata
- Authors
- Tian, B., Liu, J., Dvir, T., Jin, L., Tsui, J. H., Qing, Q., Suo, Z., Langer, R., Kohane, D. S., & Lieber, C. M.
- Affiliations
- Harvard University (US)
- Boston Children's Hospital (US)
- Corresponding author
- Kohane, Daniel S.
- Lieber, Charles M.
- ORCID
- Venue
- Nature Materials
- Published
- 2012-08-26
- Volume
- 11
- Issue
- 11
- Pages
- 986-994
- ISSN
- 1476-1122 (ISSN-L)
- 1476-4660
- PMC
- PMC3623694
- OpenAlex
- W1566118744
- Semantic Scholar
- a2e3dd875e3921aac870aa425019584caf823e20
- Cited by
- 20
- References
- 43
- Citations by year
- 2025: 2 · 2023: 6 · 2022: 1 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 3 · 2014: 2 · 2013: 2
- FWCI
- 0.53
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Nature Materials (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion)
- PMC
- Funders
- National Institutes of Health (5r01de016516-10, DP1OD003900)
- National Institute of General Medical Sciences (GM073626, R01GM073626)
- National Institute of Dental and Craniofacial Research (DE016516, R01-DE016516, DE013023, R01DE013023)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Nanowire Synthesis and Applications
- Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
- Keywords
- macroporous scaffolds, 3D biomaterials, vascular smooth muscle, drug response, pH sensing, regenerative medicine
- MeSH terms
- Biocompatible Materials, Humans, Muscle, Smooth, Vascular, Silicon, Transistors, Electronic, Porosity, Tissue Engineering, Nanotechnology, Nanowires, Tissue Scaffolds
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.