Macroporous nanowire nanoelectronic scaffolds for synthetic tissues
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
The development of three-dimensional (3D) synthetic biomaterials as structural and bioactive scaffolds is central to fields ranging from cellular biophysics to regenerative medicine. As of yet, these scaffolds cannot electrically probe the physicochemical and biological micro-environments throughout their 3D and macroporous interior, although this capability could have a marked impact in both electronics and biomaterials. Here, we address this challenge using macroporous, flexible and free-standing nanowire nanoelectronic scaffolds (nanoES), and their hybrids with synthetic or natural biomaterials. 3D macroporous nanoES mimic the structure of natural tissue scaffolds, and they were formed by self-organization of coplanar reticular networks with built-in strain and by manipulation of 2D mesh matrices. NanoES exhibited robust electronic properties and have been used alone or combined with other biomaterials as biocompatible extracellular scaffolds for 3D culture of neurons, cardiomyocytes and smooth muscle cells. Additionally, we show the integrated sensory capability of the nanoES by real-time monitoring of (i) the local electrical activity within 3D nanoES/cardiomyocyte constructs, (ii) the response of 3D nanoES based neural and cardiac tissue models to drugs, and (iii) distinct pH changes inside and outside tubular vascular smooth muscle constructs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recent advancements in soft and nanomaterials have opened up more options for flexible recording electrodes, like conductive polymers (e.g., PEDOT)[302,312] and nanomaterial composites (metal-based, CNT, graphene)[313–317].”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [313]
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250 · cited 1×
“The bottom PLGA layer was made either by inserting an existing layer underneath the mesh-like scaffold or by directly electrospinning on the nanoES.”
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Ultralight Metallic Microlattices
Schaedler, T. A., Jacobsen, A. J., Torrents, A., Sorensen, A. E., Lian, J., Greer, J. R., Valdevit, L., & Carter, W. B. (2011) · Science · doi:10.1126/science.1211649 · Cited by 1,784 · cited 2×
“c, SEM image of a single-kinked-nanowire FET within a reticular scaffold, showing (1) the kinked nanowire, (2) metallic interconnects (dashed magenta lines) and (3) the SU-8 backbone.”
Photodegradable Hydrogels for Dynamic Tuning of Physical and Chemical Properties
Kloxin, A. M., Kasko, A. M., Salinas, C. N., & Anseth, K. S. (2009) · Science · doi:10.1126/science.1169494 · Cited by 1,748 · cited 1×
“(5) The silicon substrate was then coated with MMA and PMMA double layer resist, the resist was patterned over the chosen SU-8 ribbons, and then nonsymmetrical Cr/ Pd/Cr (1.”
Interfering with pH regulation in tumours as a therapeutic strategy
Neri, D., & Supuran, C. T. (2011) · Nature Reviews Drug Discovery · doi:10.1038/nrd3554 · Cited by 1,547
Nanoelectronics from the bottom up
Lu, W., & Lieber, C. M. (2007) · Nature Materials · doi:10.1038/nmat2028 · Cited by 1,545
Self-citationA completely biological tissue-engineered human blood vessel
L'heureux, N., Pâquet, S., Labbé, R., Germain, L., & Auger, F. A. (1998) · The FASEB Journal · doi:10.1096/fasebj.12.1.47 · Cited by 1,402
Nanotechnological strategies for engineering complex tissues
Dvir, T., Timko, B. P., Kohane, D. S., & Langer, R. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2010.246 · Cited by 1,367
Self-citationA Rubberlike Stretchable Active Matrix Using Elastic Conductors
Sekitani, T., Noguchi, Y., Hata, K., Fukushima, T., Aida, T., & Someya, T. (2008) · Science · doi:10.1126/science.1160309 · Cited by 1,366
Nanowire active-matrix circuitry for low-voltage macroscale artificial skin
Takei, K., Takahashi, T., Ho, J. C., Ko, H., Gillies, A. G., Leu, P. W., Fearing, R. S., & Javey, A. (2010) · Nature Materials · doi:10.1038/nmat2835 · Cited by 1,274
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136
Human tissue-engineered blood vessels for adult arterial revascularization
L'Heureux, N., Dusserre, N., Konig, G., Victor, B., Keire, P., Wight, T. N., Chronos, N. A. F., Kyles, A. E., Gregory, C. R., Hoyt, G., et al. (2006) · Nature Medicine · doi:10.1038/nm1364 · Cited by 1,083
Accordion-like honeycombs for tissue engineering of cardiac anisotropy
Engelmayr, G. C., Cheng, M., Bettinger, C. J., Borenstein, J. T., Langer, R., & Freed, L. E. (2008) · Nature Materials · doi:10.1038/nmat2316 · Cited by 848
Self-citationDirecting Zeolite Structures into Hierarchically Nanoporous Architectures
Na, K., Jo, C., Kim, J., Cho, K., Jung, J., Seo, Y., Messinger, R. J., Chmelka, B. F., & Ryoo, R. (2011) · Science · doi:10.1126/science.1204452 · Cited by 847 · cited 2×
“c, SEM image of a single-kinked-nanowire FET within a reticular scaffold, showing (1) kinked nanowires, (2) metallic interconnects (dashed magenta lines) and (3) the SU-8 backbone.”
BackgroundSynthetic polymer scaffolds for tissue engineering
Place, E. S., George, J. H., Williams, C. K., & Stevens, M. M. (2009) · Chemical Society Reviews · doi:10.1039/b811392k · Cited by 815
Three-Dimensional, Flexible Nanoscale Field-Effect Transistors as Localized Bioprobes
Tian, B., Cohen-Karni, T., Qing, Q., Duan, X., Xie, P., & Lieber, C. M. (2010) · Science · doi:10.1126/science.1192033 · Cited by 798
Self-citationKim, D.-H., Lu, N., Ghaffari, R., Kim, Y.-S., Lee, S. P., Xu, L., Wu, J., Kim, R.-H., Song, J., Liu, Z., et al. (2011) · Nature Materials · doi:10.1038/nmat2971 · Cited by 770
Nanowired three-dimensional cardiac patches
Dvir, T., Timko, B. P., Brigham, M. D., Naik, S. R., Karajanagi, S. S., Levy, O., Jin, H., Parker, K. K., Langer, R., & Kohane, D. S. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.160 · Cited by 760
Self-citationMetabolic acidosis: pathophysiology, diagnosis and management
Kraut, J. A., & Madias, N. E. (2010) · Nature Reviews Nephrology · doi:10.1038/nrneph.2010.33 · Cited by 560
Biocompatibility and biofouling of MEMS drug delivery devices
Voskerician, G., Shive, M. S., Shawgo, R. S., Recum, H. V., Anderson, J. M., Cima, M. J., & Langer, R. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00565-3 · Cited by 558
Self-citationProgrammable nanowire circuits for nanoprocessors
Yan, H., Choe, H. S., Nam, S., Hu, Y., Das, S., Klemic, J. F., Ellenbogen, J. C., & Lieber, C. M. (2011) · Nature · doi:10.1038/nature09749 · Cited by 527
Self-citationWylie, R. G., Ahsan, S., Aizawa, Y., Maxwell, K. L., Morshead, C. M., & Shoichet, M. S. (2011) · Nature Materials · doi:10.1038/nmat3101 · Cited by 480
A Conformal, Bio-Interfaced Class of Silicon Electronics for Mapping Cardiac Electrophysiology
Viventi, J., Kim, D.-H., Moss, J. D., Kim, Y.-S., Blanco, J. A., Annetta, N., Hicks, A., Xiao, J., Huang, Y., Callans, D. J., et al. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000738 · Cited by 420
Synthetic Biology Moving into the Clinic
Ruder, W. C., Lu, T., & Collins, J. J. (2011) · Science · doi:10.1126/science.1206843 · Cited by 412
Biomaterials offer cancer research the third dimension
Hutmacher, D. W. (2010) · Nature Materials · doi:10.1038/nmat2619 · Cited by 323 · cited 1×
“After trituration, cells were isolated by centrifugation at 200 g for 1 min, then re-suspended in 5-10 mg/ml Matrigel TM (BD Bioscience, Bedford, MA) at 4 (cid:113) C.”
Bottom-Up Synthetic Biology: Engineering in a Tinkerer’s World
Schwille, P. (2011) · Science · doi:10.1126/science.1211701 · Cited by 264
Decellularized Porcine Brain Matrix for Cell Culture and Tissue Engineering Scaffolds
DeQuach, J. A., Yuan, S. H., Goldstein, L. S. B., & Christman, K. L. (2011) · Tissue Engineering Part A · doi:10.1089/ten.tea.2010.0724 · Cited by 234
Three-dimensional biomaterials for the study of human pluripotent stem cells
Kraehenbuehl, T. P., Langer, R., & Ferreira, L. S. (2011) · Nature Methods · doi:10.1038/nmeth.1671 · Cited by 226
Self-citationFlexible electrical recording from cells using nanowire transistor arrays
Cohen-Karni, T., Timko, B. P., Weiss, L. E., & Lieber, C. M. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0902752106 · Cited by 218
Self-citationElectrical Recording from Hearts with Flexible Nanowire Device Arrays
Timko, B. P., Cohen-Karni, T., Yu, G., Qing, Q., Tian, B., & Lieber, C. M. (2009) · Nano Letters · doi:10.1021/nl900096z · Cited by 215
Self-citationNanowire transistor arrays for mapping neural circuits in acute brain slices
Qing, Q., Pal, S. K., Tian, B., Duan, X., Timko, B. P., Cohen-Karni, T., Murthy, V. N., & Lieber, C. M. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0914737107 · Cited by 197
Self-citationBaker, M. (2011) · Nature · doi:10.1038/471661a · Cited by 188
Sapir, Y., Kryukov, O., & Cohen, S. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.11.008 · Cited by 170
Yu, Z., McKnight, T. E., Ericson, M. N., Melechko, A. V., Simpson, M. L., & Morrison, B. (2007) · Nano Letters · doi:10.1021/nl070291a · Cited by 129
Xu, T., Molnar, P., Gregory, C., Das, M., Boland, T., & Hickman, J. J. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.04.047 · Cited by 125
Methods for Neural Ensemble Recordings
(2007) · CRC Press eBooks · doi:10.1201/9781420006414 · Cited by 124
Timko, B. P., Cohen-Karni, T., Qing, Q., Tian, B., & Lieber, C. M. (2010) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2009.2031807 · Cited by 114
Self-citationCho, S.-H., Lu, H. M., Cauller, L., Romero-Ortega, M. I., Lee, J.-B., & Hughes, G. A. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.2006261 · Cited by 112
Thin-Film Multiple Electrode Probes: Possibilities and Limitations
Prohaska, O. J., Olcaytug, F., Pfundner, P., & Dragaun, H. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325894 · Cited by 103
Hanley, P. J., Young, A. A., LeGrice, I. J., Edgar, S. G., & Loiselle, D. S. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.0831s.x · Cited by 84
Resident Neuroelectrochemical Interfacing Using Carbon Nanofiber Arrays
McKnight, T. E., Melechko, A. V., Fletcher, B. L., Jones, S., Hensley, D. K., Peckys, D. B., Griffin, G. D., Simpson, M. L., & Ericson, M. N. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp056467j · Cited by 55
Wang, M.-F., Maleki, T., & Ziaie, B. (2008) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2008.926138 · Cited by 14
Research works printed but not linked: 1
- Zipes, D. P. & Jalife, J. Cardiac Electrophysiology: From Cell to Bedside 5th edn (Saunders, 2009).
Cited by
Injectable, Cellular-Scale Optoelectronics with Applications for Wireless Optogenetics
Kim, T.-I., McCall, J. G., Jung, Y. H., Huang, X., Siuda, E. R., Li, Y., Song, J., Song, Y. M., Pao, H. A., Kim, R.-H., et al. (2013) · Science · doi:10.1126/science.1232437 · Cited by 1,174
Fractal design concepts for stretchable electronics
Fan, J. A., Yeo, W.-H., Su, Y., Hattori, Y., Lee, W., Jung, S.-Y., Zhang, Y., Liu, Z., Cheng, H., Falgout, L., et al. (2014) · Nature Communications · doi:10.1038/ncomms4266 · Cited by 1,088
“square, (2) thick mesh, (3) thin mesh, (4) horizontal and vertical stripes separated by a spacer, (5) Peano curve, (6) Hilbert curve, (7) Serpentine Greek”
BackgroundFunctional and Biomimetic Materials for Engineering of the Three-Dimensional Cell Microenvironment
Huang, G., Li, F., Zhao, X., Ma, Y., Li, Y., Lin, M., Jin, G., Lu, T. J., Genin, G. M., & Xu, F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00094 · Cited by 825
Novel electrode technologies for neural recordings
Hong, G., & Lieber, C. M. (2019) · Nature Reviews Neuroscience · doi:10.1038/s41583-019-0140-6 · Cited by 695
Self-citationSyringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Self-citation
Metadata
- Authors
- Tian, B., Liu, J., Dvir, T., Jin, L., Tsui, J. H., Qing, Q., Suo, Z., Langer, R., Kohane, D. S., & Lieber, C. M.
- Affiliations
- Harvard University (US)
- Boston Children's Hospital (US)
- Corresponding author
- Kohane, Daniel S.
- Lieber, Charles M.
- ORCID
- Venue
- Nature Materials
- Published
- 2012-08-26
- Volume
- 11
- Issue
- 11
- Pages
- 986-994
- ISSN
- 1476-1122 (ISSN-L)
- 1476-4660
- PMC
- PMC3623694
- OpenAlex
- W1566118744
- Semantic Scholar
- a2e3dd875e3921aac870aa425019584caf823e20
- Cited by
- 20
- References
- 43
- Citations by year
- 2025: 2 · 2023: 6 · 2022: 1 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 3 · 2014: 2 · 2013: 2
- FWCI
- 0.53
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Nature Materials (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion)
- PMC
- Funders
- National Institutes of Health (5r01de016516-10, DP1OD003900)
- National Institute of General Medical Sciences (GM073626, R01GM073626)
- National Institute of Dental and Craniofacial Research (DE016516, R01-DE016516, DE013023, R01DE013023)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Nanowire Synthesis and Applications
- Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
- Keywords
- macroporous scaffolds, 3D biomaterials, vascular smooth muscle, drug response, pH sensing, regenerative medicine
- MeSH terms
- Biocompatible Materials, Humans, Muscle, Smooth, Vascular, Silicon, Transistors, Electronic, Porosity, Tissue Engineering, Nanotechnology, Nanowires, Tissue Scaffolds
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.