The DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Optical magnetometry
Open accessAbstract
Some of the most sensitive methods of measuring magnetic fields utilize interactions of resonant light with atomic vapor. Recent developments in this vibrant field are improving magnetometers in many traditional areas such as measurement of geomagnetic anomalies and magnetic fields in space, and are opening the door to new ones, including, dynamical measurements of bio-magnetic fields, detection of nuclear magnetic resonance (NMR), magnetic-resonance imaging (MRI), inertial-rotation sensing, magnetic microscopy with cold atoms, and tests of fundamental symmetries of Nature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Single tone parameter estimation from discrete-time observations
Rife, D., & Boorstyn, R. (1974) · IEEE Transactions on Information Theory · doi:10.1109/tit.1974.1055282 · Cited by 1,930
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Self-citation1fnoise and other slow, nonexponential kinetics in condensed matter
Weissman, M. B. (1988) · Reviews of Modern Physics · doi:10.1103/revmodphys.60.537 · Cited by 1,370
Improved Experimental Limit on the Electric Dipole Moment of the Neutron
Baker, C. A., Doyle, D. D., Geltenbort, P., Green, K., van der Grinten, M. G. D., Harris, P. G., Iaydjiev, P., Ivanov, S. N., May, D. J. R., Pendlebury, J. M., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.131801 · Cited by 1,311
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Self-citationElectric dipole moments as probes of new physics
Pospelov, M., & Ritz, A. (2005) · Annals of Physics · doi:10.1016/j.aop.2005.04.002 · Cited by 966
Resonant nonlinear magneto-optical effects in atoms
Budker, D., Gawlik, W., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Weis, A. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.1153 · Cited by 809
Self-citationKastler, A. (1950) · Journal de Physique et le Radium · doi:10.1051/jphysrad:01950001106025500 · Cited by 618
Nuclear Spin Gyroscope Based on an Atomic Comagnetometer
Kornack, T. W., Ghosh, R. K., & Romalis, M. V. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.230801 · Cited by 565
Self-citationChip-scale atomic magnetometer
Schwindt, P. D. D., Knappe, S., Shah, V., Hollberg, L., Kitching, J., Liew, L.-A., & Moreland, J. (2004) · Applied Physics Letters · doi:10.1063/1.1839274 · Cited by 481
Magnetoencephalography with an atomic magnetometer
Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2392722 · Cited by 441
Self-citationIdentification of a Dynamic Atmosphere at Enceladus with the Cassini Magnetometer
Dougherty, M. K., Khurana, K. K., Neubauer, F. M., Russell, C. T., Saur, J., Leisner, J. S., & Burton, M. E. (2006) · Science · doi:10.1126/science.1120985 · Cited by 408
SQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Optically Driven Spin Precession
Bell, W. E., & Bloom, A. L. (1961) · Physical Review Letters · doi:10.1103/physrevlett.6.280 · Cited by 366
Sensitive magnetometry based on nonlinear magneto-optical rotation
Budker, D., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Zolotorev, M. (2000) · Physical Review A · doi:10.1103/physreva.62.043403 · Cited by 335
Self-citationSpin-Exchange Shift and Narrowing of Magnetic Resonance Lines in Optically Pumped Alkali Vapors
Happer, W., & Tang, H. (1973) · Physical Review Letters · doi:10.1103/physrevlett.31.273 · Cited by 323
Unshielded three-axis vector operation of a spin-exchange-relaxation-free atomic magnetometer
Seltzer, S. J., & Romalis, M. V. (2004) · Applied Physics Letters · doi:10.1063/1.1814434 · Cited by 320
Self-citationNew Limit on the Permanent Electric Dipole Moment of199Hg
Romalis, M. V., Griffith, W. C., Jacobs, J. P., & Fortson, E. N. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.2505 · Cited by 320
Self-citationTunable Atomic Magnetometer for Detection of Radio-Frequency Magnetic Fields
Savukov, I. M., Seltzer, S. J., Romalis, M. V., & Sauer, K. L. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.063004 · Cited by 313
Self-citationLimit on Lorentz and CPT Violation of the Neutron Using a Two-Species Noble-Gas Maser
Bear, D., Stoner, R. E., Walsworth, R. L., Kostelecký, V. A., & Lane, C. D. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.5038 · Cited by 309
Feedback for physicists: A tutorial essay on control
Bechhoefer, J. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.783 · Cited by 300
Principles of Operation of the Rubidium Vapor Magnetometer
Bloom, A. L. (1962) · Applied Optics · doi:10.1364/ao.1.000061 · Cited by 282
Optical Detection of Magnetic Resonance in Alkali Metal Vapor
Bell, W. E., & Bloom, A. L. (1957) · Physical Review · doi:10.1103/physrev.107.1559 · Cited by 268
NMR Detection with an Atomic Magnetometer
Savukov, I. M., & Romalis, M. V. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.123001 · Cited by 250
Self-citationEffective Operator Formalism in Optical Pumping
Happer, W., & Mathur, B. S. (1967) · Physical Review · doi:10.1103/physrev.163.12 · Cited by 248
High-Resolution Magnetometry with a Spinor Bose-Einstein Condensate
Vengalattore, M., Higbie, J. M., Leslie, S. R., Guzman, J., Sadler, L. E., & Stamper-Kurn, D. M. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.200801 · Cited by 246
Effects of spin-exchange collisions in a high-density alkali-metal vapor in low magnetic fields
Savukov, I. M., & Romalis, M. V. (2005) · Physical Review A · doi:10.1103/physreva.71.023405 · Cited by 232
Self-citationModulation of a Light Beam by Precessing Absorbing Atoms
Dehmelt, H. G. (1957) · Physical Review · doi:10.1103/physrev.105.1924 · Cited by 227
Cassini Magnetometer Observations During Saturn Orbit Insertion
Dougherty, M. K., Achilleos, N., Andre, N., Arridge, C. S., Balogh, A., Bertucci, C., Burton, M. E., Cowley, S. W. H., Erdos, G., Giampieri, G., et al. (2005) · Science · doi:10.1126/science.1106098 · Cited by 223
New limits on the electron electric dipole moment from cesium
Murthy, S. A., Krause, D., Li, Z. L., & Hunter, L. R. (1989) · Physical Review Letters · doi:10.1103/physrevlett.63.965 · Cited by 222
Application of superconducting quantum interference devices to nuclear magnetic resonance
Greenberg, Y. S. (1998) · Reviews of Modern Physics · doi:10.1103/revmodphys.70.175 · Cited by 214
A laser-pumped magnetometer for the mapping of human cardiomagnetic fields
Bison, G., Wynands, R., & Weis, A. (2003) · Applied Physics B: Lasers and Optics · doi:10.1007/s00340-003-1120-z · Cited by 185
Detection of very weak magnetic fields (10−9gauss) by 87Rb zero-field level crossing resonances
Dupont-Roc, J., Haroche, S., & Cohen-Tannoudji, C. (1969) · Physics Letters A · doi:10.1016/0375-9601(69)90480-0 · Cited by 182
Subfemtotesla radio-frequency atomic magnetometer for detection of nuclear quadrupole resonance
Lee, S.-K., Sauer, K. L., Seltzer, S. J., Alem, O., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2390643 · Cited by 176
Self-citationClinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174
Magnetic resonance imaging with an optical atomic magnetometer
Xu, S., Yashchuk, V. V., Donaldson, M. H., Rochester, S. M., Budker, D., & Pines, A. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0605396103 · Cited by 168
Self-citationA high-sensitivity laser-pumped Mx magnetometer
Groeger, S., Bison, G., Schenker, J.-L., Wynands, R., & Weis, A. (2006) · The European Physical Journal D · doi:10.1140/epjd/e2006-00037-y · Cited by 164
Images of Interlayer Josephson Vortices in Tl 2 Ba 2 CuO 6+ δ
Moler, K. A., Kirtley, J. R., Hinks, D. G., Li, T. W., & Xu, M. (1998) · Science · doi:10.1126/science.279.5354.1193 · Cited by 156
Can a Quantum Nondemolition Measurement Improve the Sensitivity of an Atomic Magnetometer?
Auzinsh, M. P., Budker, D., Kimball, D. F. J., Rochester, S., Stalnaker, J. E., Sushkov, A. O., & Yashchuk, V. V. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.173002 · Cited by 153
Self-citationDetection of NMR signals with a radio-frequency atomic magnetometer
Savukov, I., Seltzer, S. J., & Romalis, M. V. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.12.012 · Cited by 153
Self-citationNew Limits on Local Lorentz Invariance from Hg and Cs Magnetometers
Berglund, C. J., Hunter, L. R., Krause, Jr., Prigge, E. O., Ronfeldt, M. S., & Lamoreaux, S. K. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.1879 · Cited by 151
Light narrowing of rubidium magnetic-resonance lines in high-pressure optical-pumping cells
Appelt, S., Baranga, A. B.-A., Young, A. R., & Happer, W. (1999) · Physical Review A · doi:10.1103/physreva.59.2078 · Cited by 142
Low-noise high-density alkali-metal scalar magnetometer
Smullin, S., Savukov, I., Vasilakis, G., Ghosh, R. K., & Romalis, M. V. (2009) · Physical Review A · doi:10.1103/physreva.80.033420 · Cited by 140
Self-citationParametric modulation of an atomic magnetometer
Li, Z., Wakai, R. T., & Walker, T. G. (2006) · Applied Physics Letters · doi:10.1063/1.2357553 · Cited by 133
Quantum limit of optical magnetometry in the presence of ac Stark shifts
Fleischhauer, M., Matsko, A. B., & Scully, M. O. (2000) · Physical Review A · doi:10.1103/physreva.62.013808 · Cited by 129
Limits on Spin-Mass Couplings within the Axion Window
Youdin, A. N., D. Krause, Jr., Jagannathan, K., Hunter, L. R., & Lamoreaux, S. K. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.2170 · Cited by 123
Nonlinear magneto-optical rotation with frequency-modulated light in the geophysical field range
Acosta, V. M., Ledbetter, M. P., Rochester, S., Budker, D., Kimball, D. F. J., Hovde, D. C., Gawlik, W., Pustelny, S., Zachorowski, J., & Yashchuk, V. V. (2006) · Physical Review A · doi:10.1103/physreva.73.053404 · Cited by 122
Self-citationDetection of the Static Magnetic Field Produced by the Oriented Nuclei of Optically Pumped He3 Gas
Cohen-Tannoudji, C. N., Dupont-Roc, J., Haroche, S., & Laloë, F. (1969) · Physical Review Letters · doi:10.1103/physrevlett.22.758 · Cited by 116
Picotesla magnetometry with coherent dark states
Stähler, M., Knappe, S. A., Affolderbach, C., Kemp, W., & Wynands, R. (2001) · Europhysics Letters (EPL) · doi:10.1209/epl/i2001-00245-y · Cited by 104
Sensing electric and magnetic fields with Bose-Einstein condensates
Wildermuth, S., Hofferberth, S., Lesanovsky, I., Groth, S., Krüger, P., Schmiedmayer, J., & Bar‐Joseph, I. (2006) · Applied Physics Letters · doi:10.1063/1.2216932 · Cited by 103
Magnetometry with millimeter-scale antirelaxation-coated alkali-metal vapor cells
Balabas, M. V., Budker, D., Kitching, J. E., Schwindt, P. D. D., & Stalnaker, J. E. (2006) · Journal of the Optical Society of America B · doi:10.1364/josab.23.001001 · Cited by 93
Self-citationScanning SQUID microscopy of integrated circuits
Chatraphorn, S., Fleet, E. F., Wellstood, F. C., Knauss, L. A., & Eiles, T. M. (2000) · Applied Physics Letters · doi:10.1063/1.126327 · Cited by 91
Hyperpolarized Xenon Nuclear Spins Detected by Optical Atomic Magnetometry
Yashchuk, V. V., Granwehr, J., Kimball, D. F. J., Rochester, S., Trabesinger, A. H., Urban, J. T., Budker, D., & Pines, A. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.160801 · Cited by 86
Self-citationThe Nuclear Magnetic Resonance Gyroscope: a Review
Woodman, K. F., Franks, P. W., & Richards, M. D. (1987) · Journal of Navigation · doi:10.1017/s037346330000062x · Cited by 75
Influence of magnetic-field inhomogeneity on nonlinear magneto-optical resonances
Pustelny, S., Kimball, D. F. J., Rochester, S., Yashchuk, V. V., & Budker, D. (2006) · Physical Review A · doi:10.1103/physreva.74.063406 · Cited by 74
Self-citationOn the calibration of a vectorial 4He pumped magnetometer
Gravrand, O., Khokhlov, A., Mouël, J. L., & Léger, J. (2014) · Earth Planets and Space · doi:10.1186/bf03351692 · Cited by 67
Detection of radio-frequency magnetic fields using nonlinear magneto-optical rotation
Ledbetter, M. P., Acosta, V. M., Rochester, S., Budker, D., Pustelny, S., & Yashchuk, V. V. (2007) · Physical Review A · doi:10.1103/physreva.75.023405 · Cited by 67
Self-citationSuppression of Spin Projection Noise in Broadband Atomic Magnetometry
Geremia, J. M., Stockton, J. K., & Mabuchi, H. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.203002 · Cited by 62
Comparison of discharge lamp and laser pumped cesium magnetometers
Groeger, S., Pazgalev, A. S., & Weis, A. (2005) · Applied Physics B · doi:10.1007/s00340-005-1773-x · Cited by 60
Robust, high-speed, all-optical atomic magnetometer
Higbie, J. M., Corsini, E., & Budker, D. (2006) · Review of Scientific Instruments · doi:10.1063/1.2370597 · Cited by 58
Self-citationSelf-oscillating rubidium magnetometer using nonlinear magneto-optical rotation
Schwindt, P. D. D., Hollberg, L. W., & Kitching, J. E. (2005) · Review of Scientific Instruments · doi:10.1063/1.2136885 · Cited by 57
Xu, S., Rochester, S., Yashchuk, V. V., Donaldson, M. H., & Budker, D. (2006) · Review of Scientific Instruments · doi:10.1063/1.2336087 · Cited by 53
Self-citationHigh-sensitivity helium resonance magnetometers
McGregor, D. D. (1987) · Review of Scientific Instruments · doi:10.1063/1.1139609 · Cited by 48
Sensitivity of condensed-matter P - and T -violation experiments
Budker, D., Lamoreaux, S. K., Sushkov, A. O., & Sushkov, O. P. (2006) · Physical Review A · doi:10.1103/physreva.73.022107 · Cited by 37
Self-citationExperimental demonstration of the sensitivity of an optically pumped quantum magnetometer
Alexandrov, E. B., Balabas, M. V., Vershovskii, A. K., & Pazgalev, A. S. (2004) · Technical Physics · doi:10.1134/1.1767891 · Cited by 35
Robust, High-speed, All-Optical Atomic Magnetometer
Higbie, J. M., Corsini, E., & Budker, D. (2006) · CERN Document Server (European Organization for Nuclear Research) · Cited by 34
Self-citationMagnetometer based on the opto-electronic microwave oscillator
Matsko, A. B., Strekalov, D., & Maleki, L. (2004) · Optics Communications · doi:10.1016/j.optcom.2004.11.047 · Cited by 27
Zhao, K., & Wu, Z. (2006) · Applied Physics Letters · doi:10.1063/1.2424657 · Cited by 25
[Recording of human magnetic fields].
Mn, L., Kozlov, A. N., Korinevskiĭ, A. V., Vp, M., & Sinel'nikova, S. E. (1978) · PubMed · Cited by 12
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Sensitivity optimization for NV-diamond magnetometry
Barry, J. F., Schloss, J. M., Bauch, E., Turner, M. J., Hart, C. A., Pham, L. M., & Walsworth, R. L. (2020) · Reviews of Modern Physics · doi:10.1103/revmodphys.92.015004 · Cited by 1,247
Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Dang, H. B., Maloof, A. C., & Romalis, M. V. (2010) · Applied Physics Letters · doi:10.1063/1.3491215 · Cited by 891
Self-citationOptical magnetic detection of single-neuron action potentials using quantum defects in diamond
Barry, J. F., Turner, M. J., Schloss, J. M., Glenn, D. R., Song, Y., Lukin, M. D., Park, H., & Walsworth, R. L. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1601513113 · Cited by 637
Kitching, J. (2018) · Applied Physics Reviews · doi:10.1063/1.5026238 · Cited by 621
Metadata
- Authors
- Budker, D., & Romalis, M.
- Venue
- Nature Physics
- Published
- 2007-04
- Volume
- 3
- Issue
- 4
- Pages
- 227-234
- ISSN
- 1745-2473 (ISSN-L)
- 1745-2481
- OpenAlex
- W2766839228
- Cited by
- 1,916
- References
- 71
- FWCI
- 27.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.