Revisiting lab-on-a-chip technology for drug discovery
Open accessAbstract
The field of microfluidics or lab-on-a-chip technology aims to improve and extend the possibilities of bioassays, cell biology and biomedical research based on the idea of miniaturization. Microfluidic systems allow more accurate modelling of physiological situations for both fundamental research and drug development, and enable systematic high-volume testing for various aspects of drug discovery. Microfluidic systems are in development that not only model biological environments but also physically mimic biological tissues and organs; such 'organs on a chip' could have an important role in expediting early stages of drug discovery and help reduce reliance on animal testing. This Review highlights the latest lab-on-a-chip technologies for drug discovery and discusses the potential for future developments in this field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delivery of siRNA to the mouse brain by systemic injection of targeted exosomes
Alvarez-Erviti, L., Seow, Y., Yin, H., Betts, C., Lakhal, S., & Wood, M. J. A. (2011) · Nature Biotechnology · doi:10.1038/nbt.1807 · Cited by 4,930
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
How to improve R&D productivity: the pharmaceutical industry's grand challenge
Paul, S. M., Mytelka, D. S., Dunwiddie, C. T., Persinger, C. C., Munos, B. H., Lindborg, S. R., & Schacht, A. L. (2010) · Nature Reviews Drug Discovery · doi:10.1038/nrd3078 · Cited by 3,566
How many drug targets are there?
Overington, J. P., Al-Lazikani, B., & Hopkins, A. L. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd2199 · Cited by 3,505
Miniaturized total chemical analysis systems: A novel concept for chemical sensing
Manz, A., Graber, N., & Widmer, H. M. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80209-i · Cited by 3,122
Self-citationTeh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Creation of a Bacterial Cell Controlled by a Chemically Synthesized Genome
Gibson, D. G., Glass, J. I., Lartigue, C., Noskov, V. N., Chuang, R.-Y., Algire, M. A., Benders, G. A., Montague, M. G., Ma, L., Moodie, M. M., et al. (2010) · Science · doi:10.1126/science.1190719 · Cited by 2,638
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Monodisperse Double Emulsions Generated from a Microcapillary Device
Utada, A. S., Lorenceau, E., Link, D. R., Kaplan, P. D., Stone, H. A., & Weitz, D. A. (2005) · Science · doi:10.1126/science.1109164 · Cited by 2,248
Dynamic Pattern Formation in a Vesicle-Generating Microfluidic Device
Thorsen, T., Roberts, R. W., Arnold, F. H., & Quake, S. R. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4163 · Cited by 2,051
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Self-citationIsolation of circulating tumor cells using a microvortex-generating herringbone-chip
Stott, S. L., Hsu, C.-H., Tsukrov, D. I., Yu, M., Miyamoto, D. T., Waltman, B. A., Rothenberg, S. M., Shah, A. M., Smas, M. E., Korir, G. K., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1012539107 · Cited by 1,634
Cho, S. K., Moon, H., & Kim, C.-J. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.807467 · Cited by 1,598
Programming cells by multiplex genome engineering and accelerated evolution
Wang, H. H., Isaacs, F. J., Carr, P. A., Sun, Z. Z., Xu, G., Forest, C. R., & Church, G. M. (2009) · Nature · doi:10.1038/nature08187 · Cited by 1,529
Abbott, A. (2003) · Nature · doi:10.1038/424870a · Cited by 1,234
Droplet microfluidic technology for single-cell high-throughput screening
Brouzes, E., Medkova, M., Savenelli, N., Marran, D., Twardowski, M., Hutchison, J. B., Rothberg, J. M., Link, D. R., Perrimon, N., & Samuels, M. L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903542106 · Cited by 1,069
High-throughput 3D spheroid culture and drug testing using a 384 hanging drop array
Tung, Y.-C., Hsiao, A. Y., Allen, S. G., Torisawa, Y.-S., Ho, M., & Takayama, S. (2011) · The Analyst · doi:10.1039/c0an00609b · Cited by 969
Baret, J.-C., Miller, O. J., Taly, V., Ryckelynck, M., El-Harrak, A., Frenz, L., Rick, C., Samuels, M. L., Hutchison, J. B., Agresti, J. J., et al. (2009) · Lab on a Chip · doi:10.1039/b902504a · Cited by 951
The use of 3-d cultures for high-throughput screening: the multicellular spheroid model.
Kunz-Schughart, L. A., Freyer, J. P., Hofstaedter, F., & Ebner, R. (2004) · SLAS DISCOVERY · doi:10.1177/1087057104265040 · Cited by 797
Multifunctional Encoded Particles for High-Throughput Biomolecule Analysis
Pregibon, D. C., Toner, M., & Doyle, P. S. (2007) · Science · doi:10.1126/science.1134929 · Cited by 726
Acoustic tweezers: patterning cells and microparticles using standing surface acoustic waves (SSAW)
Shi, J., Ahmed, D., Mao, X., Lin, S.-C. S., Lawit, A., & Huang, T. J. (2009) · Lab on a Chip · doi:10.1039/b910595f · Cited by 723
Self-citationClausell-Tormos, J., Lieber, D., Baret, J.-C., El-Harrak, A., Miller, O. J., Frenz, L., Blouwolff, J., Humphry, K. J., Köster, S., Duan, H., et al. (2008) · Chemistry & Biology · doi:10.1016/j.chembiol.2008.04.004 · Cited by 720
Nazarenko, I., Rana, S., Baumann, A., McAlear, J., Hellwig, A., Trendelenburg, M., Lochnit, G., Preissner, K. T., & Zöller, M. (2010) · Cancer Research · doi:10.1158/0008-5472.can-09-2470 · Cited by 686
The influence of lead discovery strategies on the properties of drug candidates
Keserü, G. M., & Makara, G. M. (2009) · Nature Reviews Drug Discovery · doi:10.1038/nrd2796 · Cited by 628
Systems biology in drug discovery
Butcher, E. C., Berg, E. L., & Kunkel, E. J. (2004) · Nature Biotechnology · doi:10.1038/nbt1017 · Cited by 605
Synthetic Gene Networks That Count
Friedland, A. E., Lu, T. K., Wang, X., Shi, D., Church, G., & Collins, J. J. (2009) · Science · doi:10.1126/science.1172005 · Cited by 587
A systems approach to measuring the binding energy landscapes of transcription factors.
Maerkl, S. J., & Quake, S. R. (2007) · Science · doi:10.1126/science.1131007 · Cited by 584
Continuous particle separation in a microfluidic channel via standing surface acoustic waves (SSAW)
Shi, J., Huang, H., Stratton, Z., Huang, Y., & Huang, T. J. (2009) · Lab on a Chip · doi:10.1039/b915113c · Cited by 547
Self-citationQuantitative and sensitive detection of rare mutations using droplet-based microfluidics
Pekin, D., Skhiri, Y., Baret, J.-C., Le Corre, D., Mazutis, L., Ben Salem, C., Millot, F., El Harrak, A., Hutchison, J. B., Larson, J. W., et al. (2011) · Lab on a Chip · doi:10.1039/c1lc20128j · Cited by 540
He, M., Edgar, J. S., Jeffries, G. D. M., Lorenz, R. M., Shelby, J. P., & Chiu, D. T. (2005) · Analytical Chemistry · doi:10.1021/ac0480850 · Cited by 518
Controlled encapsulation of single-cells into monodisperse picolitre drops
Edd, J. F., Di Carlo, D., Humphry, K. J., Köster, S., Irimia, D., Weitz, D. A., & Toner, M. (2008) · Lab on a Chip · doi:10.1039/b805456h · Cited by 511
ON THE PERMANENT LIFE OF TISSUES OUTSIDE OF THE ORGANISM
Carrel, A. (1912) · Journal of Experimental Medicine · doi:10.1084/jem.15.5.516 · Cited by 492
Microfluidic cell culture systems for drug research
Wu, M.-H., Huang, S.-B., & Lee, G.-B. (2010) · Lab on a Chip · doi:10.1039/b921695b · Cited by 432
Sung, J. H., & Shuler, M. L. (2009) · Lab on a Chip · doi:10.1039/b901377f · Cited by 431
Latest Developments in Micro Total Analysis Systems
Arora, A., Simone, G., Salieb-Beugelaar, G. B., Kim, J. T., & Manz, A. (2010) · Analytical Chemistry · doi:10.1021/ac100969k · Cited by 421
Self-citationSurface acoustic wave (SAW) directed droplet flow in microfluidics for PDMS devices
Franke, T., Abate, A. R., Weitz, D. A., & Wixforth, A. (2009) · Lab on a Chip · doi:10.1039/b906819h · Cited by 369
A study of the mechanics of gastrulation
Holtfreter, J. (1944) · Journal of Experimental Zoology · doi:10.1002/jez.1400950203 · Cited by 352
Planar chip device for PCR and hybridization with surface acoustic wave pump
Guttenberg, Z., Müller, H., Habermüller, H., Geisbauer, A., Pipper, J., Felbel, J., Kielpinski, M., Scriba, J., & Wixforth, A. (2005) · Lab Chip · doi:10.1039/b412712a · Cited by 349
Unveiling the role of network and systems biology in drug discovery
Pujol, A., Mosca, R., Farrés, J., & Aloy, P. (2010) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2009.11.006 · Cited by 346
The Role of Body-on-a-Chip Devices in Drug and Toxicity Studies
Esch, M. B., King, T. L., & Shuler, M. L. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124629 · Cited by 328
High-throughput in vivo vertebrate screening
Pardo-Martin, C., Chang, T.-Y., Koo, B. K., Gilleland, C. L., Wasserman, S. C., & Yanik, M. F. (2010) · Nature Methods · doi:10.1038/nmeth.1481 · Cited by 325
Kang, L., Chung, B. G., Langer, R., & Khademhosseini, A. (2008) · Drug Discovery Today · doi:10.1016/j.drudis.2007.10.003 · Cited by 325
Single cell trapping and DNA damage analysis using microwell arrays
Wood, D. K., Weingeist, D. M., Bhatia, S. N., & Engelward, B. P. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1004056107 · Cited by 263
Darhuber, A. A., Valentino, J. P., Troian, S. M., & Wagner, S. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820267 · Cited by 240
Einav, S., Gerber, D., Bryson, P. D., Sklan, E. H., Elazar, M., Maerkl, S. J., Glenn, J. S., & Quake, S. R. (2008) · Nature Biotechnology · doi:10.1038/nbt.1490 · Cited by 235
Lutolf, M. P., & Blau, H. M. (2009) · Advanced Materials · doi:10.1002/adma.200802582 · Cited by 222
Microvalve-actuated precise control of individual droplets in microfluidic devices
Zeng, S., Li, B., Su, X., Qin, J., & Lin, B. (2009) · Lab on a Chip · doi:10.1039/b821803j · Cited by 214
Lifespan-on-a-chip: microfluidic chambers for performing lifelong observation of C. elegans
Hulme, S. E., Shevkoplyas, S. S., McGuigan, A. P., Apfeld, J., Fontana, W., & Whitesides, G. M. (2010) · Lab Chip · doi:10.1039/b919265d · Cited by 213
Mao, X., Lin, S.-C. S., Dong, C., & Huang, T. J. (2009) · Lab on a Chip · doi:10.1039/b820138b · Cited by 205
Self-citationvan Midwoud, P. M., Merema, M. T., Verpoorte, E., & Groothuis, G. M. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00043d · Cited by 203
A microdroplet dilutor for high-throughput screening
Niu, X., Gielen, F., Edel, J. B., & deMello, A. J. (2011) · Nature Chemistry · doi:10.1038/nchem.1046 · Cited by 199
Baker, M. (2011) · Nature · doi:10.1038/471661a · Cited by 188
Mao, X., Waldeisen, J. R., & Huang, T. J. (2007) · Lab on a Chip · doi:10.1039/b711155j · Cited by 184
Self-citationThe beautiful cell: high-content screening in drug discovery
Bickle, M. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3788-3 · Cited by 176
Micropilot: automation of fluorescence microscopy–based imaging for systems biology
Conrad, C., Wünsche, A., Tan, T. H., Bulkescher, J., Sieckmann, F., Verissimo, F., Edelstein, A., Walter, T., Liebel, U., Pepperkok, R., et al. (2011) · Nature Methods · doi:10.1038/nmeth.1558 · Cited by 167
From Microdroplets to Microfluidics: Selective Emulsion Separation in Microfluidic Devices
Fidalgo, L. M., Whyte, G., Bratton, D., Kaminski, C. F., Abell, C., & Huck, W. T. S. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200704903 · Cited by 165
A microfluidic platform for probing small artery structure and function
Günther, A., Yasotharan, S., Vagaon, A., Lochovsky, C., Pinto, S., Yang, J., Lau, C. H., Voigtlaender‐Bolz, J., & Bolz, S. (2010) · Lab on a Chip · doi:10.1039/c004675b · Cited by 156
Stem Cells and Drug Discovery: The Beginning of a New Era?
Rubin, L. L. (2008) · Cell · doi:10.1016/j.cell.2008.02.010 · Cited by 145
A microfluidic array for large-scale ordering and orientation of embryos
Chung, K., Kim, Y., Kanodia, J., Gong, E. S., Shvartsman, S. Y., & Lu, H. (2010) · Nature Methods · doi:10.1038/nmeth.1548 · Cited by 144
A Sponge Matrix Method for Tissue Culture. Formation of Organized Aggregates of Cells in Vitro 2
Leighton, J. (1951) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/12.3.545 · Cited by 143
Microscopic imaging techniques for drug discovery
Bullen, A. (2007) · Nature Reviews Drug Discovery · doi:10.1038/nrd2446 · Cited by 140
Thermoforming of Film‐Based Biomedical Microdevices
Truckenmüller, R. K., Giselbrecht, S., Rivron, N. C., Gottwald, E., Saile, V., van den Berg, A., Weßling, M., & van Blitterswijk, C. (2011) · Advanced Materials · doi:10.1002/adma.201003538 · Cited by 131
Self-citationDroplet microfluidics with magnetic beads: a new tool to investigate drug–protein interactions
Lombardi, D., & Dittrich, P. S. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4302-7 · Cited by 117
Microfluidic devices for in vitro studies on liver drug metabolism and toxicity
van Midwoud, P. M., Verpoorte, E., & Groothuis, G. M. M. (2011) · Integrative Biology · doi:10.1039/c0ib00119h · Cited by 115
Fundamentals and applications of immobilized microfluidic enzymatic reactors
Matosevic, S., Szita, N., & Baganz, F. (2011) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.2564 · Cited by 102
A microfluidic oligonucleotide synthesizer
Lee, C.-C., Snyder, T. M., & Quake, S. R. (2010) · Nucleic Acids Research · doi:10.1093/nar/gkq092 · Cited by 94
Real-Time Microfluidic System for Studying Mammalian Cells in 3D Microenvironments
Lii, J., Hsu, W., Parsa, H., Das, A., Rouse, R., & Sia, S. K. (2008) · Analytical Chemistry · doi:10.1021/ac8000034 · Cited by 91
He, M., Kuo, J. S., & Chiu, D. T. (2005) · Applied Physics Letters · doi:10.1063/1.1997280 · Cited by 90
Automated microfluidic compact disc (CD) cultivation system of Caenorhabditis elegans
Kim, N., Dempsey, C. M., Zoval, J. V., Sze, J.-Y., & Madou, M. J. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.06.026 · Cited by 88
High-Throughput Methods to Define Complex Stem Cell Niches
Kobel, S., & Lütolf, M. P. (2010) · BioTechniques · doi:10.2144/000113401 · Cited by 79
Opportunities for microfluidic technologies in synthetic biology
Gulati, S., Rouilly, V., Niu, X., Chappell, J., Kitney, R. I., Edel, J. B., Freemont, P. S., & deMello, A. J. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0083.focus · Cited by 78
Biomaterials meet microfluidics: building the next generation of artificial niches
Kobel, S., & Lütolf, M. P. (2011) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2011.07.001 · Cited by 77
Engineering Approaches Toward Deconstructing and Controlling the Stem Cell Environment
Edalat, F., Bae, H., Manoucheri, S., Cha, J. M., & Khademhosseini, A. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0452-9 · Cited by 77
Parallel gene synthesis in a microfluidic device
Kong, D. S., Carr, P. A., Chen, L., Zhang, S., & Jacobson, J. M. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm121 · Cited by 71
Geometry and force control of cell function
Freytes, D. O., Wan, L. Q., & Vunjak‐Novakovic, G. (2009) · Journal of Cellular Biochemistry · doi:10.1002/jcb.22355 · Cited by 60
Responsive Microgrooves for the Formation of Harvestable Tissue Constructs
Tekin, H., İnce, G. Ö., Tsinman, T. K., Gleason, K. K., Langer, R., Khademhosseini, A., & Demirel, M. C. (2011) · Langmuir · doi:10.1021/la200183x · Cited by 59
Genomics and proteomics analysis of cultured primary rat hepatocytes
Beigel, J., Fella, K., Kramer, P.-J., Kröger, M., & Hewitt, P. (2007) · Toxicology in Vitro · doi:10.1016/j.tiv.2007.06.019 · Cited by 55
Microtechnologies for membrane protein studies
Suzuki, H., & Takeuchi, S. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1916-0 · Cited by 50
Multiplexed, high-throughput analysis of 3D microtissue suspensions
Chen, A. A., Underhill, G. H., & Bhatia, S. N. (2010) · Integrative Biology · doi:10.1039/c0ib00054j · Cited by 49
The impact of synthetic biology on drug discovery
Weber, W., & Fussenegger, M. (2009) · Drug Discovery Today · doi:10.1016/j.drudis.2009.06.010 · Cited by 47
Stem cell biology and drug discovery
Rubin, L. L., & Haston, K. M. (2011) · BMC Biology · doi:10.1186/1741-7007-9-42 · Cited by 45
Lee, J., Ryu, J., & Park, C. B. (2009) · Analytical Chemistry · doi:10.1021/ac802701z · Cited by 40
Microfluidic Technologies for Synthetic Biology
Parisutham, V., Park, S., Kim, M., Park, J. M., Kim, T., & Lee, S. K. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12063576 · Cited by 38
Hughes, A. J., & Herr, A. E. (2010) · Analytical Chemistry · doi:10.1021/ac100201z · Cited by 36
Pruss, R. M. (2010) · CNS & Neurological Disorders - Drug Targets · doi:10.2174/187152710793237377 · Cited by 23
Cited by
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
25th Anniversary Article: Rational Design and Applications of Hydrogels in Regenerative Medicine
Annabi, N., Tamayol, A., Uquillas, J. A., Akbari, M., Bertassoni, L. E., Cha, C., Camci‐Unal, G., Dokmeci, M. R., Peppas, N. A., & Khademhosseini, A. (2014) · Advanced Materials · doi:10.1002/adma.201303233 · Cited by 1,409
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Surface acoustic wave microfluidics
Ding, X., Li, P., Lin, S.-C. S., Stratton, Z. S., Nama, N., Guo, F., Slotcavage, D., Mao, X., Shi, J., Costanzo, F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50361e · Cited by 926
Self-citation
Metadata
- Authors
- Neužil, P., Giselbrecht, S., Länge, K., Huang, T. J., & Manz, A.
- Venue
- Nature Reviews Drug Discovery
- Published
- 2012-08
- Volume
- 11
- Issue
- 8
- Pages
- 620-632
- ISSN
- 1474-1776 (ISSN-L)
- 1474-1784
- OpenAlex
- W2062409563
- Cited by
- 487
- References
- 87
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.