The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Comparison of Three Bioelectrical Impedance Methods with DXA in Overweight and Obese Men
Abstract
Objective: To compare bioelectrical impedance analysis (BIA) of body composition using three different methods against DXA in overweight and obese men. Research Methods and Procedures: Forty‐three healthy overweight or obese men (ages 25 to 60 years; BMI, 28 to 43 kg/m 2) underwent BIA assessment of body composition using the ImpediMed SFB7 (version 6; ImpediMed, Ltd., Eight Mile Plains, Queensland, Australia) in multifrequency mode (Imp‐MF) and DF50 single‐frequency mode (Imp‐SF) and the Tanita UltimateScale (Tanita Corp., Tokyo, Japan). Validity was assessed by comparison against DXA using linear regression and limits of agreement analysis. Results: All three BIA methods showed good relative agreement with DXA [Imp‐MF: fat mass (FM), r2 = 0.81; fat‐free mass (FFM), r2 = 0.81; percentage body fat (BF%), r2 = 0.69; Imp‐SF: FM, r2 = 0.65; FFM, r2 = 0.76; BF%, r2 = 0.40; Tanita: BF%, r2 = 0.44; all p < 0.001]. Absolute agreement between DXA and Imp‐MF was poor, as indicated by a large bias and wide limits of agreement (bias, ±1.96 standard deviation; FM, −6.6 ± 7.7 kg; FFM, 8.0 ± 7.1 kg; BF%, −7.0 ± 6.6%). Imp‐SF and Tanita exhibited a smaller bias but wide limits of agreement (Imp‐SF: FM, −1.1 ± 8.5 kg; FFM, 2.5 ± 7.9 kg; BF%, −1.7 ± 7.3% Tanita: BF%, 1.2 ± 9.5%). Discussion: Compared with DXA, Imp‐MF produced large bias and wide limits of agreement, and its accuracy estimating body composition in overweight or obese men was poor. Imp‐SF and Tanita demonstrated little bias and may be useful for group comparisons, but their utility for assessment of body composition in individuals is limited.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200 · cited 4×
“al’s height, total body water (TBW) can be estimated by measuring impedance to the flow of a small current (3).”
BackgroundInfluentialAssessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Single prediction equation for bioelectrical impedance analysis in adults aged 20–94 years
Kyle, U. G., Genton, L., Karsegard, L., Slosman, D. O., & Pichard, C. (2001) · Nutrition · doi:10.1016/s0899-9007(00)00553-0 · Cited by 575
(1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.524s · Cited by 549
In vivo validation of whole body composition estimates from dual-energy X-ray absorptiometry
Prior, B. M., Cureton, K. J., Modlesky, C. M., Evans, E. M., Sloniger, M. A., Saunders, M., & Lewis, R. D. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.2.623 · Cited by 317 · cited 1×
“DXA is arguably one of the best reference methods available, having been validated against other methods of body composition analysis, and has been shown to have minimal bias based on age, sex, physical activity level, race, or proportion of body fat (15).”
MethodPreliminary evidence that DEXA provides an accurate assessment of body composition
Kohrt, W. M. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.372 · Cited by 186
Eisenkölbl, J., Kartasurya, M., & Widhalm, K. (2001) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601184 · Cited by 115
Jakicic, J., Wing, R., & Lang, W. (1998) · International Journal of Obesity · doi:10.1038/sj.ijo.0800576 · Cited by 73
Cited by
Assessment methods in human body composition
Lee, S. Y., & Gallagher, D. (2008) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/mco.0b013e32830b5f23 · Cited by 694
“Validity of BIA is also influenced by sex, age, disease state, race or ethnicity [7], and level of fatness in which TBW and relative ECW are greater in obese individuals compared with normal-weight individuals; and type of BIA system in which SF-BIA was found to have better absolute agreement than multifrequency BIA w…”
ResultAchamrah, N., Colange, G., Delay, J., Rimbert, A., Folope, V., Petit, A., Grigioni, S., Déchelotte, P., & Coëffier, M. (2018) · PLoS ONE · doi:10.1371/journal.pone.0200465 · Cited by 337
Lukaski, H. C. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.149 · Cited by 303
Diagnostic accuracy of body mass index to identify obesity in older adults: NHANES 1999–2004
Batsis, J. A., Mackenzie, T. A., Bartels, S. J., Sahakyan, K. R., Somers, V. K., & Lopez-Jimenez, F. (2016) · International Journal of Obesity · doi:10.1038/ijo.2015.243 · Cited by 275
Bosy-Westphal, A., Later, W., Hitze, B., Sato, T., Kossel, E., Glüer, C.-C., Heller, M., & Müller, M. J. (2008) · Obesity Facts · doi:10.1159/000176061 · Cited by 263
Helms, E. R., Aragon, A. A., & Fitschen, P. J. (2014) · Journal of the International Society of Sports Nutrition · doi:10.1186/1550-2783-11-20 · Cited by 178
Søvik, T. T., Aasheim, E. T., Taha, O., Engström, M., Fagerland, M. W., Björkman, S., Kristinsson, J., Birkeland, K. I., Mala, T., & Olbers, T. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-5-201109060-00005 · Cited by 166
An intervention study targeting energy and nutrient intake in worksite cafeterias
Lowe, M. R., Tappe, K. A., Butryn, M. L., Annunziato, R. A., Coletta, M. C., Ochner, C. N., & Rolls, B. J. (2010) · Eating Behaviors · doi:10.1016/j.eatbeh.2010.01.002 · Cited by 117
Savastano, S., Belfiore, A., Di Somma, C., Mauriello, C., Rossi, A., Pizza, G., De Rosa, A., Prestieri, G., Angrisani, L., & Colao, A. (2010) · Obesity Surgery · doi:10.1007/s11695-009-0006-5 · Cited by 100
Smartphone camera based assessment of adiposity: a validation study
Majmudar, M. D., Chandra, S., Yakkala, K., Kennedy, S., Agrawal, A., Sippel, M., Ramu, P., Chaudhri, A., Smith, B., Criminisi, A., et al. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00628-3 · Cited by 75
Xu, L., Cheng, X., Wang, J., Cao, Q., Sato, T., Wang, M., Zhao, X., & Liang, W. (2011) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2011.04.001 · Cited by 73
Becroft, L., Ooi, G., Forsyth, A., King, S., & Tierney, A. (2019) · International Journal of Obesity · doi:10.1038/s41366-018-0285-9 · Cited by 51
Fakhrawi, D. H., Beeson, L., Libanati, C., Feleke, D., Kim, H., Quansah, A., Darnell, A., Lammi-Keefe, C. J., & Cordero-MacIntyre, Z. (2009) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2009.01.004 · Cited by 48
Stratton, M. T., Smith, R. W., Harty, P. S., Rodriguez, C., Johnson, B. A., Dellinger, J. R., Williams, A. D., White, S. J., Benavides, M. L., & Tinsley, G. M. (2021) · European Journal of Clinical Nutrition · doi:10.1038/s41430-020-00811-3 · Cited by 46
Intrinsic motivation in two exercise interventions: associations with fitness and body composition
Thøgersen-Ntoumani, C., Shepherd, S. O., Ntoumanis, N., Wagenmakers, A. J. M., & Shaw, C. S. (2016) · Health Psychology · doi:10.1037/hea0000260 · Cited by 42
Jiménez, A., Omaña, W., Flores, L., Coves, M. J., Bellido, D., Perea, V., & Vidal, J. (2012) · Obesity Surgery · doi:10.1007/s11695-011-0570-3 · Cited by 40
Coëffier, M., El Machkouri, M., L'Huillier, C., Folope, V., Lelandais, H., Grigioni, S., Déchelotte, P., & Achamrah, N. (2022) · Clinical Nutrition · doi:10.1016/j.clnu.2022.07.032 · Cited by 28
Fat-free mass is not lower 24 months postbariatric surgery than nonoperated matched controls
Strain, G. W., Ebel, F., Honohan, J., Gagner, M., Dakin, G. F., Pomp, A., & Gallagher, D. (2017) · Surgery for Obesity and Related Diseases · doi:10.1016/j.soard.2016.03.003 · Cited by 13
Metadata
- Authors
- Pateyjohns, I. R., Brinkworth, G. D., Buckley, J. D., Noakes, M., & Clifton, P. M.
- Venue
- Obesity
- Publisher
- Wiley
- Published
- 2006-11
- Volume
- 14
- Issue
- 11
- Pages
- 2064-2070
- ISSN
- 1930-7381 (ISSN-L)
- 1930-739X
- OpenAlex
- W2094442390
- Cited by
- 187
- References
- 9
- FWCI
- 4.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.