Abstract
Determining the brain perfusion is an important task for diagnosis of vascular diseases such as occlusions and intracerebral haemorrhage. Even after successful diagnosis, there is a high risk of restenosis or rebleeding such that patients need intense attention in the days after treatment. Within this work, we present a diagnostic tomographic imager that allows access to brain perfusion quantitatively in short intervals. The device is based on the magnetic particle imaging technology and is designed for human scale. It is highly sensitive and allows the detection of an iron concentration of 263 pmol Fe ml−1, which is one of the lowest iron concentrations imaged by MPI so far. The imager is self-shielded and can be used in unshielded environments such as intensive care units. In combination with the low technical requirements this opens up a variety of medical applications and would allow monitoring of stroke on intensive care units.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feigin, V. L., Forouzanfar, M. H., Krishnamurthi, R., Mensah, G. A., Connor, M., Bennett, D. A., Moran, A. E., Sacco, R. L., Anderson, L., Truelsen, T., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(13)61953-4 · Cited by 3,899
Tomographic imaging using the nonlinear response of magnetic particles
Gleich, B., & Weizenecker, J. (2005) · Nature · doi:10.1038/nature03808 · Cited by 2,003
Self-citationNoninvasive detection of clinically occult lymph-node metastases in prostate cancer
Harisinghani, M. G., Barentsz, J., Hahn, P. F., Deserno, W. M., Tabatabaei, S., van de Kaa, C. H., de la Rosette, J., & Weissleder, R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022749 · Cited by 1,971
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Three-dimensional real-time in vivo magnetic particle imaging
Weizenecker, J., Gleich, B., Rahmer, J., Dahnke, H., & Borgert, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/l01 · Cited by 651
Self-citationReimer, P., & Balzer, T. (2003) · European Radiology · doi:10.1007/s00330-002-1721-7 · Cited by 614
Multidimensional X-Space Magnetic Particle Imaging
Goodwill, P. W., & Conolly, S. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2125982 · Cited by 319
Zheng, B., Vazin, T., Goodwill, P. W., Conway, A., Verma, A., Ulku Saritas, E., Schaffer, D., & Conolly, S. M. (2015) · Scientific Reports · doi:10.1038/srep14055 · Cited by 274
Magnetic particle imaging: from proof of principle to preclinical applications
Knopp, T., Gdaniec, N., & Möddel, M. (2017) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa6c99 · Cited by 238
Self-citationMagnetic Particle Imaging for Real-Time Perfusion Imaging in Acute Stroke
Ludewig, P., Gdaniec, N., Sedlacik, J., Forkert, N. D., Szwargulski, P., Graeser, M., Adam, G., Kaul, M. G., Krishnan, K. M., Ferguson, R. M., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b05784 · Cited by 224
Self-citationKhandhar, A. P., Keselman, P., Kemp, S. J., Ferguson, R. M., Goodwill, P. W., Conolly, S. M., & Krishnan, K. M. (2017) · Nanoscale · doi:10.1039/c6nr08468k · Cited by 180
Graeser, M., Knopp, T., Szwargulski, P., Friedrich, T., von Gladiss, A., Kaul, M. G., Krishnan, K. M., Ittrich, H., Adam, G., & Buzug, T. M. (2017) · Scientific Reports · doi:10.1038/s41598-017-06992-5 · Cited by 176
Self-citationMagnetostimulation Limits in Magnetic Particle Imaging
Saritas, E. U., Goodwill, P. W., Zhang, G. Z., & Conolly, S. M. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2260764 · Cited by 173
Bulte, J. W. M., Walczak, P., Janowski, M., Krishnan, K. M., Arami, H., Halkola, A., Gleich, B., & Rahmer, J. (2015) · Tomography · doi:10.18383/j.tom.2015.00172 · Cited by 173
Self-citationTrajectory analysis for magnetic particle imaging
Knopp, T., Biederer, S., Sattel, T., Weizenecker, J., Gleich, B., Borgert, J., & Buzug, T. M. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/2/014 · Cited by 171
Self-citationYu, E. Y., Chandrasekharan, P., Berzon, R., Tay, Z. W., Zhou, X. Y., Khandhar, A. P., Ferguson, R. M., Kemp, S. J., Zheng, B., Goodwill, P. W., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b04844 · Cited by 161
Tomographic magnetic particle imaging of cancer targeted nanoparticles
Arami, H., Teeman, E., Troksa, A., Bradshaw, H., Saatchi, K., Tomitaka, A., Gambhir, S. S., Häfeli, U. O., Liggitt, D., & Krishnan, K. M. (2017) · Nanoscale · doi:10.1039/c7nr05502a · Cited by 158
Single-sided device for magnetic particle imaging
Sattel, T. F., Knopp, T., Biederer, S., Gleich, B., Weizenecker, J., Borgert, J., & Buzug, T. M. (2009) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/42/2/022001 · Cited by 151
Self-citationFirst in vivo magnetic particle imaging of lung perfusion in rats
Zhou, X. Y., Jeffris, K. E., Yu, E. Y., Zheng, B., Goodwill, P. W., Nahid, P., & Conolly, S. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa616c · Cited by 139
Salamon, J., Hofmann, M., Jung, C., Kaul, M. G., Werner, F., Them, K., Reimer, R., Nielsen, P., Scheidt, A. V., Adam, G., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0156899 · Cited by 114
Self-citationBristow, M., Simon, J. E., Brown, R. A., Eliasziw, M., Hill, M. D., Coutts, S. B., Frayne, R., Demchuk, A. M., & Mitchell, J. R. (2005) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600135 · Cited by 113
Rahmer, J., Antonelli, A., Sfara, C., Tiemann, B., Gleich, B., Magnani, M., Weizenecker, J., & Borgert, J. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/12/3965 · Cited by 111
Self-citationRahmer, J., Wirtz, D., Bontus, C., Borgert, J., & Gleich, B. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2679099 · Cited by 101
Self-citationSensitivity Enhancement in Magnetic Particle Imaging by Background Subtraction
Them, K., Kaul, M. G., Jung, C., Hofmann, M., Mummert, T., Werner, F., & Knopp, T. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2501462 · Cited by 87
Self-citationDesign analysis of an MPI human functional brain scanner
Mason, E. E., Cooley, C. Z., Cauley, S., Griswold, M. A., Conolly, S., & Wald, L. L. (2016) · International journal on magnetic particle imaging · doi:10.18416/ijmpi.2017.1703008 · Cited by 80
Analog receive signal processing for magnetic particle imaging
Graeser, M., Knopp, T., Grüttner, M., Sattel, T. F., & Buzug, T. M. (2013) · Medical Physics · doi:10.1118/1.4794482 · Cited by 79
Self-citationMulti-color magnetic particle imaging for cardiovascular interventions
Haegele, J., Vaalma, S., Panagiotopoulos, N., Barkhausen, J., VOGT, F. M., Borgert, J., & Rahmer, J. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/16/n415 · Cited by 73
Online reconstruction of 3D magnetic particle imaging data
Knopp, T., & Hofmann, M. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/11/n257 · Cited by 72
Self-citationCooley, C. Z., Mandeville, J. B., Mason, E. E., Mandeville, E. T., & Wald, L. L. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.05.004 · Cited by 71
Magnetic Particle Imaging Guided Real-Time Percutaneous Transluminal Angioplasty in a Phantom Model
Herz, S., Vogel, P., Dietrich, P., Kampf, T., Rückert, M. A., Kickuth, R., Behr, V. C., & Bley, T. A. (2018) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-018-1955-7 · Cited by 68
Magnetic Particle Imaging for High Temporal Resolution Assessment of Aneurysm Hemodynamics
Sedlacik, J., Frölich, A. M., Spallek, J., Forkert, N. D., Faizy, T. D., Werner, F., Knopp, T., Krause, D., Fiehler, J., & Buhk, J. (2016) · PLoS ONE · doi:10.1371/journal.pone.0160097 · Cited by 67
Self-citationChristen, T., Ni, W., Qiu, D., Schmiedeskamp, H., Bammer, R., Moseley, M., & Zaharchuk, G. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24500 · Cited by 62
Kaul, M. G., Mummert, T., Jung, C., Salamon, J., Khandhar, A. P., Ferguson, R. M., Kemp, S. J., Ittrich, H., Krishnan, K. M., Adam, G., et al. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa5780 · Cited by 53
Self-citationJoint Reconstruction of Tracer Distribution and Background in Magnetic Particle Imaging
Straub, M., & Schulz, V. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2777878 · Cited by 49
Topography of acute stroke in a sample of 439 right brain damaged patients
Sperber, C., & Karnath, H. (2015) · NeuroImage Clinical · doi:10.1016/j.nicl.2015.11.012 · Cited by 48
Human PNS and SAR study in the frequency range from 24 to 162 kHz
Schmale, I., Gleich, B., Schmidt, J. D., Rahmer, J., Bontus, C., Eckart, R., David, B. R., Heinrich, M., Mende, O., Woywode, O., et al. (2013) · International Workshop on Magnetic Particle Imaging · doi:10.1109/iwmpi.2013.6528346 · Cited by 46
Self-citationKaul, M., Weber, O., Heinen, U., Reitmeier, A., Mummert, T., Jung, C., Raabe, N., Knopp, T., Ittrich, H., & Adam, G. (2015) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-0034-1399344 · Cited by 42 · cited 1×
“of about 1cm would be sucient. This allows the system to be designed with an reduced gradient strength of 0:2Tm 10 in y-direction which is about 10% of the gradient strength of preclinical systems [19]. As encoding scheme an eld-freepoint (FFP) conguration is used. Thus, in x- and z-direction the gradient provides onl…”
BackgroundSelf-citationMagnetic particle imaging: kinetics of the intravascular signal in vivo
Haegele, J., Lüdtke-Buzug, K., Schaecke, C., Graeser, M., Duschka, R. L., Panagiotopoulos, N., Buzug, T. M., VOGT, F. M., & Barkhausen, J. (2014) · International Journal of Nanomedicine · doi:10.2147/ijn.s49976 · Cited by 39
Self-citationReimer, P., Schuierer, G. R., Balzer, T., & Peters, P. E. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340507 · Cited by 39
Werner, F., Gdaniec, N., & Knopp, T. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa6177 · Cited by 36
Self-citationTwo dimensional magnetic particle spectrometry
Graeser, M., von Gladiss, A., Weber, M., & Buzug, T. M. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa5bcd · Cited by 28
Self-citation
Research works printed but not linked: 6
- Rahmer, J., Stehning, C. & Gleich, B. Remote magnetic actuation using a clinical scale system. PLoS One 13, e0193546 (2018). · DOI
- Southern, P. & Pankhurst, Q. Using the “dispersion-retention-formulation method” to estimate clinical and preclinical dosage limits for interstitial nanomedicines or agents. J. Magn. Magn. Mater. 473 (2018). https://doi.org/10.1016/j.jmmm.2018.10.019. · doi:10.1016/j.jmmm.2018.10.019
- Knopp, T. et al. MDF: magnetic particle imaging data format. Preprint at arXiv:1602.06072 (2016). · arXiv
- Lawaczeck, R. et al. Magnetic iron oxide particles coated with carboxydextran for parenteral administration and liver contrasting: pre-clinical profile of sh u555a. Acta Radiol. 38, 584–597 (1997).
- Knopp, T., Them, K., Kaul, M. & Gdaniec, N. Joint reconstruction of non-overlapping magnetic particle imaging focus-field data. Phys. Med. Biol. 60, L15 (2015). · DOI
- Moreira, M., Dias, P., Cordeiro, M., Santos, G. & Fernandes, J. M. International Conference on Image Analysis and Processing. 141–150 (Springer, Póvoa de Varzin, Portugal, 2010). · doi:10.1007/978-3-642-13775-4_15
Cited by
Magnetically Driven Micro and Nanorobots
Zhou, H., Mayorga-Martinez, C. C., Pané, S., Zhang, L., & Pumera, M. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01234 · Cited by 889
Magnetic nanoparticles in nanomedicine: a review of recent advances
Wu, K., Su, D., Liu, J., Saha, R., & Wang, J.-P. (2019) · Nanotechnology · doi:10.1088/1361-6528/ab4241 · Cited by 509
Medical Imaging of Microrobots: Toward In Vivo Applications
Aziz, A., Pane, S., Iacovacci, V., Koukourakis, N., Czarske, J., Menciassi, A., Medina-Sánchez, M., & Schmidt, O. G. (2020) · ACS Nano · doi:10.1021/acsnano.0c05530 · Cited by 287
Magnetic torque–driven living microrobots for increased tumor infiltration
Gwisai, T., Mirkhani, N., Christiansen, M. G., Nguyen, T. T., Ling, V., & Schuerle, S. (2022) · Science Robotics · doi:10.1126/scirobotics.abo0665 · Cited by 189
“Gradient fields used in MPI have proven challenging to scale up to humans, but recent efforts have demonstrated MPI in deep regions in human brains with moderate resolution (55).”
BackgroundMagnetic Nanostructures: Rational Design and Fabrication Strategies toward Diverse Applications
Wang, S., Xu, J., Li, W., Sun, S., Gao, S., & Hou, Y. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00370 · Cited by 129
Metadata
- Authors
- Graeser, M., Thieben, F., Szwargulski, P., Werner, F., Gdaniec, N., Boberg, M., Griese, F., Möddel, M., Ludewig, P., van de Ven, D., Weber, O. M., Woywode, O., Gleich, B., & Knopp, T.
- Venue
- Nature Communications
- Published
- 2019-04-26
- Volume
- 10
- Issue
- 1
- Pages
- 1936-1936
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2897138438
- Cited by
- 334
- References
- 41
- FWCI
- 11.36
- Type
- journal article
- Language
- en
- Open access
- gold
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.