Catheter-integrated soft multilayer electronic arrays for multiplexed sensing and actuation during cardiac surgery
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
The rigidity and relatively primitive modes of operation of catheters equipped with sensing or actuation elements impede their conformal contact with soft-tissue surfaces, limit the scope of their uses, lengthen surgical times and increase the need for advanced surgical skills. Here, we report materials, device designs and fabrication approaches for integrating advanced electronic functionality with catheters for minimally invasive forms of cardiac surgery. By using multiphysics modelling, plastic heart models and Langendorff animal and human hearts, we show that soft electronic arrays in multilayer configurations on endocardial balloon catheters can establish conformal contact with curved tissue surfaces, support high-density spatiotemporal mapping of temperature, pressure and electrophysiological parameters and allow for programmable electrical stimulation, radiofrequency ablation and irreversible electroporation. Integrating multimodal and multiplexing capabilities into minimally invasive surgical instruments may improve surgical performance and patient outcomes. Soft multilayer electronic arrays on endocardial balloon catheters allow for multiplexed high-density spatiotemporal sensing and actuation, as shown in perfused ex vivo hearts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Self-citationBiere, S. S., van Berge Henegouwen, M. I., Maas, K. W., Bonavina, L., Rosman, C., Garcia, J. R., Gisbertz, S. S., Klinkenbijl, J. H., Hollmann, M. W., de Lange, E. S., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60516-9 · Cited by 1,710
Gustafsson, S. E. (1991) · Review of Scientific Instruments · doi:10.1063/1.1142087 · Cited by 1,480
Skin-inspired highly stretchable and conformable matrix networks for multifunctional sensing
Hua, Q., Sun, J., Liu, H., Bao, R., Yu, R., Zhai, J., Pan, C., & Wang, Z. L. (2018) · Nature Communications · doi:10.1038/s41467-017-02685-9 · Cited by 1,413
Ferromagnetic soft continuum robots
Kim, Y., Parada, G. A., Liu, S., & Zhao, X. (2019) · Science Robotics · doi:10.1126/scirobotics.aax7329 · Cited by 1,312
Ultrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. C., Bonifas, A. P., Behnaz, A., Zhang, Y., Yu, K. J., Cheng, H., Shi, M., Bian, Z., Liu, Z., Kim, Y.-S., et al. (2013) · Nature Materials · doi:10.1038/nmat3755 · Cited by 1,229
Self-citationDynamics of Cell Generation and Turnover in the Human Heart
Bergmann, O., Zdunek, S., Felker, A., Salehpour, M., Alkass, K., Bernard, S., Sjostrom, S. L., Szewczykowska, M., Jackowska, T., dos Remedios, C., et al. (2015) · Cell · doi:10.1016/j.cell.2015.05.026 · Cited by 1,133
Xu, S., Yan, Z., Jang, K.-I., Huang, W., Fu, H., Kim, J., Wei, Z., Flavin, M., McCracken, J., Wang, R., et al. (2015) · Science · doi:10.1126/science.1260960 · Cited by 931
Self-citationBinodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care
Chung, H. U., Kim, B. H., Lee, J. Y., Lee, J., Xie, Z., Ibler, E. M., Lee, K., Banks, A., Jeong, J. Y., Kim, J., et al. (2019) · Science · doi:10.1126/science.aau0780 · Cited by 807
Self-citationTactile sensing for dexterous in-hand manipulation in robotics—A review
Yousef, H., Boukallel, M., & Althoefer, K. (2011) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.02.038 · Cited by 784
Kim, D.-H., Lu, N., Ghaffari, R., Kim, Y.-S., Lee, S. P., Xu, L., Wu, J., Kim, R.-H., Song, J., Liu, Z., et al. (2011) · Nature Materials · doi:10.1038/nmat2971 · Cited by 770
Self-citationYokoyama, K., Nakagawa, H., Shah, D. C., Lambert, H., Leo, G., Aeby, N., Ikeda, A., Pitha, J. V., Sharma, T., Lazzara, R., et al. (2008) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.108.803650 · Cited by 624
Self-assembled three dimensional network designs for soft electronics
Jang, K.-I., Li, K., Chung, H. U., Xu, S., Jung, H. N., Yang, Y., Kwak, J. W., Jung, H. H., Song, J., Yang, C., et al. (2017) · Nature Communications · doi:10.1038/ncomms15894 · Cited by 445
Self-citationOxley, T. J., Opie, N. L., John, S. E., Rind, G. S., Ronayne, S. M., Wheeler, T. L., Judy, J. W., McDonald, A. J., Dornom, A., Lovell, T. J. H., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3428 · Cited by 339
Stretchable surfaces with programmable 3D texture morphing for synthetic camouflaging skins
Pikul, J. H., Li, S., Bai, H., Hanlon, R. T., Cohen, I., & Shepherd, R. F. (2017) · Science · doi:10.1126/science.aan5627 · Cited by 310
Transcatheter Self‐Powered Ultrasensitive Endocardial Pressure Sensor
Liu, Z., Ma, Y., Ouyang, H., Shi, B., Li, N., Jiang, D., Xie, F., Qu, D., Zou, Y., Huang, Y., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201807560 · Cited by 308
Self-citationFang, H., Yu, K. J., Gloschat, C., Yang, Z., Song, E., Chiang, C.-H., Zhao, J., Won, S. M., Xu, S., Trumpis, M., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0038 · Cited by 278
Self-citationBasic Aspects of Radiofrequency Catheter Ablation
NATH, S., DiMARCO, J. P., & HAINES, D. E. (1994) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1994.tb01125.x · Cited by 253
Minimally Invasive and Regenerative Therapeutics
Ashammakhi, N., Ahadian, S., Darabi, M. A., El Tahchi, M., Lee, J., Suthiwanich, K., Sheikhi, A., Dokmeci, M. R., Oklu, R., & Khademhosseini, A. (2019) · Advanced Materials · doi:10.1002/adma.201804041 · Cited by 190
Percutaneous Cell Delivery into the Heart Using Hydrogels Polymerizing in Situ
Martens, T. P., Godier-Furnémont, A., Parks, J. J., Wan, L. Q., Koeckert, M. S., Eng, G. M., Hudson, B. I., Sherman, W., & Vunjak‐Novakovic, G. (2009) · Cell Transplantation · doi:10.3727/096368909788534915 · Cited by 165
Integrated optic electrooptic modulator electrode analysis
Ramer, O. G. (1982) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.1982.1071549 · Cited by 141
Role of Contact Force Sensing in Catheter Ablation of Cardiac Arrhythmias
Ariyarathna, N., Kumar, S., Thomas, S. P., Stevenson, W. G., & Michaud, G. F. (2018) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2018.03.014 · Cited by 133
Dukkipati, S. R., Neuzil, P., Skoda, J., Petru, J., d'Avila, A., Doshi, S. K., & Reddy, V. Y. (2010) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.933283 · Cited by 111
Flexible Thin-Film PVDF-TrFE Based Pressure Sensor for Smart Catheter Applications
Sharma, T., Aroom, K., Naik, S., Gill, B. S., & Zhang, J. X. J. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0708-z · Cited by 111
Catheter Ablation for Atrial Fibrillation
Wazni, O. M., Wilkoff, B. L., & Saliba, W. I. (2011) · New England Journal of Medicine · doi:10.1056/nejmct1109977 · Cited by 98
Krishnan, S. R., Ray, T. R., Ayer, A. B., Ma, Y., Gutruf, P., Lee, K., Lee, J. Y., Wei, C., Feng, X., Ng, B., et al. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aat8437 · Cited by 89
Self-citationState-of-the-art and emerging technologies for atrial fibrillation ablation
Dewire, J., & Calkins, H. G. (2010) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2009.232 · Cited by 73
Scanning Approaches of 2-D Resistive Sensor Arrays: A Review
Wu, J. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2641001 · Cited by 66
Minimally invasive paediatric cardiac surgery
BACHA, E. A., & Kalfa, D. M. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.168 · Cited by 65
Costa, P. F. R., Ribeiro, S., & Lanceros-Méndez, S. (2015) · Composites Science and Technology · doi:10.1016/j.compscitech.2015.01.006 · Cited by 64
Klinker, L. E., Lee, S. P., Work, J., Wright, J., Ma, Y., Ptaszek, L. M., Webb, R. C., Liu, C. Z. W., Sheth, N., MANSOUR, M. C., et al. (2015) · Extreme Mechanics Letters · doi:10.1016/j.eml.2015.02.005 · Cited by 61
Self-citationRHYTHM: An Open Source Imaging Toolkit for Cardiac Panoramic Optical Mapping
Gloschat, C., Aras, K., Gupta, S., Faye, N. R., Zhang, H., Syunyaev, R. A., Pryamonosov, R. A., Rogers, J. M., Kay, M. W., & Efimov, I. R. (2018) · Scientific Reports · doi:10.1038/s41598-018-21333-w · Cited by 52
Self-citationLee, S. P., Klinker, L. E., Ptaszek, L. M., Work, J., Liu, C. Z. W., Quivara, F., Webb, C., Dağdeviren, C., Wright, J. A., Ruskin, J. N., et al. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2401596 · Cited by 50
Self-citationRodenhauser, A., Good, W. W., Zenger, B., Tate, J. D., Aras, K., Burton, B. M., & MacLeod, R. (2018) · The Journal of Open Source Software · doi:10.21105/joss.00472 · Cited by 46
Self-citationA light-reflecting balloon catheter for atraumatic tissue defect repair
Roche, E. T., Fabozzo, A., Lee, Y., Polygerinos, P., Friehs, I., Schuster, L., Whyte, W., Berazaluce, A. M. C., Bueno, A., Lang, N., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa2406 · Cited by 42
Self-citation
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Self-citationSoft actuators for real-world applications
Li, M., Pal, A., Aghakhani, A., Pena-Francesch, A., & Sitti, M. (2021) · Nature Reviews Materials · doi:10.1038/s41578-021-00389-7 · Cited by 880
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
A three-dimensionally architected electronic skin mimicking human mechanosensation
Liu, Z., Hu, X., Bo, R., Yang, Y., Cheng, X., Pang, W., Liu, Q., Wang, Y., Wang, S., Xu, S., et al. (2024) · Science · doi:10.1126/science.adk5556 · Cited by 411
Progress of flexible strain sensors for physiological signal monitoring
Shen, Z., Liu, F., Huang, S., Wang, H., Yang, C., Hang, T., Tao, J., Xia, W., & Xie, X. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114298 · Cited by 250
Metadata
- Authors
- Han, M., Chen, L., Aras, K., Liang, C., Chen, X., Zhao, H., Li, K., Faye, N. R., Sun, B., Kim, J.-H., Bai, W., Yang, Q., Ma, Y., Lu, W., Song, E., Baek, J. M., Lee, Y., Liu, C., Model, J. B., Yang, G., Ghaffari, R., Huang, Y., Efimov, I. R., & Rogers, J. A.
- Venue
- Nature Biomedical Engineering
- Published
- 2020-09-07
- Volume
- 4
- Issue
- 10
- Pages
- 997-1009
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W3083738679
- Cited by
- 324
- References
- 35
- FWCI
- 11.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.