Nano-optic endoscope for high-resolution optical coherence tomography in vivo
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Acquisition of high-resolution images from within internal organs using endoscopic optical imaging has numerous clinical applications. However, difficulties associated with optical aberrations and the trade-off between transverse resolution and depth of focus significantly limit the scope of applications. Here, we integrate a metalens, with the ability to modify the phase of incident light at subwavelength level, into the design of an endoscopic optical coherence tomography catheter (termed nano-optic endoscope) to achieve near diffraction-limited imaging through negating non-chromatic aberrations. Remarkably, the tailored chromatic dispersion of the metalens in the context of spectral interferometry is utilized to maintain high-resolution imaging beyond the input field Rayleigh range, easing the trade-off between transverse resolution and depth of focus. We demonstrate endoscopic imaging in resected human lung specimens and in sheep airways in vivo. The combination of the superior resolution and higher imaging depth of focus of the nano-optic endoscope is likely to increase the clinical utility of endoscopic optical imaging. A metalens is integrated into the design of an endoscopic optical coherence tomography catheter to achieve near-diffraction-limited imaging free of non-chromatic aberrations, offering high-resolution imaging well beyond the Rayleigh range of the input field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Light Propagation with Phase Discontinuities: Generalized Laws of Reflection and Refraction
Yu, N., Genevet, P., Kats, M. A., Aieta, F., Tetienne, J.-P., Capasso, F., & Gaburro, Z. (2011) · Science · doi:10.1126/science.1210713 · Cited by 10,361
Self-citationMetalenses at visible wavelengths: Diffraction-limited focusing and subwavelength resolution imaging
Khorasaninejad, M., Chen, W. T., Devlin, R. C., Oh, J., Zhu, A. Y., & Capasso, F. (2016) · Science · doi:10.1126/science.aaf6644 · Cited by 3,411
Self-citationPerformance of fourier domain vs time domain optical coherence tomography
Leitgeb, R., Hitzenberger, C., & Fercher, A. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,854
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
Choma, M., Sarunic, M., Yang, C., & Izatt, J. (2003) · Optics Express · doi:10.1364/oe.11.002183 · Cited by 1,794
Balthasar Mueller, J. P., Rubin, N. A., Devlin, R. C., Groever, B., & Capasso, F. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.113901 · Cited by 1,771
Self-citationIn Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography
Tearney, G. J., Brezinski, M. E., Bouma, B. E., Boppart, S. A., Pitris, C., Southern, J. F., & Fujimoto, J. G. (1997) · Science · doi:10.1126/science.276.5321.2037 · Cited by 1,364
de Boer, J. F., Cense, B., Park, B. H., Pierce, M. C., Tearney, G. J., & Bouma, B. E. (2003) · Optics Letters · doi:10.1364/ol.28.002067 · Cited by 1,250
Characterization of Human Atherosclerosis by Optical Coherence Tomography
Yabushita, H., Bouma, B. E., Houser, S. L., Aretz, H. T., Jang, I.-K., Schlendorf, K. H., Kauffman, C. R., Shishkov, M., Kang, D.-H., Halpern, E. F., et al. (2002) · Circulation · doi:10.1161/01.cir.0000029927.92825.f6 · Cited by 1,246
Measurement of intraocular distances by backscattering spectral interferometry
Fercher, A. F., Hitzenberger, C. K., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,212
Metalenses: Versatile multifunctional photonic components
Khorasaninejad, M., & Capasso, F. (2017) · Science · doi:10.1126/science.aam8100 · Cited by 1,068
Self-citationvon Braunmühl, T. (2015) · Der Hautarzt · doi:10.1007/s00105-015-3607-z · Cited by 1,033
In vivo ultrahigh-resolution optical coherence tomography
Drexler, W., Morgner, U., Käertner, F. X., Pitris, C., Boppart, S. A., Li, X. D., Ippen, E. P., & Fujimoto, J. G. (1999) · Optics Letters · doi:10.1364/ol.24.001221 · Cited by 945
High-speed optical frequency-domain imaging
Yun, S., Tearney, G., de Boer, J., Iftimia, N., & Bouma, B. (2003) · Optics Express · doi:10.1364/oe.11.002953 · Cited by 865
Khorasaninejad, M., Shi, Z., Zhu, A. Y., Chen, W. T., Sanjeev, V., Zaidi, A., & Capasso, F. (2017) · Nano Letters · doi:10.1021/acs.nanolett.6b05137 · Cited by 661
Self-citationOptical coherence-domain reflectometry: a new optical evaluation technique
Youngquist, R. C., Carr, S., & Davies, D. E. N. (1987) · Optics Letters · doi:10.1364/ol.12.000158 · Cited by 597
Aluminum Plasmonic Multicolor Meta-Hologram
Huang, Y.-W., Chen, W. T., Tsai, W.-Y., Wu, P. C., Wang, C.-M., Sun, G., & Tsai, D. P. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b00184 · Cited by 595
Self-citationAssessment of Coronary Arterial Plaque by Optical Coherence Tomography
Kume, T., Akasaka, T., Kawamoto, T., Watanabe, N., Toyota, E., Neishi, Y., Sukmawan, R., Sadahira, Y., & Yoshida, K. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.11.035 · Cited by 573
Eye-length measurement by interferometry with partially coherent light
Fercher, A. F., Mengedoht, K., & Werner, W. (1988) · Optics Letters · doi:10.1364/ol.13.000186 · Cited by 516
Liu, L., Gardecki, J. A., Nadkarni, S. K., Toussaint, J. D., Yagi, Y., Bouma, B. E., & Tearney, G. J. (2011) · Nature Medicine · doi:10.1038/nm.2409 · Cited by 463
Achromatic Metasurface Lens at Telecommunication Wavelengths
Khorasaninejad, M., Aieta, F., Kanhaiya, P., Kats, M. A., Genevet, P., Rousso, D., & Capasso, F. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b01727 · Cited by 460
Self-citationComprehensive volumetric optical microscopy in vivo
Yun, S. H., Tearney, G. J., Vakoc, B. J., Shishkov, M., Oh, W. Y., Desjardins, A. E., Suter, M. J., Chan, R. C., Evans, J. A., Jang, I.-K., et al. (2006) · Nature Medicine · doi:10.1038/nm1450 · Cited by 438
Self-citationInterferometric synthetic aperture microscopy
Ralston, T. S., Marks, D. L., Scott Carney, P., & Boppart, S. A. (2007) · Nature Physics · doi:10.1038/nphys514 · Cited by 408
Silicon nanofin grating as a miniature chirality-distinguishing beam-splitter
Khorasaninejad, M., & Crozier, K. B. (2014) · Nature Communications · doi:10.1038/ncomms6386 · Cited by 317
Self-citationHigh resolution in vivo intra-arterial imaging with optical coherence tomography
Fujimoto, J. G., Boppart, S. A., Tearney, G. J., Bouma, B. E., Pitris, C., & Brezinski, M. E. (1999) · Heart · doi:10.1136/hrt.82.2.128 · Cited by 276
Super-Dispersive Off-Axis Meta-Lenses for Compact High Resolution Spectroscopy
Khorasaninejad, M., Chen, W. T., Oh, J., & Capasso, F. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b01097 · Cited by 230
Self-citationNadkarni, S. K., Pierce, M. C., Park, B. H., de Boer, J. F., Whittaker, P., Bouma, B. E., Bressner, J. E., Halpern, E., Houser, S. L., & Tearney, G. J. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.11.040 · Cited by 223
In vivo Optical Coherence Tomography Imaging of Preinvasive Bronchial Lesions
Lam, S., Standish, B., Baldwin, C., McWilliams, A., leRiche, J., Gazdar, A., Vitkin, A. I., Yang, V., Ikeda, N., & MacAulay, C. (2008) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-07-4418 · Cited by 197
Rollins, A. M., Ung-arunyawee, R., Chak, A., Wong, R. C. K., Kobayashi, K., Sivak, M. V., & Izatt, J. A. (1999) · Optics Letters · doi:10.1364/ol.24.001358 · Cited by 181
Visible-light optical coherence tomography: a review
Shu, X., Beckmann, L., & Zhang, H. F. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.12.121707 · Cited by 173
Broadband Multifunctional Efficient Meta-Gratings Based on Dielectric Waveguide Phase Shifters
Khorasaninejad, M., & Capasso, F. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b02524 · Cited by 137
Self-citationDiffractive catheter for ultrahigh-resolution spectral-domain volumetric OCT imaging
Xi, J., Zhang, A., Liu, Z., Liang, W., Lin, L. Y., Yu, S., & Li, X. D. (2014) · Optics Letters · doi:10.1364/ol.39.002016 · Cited by 67
Kim, J., Xing, J., Nam, H. S., Song, J. W., Kim, J. W., & Yoo, H. (2017) · Optics Letters · doi:10.1364/ol.42.000379 · Cited by 65
Hariri, L. P., Adams, D. C., Wain, J. C., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201707-1446le · Cited by 61
Self-citation
Cited by
Flat optics with dispersion-engineered metasurfaces
Chen, W. T., Zhu, A. Y., & Capasso, F. (2020) · Nature Reviews Materials · doi:10.1038/s41578-020-0203-3 · Cited by 802
Self-citationOptical meta-waveguides for integrated photonics and beyond
Meng, Y., Chen, Y., Lu, L., Ding, Y., Cusano, A., Fan, J. A., Hu, Q., Wang, K., Xie, Z., Liu, Z., et al. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00655-x · Cited by 464
Roadmap for Optical Metasurfaces
Kuznetsov, A. I., Brongersma, M. L., Yao, J., Chen, M. K., Levy, U., Tsai, D. P., Zheludev, N. I., Faraon, A., Arbabi, A., Yu, N., et al. (2024) · ACS Photonics · doi:10.1021/acsphotonics.3c00457 · Cited by 420
Liu, M., Zhu, W., Huo, P., Feng, L., Song, M., Zhang, C., Chen, L., Lezec, H. J., Lu, Y., Agrawal, A., et al. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00552-3 · Cited by 393
High-efficiency broadband achromatic metalens for near-IR biological imaging window
Wang, Y., Chen, Q., Yang, W., Ji, Z., Jin, L., Ma, X., Song, Q., Boltasseva, A., Han, J., Shalaev, V. M., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-25797-9 · Cited by 384
Metadata
- Authors
- Pahlevaninezhad, H., Khorasaninejad, M., Huang, Y.-W., Shi, Z., Hariri, L. P., Adams, D. C., Ding, V., Zhu, A., Qiu, C.-W., Capasso, F., & Suter, M. J.
- Venue
- Nature Photonics
- Published
- 2018-07-30
- Volume
- 12
- Issue
- 9
- Pages
- 540-547
- ISSN
- 1749-4885 (ISSN-L)
- 1749-4893
- OpenAlex
- W2883697371
- Cited by
- 412
- References
- 34
- FWCI
- 12.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.