Next-generation MRI scanner designed for ultra-high-resolution human brain imaging at 7 Tesla
Open accessThe DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Abstract
To increase granularity in human neuroimaging science, we designed and built a next-generation 7 Tesla magnetic resonance imaging scanner to reach ultra-high resolution by implementing several advances in hardware. To improve spatial encoding and increase the image signal-to-noise ratio, we developed a head-only asymmetric gradient coil (200 mT m−1, 900 T m−1 s−1) with an additional third layer of windings. We integrated a 128-channel receiver system with 64- and 96-channel receiver coil arrays to boost signal in the cerebral cortex while reducing g-factor noise to enable higher accelerations. A 16-channel transmit system reduced power deposition and improved image uniformity. The scanner routinely performs functional imaging studies at 0.35–0.45 mm isotropic spatial resolution to reveal cortical layer functional activity, achieves high angular resolution in diffusion imaging and reduces acquisition time for both functional and structural imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkinson, M., Beckmann, C. F., Behrens, T. E. J., Woolrich, M. W., & Smith, S. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.015 · Cited by 11,314
Distributed hierarchical processing in the primate cerebral cortex
Felleman, D. J., & Van Essen, D. C. (1991) · Cerebral Cortex · doi:10.1093/cercor/1.1.1 · Cited by 7,783 · cited 1×
“The respective achievable isotropic volumetric resolutions (voxel volume) are 0.09, 0.23 and 0.343 μl, corresponding to a 2.55-and 3.76-fold gain in volumetric resolution using the Impulse gradient coil.”
InfluentialSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 2×
“The respective achievable isotropic volumetric resolutions (voxel volume) are 0.09, 0.23 and 0.343 μl, corresponding to a 2.55-and 3.76-fold gain in volumetric resolution using the Impulse gradient coil.”
InfluentialMeasuring the thickness of the human cerebral cortex from magnetic resonance images
Fischl, B., & Dale, A. M. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.200033797 · Cited by 5,818 · cited 1×
“17,18) and with cortical columnar features being 0.6–1.0 mm, higher resolution is needed to adequately sample cortical layers and columns and to minimize partial volume averaging of surrounding white matter and cerebrospinal fluid (CSF).”
InfluentialA multi-modal parcellation of human cerebral cortex
Glasser, M. F., Coalson, T. S., Robinson, E. C., Hacker, C. D., Harwell, J., Yacoub, E., Ugurbil, K., Andersson, J., Beckmann, C. F., Jenkinson, M., et al. (2016) · Nature · doi:10.1038/nature18933 · Cited by 5,111 · cited 1×
“17,18) and with cortical columnar features being 0.6–1.0 mm, higher resolution is needed to adequately sample cortical layers and columns and to minimize partial volume averaging of surrounding white matter and cerebrospinal fluid (CSF).”
InfluentialSelf-citationPreface: Cerebral Cortex Has Come of Age
Goldman-Rakic, P. S., & Rakic, P. (1991) · Cerebral Cortex · doi:10.1093/cercor/1.1.1-a · Cited by 3,393
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322 · cited 1×
“Following the method of Kellmann et al. 76 , SNR maps used the noise-covariance-weighted optimal coil combination of the individual channel images, where the weights use coil sensitivity maps and noise-covariance information 76,77 .”
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142 · cited 1×
“The respective achievable isotropic volumetric resolutions (voxel volume) are 0.09, 0.23 and 0.343 μl, corresponding to a 2.55-and 3.76-fold gain in volumetric resolution using the Impulse gradient coil.”
InfluentialESPIRiT—an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA
Uecker, M., Lai, P., Murphy, M. J., Virtue, P., Elad, M., Pauly, J. M., Vasanawala, S. S., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24751 · Cited by 1,392 · cited 1×
“Overlapping receive coil conductors that are too close created spikes due to vibrations at high gradient strengths.”
Setsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23097 · Cited by 1,285 · cited 1×
“Whole-brain EPI was collected using a 2D SMS sequence GRAPPA 4, multiband 3, FOV/2 controlled aliasing 83”
Self-citationThe Human Connectome Project's neuroimaging approach
Glasser, M. F., Smith, S. M., Marcus, D. S., Andersson, J. L. R., Auerbach, E. J., Behrens, T. E. J., Coalson, T. S., Harms, M. P., Jenkinson, M., Moeller, S., et al. (2016) · Nature Neuroscience · doi:10.1038/nn.4361 · Cited by 1,090 · cited 1×
“The resolution gains in MRI on the NexGen 7 T scanner using EPI with whole-brain coverage are volumetrically up to roughly 20 times higher compared to common 7 T fMRI resolutions 0.175 versus 4.1 μl for 0.56 versus 1.6 mm isotropic voxels 49 ).”
InfluentialSelf-citation7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890 · cited 1×
“In aggregate, the higher signal 26 and greater blood oxygenation level-dependent (BOLD) contrast of 7 T coupled with higher resolution, SNR and faster signal acquisition of the NexGen 7 T scanner enable improved diffusion imaging and mesoscale imaging in vivo.”
Differentiating BOLD and non-BOLD signals in fMRI time series using multi-echo EPI
Kundu, P., Inati, S. J., Evans, J. W., Luh, W.-M., & Bandettini, P. A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.028 · Cited by 615 · cited 1×
“Multiecho EPI is of value to fMRI studies, given that it can be combined across TEs to maximize tSNR and reduce signal dropout 39,40 , and can also be used to differentiate BOLD signal from noise components in fMRI time series using independent component analysis 41 .”
High-field fMRI unveils orientation columns in humans
Yacoub, E., Harel, N., & Uğurbil, K. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0804110105 · Cited by 566
Self-citationPushing the limits of in vivo diffusion MRI for the Human Connectome Project
Setsompop, K., Kimmlingen, R., Eberlein, E., Witzel, T., Cohen-Adad, J., McNab, J. A., Keil, B., Tisdall, M. D., Hoecht, P., Dietz, P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.078 · Cited by 545
Self-citationImage reconstruction in SNR units: A general method for SNR measurement†
Kellman, P., & McVeigh, E. R. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20713 · Cited by 535 · cited 1×
“Following the method of Kellmann et al. 76 , SNR maps used the noise-covariance-weighted optimal coil combination of the individual channel images, where the weights use coil sensitivity maps and noise-covariance information 76,77 .”
Functional magnetic resonance imaging based on changes in vascular space occupancy
Lu, H., Golay, X., Pekar, J. J., & van Zijl, P. C. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10519 · Cited by 463 · cited 12×
“VASO EPI 0.64.”
InfluentialThe Geometric Structure of the Brain Fiber Pathways
Wedeen, V. J., Rosene, D. L., Wang, R., Dai, G., Mortazavi, F., Hagmann, P., Kaas, J. H., & Tseng, W.-Y. I. (2012) · Science · doi:10.1126/science.1215280 · Cited by 445 · cited 1×
“The scanner routinely performs functional imaging studies at 0.35–0.45 mm isotropic spatial resolution to reveal cortical layer functional activity, achieves high angular resolution in diffusion imaging and reduces acquisition time for both functional and structural imaging.”
InfluentialPoser, B. A., Versluis, M. J., Hoogduin, J. M., & Norris, D. G. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20900 · Cited by 439 · cited 2×
“Data were collected using the MultiBand (SMS) EPI 2D BOLD sequence, distributed via a Consumer-to-Producer agreement from the Center for Magnetic Resonance Research, University of Minnesota, ported onto the MAGNETOM Terra Impulse edition NexGen 7 T scanner (VE12U-AP02).”
InfluentialLaminar analysis of 7T BOLD using an imposed spatial activation pattern in human V1
Polimeni, J. R., Fischl, B., Greve, D. N., & Wald, L. L. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.005 · Cited by 431
Self-citationGradient coil design: A review of methods
Turner, R. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90209-v · Cited by 418 · cited 1×
“The resolution gains in MRI on the NexGen 7 T scanner using EPI with whole-brain coverage are volumetrically up to roughly 20 times higher compared to common 7 T fMRI resolutions 0.175 versus 4.1 μl for 0.56 versus 1.6 mm isotropic voxels 49 ).”
InfluentialSelective Activation of the Deep Layers of the Human Primary Visual Cortex by Top-Down Feedback
Kok, P., Bains, L. J., van Mourik, T., Norris, D. G., & de Lange, F. P. (2016) · Current Biology · doi:10.1016/j.cub.2015.12.038 · Cited by 397
Enhancement of BOLD-contrast sensitivity by single-shot multi-echo functional MR imaging
Posse, S., Wiese, S., Gembris, D., Mathiak, K., Kessler, C., Grosse-Ruyken, M.-L., Elghahwagi, B., Richards, T., Dager, S. R., & Kiselev, V. G. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199907)42:1<87::aid-mrm13>3.0.co;2-o · Cited by 388 · cited 1×
“Physiological modeling 28 used to optimize the wiring pattern of the three-layer Article https://doi.org/10.1038/s41592-023-02068-7 from 1.21 ms using the body gradient coil for a corresponding reduction of minimum TE of 17 ms reduced from 34 ms.”
InfluentialHuman Ocular Dominance Columns as Revealed by High-Field Functional Magnetic Resonance Imaging
Cheng, K., Waggoner, R. A., & Tanaka, K. (2001) · Neuron · doi:10.1016/s0896-6273(01)00477-9 · Cited by 383
The Human Connectome Project and beyond: Initial applications of 300mT/m gradients
McNab, J. A., Edlow, B. L., Witzel, T., Huang, S. Y., Bhat, H., Heberlein, K., Feiweier, T., Liu, K., Keil, B., Cohen-Adad, J., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.074 · Cited by 359
Self-citationHuber, L., Handwerker, D. A., Jangraw, D. C., Chen, G., Hall, A., Stüber, C., Gonzalez-Castillo, J., Ivanov, D., Marrett, S., Guidi, M., et al. (2017) · Neuron · doi:10.1016/j.neuron.2017.11.005 · Cited by 341 · cited 1×
“…using vascular space occupancy (VASO) 43 pulse sequences, which localizes activation to specific cortical layers more precisely than BOLD by minimizing sensitivity to cortical draining veins, has shown depth-dependent activations in motor, somatosensory and frontal regions of cortex 13,14,16 (Fig.”
Self-citationMulti-echo fMRI: A review of applications in fMRI denoising and analysis of BOLD signals
Kundu, P., Voon, V., Balchandani, P., Lombardo, M. V., Poser, B. A., & Bandettini, P. A. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.03.033 · Cited by 321 · cited 2×
“Images collected at different TEs can be optimally combined to maximize tSNR and reduce signal dropout across different brain regions 40,42 .”
Influential9.4T human MRI: Preliminary results
Vaughan, T., DelaBarre, L., Snyder, C., Tian, J., Akgun, C., Shrivastava, D., Liu, W., Olson, C., Adriany, G., Strupp, J., et al. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21073 · Cited by 317 · cited 1×
“Higher magnetic field scanners (9.4, 10 .5 and 11.7 T and in the future possibly 14 T) 55–58 raise SNR in human brain imaging; however, fMRI and structural neuroscience studies are more difficult to conduct at these ultra-high field strengths due to the complexity of imaging with greater RF heating…”
InfluentialYacoub, E., Shmuel, A., Logothetis, N., & Uğurbil, K. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.05.020 · Cited by 308
Self-citationSpin‐echo fMRI in humans using high spatial resolutions and high magnetic fields
Yacoub, E., Duong, T. Q., Van De Moortele, P., Lindquist, M., Adriany, G., Kim, S., Uğurbil, K., & Hu, X. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10433 · Cited by 308 · cited 1×
“47).”
Self-citationRapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readout
Chung, S., Kim, D., Breton, E., & Axel, L. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22423 · Cited by 304 · cited 1×
“The excitation flip angle maps were acquired using a preconditioning saturation pulse with a turbo-fast low-angle shot readout 78 (TR, TE and flip angle of 5 s, 2.02 ms and 90°; slice of 1.5 mm; matrix of 256 × 88; FOV = 256 × 128 mm 2 ; readout bandwidth of 335 Hz per pixel and turbo factor of…”
InfluentialOcular Dominance in Human V1 Demonstrated by Functional Magnetic Resonance Imaging
Menon, R. S., Ogawa, S., Strupp, J. P., & Uǧurbil, K. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.77.5.2780 · Cited by 293
Three dimensional echo-planar imaging at 7 Tesla
Poser, B. A., Koopmans, P. J., Witzel, T., Wald, L. L., & Barth, M. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.01.108 · Cited by 284 · cited 3×
“Whole-brain VASO data were acquired using a segmented IR 3D EPI sequence 33,34 using a 4 × 2 shot-selective CAIPI trajectory 84 with a phase encode CAIPI shift of two.”
Self-citation96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluation
Wiggins, G. C., Polimeni, J. R., Potthast, A., Schmitt, M., Alagappan, V., & Wald, L. L. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22028 · Cited by 274 · cited 2×
“Over the years, improvements to major MRI scanner system components (for example, magnetic field gradient coils 22–24 and radio-frequency (RF) receiver array coils 25 ) have led to higher signal-to-noise ratio (SNR) and higher resolution imaging or faster image acquisition (acceleration).”
Self-citationHalving MR imaging time by conjugation: demonstration at 3.5 kG.
Feinberg, D. A., Hale, J. D., Watts, J. C., Kaufman, L., & Mark, A. (1986) · Radiology · doi:10.1148/radiology.161.2.3763926 · Cited by 259 · cited 4×
“Estimates were compared for two different GRAPPA accelerations (three and four), with a constant partial Fourier factor (PF) of 0.75.”
InfluentialSelf-citationInner volume MR imaging: technical concepts and their application.
Feinberg, D. A., Hoenninger, J. C., Crooks, L. E., Kaufman, L., Watts, J. C., & Arakawa, M. (1985) · Radiology · doi:10.1148/radiology.156.3.4023236 · Cited by 230
Self-citationLayer-specific BOLD activation in human V1
Koopmans, P. J., Barth, M., & Norris, D. G. (2010) · Human Brain Mapping · doi:10.1002/hbm.20936 · Cited by 220
High resolution whole brain diffusion imaging at 7 T for the Human Connectome Project
Vu, A. T., Auerbach, E., Lenglet, C., Moeller, S., Sotiropoulos, S. N., Jbabdi, S., Andersson, J., Yacoub, E., & Ugurbil, K. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.004 · Cited by 218
Self-citationLayer-specific fMRI reflects different neuronal computations at different depths in human V1
Olman, C. A., Harel, N., Feinberg, D. A., He, S., Zhang, P., Ugurbil, K., & Yacoub, E. (2012) · PLoS ONE · doi:10.1371/journal.pone.0032536 · Cited by 194
Layer-dependent activity in human prefrontal cortex during working memory
Finn, E. S., Huber, L., Jangraw, D. C., Molfese, P. J., & Bandettini, P. A. (2019) · Nature Neuroscience · doi:10.1038/s41593-019-0487-z · Cited by 192 · cited 1×
“…using vascular space occupancy (VASO) 43 pulse sequences, which localizes activation to specific cortical layers more precisely than BOLD by minimizing sensitivity to cortical draining veins, has shown depth-dependent activations in motor, somatosensory and frontal regions of cortex 13,14,16 (Fig.”
Self-citationMapping the Organization of Axis of Motion Selective Features in Human Area MT Using High-Field fMRI
Zimmermann, J., Goebel, R., De Martino, F., van de Moortele, P.-F., Feinberg, D., Adriany, G., Chaimow, D., Shmuel, A., Uğurbil, K., & Yacoub, E. (2011) · PLoS ONE · doi:10.1371/journal.pone.0028716 · Cited by 188
Self-citationHuang, S. Y., Witzel, T., Keil, B., Scholz, A., Davids, M., Dietz, P., Rummert, E., Ramb, R., Kirsch, J. E., Yendiki, A., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118530 · Cited by 181 · cited 10×
“The timing parameters for a bipolar gradient waveform achieving this ES were calculated, and the maximum gradient that could be used within PNS limits was identified, corresponding to a Gmax of 98 mT m −1 and an SR 213 T m −1 s −1 .”
InfluentialSelf-citationCortical lamina-dependent blood volume changes in human brain at 7 T
Huber, L., Goense, J., Kennerley, A. J., Trampel, R., Guidi, M., Reimer, E., Ivanov, D., Neef, N., Gauthier, C. J., Turner, R., et al. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.11.046 · Cited by 169 · cited 1×
“…using vascular space occupancy (VASO) 43 pulse sequences, which localizes activation to specific cortical layers more precisely than BOLD by minimizing sensitivity to cortical draining veins, has shown depth-dependent activations in motor, somatosensory and frontal regions of cortex 13,14,16 (Fig.”
Self-citationLowering the thermal noise barrier in functional brain mapping with magnetic resonance imaging
Vizioli, L., Moeller, S., Dowdle, L., Akçakaya, M., De Martino, F., Yacoub, E., & Uğurbil, K. (2021) · Nature Communications · doi:10.1038/s41467-021-25431-8 · Cited by 165 · cited 2×
“To maintain SNR for functional imaging at such high resolutions, NORDIC denoising was applied 59 .”
Self-citationMeasurement of the point spread function in MRI using constant time imaging
Robson, M. D., Gore, J. C., & Constable, R. T. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380509 · Cited by 161 · cited 1×
“The dependence of PSF on gradient coil performance was defined and simulated as in previous work 32,81 as the anisotropic spread of information in the image from an idealized point source.”
Foo, T., Tan, E. T., Vermilyea, M. E., Hua, Y., Fiveland, E. W., Piel, J. E., Park, K., Ricci, J., Thompson, P. S., Graziani, D., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28087 · Cited by 149
Polimeni, J. R., Bhat, H., Witzel, T., Benner, T., Feiweier, T., Inati, S., Renvall, V., Heberlein, K., & Wald, L. L. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25628 · Cited by 141 · cited 1×
“The diffusion EPI sequence used a fast low-angle excitation echo-planar technique 86 reference scan for improved robustness to motion 46 .”
Self-citationLayer-dependent functional connectivity methods
Huber, L., Finn, E. S., Chai, Y., Goebel, R., Stirnberg, R., Stöcker, T., Marrett, S., Uludag, K., Kim, S.-G., Han, S., et al. (2021) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2020.101835 · Cited by 135 · cited 2×
“The respective achievable isotropic volumetric resolutions (voxel volume) are 0.09, 0.23 and 0.343 μl, corresponding to a 2.55-and 3.76-fold gain in volumetric resolution using the Impulse gradient coil.”
InfluentialSelf-citationHuber, L., Ivanov, D., Handwerker, D. A., Marrett, S., Guidi, M., Uludağ, K., Bandettini, P. A., & Poser, B. A. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2016.11.039 · Cited by 122 · cited 1×
“For very high resolutions, three-dimensional (3D) EPI sequences 33–36 have demonstrated higher SNR 37 and improved slice profiles 33 whereas thin slices are more difficult to define with two-dimensional (2D) selective excitation.”
Self-citationA high‐performance gradient insert for rapid and short‐T 2 imaging at full duty cycle
Weiger, M., Overweg, J., Rösler, M. B., Froidevaux, R., Hennel, F., Wilm, B. J., Penn, A., Sturzenegger, U., Schuth, W., Mathlener, M., et al. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26954 · Cited by 105
Stirnberg, R., & Stöcker, T. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28486 · Cited by 96
Self-citationFirst in‐vivo human imaging at 10.5T: Imaging the body at 447 MHz
He, X., Ertürk, M. A., Grant, A., Wu, X., Lagore, R., DelaBarre, L. J., Eryaman, Y., Adriany, G., Auerbach, E. J., de Moortele, P. V., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28131 · Cited by 94
Magnetic field strength dependent SNR gain at the center of a spherical phantom and up to 11. 7T
Ster, C. L., Grant, A., de Moortele, P. V., Monreal‐Madrigal, A., Adriany, G., Vignaud, A., Mauconduit, F., Rabrait‐Lerman, C., Poser, B. A., Uǧurbil, K., et al. (2022) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29391 · Cited by 89 · cited 1×
“Higher magnetic field scanners (9.4, 10 .5 and 11.7 T and in the future possibly 14 T) 55–58 raise SNR in human brain imaging; however, fMRI and structural neuroscience studies are more difficult to conduct at these ultra-high field strengths due to the complexity of imaging with greater RF heating…”
InfluentialDavids, M., Guérin, B., Endt, A. V., Schad, L. R., & Wald, L. L. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27382 · Cited by 72 · cited 1×
“While the basic wire-pattern optimization was achieved with boundary element stream function methods 63 , the design process additionally used combined electromagnetic and neu-rodynamic modeling 28 in a detailed body model with a nerve atlas 64,65 .”
Self-citationDavids, M., Guérin, B., Malzacher, M., Schad, L. R., & Wald, L. L. (2017) · Scientific Reports · doi:10.1038/s41598-017-05493-9 · Cited by 70 · cited 1×
“While the basic wire-pattern optimization was achieved with boundary element stream function methods 63 , the design process additionally used combined electromagnetic and neu-rodynamic modeling 28 in a detailed body model with a nerve atlas 64,65 .”
Self-citationHigh‐resolution whole‐brain diffusion MRI at 7T using radiofrequency parallel transmission
Wu, X., Auerbach, E. J., Vu, A. T., Moeller, S., Lenglet, C., Schmitter, S., de Moortele, P. V., Yacoub, E. S., & Uǧurbil, K. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27189 · Cited by 67 · cited 1×
“The 16-ch transmit system also enables B1 shim-ming to yield a more uniform transmit RF field, allowing sequences that require this uniformity to operate optimally 69 .”
Self-citationCao, X., Liao, C., Iyer, S., Wang, Z., Zhou, Z., Dai, E., Liberman, G., Dong, Z., Gong, T., He, H., et al. (2022) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29194 · Cited by 52 · cited 2×
“…TR and TE = 13 and 5.47 ms, FOV = 200 × 158.1 × 98.4 mm 3 , matrix size of 392 × 496, four slabs, 72 slices per slab, FA = 17, phase and slice partial Fourier of 7 and 8, GRAPPA 3, 70% tilted optimized nonsaturating excitation ramp 88 , readout bandwidth of 120 Hz per pixel, TA = 10 min and 19 s.”
InfluentialSelf-citationTan, E. T., Hua, Y., Fiveland, E. W., Vermilyea, M. E., Piel, J. E., Park, K. J., Ho, V. B., & Foo, T. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27909 · Cited by 52
Feinberg, D. A., Vu, A. T., & Beckett, A. J. S. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.02.020 · Cited by 49 · cited 14×
“The volumetric resolution gains for zoomed targeted fMRI imaging are on the order of ten times higher (0.059 μl versus 0.512 μl for 0.35 mm versus 0.8 mm isotropic voxels) with the actual gains higher due to PSF differences.”
InfluentialSelf-citationTao, S., Weavers, P. T., Trzasko, J. D., Shu, Y., Huston, J., Lee, S., Frigo, L. M., & Bernstein, M. A. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26315 · Cited by 46 · cited 1×
“…in hardware integration arose during testing that had to be solved: (1) The acquisition computer had to be modified to handle the larger data size acquired with the 128-ch receiver system and larger matrix sizes used for high-resolution imaging, including increasing the disk space for…”
Optimization of MRI Gradient Coils With Explicit Peripheral Nerve Stimulation Constraints
Davids, M., Guérin, B., Klein, V., & Wald, L. L. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3023329 · Cited by 45 · cited 15×
“Although the TE can be shortened by partial Fourier 50 , in-plane segmentation and higher parallel imaging acceleration 51,52 , these techniques typically involve trade-offs between SNR and PSF 32 (Extended Data Fig.”
InfluentialSelf-citationCortical fibers orientation mapping using in-vivo whole brain 7 T diffusion MRI
Gülban, Ö. F., Martino, F. D., Vu, A. T., Yacoub, E. S., Uǧurbil, K., & Lenglet, C. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.05.010 · Cited by 40
Self-citationVolumetric imaging with homogenised excitation and static field at 9.4 T
Tse, D. H. Y., Wiggins, C. J., Ivanov, D., Brenner, D., Hoffmann, J., Mirkes, C., Shajan, G., Scheffler, K., Uludaǧ, K., & Poser, B. A. (2016) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-016-0543-6 · Cited by 36
Hendriks, A. D., D’Agata, F., Raimondo, L., Schakel, T., Geerts, L., Luijten, P. R., Klomp, D. W. J., & Petridou, N. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4281 · Cited by 33 · cited 1×
“Whole-brain VASO data were acquired using a segmented IR 3D EPI sequence 33,34 using a 4 × 2 shot-selective CAIPI trajectory 84 with a phase encode CAIPI shift of two.”
Exploring structure and function of sensory cortex with 7 T MRI
Schluppeck, D., Sánchez-Panchuelo, R.-M., & Francis, S. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.081 · Cited by 33
Peripheral nerve stimulation informed design of a high‐performance asymmetric head gradient coil
Davids, M., Dietz, P., Ruyters, G., Rösler, M. B., Klein, V., Beckett, A. J. S., Vu, A. T., Guérin, B., Feinberg, D. A., & Wald, L. L. (2023) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29668 · Cited by 29 · cited 17×
“By contrast, previous 7 T head-only gradient coils use two winding layers and are limited by PNS to an SR of 400–500 T m −1 s −1 (ref.”
InfluentialSelf-citationPark, S., Torrisi, S., Townsend, J. D., Beckett, A. J. S., & Feinberg, D. A. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28589 · Cited by 21
Self-citation
Cited by
Engineering clinical translation of OGSE diffusion MRI
Zhu, A., Michael, E. S., Li, H., Sprenger, T., Hua, Y., Lee, S., Yeo, D. T. B., McNab, J. A., Hennel, F., Fieremans, E., et al. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30510 · Cited by 13
Metadata
- Authors
- Feinberg, D. A., Beckett, A. J. S., Vu, A. T., Stockmann, J., Huber, L., Ma, S., Ahn, S., Setsompop, K., Cao, X., Park, S., Liu, C., Wald, L. L., Polimeni, J. R., Mareyam, A., Gruber, B., Stirnberg, R., Liao, C., Yacoub, E., Davids, M., Bell, P., Rummert, E., Koehler, M., Potthast, A., Gonzalez-Insua, I., Stocker, S., Gunamony, S., & Dietz, P.
- Venue
- Nature Methods
- Published
- 2023-11-27
- Volume
- 20
- Issue
- 12
- Pages
- 2048-2057
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- OpenAlex
- W4389045706
- Cited by
- 196
- References
- 67
- FWCI
- 28.93
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).