New insights into the origin of remote PPG signals in visible light and infrared
Open accessThe DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
Remote photoplethysmography (PPG) is an optical measurement technique with established applications in vital signs monitoring. Recently, the consensual understanding of blood volume variations (BVVs) as the origin of PPG signals was challenged, raising validity concerns about the remote SpO 2 methodology. Recognizing the imperative for new opto-physiological evidence, this investigation supports the volumetric hypothesis with living skin experiments and Monte Carlo simulations of remote PPG-amplitude in visible light (VIS) and infrared (IR). Multilayered models of the skin were developed to simulate the separate contributions from skin layers containing pulsatile arterioles to the PPG signal in the 450–1000 nm range. The simulated spectra were qualitatively compared with observations of the resting and compressed finger pad, and complemented with videocapillaroscopy. Our results indicate that remote PPG systems indeed probe arterial blood. Green wavelengths probe dermal arterioles while red-IR wavelengths also reach subcutaneous BVVs. Owing to stable penetration depths, the red-IR diagnostic window promotes the invariance of SpO 2 measurements to skin non-homogeneities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008 · cited 2×
“Glaring examples are the absorption and scattering parameters, which are mostly determined in ex vivo tissue samples and may differ by an order of magnitude 36,37 .”
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456 · cited 1×
“The skin was modeled as multilayered media with optical properties that translate its anatomophysiol-ogy 19 .”
Optical properties of the clearest natural waters (200–800 nm)
Smith, R. C., & Baker, K. S. (1981) · Applied Optics · doi:10.1364/ao.20.000177 · Cited by 1,756 · cited 1×
“The epidermal absorption coefficient, μ a , EPI , was estimated as a combination of background tissue, μ a , base , EPI , and water: ) a EPI w a water w a base EPI , , , , μ a , water was determined from Palmer 52 and Smith 53 .”
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,719 · cited 2×
“Processing pipeline: (1, 2) Remote-PPG signals acquired at the finger pad are low-pass-filtered and AC/DC-normalized; (3, 4) The AC/DC streams are ensemble-averaged (EA) (template size, 31 samples per cardiac cycle), including (e) multiple of the pulse-rate frequency and (f,g) the fundamental only.”
Robust pulse rate from chrominance-based rPPG
de Haan, G., & Jeanne, V. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2266196 · Cited by 1,378 · cited 1×
“Remote PPG allows that the pulse-rate is extracted, preferentially, at green wavelengths, though a quest for motion robustness deems necessary that multiple wavelength bands (color-channels) are combined 7 .”
OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
BASHKATOV, A. N., GENINA, E. A., & TUCHIN, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 761 · cited 1×
“Glaring examples are the absorption and scattering parameters, which are mostly determined in ex vivo tissue samples and may differ by an order of magnitude 36,37 .”
Optical properties of water in the near infrared*
Palmer, K. F., & Williams, D. (1974) · Journal of the Optical Society of America · doi:10.1364/josa.64.001107 · Cited by 709 · cited 1×
“The epidermal absorption coefficient, μ a , EPI , was estimated as a combination of background tissue, μ a , base , EPI , and water: ) a EPI w a water w a base EPI , , , , μ a , water was determined from Palmer 52 and Smith 53 .”
Simpson, C. R., Kohl, M., Essenpreis, M., & Cope, M. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/9/003 · Cited by 651
Salomatina, E. V., Jiang, B., Novak, J., & Yaroslavsky, A. N. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2398928 · Cited by 599 · cited 1×
“3 was taken from Salomatina et al .”
Cited by
Current progress of photoplethysmography and SPO2 for health monitoring
Tamura, T. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00097-w · Cited by 247
The 2023 wearable photoplethysmography roadmap
Charlton, P. H., Allen, J., Bailón, R., Baker, S., Behar, J. A., Chen, F., Clifford, G. D., Clifton, D. A., Davies, H. J., Ding, C., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acead2 · Cited by 187
Kaisti, M., Panula, T., Leppänen, J., Punkkinen, R., Jafari Tadi, M., Vasankari, T., Jaakkola, S., Kiviniemi, T., Airaksinen, J., Kostiainen, P., et al. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0117-x · Cited by 164
Photoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
Chatterjee, S., & Kyriacou, P. A. (2019) · Sensors · doi:10.3390/s19040789 · Cited by 86
“This consideration manifests the physiological hypothesis that the systolic increase in blood volume in the arterioles increases the transmural pressure, resulting in a compression in the elastic fibres in the dermal connective tissue and the overall density of the capillaries present in the dermal sublayers [21].”
BackgroundAjmal, Boonya-Ananta, T., Rodriguez, A. J., Du Le, V. N., & Ramella-Roman, J. C. (2021) · Biomedical Optics Express · doi:10.1364/boe.439893 · Cited by 79
Moço, A., & Verkruysse, W. (2021) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00449-y · Cited by 55
Vahlsing, T., Delbeck, S., Leonhardt, S., & Heise, H. M. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818798347 · Cited by 28
“However, there is also evidence that the PPG waveforms are also influenced from the dermal capillary density due to pressure variations from the larger blood vessels.(27,28) Lower frequency components are usually superimposed, which can be attributed to respiration, vasomotion, sympathetic nervous system activity, and…”
BackgroundMethod
Metadata
- Authors
- Moço, A. V., Stuijk, S., & de Haan, G.
- Venue
- Scientific Reports
- Published
- 2018-05-31
- Volume
- 8
- Issue
- 1
- Pages
- 8501-8501
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2805165045
- Cited by
- 168
- References
- 50
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.