Stretchable and suturable fibre sensors for wireless monitoring of connective tissue strain
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Implantable sensors can be used to monitor biomechanical strain continuously. However, three key challenges need to be addressed before they can be of use in clinical practice: the structural mismatch between the sensors and tissue or organs should be eliminated; a practical suturing attachment process should be developed; and the sensors should be equipped with wireless readout. Here, we report a wireless and suturable fibre strain-sensing system created by combining a capacitive fibre strain sensor with an inductive coil for wireless readout. The sensor is composed of two stretchable conductive fibres organized in a double helical structure with an empty core, and has a sensitivity of around 12. Mathematical analysis and simulation of the sensor can effectively predict its capacitive response and can be used to modulate performance according to the intended application. To illustrate the capabilities of the system, we use it to perform strain measurements on the Achilles tendon and knee ligament in an ex vivo and in vivo porcine leg. A capacitive, fibre-like stretchable strain sensor, formed of two conductors in a double helical structure, can be combined with an inductive coil to create a wireless strain-sensing system for biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Nanomaterials[177,178] and liquid metals[179] can be used as electrodes owing to their stable conductivity under tensile strain.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [179]
In the citing paper
“In addition to monitoring external strain on the human skin, recently in vivo strain sensing has been investigated to monitor inner tissue, e.g. tendons and muscle recovery, by continuously providing real-time and long-term information for rehabilitation surveillance.[179,204]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [179]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Conductive Fiber‐Based Ultrasensitive Textile Pressure Sensor for Wearable Electronics
Lee, J., Kwon, H., Seo, J., Shin, S., Koo, J. H., Pang, C., Son, S., Kim, J. H., Jang, Y. H., Kim, D. E., et al. (2015) · Advanced Materials · doi:10.1002/adma.201500009 · Cited by 1,152
Self-citationConstitutive modeling of the large strain time-dependent behavior of elastomers
BERGSTROM, J. (1998) · Journal of the Mechanics and Physics of Solids · doi:10.1016/s0022-5096(97)00075-6 · Cited by 1,147
Bioresorbable silicon electronic sensors for the brain
Kang, S.-K., Murphy, R. K. J., Hwang, S.-W., Lee, S. M., Harburg, D. V., Krueger, N. A., Shin, J., Gamble, P., Cheng, H., Yu, S., et al. (2016) · Nature · doi:10.1038/nature16492 · Cited by 998
Biodegradable and flexible arterial-pulse sensor for the wireless monitoring of blood flow
Boutry, C. M., Beker, L., Kaizawa, Y., Vassos, C., Tran, H., Hinckley, A. C., Pfattner, R., Niu, S., Li, J., Claverie, J., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0336-5 · Cited by 862
Foot Plantar Pressure Measurement System: A Review
Abdul Razak, A. H., Zayegh, A., Begg, R. K., & Wahab, Y. (2012) · Sensors · doi:10.3390/s120709884 · Cited by 817
A stretchable and biodegradable strain and pressure sensor for orthopaedic application
Boutry, C. M., Kaizawa, Y., Schroeder, B. C., Chortos, A., Legrand, A., Wang, Z., Chang, J., Fox, P., & Bao, Z. (2018) · Nature Electronics · doi:10.1038/s41928-018-0071-7 · Cited by 667
Ag Nanowire Reinforced Highly Stretchable Conductive Fibers for Wearable Electronics
Lee, S., Shin, S., Lee, S., Seo, J., Lee, J., Son, S., Cho, H. J., Algadi, H., Al‐Sayari, S., Kim, D. E., et al. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201500628 · Cited by 605
Self-citationTendon and ligament regeneration and repair: Clinical relevance and developmental paradigm
Yang, G., Rothrauff, B. B., & Tuan, R. S. (2013) · Birth Defects Research Part C: Embryo Today: Reviews · doi:10.1002/bdrc.21041 · Cited by 469
Capacitive Soft Strain Sensors via Multicore–Shell Fiber Printing
Frutiger, A., Muth, J. T., Vogt, D. M., Mengüç, Y., Campo, A., Valentine, A. D., Walsh, C. J., & Lewis, J. A. (2015) · Advanced Materials · doi:10.1002/adma.201500072 · Cited by 468
The mechanical properties of the two bundles of the human posterior cruciate ligament
Race, A., & Amis, A. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90028-0 · Cited by 452
Influence of static stretching on viscoelastic properties of human tendon structures in vivo
Kubo, K., Kanehisa, H., Kawakami, Y., & Fukunaga, T. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.520 · Cited by 397
Stretchable Capacitive Sensors of Torsion, Strain, and Touch Using Double Helix Liquid Metal Fibers
Cooper, C. B., Arutselvan, K., Liu, Y., Armstrong, D., Lin, Y., Khan, M. R., Genzer, J., & Dickey, M. D. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201605630 · Cited by 365
Lion, A. (1996) · Continuum Mechanics and Thermodynamics · doi:10.1007/bf01181853 · Cited by 319
Relation between blood pressure and pulse wave velocity for human arteries
Ma, Y., Choi, J., Hourlier-Fargette, A., Xue, Y., Chung, H. U., Lee, J. Y., Wang, X., Xie, Z., Kang, D., Wang, H., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1814392115 · Cited by 309
Self-citationHigh‐Density Stretchable Electrode Grids for Chronic Neural Recording
Tybrandt, K., Khodagholy, D., Dielacher, B., Stauffer, F., Renz, A. F., Buzsáki, G., & Vörös, J. (2018) · Advanced Materials · doi:10.1002/adma.201706520 · Cited by 286
Self-citationLee, J., Shin, S., Lee, S., Song, J., Kang, S., Han, H., Kim, S., Kim, S., Seo, J., Kim, D., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07795 · Cited by 282
Self-citationElectromechanical cardioplasty using a wrapped elasto-conductive epicardial mesh
Park, J., Choi, S., Janardhan, A. H., Lee, S.-Y., Raut, S., Soares, J., Shin, K., Yang, S., Lee, C., Kang, K.-W., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aad8568 · Cited by 253
Flexible, sticky, and biodegradable wireless device for drug delivery to brain tumors
Lee, J., Cho, H. R., Cha, G. D., Seo, H., Lee, S., Park, C.-K., Kim, J. W., Qiao, S., Wang, L., Kang, D., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-13198-y · Cited by 246
Self-citationRoriz, P., Carvalho, L., Frazão, O., Santos, J. L., & Simões, J. A. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.01.054 · Cited by 226
Strain measurement in lateral ankle ligaments
Colville, M. R., Marder, R. A., Boyle, J. J., & Zarins, B. (1990) · The American Journal of Sports Medicine · doi:10.1177/036354659001800214 · Cited by 213
Superelastic Multimaterial Electronic and Photonic Fibers and Devices via Thermal Drawing
Qu, Y., Nguyen‐Dang, T., Page, A. G., Yan, W., Das Gupta, T., Rotaru, G. M., Rossi, R. M., Favrod, V. D., Bartolomei, N., & Sorin, F. (2018) · Advanced Materials · doi:10.1002/adma.201707251 · Cited by 190
Organic electronics for high-resolution electrocorticography of the human brain
Khodagholy, D., Gelinas, J. N., Zhao, Z., Yeh, M., Long, M., Greenlee, J. D., Doyle, W., Devinsky, O., & Buzsáki, G. (2016) · Science Advances · doi:10.1126/sciadv.1601027 · Cited by 184
Age‐related changes in mechanical properties of the Achilles tendon
Waugh, C. M., Blazevich, A. J., Fath, F., & Korff, T. (2012) · Journal of Anatomy · doi:10.1111/j.1469-7580.2011.01461.x · Cited by 176
Sim, K., Rao, Z., Kim, H.-J., Thukral, A., Shim, H., & Yu, C. (2019) · Science Advances · doi:10.1126/sciadv.aav5749 · Cited by 167
Self-citationPark, J., Ahn, D. B., Kim, J., Cha, E., Bae, B.-S., Lee, S.-Y., & Park, J.-U. (2019) · Science Advances · doi:10.1126/sciadv.aay0764 · Cited by 165
Bai, W., Shin, J. H., Fu, R., Kandela, I. K., Lu, D., Ni, X., Park, Y., Liu, Z., Hang, T., Wu, D., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0435-y · Cited by 149
Microstructural origin of resistance–strain hysteresis in carbon nanotube thin film conductors
Jin, L., Chortos, A., Lian, F., Pop, E., Linder, C., Bao, Z., & Cai, W. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1717217115 · Cited by 144
All-in-one stretchable coaxial-fiber strain sensor integrated with high-performing supercapacitor
Pan, Z., Yang, J., Li, L., Gao, X., Kang, L., Zhang, Y., Zhang, Q., Kou, Z., Zhang, T., Wei, L., et al. (2019) · Energy storage materials · doi:10.1016/j.ensm.2019.10.023 · Cited by 130
Kim, S. B., Lee, K., Raj, M. S., Lee, B., Reeder, J. T., Koo, J., Hourlier‐Fargette, A., Bandodkar, A. J., Won, S. M., Sekine, Y., et al. (2018) · Small · doi:10.1002/smll.201802876 · Cited by 115
Dautta, M., Alshetaiwi, M., Escobar, J. T., & Tseng, P. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112004 · Cited by 106
Highly Stretchable, Weavable, and Washable Piezoresistive Microfiber Sensors
Yu, L., Yeo, J. C., Soon, R. H., Yeo, T., Lee, H. H., & Lim, C. T. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b19823 · Cited by 101
The future of performance‐related sports biomechanics research
Yeadon, M. R., & Challis, J. H. (1994) · Journal of Sports Sciences · doi:10.1080/02640419408732156 · Cited by 97
Lai, A., Schache, A. G., Lin, Y.-C., & Pandy, M. G. (2014) · Journal of Experimental Biology · doi:10.1242/jeb.100826 · Cited by 94
Soft tubular microfluidics for 2D and 3D applications
Xi, W., Kong, F., Yeo, J. C., Yu, L., Sonam, S., Dao, M., Gong, X., & Lim, C. T. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1712195114 · Cited by 89
Ultrathin and Wearable Microtubular Epidermal Sensor for Real‐Time Physiological Pulse Monitoring
Xi, W., Yeo, J. C., Yu, L., Zhang, S., & Lim, C. T. (2017) · Advanced Materials Technologies · doi:10.1002/admt.201700016 · Cited by 78
McGilvray, K. C., Unal, E., Troyer, K. L., Santoni, B. G., Palmer, R. H., Easley, J. T., Demir, H. V., & Puttlitz, C. M. (2015) · Journal of Orthopaedic Research · doi:10.1002/jor.22918 · Cited by 74
Farris, D. J., Trewartha, G., & McGuigan, P. M. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.12.015 · Cited by 71
Micro-needle implantable electrochemical oxygen sensor: ex-vivo and in-vivo studies
Rivas, L., Dulay, S. B., Miserere, S., Plà, L., Berdún, S., Parra, J., Eixarch, E., Gratacós, E., Illa, M., Mir, M., et al. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112028 · Cited by 71
Li, J., Wang, L., Wang, X., Yang, Y., Hu, Z., Liu, L., & Huang, Y. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b15546 · Cited by 61
Stauffer, F., Zhang, Q., Tybrandt, K., Zambrano, B. L., Hengsteler, J., Stoll, A., Trueeb, C., Hagander, M., Sujata, J., Hoffmann, F., et al. (2018) · Advanced Materials Technologies · doi:10.1002/admt.201800031 · Cited by 60
Self-citationRogers, J., Malliaras, G., & Someya, T. (2018) · Science Advances · doi:10.1126/sciadv.aav1889 · Cited by 53
Dual-Core Capacitive Microfiber Sensor for Smart Textile Applications
Yu, L., Feng, Y., Selven, D. S. O. M. T., Yao, L., Soon, R. H., Yeo, J. C., & Lim, C. T. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b10937 · Cited by 51
Strain mapping in the Achilles tendon – A systematic review
Bogaerts, S., Desmet, H., Slagmolen, P., & Peers, K. H. E. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.02.057 · Cited by 49
Kim, Y. J., Seo, S. W., Park, S. B., Yang, J. J., Lee, J. S., Lee, J., Jang, Y. K., Kim, S. T., Lee, K.-H., Lee, J. M., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-02046-y · Cited by 47
Self-citationTop-Down Strategy of Implantable Biosensor Using Adaptable, Porous Hollow Fibrous Membrane
Zhou, J., Ma, Z., Hong, X., Wu, H., Ma, S., Li, Y., Chen, D., Yu, H., & Huang, X. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00035 · Cited by 43
Outcome of early active mobilization after flexor tendons repair in zones II-V in hand
Saini, N., Kundnani, V. G., Patni, P., & Gupta, S. (2010) · Indian Journal of Orthopaedics · doi:10.4103/0019-5413.65155 · Cited by 39
Orientation changes in the cruciate ligaments of the knee during skeletal growth: A porcine model
Cone, S. G., Simpson, S. G., Piedrahita, J. A., Fordham, L. A., Spang, J. T., & Fisher, M. B. (2017) · Journal of Orthopaedic Research® · doi:10.1002/jor.23594 · Cited by 26
Review of Flexor Tendon Rehabilitation Protocols Following Zone II Repair
Hein, C., Wilton, P. J., & Wongworawat, M. D. (2015) · Critical Reviews in Physical and Rehabilitation Medicine · doi:10.1615/critrevphysrehabilmed.2015013919 · Cited by 6
Cited by
Neuromorphic sensorimotor loop embodied by monolithically integrated, low-voltage, soft e-skin
Wang, W., Jiang, Y., Zhong, D., Zhang, Z., Choudhury, S., Lai, J.-C., Gong, H., Niu, S., Yan, X., Zheng, Y., et al. (2023) · Science · doi:10.1126/science.ade0086 · Cited by 788
Smart textiles for personalized healthcare
Libanori, A., Chen, G., Zhao, X., Zhou, Y., & Chen, J. (2022) · Nature Electronics · doi:10.1038/s41928-022-00723-z · Cited by 739
Electronic Textiles for Wearable Point-of-Care Systems
Chen, G., Xiao, X., Zhao, X., Tat, T., Bick, M., & Chen, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00502 · Cited by 688
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Skin-inspired soft bioelectronic materials, devices and systems
Zhao, C., Park, J., Root, S. E., & Bao, Z. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00194-1 · Cited by 408
“Owing to the simplicity of the components, soft and stretchable passive tag systems have been fabricated using entirely stretchable materials, or biodegradable materials, which makes them attractive for skin-mounted and implantable sensing applications 154,155,262 .”
Metadata
- Authors
- Lee, J., Ihle, S. J., Pellegrino, G. S., Kim, H., Yea, J., Jeon, C.-Y., Son, H.-C., Jin, C., Eberli, D., Schmid, F., Zambrano, B. L., Renz, A. F., Forró, C., Choi, H., Jang, K.-I., Küng, R., & Vörös, J.
- Affiliations
- Daegu Gyeongbuk Institute of Science and Technology (KR)
- ETH Zurich (CH)
- Korea Research Institute of Bioscience and Biotechnology (KR)
- University of Zurich (CH)
- ZHAW Zurich University of Applied Sciences (CH)
- Corresponding author
- Lee, Jaehong
- ORCID
- Venue
- Nature Electronics
- Published
- 2021-04-01
- Volume
- 4
- Issue
- 4
- Pages
- 291-301
- ISSN
- 2520-1131 (ISSN-L)
- OpenAlex
- W3148153035
- Semantic Scholar
- d5a28c94cc74e55b4360ef6eaee9eec23a8539ef
- Cited by
- 253
- References
- 48
- Citations by year
- 2026: 31 · 2025: 56 · 2024: 77 · 2023: 45 · 2022: 33 · 2021: 11
- FWCI
- 12.62
- Type
- journal article
- Language
- en
- Open access
- Licence
- cc-by-nc-nd
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature Electronics (publishedVersion)
- Zürcher Hochschule für Angewandte Wissenschaften digital collection (Zurich University of Applied Sciences) (submittedVersion, cc-by-nc-nd)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
- Keywords
- wireless readout, induction coil, implantable sensors, Achilles tendon
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.