Optical Coherence Tomography: An Emerging Technology for Biomedical Imaging and Optical Biopsy
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Optical coherence tomography (OCT) is an emerging technology for performing high-resolution cross-sectional imaging. OCT is analogous to ultrasound imaging, except that it uses light instead of sound. OCT can provide cross-sectional images of tissue structure on the micron scale in situ and in real time. Using OCT in combination with catheters and endoscopes enables high-resolution intraluminal imaging of organ systems. OCT can function as a type of optical biopsy and is a powerful imaging technology for medical diagnostics because unlike conventional histopathology which requires removal of a tissue specimen and processing for microscopic examination, OCT can provide images of tissue in situ and in real time. OCT can be used where standard excisional biopsy is hazardous or impossible, to reduce sampling errors associated with excisional biopsy, and to guide interventional procedures. In this paper, we review OCT technology and describe its potential biomedical and clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Self-citationThe Pathogenesis of Coronary Artery Disease and the Acute Coronary Syndromes
Epstein, F. H., Fuster, V., Badimon, L., Badimon, J. J., & Chesebro, J. H. (1992) · New England Journal of Medicine · doi:10.1056/nejm199201303260506 · Cited by 3,725
The Pathogenesis of Coronary Artery Disease and the Acute Coronary Syndromes
Epstein, F. H., Fuster, V., Badimon, L., Badimon, J. J., & Chesebro, J. H. (1992) · New England Journal of Medicine · doi:10.1056/nejm199201233260406 · Cited by 2,717
Davies, M. J., & Thomas, A. C. (1985) · Heart · doi:10.1136/hrt.53.4.363 · Cited by 1,985
The pathogenesis of coronary artery disease and the acute coronary syndromes (First of two parts)
Fuster, V. (1992) · New England Journal of Medicine · Cited by 1,954
Optical Coherence Tomography of the Human Retina
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100030081025 · Cited by 1,634
In Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography
Tearney, G. J., Brezinski, M. E., Bouma, B. E., Boppart, S. A., Pitris, C., Southern, J. F., & Fujimoto, J. G. (1997) · Science · doi:10.1126/science.276.5321.2037 · Cited by 1,364
Self-citationImaging of Macular Diseases with Optical Coherence Tomography
Puliafito, C. A., Hee, M. R., Lin, C. P., Reichel, E., Schuman, J. S., Duker, J. S., Izatt, J. A., Swanson, E. A., & Fujimoto, J. G. (1995) · Ophthalmology · doi:10.1016/s0161-6420(95)31032-9 · Cited by 1,267
Self-citationRICHARDSON, P. (1989) · The Lancet · doi:10.1016/s0140-6736(89)90953-7 · Cited by 1,258
Cited by
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Optical coherence tomography for ultrahigh resolution in vivo imaging
Fujimoto, J. G. (2003) · Nature Biotechnology · doi:10.1038/nbt892 · Cited by 1,033
Self-citationUltrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962
Self-citationHartl, I., Li, X. D., Chudoba, C., Ghanta, R. K., Ko, T. H., Fujimoto, J. G., Ranka, J. K., & Windeler, R. S. (2001) · Optics Letters · doi:10.1364/ol.26.000608 · Cited by 852
Self-citationReview of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
Pogue, B. W., & Patterson, M. S. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2335429 · Cited by 837
Diabetic Macular Edema: Pathogenesis and Treatment
Bhagat, N., Grigorian, R. A., Tutela, A., & Zarbin, M. A. (2009) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2008.10.001 · Cited by 571
Illuminating the metastatic process
Sahai, E. (2007) · Nature Reviews Cancer · doi:10.1038/nrc2229 · Cited by 569
Optical methods for distance and displacement measurements
Berkovic, G., & Shafir, E. (2012) · Advances in Optics and Photonics · doi:10.1364/aop.4.000441 · Cited by 411
Age-Related Macular Degeneration
Thomas, C. J., Mirza, R. G., & Gill, M. K. (2021) · Medical Clinics of North America · doi:10.1016/j.mcna.2021.01.003 · Cited by 399
Intraoperative Evaluation of Breast Tumor Margins with Optical Coherence Tomography
Nguyen, F. T., Zysk, A. M., Chaney, E. J., Kotynek, J. G., Oliphant, U. J., Bellafiore, F. J., Rowland, K. M., Johnson, P. A., & Boppart, S. A. (2009) · Cancer Research · doi:10.1158/0008-5472.can-08-4340 · Cited by 387
Self-citationRetinal thickness decreases with age: an OCT study
Alamouti, B. (2003) · British Journal of Ophthalmology · doi:10.1136/bjo.87.7.899 · Cited by 385
Biocompatible Silk Printed Optical Waveguides
Parker, S. T., Domachuk, P., Amsden, J., Bressner, J., Lewis, J. A., Kaplan, D. L., & Omenetto, F. G. (2009) · Advanced Materials · doi:10.1002/adma.200801580 · Cited by 351
Quantitative Phase Imaging: Recent Advances and Expanding Potential in Biomedicine
Nguyen, T. L., Pradeep, S., Judson-Torres, R. L., Reed, J., Teitell, M. A., & Zangle, T. A. (2022) · ACS Nano · doi:10.1021/acsnano.1c11507 · Cited by 318
Genomic Instability of iPSCs: Challenges Towards Their Clinical Applications
Yoshihara, M., Hayashizaki, Y., & Murakawa, Y. (2017) · Stem Cell Reviews and Reports · doi:10.1007/s12015-016-9680-6 · Cited by 283
“of iPSC-derived RPE cell transplantation, ocular fundus can be observed noninvasively [10], and morphological changes of transplanted RPE can be monitored at cellular levels using optical coherence tomography [112, 113].”
MethodIngestible electronics for diagnostics and therapy
Steiger, C., Abramson, A., Nadeau, P., Chandrakasan, A. P., Langer, R., & Traverso, G. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0070-3 · Cited by 274
Optical coherence elastography for tissue characterization: a review
Wang, S., & Larin, K. V. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201400108 · Cited by 270
Recent advances in different modal imaging-guided photothermal therapy
Chen, Q., Wen, J., Li, H., Xu, Y., Liu, F., & Sun, S. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.08.022 · Cited by 265
Optical imaging in drug discovery and diagnostic applications
LICHA, K., & OLBRICH, C. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2005.01.021 · Cited by 263
It's not just about anatomy: In vivo bioluminescence imaging as an eyepiece into biology
Contag, C. H., & Ross, B. D. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10178 · Cited by 256
Noninvasive real-time imaging of apoptosis
Laxman, B., Hall, D. E., Bhojani, M. S., Hamstra, D. A., Chenevert, T. L., Ross, B. D., & Rehemtulla, A. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.252644499 · Cited by 247
Bessel Beam: Significance and Applications—A Progressive Review
Khonina, S. N., Kazanskiy, N. L., Karpeev, S. V., & Butt, M. A. (2020) · Micromachines · doi:10.3390/mi11110997 · Cited by 235
Neerken, S., Lucassen, G. W., Bisschop, M. A., Lenderink, E., & Nuijs, T. (. M. ). (2004) · Journal of Biomedical Optics · doi:10.1117/1.1645795 · Cited by 216
Microvascular imaging: techniques and opportunities for clinical physiological measurements
Allen, J., & Howell, K. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/7/r91 · Cited by 208
“A Michelson interferometer is often used to perform the low-coherence interferometry for OCT (Fujimoto et al 2000).”
MethodOCT imaging of skin cancer and other dermatological diseases
Mogensen, M., Thrane, L., Jørgensen, T. M., Andersen, P. E., & Jemec, G. B. E. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910020 · Cited by 201
A Review of Three-Dimensional Imaging Technologies for Pavement Distress Detection and Measurements
Mathavan, S., Kamal, K., & Rahman, M. (2015) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2015.2428655 · Cited by 192
“Optical coherence tomography (OCT) is another viable technique that is based on interferometry [62].”
MethodMicrofluidic 3D models of cancer
Sung, K. E., & Beebe, D. J. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.07.002 · Cited by 190
Noncontact depth-resolved micro-scale optical coherence elastography of the cornea
Wang, S., & Larin, K. V. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.003807 · Cited by 177
Wang, R. K. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/13/307 · Cited by 159
Lentsch, G., Baugh, E. G., Lee, B., Aszterbaum, M., Zachary, C. B., Kelly, K. M., & Balu, M. (2022) · Journal of Investigative Dermatology · doi:10.1016/j.jid.2022.01.016 · Cited by 41
Computer-Aided Diagnosis by Tissue Image Analysis as an Optical Biopsy in Hysteroscopy
Tanos, V., Neofytou, M., Tanos, P., Pattichis, C. S., & Pattichis, M. S. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms232112782 · Cited by 10
“and the following texture features [17,18] were computed: Statistical features (SF): SF features describe the gray-level histogram distribution without considering spatial independence.”
Method
Metadata
- Authors
- Fujimoto, J. G., Pitris, C., Boppart, S. A., & Brezinski, M. E.
- Venue
- Neoplasia
- Publisher
- Elsevier BV
- Published
- 2000-01
- Volume
- 2
- Issue
- 1-2
- Pages
- 9-25
- ISSN
- 1476-5586 (ISSN-L)
- OpenAlex
- W1974420926
- Cited by
- 1,138
- References
- 45
- FWCI
- 17.51
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.