Optical Coherence Tomography: An Emerging Technology for Biomedical Imaging and Optical Biopsy
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Optical coherence tomography (OCT) is an emerging technology for performing high-resolution cross-sectional imaging. OCT is analogous to ultrasound imaging, except that it uses light instead of sound. OCT can provide cross-sectional images of tissue structure on the micron scale in situ and in real time. Using OCT in combination with catheters and endoscopes enables high-resolution intraluminal imaging of organ systems. OCT can function as a type of optical biopsy and is a powerful imaging technology for medical diagnostics because unlike conventional histopathology which requires removal of a tissue specimen and processing for microscopic examination, OCT can provide images of tissue in situ and in real time. OCT can be used where standard excisional biopsy is hazardous or impossible, to reduce sampling errors associated with excisional biopsy, and to guide interventional procedures. In this paper, we review OCT technology and describe its potential biomedical and clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Self-citationThe Pathogenesis of Coronary Artery Disease and the Acute Coronary Syndromes
Epstein, F. H., Fuster, V., Badimon, L., Badimon, J. J., & Chesebro, J. H. (1992) · New England Journal of Medicine · doi:10.1056/nejm199201303260506 · Cited by 3,725
The Pathogenesis of Coronary Artery Disease and the Acute Coronary Syndromes
Epstein, F. H., Fuster, V., Badimon, L., Badimon, J. J., & Chesebro, J. H. (1992) · New England Journal of Medicine · doi:10.1056/nejm199201233260406 · Cited by 2,717
Davies, M. J., & Thomas, A. C. (1985) · Heart · doi:10.1136/hrt.53.4.363 · Cited by 1,985
The pathogenesis of coronary artery disease and the acute coronary syndromes (First of two parts)
Fuster, V. (1992) · New England Journal of Medicine · Cited by 1,954
Optical Coherence Tomography of the Human Retina
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100030081025 · Cited by 1,634
In Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography
Tearney, G. J., Brezinski, M. E., Bouma, B. E., Boppart, S. A., Pitris, C., Southern, J. F., & Fujimoto, J. G. (1997) · Science · doi:10.1126/science.276.5321.2037 · Cited by 1,364
Self-citationImaging of Macular Diseases with Optical Coherence Tomography
Puliafito, C. A., Hee, M. R., Lin, C. P., Reichel, E., Schuman, J. S., Duker, J. S., Izatt, J. A., Swanson, E. A., & Fujimoto, J. G. (1995) · Ophthalmology · doi:10.1016/s0161-6420(95)31032-9 · Cited by 1,267
Self-citationRICHARDSON, P. (1989) · The Lancet · doi:10.1016/s0140-6736(89)90953-7 · Cited by 1,258
In vivo ultrahigh-resolution optical coherence tomography
Drexler, W., Morgner, U., Käertner, F. X., Pitris, C., Boppart, S. A., Li, X. D., Ippen, E. P., & Fujimoto, J. G. (1999) · Optics Letters · doi:10.1364/ol.24.001221 · Cited by 945
Self-citationMicrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence Tomography
Izatt, J. A. (1994) · Archives of Ophthalmology · doi:10.1001/archopht.1994.01090240090031 · Cited by 927
In vivo retinal imaging by optical coherence tomography
Swanson, E. A., Izatt, J. A., Lin, C. P., Fujimoto, J. G., Schuman, J. S., Hee, M. R., Huang, D., & Puliafito, C. A. (1993) · Optics Letters · doi:10.1364/ol.18.001864 · Cited by 918
Self-citationOptical biopsy and imaging using optical coherence tomography
Fujimoto, J. G., Brezinski, M. E., Tearney, G. J., Boppart, S. A., Bouma, B., Hee, M. R., Southern, J. F., & Swanson, E. A. (1995) · Nature Medicine · doi:10.1038/nm0995-970 · Cited by 887
Self-citationSchuman, J. S. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100050054031 · Cited by 879
Quantitative Assessment of Macular Edema With Optical Coherence Tomography
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100080071031 · Cited by 710
Effects of fibrous cap thickness on peak circumferential stress in model atherosclerotic vessels.
Loree, H. M., Kamm, R. D., Stringfellow, R. G., & Lee, R. T. (1992) · Circulation Research · doi:10.1161/01.res.71.4.850 · Cited by 676
Reproducibility of Nerve Fiber Layer Thickness Measurements Using Optical Coherence Tomography
Schuman, J. S., Pedut-Kloizman, T., Hertzmark, E., Hee, M. R., Wilkins, J. R., Coker, J. G., Puliafito, C. A., Fujimoto, J. G., & Swanson, E. A. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30410-7 · Cited by 665
Self-citationTopography of diabetic macular edema with optical coherence tomography
Hee, M. R., Puliafito, C. A., Duker, J. S., Reichel, E., Coker, J. G., Wilkins, J. R., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1998) · Ophthalmology · doi:10.1016/s0161-6420(98)93601-6 · Cited by 633
Self-citationOptical coherence-domain reflectometry: a new optical evaluation technique
Youngquist, R. C., Carr, S., & Davies, D. E. N. (1987) · Optics Letters · doi:10.1364/ol.12.000158 · Cited by 597
Optical Coherence Tomography for Optical Biopsy: Properties and Demonstration of Vascular Pathology
Brezinski, M. E., Tearney, G. J., Bouma, B. E., Izatt, J. A., Hee, M. R., Swanson, E. A., Southern, J. F., & Fujimoto, J. G. (1996) · Circulation · doi:10.1161/01.cir.93.6.1206 · Cited by 566
Self-citationEye-length measurement by interferometry with partially coherent light
Fercher, A. F., Mengedoht, K., & Werner, W. (1988) · Optics Letters · doi:10.1364/ol.13.000186 · Cited by 516
Optical Coherence Tomography of Macular Holes
Hee, M. R., Puliafito, C. A., Wong, C., Duker, J. S., Reichel, E., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1995) · Ophthalmology · doi:10.1016/s0161-6420(95)30959-1 · Cited by 503
Self-citationOptical Coherence Tomography of Ocular Diseases
Schuman, J. S., Fujimoto, J. G., Duker, J., & Ishikawa, H. (2024) · CRC Press eBooks · doi:10.1201/9781003525455 · Cited by 484
Self-citationIn Vivo Optical Coherence Tomography
Fercher, A. F., Hitzenberger, C. K., Drexler, W., Kamp, G., & Sattmann, H. (1993) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)71762-3 · Cited by 467
High-speed phase- and group-delay scanning with a grating-based phase control delay line
Tearney, G. J., Bouma, B. E., & Fujimoto, J. G. (1997) · Optics Letters · doi:10.1364/ol.22.001811 · Cited by 449
Self-citationOptical Coherence Tomography of Age-related Macular Degeneration and Choroidal Neovascularization
Hee, M. R., Baumal, C. R., Puliafito, C. A., Duker, J. S., Reichel, E., Wilkins, J. R., Coker, J. G., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30512-5 · Cited by 416
Self-citationTakada, K., Yokohama, I., Chida, K., & Noda, J. (1987) · Applied Optics · doi:10.1364/ao.26.001603 · Cited by 371
Optical coherence tomography and microscopy in gastrointestinal tissues
Izatt, J. A., Kulkarni, M. D., Wang, H.-W., Kobayashi, K., & Sivak, M. V. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.577331 · Cited by 350
Sudden coronary death in the United States: 1980-1985.
Gillum, R. F. (1989) · Circulation · doi:10.1161/01.cir.79.4.756 · Cited by 340
Introduction to vascular ultrasonography
Zwiebel, W. J. (1992) · Cited by 316
High-resolution optical coherence tomographic imaging using a mode-locked Ti:Al_2O_3 laser source
Bouma, B., Brezinski, M. E., Fujimoto, J. G., Tearney, G. J., Boppart, S. A., & Hee, M. R. (1995) · Optics Letters · doi:10.1364/ol.20.001486 · Cited by 283
Self-citationHigh resolution in vivo intra-arterial imaging with optical coherence tomography
Fujimoto, J. G., Boppart, S. A., Tearney, G. J., Bouma, B. E., Pitris, C., & Brezinski, M. E. (1999) · Heart · doi:10.1136/hrt.82.2.128 · Cited by 276
Self-citationIn vivo cellular optical coherence tomography imaging
Boppart, S. A., Bouma, B. E., Pitris, C., Southern, J. F., Brezinski, M. E., & Fujimoto, J. G. (1998) · Nature Medicine · doi:10.1038/nm0798-861 · Cited by 268
Self-citationSubsurface Imaging of Living Skin with Optical Coherence Microscopy
Schmitt, J. M., Yadlowsky, M. J., & Bonner, R. F. (1995) · Dermatology · doi:10.1159/000246523 · Cited by 251
Brezinski, M. E., Tearney, G. J., Weissman, N. J., Boppart, S. A., Bouma, B. E., Hee, M. R., Weyman, A. E., Swanson, E. A., Southern, J. F., & Fujimoto, J. G. (1997) · Heart · doi:10.1136/hrt.77.5.397 · Cited by 241
Self-citationOptical Coherence Tomography of Central Serous Chorioretinopathy
HEE, M. R., PULIAFITO, C. A., WONG, C., REICHEL, E., DUKER, J. S., SCHUMAN, J. S., SWANSON, E. A., & FUJIMOTO, J. G. (1995) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)73760-2 · Cited by 205
Self-citationColston, B. W., Sathyam, U. S., DaSilva, L. B., Everett, M. J., Stroeve, P., & Otis, L. L. (1998) · Optics Express · doi:10.1364/oe.3.000230 · Cited by 197
Optical coherence tomography of central serous chorioretinopathy
Ju-fen, H. (2010) · Cited by 183
Boppart, S. A., Tearney, G. J., Bouma, B. E., Southern, J. F., Brezinski, M. E., & Fujimoto, J. G. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.9.4256 · Cited by 174
Self-citationMicron‐resolution ranging of cornea anterior chamber by optical reflectometry
Huang, D., Wang, J., Lin, C. P., Puliafito, C. A., & Fujimoto, J. G. (1991) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900110506 · Cited by 153
Self-citationSubmillimeter optical reflectometry
Gilgen, H. H., Novak, R., Salathé, R. P., Hodel, W. J., & Beaud, P. (1989) · Journal of Lightwave Technology · doi:10.1109/50.32387 · Cited by 142
Imaging developing neural morphology using optical coherence tomography
Boppart, S. A., Bouma, B. E., Brezinski, M. E., Tearney, G. J., & Fujimoto, J. G. (1996) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(96)00104-5 · Cited by 80
Self-citationIntravascular ultrasound of the coronary arteries: Current applications and future directions
Nissen, S. E., Gurley, J. C., Booth, D. C., & DeMaria, A. N. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)90642-c · Cited by 60
SECONDARY NERVE RECONSTRUCTION
Wyrick, J. D., & Stern, P. J. (1992) · Hand Clinics · doi:10.1016/s0749-0712(21)00939-2 · Cited by 15
Cited by
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Optical coherence tomography for ultrahigh resolution in vivo imaging
Fujimoto, J. G. (2003) · Nature Biotechnology · doi:10.1038/nbt892 · Cited by 1,033
Self-citationUltrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962
Self-citationHartl, I., Li, X. D., Chudoba, C., Ghanta, R. K., Ko, T. H., Fujimoto, J. G., Ranka, J. K., & Windeler, R. S. (2001) · Optics Letters · doi:10.1364/ol.26.000608 · Cited by 852
Self-citationReview of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
Pogue, B. W., & Patterson, M. S. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2335429 · Cited by 837
Metadata
- Authors
- Fujimoto, J. G., Pitris, C., Boppart, S. A., & Brezinski, M. E.
- Venue
- Neoplasia
- Publisher
- Elsevier BV
- Published
- 2000-01
- Volume
- 2
- Issue
- 1-2
- Pages
- 9-25
- ISSN
- 1476-5586 (ISSN-L)
- OpenAlex
- W1974420926
- Cited by
- 1,138
- References
- 45
- FWCI
- 17.51
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.