The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Image-Guided Transcranial Focused Ultrasound Stimulates Human Primary Somatosensory Cortex
Open accessAbstract
Focused ultrasound (FUS) has recently been investigated as a new mode of non-invasive brain stimulation, which offers exquisite spatial resolution and depth control. We report on the elicitation of explicit somatosensory sensations as well as accompanying evoked electroencephalographic (EEG) potentials induced by FUS stimulation of the human somatosensory cortex. As guided by individual-specific neuroimage data, FUS was transcranially delivered to the hand somatosensory cortex among healthy volunteers. The sonication elicited transient tactile sensations on the hand area contralateral to the sonicated hemisphere, with anatomical specificity of up to a finger, while EEG recordings revealed the elicitation of sonication-specific evoked potentials. Retrospective numerical simulation of the acoustic propagation through the skull showed that a threshold of acoustic intensity may exist for successful cortical stimulation. The neurological and neuroradiological assessment before and after the sonication, along with strict safety considerations through the individual-specific estimation of effective acoustic intensity in situ and thermal effects, showed promising initial safety profile; however, equal/more rigorous precautionary procedures are advised for future studies. The transient and localized stimulation of the brain using image-guided transcranial FUS may serve as a novel tool for the non-invasive assessment and modification of region-specific brain function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Deisseroth, K. (2011) · Nature Methods · doi:10.1038/nmeth.f.324 · Cited by 1,863
High-intensity focused ultrasound in the treatment of solid tumours
Kennedy, J. E. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1591 · Cited by 1,282
Transcranial focused ultrasound modulates the activity of primary somatosensory cortex in humans
Legon, W., Sato, T. F., Opitz, A., Mueller, J., Barbour, A., Williams, A., & Tyler, W. J. (2014) · Nature Neuroscience · doi:10.1038/nn.3620 · Cited by 981
Transcranial Pulsed Ultrasound Stimulates Intact Brain Circuits
Tufail, Y., Matyushov, A., Baldwin, N., Tauchmann, M. L., Georges, J., Yoshihiro, A., Tillery, S. I. H., & Tyler, W. J. (2010) · Neuron · doi:10.1016/j.neuron.2010.05.008 · Cited by 977
A Pilot Study of Focused Ultrasound Thalamotomy for Essential Tremor
Elias, W. J., Huss, D., Voss, T., Loomba, J., Khaled, M., Zadicario, E., Frysinger, R. C., Sperling, S. A., Wylie, S., Monteith, S. J., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1300962 · Cited by 875
Noninvasive Human Brain Stimulation
Wagner, T., Valero-Cabre, A., & Pascual-Leone, A. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.061206.133100 · Cited by 873
Fregni, F., & Pascual-Leone, A. (2007) · Nature Clinical Practice Neurology · doi:10.1038/ncpneuro0530 · Cited by 823
Ultrasound–biophysics mechanisms
O’Brien, W. D. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.010 · Cited by 745
Focused ultrasound modulates region-specific brain activity
Yoo, S.-S., Bystritsky, A., Lee, J.-H., Zhang, Y., Fischer, K., Min, B.-K., McDannold, N. J., Pascual-Leone, A., & Jolesz, F. A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.02.058 · Cited by 613
Self-citationAllison, T., McCarthy, G., Wood, C. C., Darcey, T. M., Spencer, D. D., & Williamson, P. D. (1989) · Journal of Neurophysiology · doi:10.1152/jn.1989.62.3.694 · Cited by 566
Intramembrane cavitation as a unifying mechanism for ultrasound-induced bioeffects
Krasovitski, B., Frenkel, V., Shoham, S., & Kimmel, E. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1015771108 · Cited by 550
MOTOR REORGANIZATION AFTER UPPER LIMB AMPUTATION IN MAN: A STUDY WITH FOCAL MAGNETIC STIMULATION
COHEN, L. G., BANDINELLI, S., FINDLEY, T. W., & HALLETT, M. (1991) · Brain · doi:10.1093/brain/114.1.615 · Cited by 534
Effective Parameters for Ultrasound-Induced In Vivo Neurostimulation
King, R. L., Brown, J. R., Newsome, W. T., & Pauly, K. B. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.09.009 · Cited by 491
High‐intensity focused ultrasound for noninvasive functional neurosurgery
Martin, E., Jeanmonod, D., Morel, A., Zadicario, E., & Werner, B. (2009) · Annals of Neurology · doi:10.1002/ana.21801 · Cited by 468
The distribution of target registration error in rigid-body point-based registration
Fitzpatrick, J. M., & West, J. B. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.952729 · Cited by 457
Peterchev, A. V., Wagner, T. A., Miranda, P. C., Nitsche, M. A., Paulus, W., Lisanby, S. H., Pascual-Leone, A., & Bikson, M. (2012) · Brain Stimulation · doi:10.1016/j.brs.2011.10.001 · Cited by 429
A review of low-intensity focused ultrasound pulsation
Bystritsky, A., Korb, A. S., Douglas, P. K., Cohen, M. S., Melega, W. P., Mulgaonkar, A. P., DeSalles, A., Min, B.-K., & Yoo, S.-S. (2011) · Brain Stimulation · doi:10.1016/j.brs.2011.03.007 · Cited by 409
Self-citationGeorge, M. S., & Aston-Jones, G. (2010) · Neuropsychopharmacology · doi:10.1038/npp.2009.87 · Cited by 401
Low-Intensity Focused Ultrasound Modulates Monkey Visuomotor Behavior
Deffieux, T., Younan, Y., Wattiez, N., Tanter, M., Pouget, P., & Aubry, J.-F. (2013) · Current Biology · doi:10.1016/j.cub.2013.10.029 · Cited by 392
Hynynen, K., Clement, G. T., McDannold, N., Vykhodtseva, N., King, R., White, P. J., Vitek, S., & Jolesz, F. A. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20118 · Cited by 340
Production of Reversible Changes in the Central Nervous System by Ultrasound
Fry, F. J., Ades, H. W., & Fry, W. J. (1958) · Science · doi:10.1126/science.127.3289.83 · Cited by 339
Libet, B., Alberts, W. W., Wright, E. W., Delattre, L. D., Levin, G., & Feinstein, B. (1964) · Journal of Neurophysiology · doi:10.1152/jn.1964.27.4.546 · Cited by 319
Ultrasonic absorption and attenuation in mammalian tissues
Goss, S. A., Frizzell, L. A., & Dunn, F. (1979) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(79)90086-3 · Cited by 313
Thomas, J.-L., & Fink, M. A. (1996) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.542055 · Cited by 312
Allison, T., McCarthy, G., Wood, C. C., Williamson, P. D., & Spencer, D. D. (1989) · Journal of Neurophysiology · doi:10.1152/jn.1989.62.3.711 · Cited by 300
Focused ultrasound-mediated suppression of chemically-induced acute epileptic EEG activity
Min, B.-K., Bystritsky, A., Jung, K.-I., Fischer, K., Zhang, Y., Maeng, L.-S., In Park, S., Chung, Y.-A., Jolesz, F. A., & Yoo, S.-S. (2011) · BMC Neuroscience · doi:10.1186/1471-2202-12-23 · Cited by 274
Self-citationMiesenböck, G. (2009) · Science · doi:10.1126/science.1174520 · Cited by 255
Transcranial Ultrasound (TUS) Effects on Mental States: A Pilot Study
Hameroff, S., Trakas, M., Duffield, C., Annabi, E., Gerace, M. B., Boyle, P., Lucas, A., Amos, Q., Buadu, A., & Badal, J. J. (2013) · Brain stimulation · doi:10.1016/j.brs.2012.05.002 · Cited by 248
Plaksin, M., Shoham, S., & Kimmel, E. (2014) · Physical Review X · doi:10.1103/physrevx.4.011004 · Cited by 238
Bio-effects and safety of low-intensity, low-frequency ultrasonic exposure
Ahmadi, F., McLoughlin, I. V., Chauhan, S., & ter-Haar, G. (2012) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2012.01.004 · Cited by 224
Human finger somatotopy in areas 3b, 1, and 2: A 7T fMRI study using a natural stimulus
Martuzzi, R., van der Zwaag, W., Farthouat, J., Gruetter, R., & Blanke, O. (2014) · Human Brain Mapping · doi:10.1002/hbm.22172 · Cited by 213
Younan, Y., Deffieux, T., Larrat, B., Fink, M., Tanter, M., & Aubry, J.-F. (2013) · Medical Physics · doi:10.1118/1.4812423 · Cited by 204
Medical and non-medical protection standards for ultrasound and infrasound
Duck, F. A. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.008 · Cited by 187
Perspectives in clinical uses of high-intensity focused ultrasound
Clement, G. T. (2004) · Ultrasonics · doi:10.1016/j.ultras.2004.04.003 · Cited by 186
Focused Ultrasound Effects on Nerve Action Potential in vitro
Colucci, V., Strichartz, G., Jolesz, F., Vykhodtseva, N., & Hynynen, K. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2009.05.002 · Cited by 169
Kyriakou, A., Neufeld, E., Werner, B., Paulides, M. M., Székely, G. J., & Kuster, N. (2013) · International Journal of Hyperthermia · doi:10.3109/02656736.2013.861519 · Cited by 155
Tissue hardness measurement using the radiation force of focused ultrasound
Sugimoto, T., Ueha, S., & Itoh, K. (1990) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.1990.171591 · Cited by 153
Digit Somatotopy within Cortical Areas of the Postcentral Gyrus in Humans
Nelson, A. J., & Chen, R. E. (2008) · Cerebral Cortex · doi:10.1093/cercor/bhm257 · Cited by 152
A simple method for production of trackless focal lesions with focused ultrasound: physical factors
Lele, P. P. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006862 · Cited by 149
Now you feel it—now you don't: ERP correlates of somatosensory awareness
Schubert, R., Blankenburg, F., Lemm, S., Villringer, A., & Curio, G. (2006) · Psychophysiology · doi:10.1111/j.1469-8986.2006.00379.x · Cited by 138
Non-Invasive Brain-to-Brain Interface (BBI): Establishing Functional Links between Two Brains
Yoo, S., Kim, H., Filandrianos, E., TAGHADOS, S. J., & Park, S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0060410 · Cited by 133
Self-citationJohnson, L., Wander, J. D., Sarma, D., Su, D. K., Fetz, E. E., & Ojemann, J. G. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036021 · Cited by 112
Yang, P. S., Kim, H., Lee, W., Böhlke, M., Park, S., Maher, T. J., & Yoo, S. (2012) · Neuropsychobiology · doi:10.1159/000336001 · Cited by 109
Self-citationBrain stimulation in psychiatry and its effects on cognition
Hoy, K. E., & Fitzgerald, P. B. (2010) · Nature Reviews Neurology · doi:10.1038/nrneurol.2010.30 · Cited by 104
Rinaldi, P. C., Jones, J. P., Reines, F., & Price, L. R. (1991) · Brain Research · doi:10.1016/0006-8993(91)90711-4 · Cited by 99
Min, B., Yang, P. S., Böhlke, M., Park, S., Vago, D. R., Maher, T. J., & Yoo, S. (2011) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.20284 · Cited by 94
Self-citationFocused Ultrasound Modifications of Neural Circuit Activity in a Mammalian Brain
Bachtold, M. R., Rinaldi, P. C., Jones, J. P., Reines, F., & Price, L. R. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00014-3 · Cited by 94
Dynamic Response of Model Lipid Membranes to Ultrasonic Radiation Force
Prieto, M. L., Oralkan, Ö., Khuri-Yakub, B. T., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0077115 · Cited by 93
Arana, A. B., Borckardt, J. J., Ricci, R., Anderson, B. S., Li, X., Linder, K. J., Long, J., Sackeïm, H. A., & George, M. S. (2007) · Brain stimulation · doi:10.1016/j.brs.2007.08.006 · Cited by 92
Model of local temperature changes in brain upon functional activation
Collins, C. M., Smith, M. B. H., & Turner, R. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00626.2004 · Cited by 83
Fingersomatotopy in area 3b: an fMRI-study
van Westen, D., Fransson, P., Olsrud, J., Rosén, B., Lundborg, G., & Larsson, E. (2004) · BMC Neuroscience · doi:10.1186/1471-2202-5-28 · Cited by 61
Abler, B., Walter, H., Wunderlich, A. P., Grothe, J., Schönfeldt‐Lecuona, C., Spitzer, M., & Herwig, U. (2005) · Brain Topography · doi:10.1007/s10548-005-6028-y · Cited by 58
Ostrow, L. W., Suchyna, T. M., & Sachs, F. (2011) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2011.05.109 · Cited by 49
Amassian, V. E., Cracco, R. Q., & Maccabee, P. J. (1989) · Brain Research · doi:10.1016/0006-8993(89)91640-5 · Cited by 49
Pascual‐Leone, Á., Cohen, L. G., Brasil-Neto, J. P., Valls‐Solé, J., & Hallett, M. (1994) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(94)90045-0 · Cited by 45
Cited by
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Ultrasound Neuromodulation: A Review of Results, Mechanisms and Safety
Blackmore, J., Shrivastava, S., Sallet, J., Butler, C. R., & Cleveland, R. O. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.12.015 · Cited by 556
Yoo, S., Mittelstein, D. R., Hurt, R. C., Lacroix, J., & Shapiro, M. G. (2022) · Nature Communications · doi:10.1038/s41467-022-28040-1 · Cited by 492
Self-citationTranscranial focused ultrasound stimulation of human primary visual cortex
Lee, W., Kim, H.-C., Jung, Y., Chung, Y. A., Song, I.-U., Lee, J.-H., & Yoo, S.-S. (2016) · Scientific Reports · doi:10.1038/srep34026 · Cited by 415
Self-citationUltrasound modulates ion channel currents
Kubanek, J., Shi, J., Marsh, J., Chen, D., Deng, C., & Cui, J. (2016) · Scientific Reports · doi:10.1038/srep24170 · Cited by 353
Metadata
- Authors
- Lee, W., Kim, H., Jung, Y., Song, I.-U., Chung, Y. A., & Yoo, S.-S.
- Venue
- Scientific Reports
- Published
- 2015-03-04
- Volume
- 5
- Issue
- 1
- Pages
- 8743-8743
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W1979495791
- Cited by
- 414
- References
- 56
- FWCI
- 14.15
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.