The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Continuous particle separation in a microfluidic channel via standing surface acoustic waves (SSAW)
Abstract
This work introduces a method of continuous particle separation through standing surface acoustic wave (SSAW)-induced acoustophoresis in a microfluidic channel. Using this SSAW-based method, particles in a continuous laminar flow can be separated based on their volume, density and compressibility. In this work, a mixture of particles of equal density but dissimilar volumes was injected into a microchannel through two side inlets, sandwiching a deionized water sheath flow injected through a central inlet. A one-dimensional SSAW generated by two parallel interdigital transducers (IDTs) was established across the channel, with the channel spanning a single SSAW pressure node located at the channel center. Application of the SSAW induced larger axial acoustic forces on the particles of larger volume, repositioning them closer to the wave pressure node at the center of the channel. Thus particles were laterally moved to different regions of the channel cross-section based on particle volume. The particle separation method presented here is simple and versatile, capable of separating virtually all kinds of particles (regardless of charge/polarization or optical properties) with high separation efficiency and low power consumption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634
Microscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219
Baret, J.-C., Miller, O. J., Taly, V., Ryckelynck, M., El-Harrak, A., Frenz, L., Rick, C., Samuels, M. L., Hutchison, J. B., Agresti, J. J., et al. (2009) · Lab on a Chip · doi:10.1039/b902504a · Cited by 951
An extracellular matrix microarray for probing cellular differentiation
Flaim, C. J., Chien, S., & Bhatia, S. N. (2005) · Nature Methods · doi:10.1038/nmeth736 · Cited by 803
Continuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Yamada, M., Nakashima, M., & Seki, M. (2004) · Analytical Chemistry · doi:10.1021/ac049863r · Cited by 746
Acoustic radiation pressure on a compressible sphere
Yosioka, K. (1955) · Acustica · Cited by 726
Acoustic tweezers: patterning cells and microparticles using standing surface acoustic waves (SSAW)
Shi, J., Ahmed, D., Mao, X., Lin, S.-C. S., Lawit, A., & Huang, T. J. (2009) · Lab on a Chip · doi:10.1039/b910595f · Cited by 723
Self-citationContinuous particle separation in spiral microchannels using dean flows and differential migration
Bhagat, A. A. S., Kuntaegowdanahalli, S. S., & Papautsky, I. (2008) · Lab on a Chip · doi:10.1039/b807107a · Cited by 656
Free Flow Acoustophoresis: Microfluidic-Based Mode of Particle and Cell Separation
Petersson, F., Åberg, L., Swärd-Nilsson, A.-M., & Laurell, T. (2007) · Analytical Chemistry · doi:10.1021/ac070444e · Cited by 649
Focusing microparticles in a microfluidic channel with standing surface acoustic waves (SSAW)
Shi, J., Mao, X., Ahmed, D., Colletti, A., & Huang, T. J. (2008) · Lab Chip · doi:10.1039/b716321e · Cited by 439
Self-citationA millisecond micromixer via single-bubble-based acoustic streaming
Ahmed, D., Mao, X., Shi, J., Juluri, B. K., & Huang, T. J. (2009) · Lab on a Chip · doi:10.1039/b903687c · Cited by 415
Self-citationSurface acoustic wave (SAW) directed droplet flow in microfluidics for PDMS devices
Franke, T., Abate, A. R., Weitz, D. A., & Wixforth, A. (2009) · Lab on a Chip · doi:10.1039/b906819h · Cited by 369
Surface Acoustic Wave Devices and their Signal Processing Applications
(1989) · Elsevier eBooks · doi:10.1016/b978-0-12-157345-4.x5001-2 · Cited by 367
Planar chip device for PCR and hybridization with surface acoustic wave pump
Guttenberg, Z., Müller, H., Habermüller, H., Geisbauer, A., Pipper, J., Felbel, J., Kielpinski, M., Scriba, J., & Wixforth, A. (2005) · Lab Chip · doi:10.1039/b412712a · Cited by 349
Acoustic manipulation of small droplets
Wixforth, A., Strobl, C., Gauer, C., Toegl, A., Scriba, J., & v. Guttenberg, Z. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2693-z · Cited by 341
Separation of lipids from blood utilizing ultrasonic standing waves in microfluidic channels
Petersson, F., Nilsson, A., Holm, C., Jönsson, H., & Laurell, T. (2004) · The Analyst · doi:10.1039/b409139f · Cited by 330
A continuous cell separation chip using hydrodynamic dielectrophoresis (DEP) process
Doh, I., & Cho, Y.-H. (2005) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2005.01.030 · Cited by 309
Soft inertial microfluidics for high throughput separation of bacteria from human blood cells
Wu, Z., Willing, B., Bjerketorp, J., Jansson, J. K., & Hjort, K. (2009) · Lab on a Chip · doi:10.1039/b817611f · Cited by 263
Magnetic Cell Separation: Characterization of Magnetophoretic Mobility
McCloskey, K. E., Chalmers, J. J., & Zborowski, M. (2003) · Analytical Chemistry · doi:10.1021/ac034315j · Cited by 259
Microfluidic Mixing via Acoustically Driven Chaotic Advection
Frommelt, T., Kostur, M., Wenzel-Schäfer, M., Talkner, P., Hänggi, P., & Wixforth, A. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.034502 · Cited by 248
Cell-based high content screening using an integrated microfluidic device
Ye, N., Qin, J., Shi, W., Liu, X., & Lin, B. (2007) · Lab on a Chip · doi:10.1039/b711513j · Cited by 246
Surface acoustic wave concentration of particle and bioparticle suspensions
Li, H., Friend, J. R., & Yeo, L. Y. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9058-2 · Cited by 227
Cell microarrays and RNA interference chip away at gene function
Wheeler, D. B., Carpenter, A. E., & Sabatini, D. M. (2005) · Nature Genetics · doi:10.1038/ng1560 · Cited by 226
High-content single-cell drug screening with phosphospecific flow cytometry
Krutzik, P. O., Crane, J. M., Clutter, M. R., & Nolan, G. P. (2008) · Nature Chemical Biology · doi:10.1038/nchembio.2007.59 · Cited by 207
Lara, O., Tong, X., Zborowski, M., & Chalmers, J. J. (2004) · Experimental Hematology · doi:10.1016/j.exphem.2004.07.007 · Cited by 199
Micromagnetic–microfluidic blood cleansing device
Yung, C. W., Fiering, J., Mueller, A. J., & Ingber, D. E. (2009) · Lab on a Chip · doi:10.1039/b816986a · Cited by 196
Microparticle collection and concentration via a miniature surface acoustic wave device
Tan, M. K., Friend, J. R., & Yeo, L. Y. (2007) · Lab on a Chip · doi:10.1039/b618044b · Cited by 191
Hawkins, B. G., Smith, A. E., Syed, Y. A., & Kirby, B. J. (2007) · Analytical Chemistry · doi:10.1021/ac0707277 · Cited by 162
Membrane-free microfiltration by asymmetric inertial migration
Seo, J., Lean, M. H., & Kole, A. (2007) · Applied Physics Letters · doi:10.1063/1.2756272 · Cited by 139
Direct patterning of mammalian cells onto porous tissue engineering substrates using agarose stamps
Stevens, M. M., Mayer, M., Anderson, D. G., Weibel, D. B., Whitesides, G. M., & Langer, R. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.001 · Cited by 134
Abdelgawad, M. O., Watson, M. W. L., & Wheeler, A. R. (2009) · Lab on a Chip · doi:10.1039/b820682a · Cited by 122
Hsiao, V. K. S., Waldeisen, J. R., Zheng, Y., Lloyd, P. F., Bunning, T. J., & Huang, T. J. (2007) · Journal of Materials Chemistry · doi:10.1039/b711200a · Cited by 105
Self-citationSurface Acoustic Wave Devices and Their Signal Processing Applications
Campbell, C., & Burgess, J. C. (1991) · The Journal of the Acoustical Society of America · doi:10.1121/1.400569 · Cited by 100
Separation of particles by pulsed dielectrophoresis
Cui, H., Voldman, J., He, X., et al. (2009) · Lab on a Chip · doi:10.1039/b906202e · Cited by 85
A glass microfluidic chip for continuous blood cell sorting by a magnetic gradient without labeling
Qu, B.-Y., Wu, Z., Fang, F., Bai, Z., Yang, D., & Xu, S.-K. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2382-4 · Cited by 72
Dynamic patterns in a supported lipid bilayer driven by standing surface acoustic waves
Hennig, M., Neumann, J., Wixforth, A., Rädler, J. O., & Schneider, M. F. (2009) · Lab on a Chip · doi:10.1039/b907157a · Cited by 33
Cited by
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Surface acoustic wave microfluidics
Ding, X., Li, P., Lin, S.-C. S., Stratton, Z. S., Nama, N., Guo, F., Slotcavage, D., Mao, X., Shi, J., Costanzo, F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50361e · Cited by 926
Self-citationOn-chip manipulation of single microparticles, cells, and organisms using surface acoustic waves
Ding, X., Lin, S.-C. S., Kiraly, B., Yue, H., Li, S., Chiang, I.-K., Shi, J., Benkovic, S. J., & Huang, T. J. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1209288109 · Cited by 912
Self-citationMicrofluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Surface Acoustic Wave Microfluidics
Yeo, L. Y., & Friend, J. R. (2014) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-010313-141418 · Cited by 561
Metadata
- Authors
- Shi, J., Huang, H., Stratton, Z., Huang, Y., & Huang, T. J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 23
- Pages
- 3354
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2104893368
- Cited by
- 547
- References
- 38
- FWCI
- 14.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.