The DOI matches its Crossref record; 77 of the 77 references it cites were found in a registry or an index.
How useful is ion mobility mass spectrometry for structural biology? The relationship between protein crystal structures and their collision cross sections in the gas phase
Abstract
The technique of ion mobility mass spectrometry (IM-MS) has become of increasing interest for rapid analysis of the conformations adopted by biological macromolecules. It is currently used routinely for analysis of explosives and illegal substances in airport and military security. In biophysical research, it can be used to determine the temperature dependent rotationally averaged collision cross section of gas-phase ions of proteins and nucleic acids along with their mass to charge ratios. Nanoelectrospray ionisation allows the gentle transfer of intact biomolecules from solutions in which the native form(s) are present, into the solvent free environment of a mass spectrometer. It is believed by many researchers that the experimental collision cross sections of these molecules should have some relationship to crystal structure coordinates. In this review we outline the different experimental methods that can be used to measure ion mobility; we also describe methods used to calculate collision cross sections from input coordinates. Following this survey of the methodological approaches to IM-MS, we then summarise IM-MS data published to date for some monomeric peptides and small soluble proteins, along with collision cross sections calculated from their crystal structure coordinates. Finally we consider the relationship between experimental gas-phase conformations and those adopted in crystals and give an outlook on the application of IM-MS as a tool for structural biology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transport Properties of Ions in Gases
Mason, E. A., & McDaniel, E. W. (1988) · Wiley eBooks · doi:10.1002/3527602852 · Cited by 1,797
Structure of ubiquitin refined at 1.8 Å resolution
Vijay-kumar, S., Bugg, C. E., & Cook, W. J. (1987) · Journal of Molecular Biology · doi:10.1016/0022-2836(87)90679-6 · Cited by 1,742
Ion mobility–mass spectrometry
Kanu, A. B., Dwivedi, P., Tam, M., Matz, L., & Hill, H. H. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1383 · Cited by 1,154
Ion mobility–mass spectrometry analysis of large protein complexes
Ruotolo, B. T., Benesch, J. L. P., Sandercock, A. M., Hyung, S.-J., & Robinson, C. V. (2008) · Nature Protocols · doi:10.1038/nprot.2008.78 · Cited by 1,092
High-resolution three-dimensional structure of horse heart cytochrome c
Bushnell, G. W., Louie, G. V., & Brayer, G. D. (1990) · Journal of Molecular Biology · doi:10.1016/0022-2836(90)90200-6 · Cited by 1,056
Structural Information from Ion Mobility Measurements: Effects of the Long-Range Potential
Mesleh, M. F., Hunter, J. M., Shvartsburg, A. A., Schatz, G. C., & Jarrold, M. F. (1996) · The Journal of Physical Chemistry · doi:10.1021/jp961623v · Cited by 1,043
Electron Capture Dissociation for Structural Characterization of Multiply Charged Protein Cations
Zubarev, R. A., Horn, D. M., Fridriksson, E. K., Kelleher, N. L., Kruger, N. A., Lewis, M. A., Carpenter, B. K., & McLafferty, F. W. (2000) · Analytical Chemistry · doi:10.1021/ac990811p · Cited by 986
Bernstein, S. L., Dupuis, N. F., Lazo, N. D., Wyttenbach, T., Condron, M. M., Bitan, G., Teplow, D. B., Shea, J.-E., Ruotolo, B. T., Robinson, C. V., et al. (2009) · Nature Chemistry · doi:10.1038/nchem.247 · Cited by 918
An exact hard-spheres scattering model for the mobilities of polyatomic ions
Shvartsburg, A. A., & Jarrold, M. F. (1996) · Chemical Physics Letters · doi:10.1016/0009-2614(96)00941-4 · Cited by 819
Pringle, S. D., Giles, K., Wildgoose, J. L., Williams, J. P., Slade, S. E., Thalassinos, K., Bateman, R. H., Bowers, M. T., & Scrivens, J. H. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.07.021 · Cited by 808
Kantardjieff, K. A., & Rupp, B. (2003) · Protein Science · doi:10.1110/ps.0350503 · Cited by 758
Inhomogeneous RF Fields: A Versatile Tool for the Study of Processes with Slow Ions
Gerlich, D. (1992) · Advances in Chemical Physics · doi:10.1002/9780470141397.ch1 · Cited by 685
Solution structure of calcium-free calmodulin
Kuboniwa, H., Tjandra, N., Grzesiek, S., Ren, H., Klee, C. B., & Bax, A. (1995) · Nature Structural & Molecular Biology · doi:10.1038/nsb0995-768 · Cited by 660
Evidence for Macromolecular Protein Rings in the Absence of Bulk Water
Ruotolo, B. T., Giles, K., Campuzano, I., Sandercock, A. M., Bateman, R. H., & Robinson, C. V. (2005) · Science · doi:10.1126/science.1120177 · Cited by 596
Fundamentals of Traveling Wave Ion Mobility Spectrometry
Shvartsburg, A. A., & Smith, R. D. (2008) · Analytical Chemistry · doi:10.1021/ac8016295 · Cited by 534
Naked Protein Conformations: Cytochrome c in the Gas Phase
Clemmer, D. E., Hudgins, R. R., & Jarrold, M. F. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00145a037 · Cited by 491
Ion mobility mass spectrometry of proteins and proteinassemblies
Uetrecht, C., Rose, R. J., van Duijn, E., Lorenzen, K., & Heck, A. J. R. (2010) · Chem. Soc. Rev. · doi:10.1039/b914002f · Cited by 462
Buryakov, I. A., Krylov, E. V., Nazarov, E. G., & Rasulev, U. K. (1993) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(93)87062-w · Cited by 444
Breuker, K., & McLafferty, F. W. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0807005105 · Cited by 423
Protein Structure in Vacuo: Gas-Phase Conformations of BPTI and Cytochrome c
Shelimov, K. B., Clemmer, D. E., Hudgins, R. R., & Jarrold, M. F. (1997) · Journal of the American Chemical Society · doi:10.1021/ja9619059 · Cited by 414
Protein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 408
Three-Dimensional Ion Mobility/TOFMS Analysis of Electrosprayed Biomolecules
Hoaglund, C. S., Valentine, S. J., Sporleder, C. R., Reilly, J. P., & Clemmer, D. E. (1998) · Analytical Chemistry · doi:10.1021/ac980059c · Cited by 345
Amyloid β-Protein: Monomer Structure and Early Aggregation States of Aβ42 and Its Pro19Alloform
Bernstein, S. L., Wyttenbach, T., Baumketner, A., Shea, J.-E., Bitan, G., Teplow, D. B., & Bowers, M. T. (2005) · Journal of the American Chemical Society · doi:10.1021/ja044531p · Cited by 341
Crystal Structures of CO−, Deoxy- and Met-myoglobins at Various pH Values
Yang, F., & Phillips Jr, G. N. (1996) · Journal of Molecular Biology · doi:10.1006/jmbi.1996.0123 · Cited by 339
Smith, D. P., Knapman, T. W., Campuzano, I., Malham, R. W., Berryman, J. T., Radford, S. E., & Ashcroft, A. E. (2009) · European Journal of Mass Spectrometry · doi:10.1255/ejms.947 · Cited by 334
Effect of the long-range potential on ion mobility measurements
Wyttenbach, T., von Helden, G., Batka, J. J., Carlat, D., & Bowers, M. T. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(96)00236-x · Cited by 332
The Structure of Human β-Defensin-2 Shows Evidence of Higher Order Oligomerization
Hoover, D. M., Rajashankar, K. R., Blumenthal, R., Puri, A., Oppenheim, J. J., Chertov, O., & Lubkowski, J. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.m006098200 · Cited by 321
Schröder, D., Schwarz, H., Clemmer, D. E., Chen, Y., Armentrout, P. B., Baranov, V. I., & Böhme, D. K. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(96)04428-x · Cited by 311
High-resolution ion mobility measurements
Dugourd, P., Hudgins, R. R., Clemmer, D. E., & Jarrold, M. F. (1997) · Review of Scientific Instruments · doi:10.1063/1.1147873 · Cited by 299
Annales de chimie et de physique
Damien, B.-C. (1888) · Journal de Physique Théorique et Appliquée · doi:10.1051/jphystap:018880070038100 · Cited by 293
Design of a new electrospray ion mobility mass spectrometer
Wyttenbach, T., Kemper, P. R., & Bowers, M. T. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(01)00517-6 · Cited by 277
Mass spectrometric characterization of a high-field asymmetric waveform ion mobility spectrometer
Purves, R. W., Guevremont, R., Day, S., Pipich, C. W., & Matyjaszczyk, M. S. (1998) · Review of Scientific Instruments · doi:10.1063/1.1149255 · Cited by 265
Amyloid β‐protein monomer structure: A computational and experimental study
Baumketner, A., Bernstein, S. L., Wyttenbach, T., Bitan, G., Teplow, D. B., Bowers, M. T., & Shea, J. (2006) · Protein Science · doi:10.1110/ps.051762406 · Cited by 247
Valentine, S. J., Anderson, J. G., Ellington, A. D., & Clemmer, D. E. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp970217o · Cited by 234
Conformer-dependent proton-transfer reactions of ubiquitin ions
Valentine, S. J., Counterman, A. E., & Clemmer, D. E. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00085-8 · Cited by 230
Ruotolo, B. T., Hyung, S., Robinson, P. M., Giles, K., Bateman, R. H., & Robinson, C. V. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200702161 · Cited by 229
Electrospray Ionization Ion Mobility Spectrometry
Wittmer, D., Chen, Y. H., Luckenbill, B. K., & Hill, H. H. (1994) · Analytical Chemistry · doi:10.1021/ac00086a021 · Cited by 216
Profiling and imaging of tissues by imaging ion mobility‐mass spectrometry
McLean, J. A., Ridenour, W. B., & Caprioli, R. M. (2007) · Journal of Mass Spectrometry · doi:10.1002/jms.1254 · Cited by 209
Drift Tube Studies of Atomic Clusters
Jarrold, M. F. (1995) · The Journal of Physical Chemistry · doi:10.1021/j100001a004 · Cited by 208
IMS−IMS and IMS−IMS−IMS/MS for Separating Peptide and Protein Fragment Ions
Merenbloom, S. I., Koeniger, S. L., Valentine, S. J., Plasencia, M. D., & Clemmer, D. E. (2006) · Analytical Chemistry · doi:10.1021/ac052208e · Cited by 200
Structure of form III crystals of bovine pancreatic trypsin inhibitor
Wlodawer, A., Nachman, J., Gilliland, G. L., Gallagher, W., & Woodward, C. (1987) · Journal of Molecular Biology · doi:10.1016/0022-2836(87)90294-4 · Cited by 200
Crystal Structure of T State Haemoglobin with Oxygen Bound At All Four Haems
Paoli, M., Liddington, R., Tame, J., Wilkinson, A., & Dodson, G. (1996) · Journal of Molecular Biology · doi:10.1006/jmbi.1996.0124 · Cited by 198
Hopper, J. T. S., & Oldham, N. J. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.06.010 · Cited by 197
A new, higher resolution, ion mobility mass spectrometer
Kemper, P. R., Dupuis, N. F., & Bowers, M. T. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.01.012 · Cited by 195
Crystal structure of monomeric human β-2-microglobulin reveals clues to its amyloidogenic properties
Trinh, C. H., Smith, D. P., Kalverda, A. P., Phillips, S. E. V., & Radford, S. E. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.152337399 · Cited by 180
Salt Bridge Structures in the Absence of Solvent? The Case for the Oligoglycines
Wyttenbach, T., Bushnell, J. E., & Bowers, M. T. (1998) · Journal of the American Chemical Society · doi:10.1021/ja9801238 · Cited by 176
AVERAGE CROSS-SECTIONAL AREAS OF MOLECULES BY GASEOUS DIFFUSION METHODS
Mack, E. (1925) · Journal of the American Chemical Society · doi:10.1021/ja01687a007 · Cited by 166
Smith, D. P., Radford, S. E., & Ashcroft, A. E. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0913046107 · Cited by 155
α-Synuclein: Stable compact and extended monomeric structures and pH dependence of dimer formation
Bernstein, S. L., Liu, D., Wyttenbach, T., Bowers, M. T., Lee, J. C., Gray, H. B., & Winkler, J. R. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.08.003 · Cited by 154
Chaperonin Complexes Monitored by Ion Mobility Mass Spectrometry
van Duijn, E., Barendregt, A., Synowsky, S. A., Versluis, C., & Heck, A. J. R. (2009) · Journal of the American Chemical Society · doi:10.1021/ja8055134 · Cited by 152
Valentine, S. J., Kulchania, M., Barnes, C. A. S., & Clemmer, D. E. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(01)00511-5 · Cited by 143
Mobilities of carbon cluster ions: Critical importance of the molecular attractive potential
Shvartsburg, A. A., Schatz, G. C., & Jarrold, M. F. (1998) · The Journal of Chemical Physics · doi:10.1063/1.475625 · Cited by 142
Two-Dimensional Gas-Phase Separations Coupled to Mass Spectrometry for Analysis of Complex Mixtures
Tang, K., Li, F., Shvartsburg, A. A., Strittmatter, E. F., & Smith, R. D. (2005) · Analytical Chemistry · doi:10.1021/ac050871x · Cited by 141
Gidden, J. A., Ferzoco, A., Baker, E. S., & Bowers, M. T. (2004) · Journal of the American Chemical Society · doi:10.1021/ja046433+ · Cited by 118
An Ion Trap Interface for ESI−Ion Mobility Experiments
Hoaglund‐Hyzer, C. S., Valentine, S. J., & Clemmer, D. E. (1997) · Analytical Chemistry · doi:10.1021/ac970526a · Cited by 117
Myung, S., Lee, Y., Moon, M. H., Taraszka, J. A., Robinson, R. A. S., Koeniger, S. L., Hilderbrand, A. E., Valentine, S. J., Cherbas, L., Cherbas, P. T., et al. (2003) · Analytical Chemistry · doi:10.1021/ac030107f · Cited by 113
Drift Tube-Mass Spectrometer for Studies of Low-Energy Ion-Molecule Reactions
McDaniel, E. W., Martin, D. W., & Barnes, W. S. (1962) · Review of Scientific Instruments · doi:10.1063/1.1717656 · Cited by 111
Stability and Shape of Hepatitis B Virus Capsids In Vacuo
Uetrecht, C., Versluis, C., Watts, N. R. M., Wingfield, P. T., Steven, A. C., & Heck, A. J. R. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200802410 · Cited by 108
Optimization of Algorithms for Ion Mobility Calculations
Shvartsburg, A. A., Mashkevich, S. V., Baker, E. S., & Smith, R. D. (2007) · The Journal of Physical Chemistry A · doi:10.1021/jp066953m · Cited by 102
Volumes of Individual Amino Acid Residues in Gas-Phase Peptide Ions
Counterman, A. E., & Clemmer, D. E. (1999) · Journal of the American Chemical Society · doi:10.1021/ja984344p · Cited by 90
PNA/dsDNA Complexes: Site Specific Binding and dsDNA Biosensor Applications
Baker, E. S., Hong, J. W., Gaylord, B. S., Bazan, G. C., & Bowers, M. T. (2006) · Journal of the American Chemical Society · doi:10.1021/ja060069s · Cited by 85
Temperature-dependent H/D exchange of compact and elongated cytochrome c ions in the gas phase
Valentine, S. J., & Clemmer, D. E. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00372-0 · Cited by 82
Weiss, M. S., Palm, G., & Hilgenfeld, R. (2000) · Acta Crystallographica Section D: Biological Crystallography · doi:10.1107/s0907444900006685 · Cited by 82
Development of an Ion Mobility Quadrupole Time of Flight Mass Spectrometer
McCullough, B. J., Kalapothakis, J. M. D., Eastwood, H., Kemper, P. R., Macmillan, D., Taylor, K. J., Dorin, J. R., & Barran, P. E. (2008) · Analytical Chemistry · doi:10.1021/ac800651b · Cited by 81
Self-citationXuan, Y., Creese, A. J., Horner, J. A., & Cooper, H. J. (2009) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4101 · Cited by 78
A Split-Field Drift Tube for Separation and Efficient Fragmentation of Biomolecular Ions
Valentine, S. J., Koeniger, S. L., & Clemmer, D. E. (2003) · Analytical Chemistry · doi:10.1021/ac030111r · Cited by 75
Probing hemoglobin structure by means of traveling-wave ion mobility mass spectrometry
Scarff, C. A., Patel, V. J., Thalassinos, K., et al. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.11.023 · Cited by 75
Taraszka, J. A., Kurulugama, R. T., Robinson, R. A. S., Valentine, S. J., Koeniger, S. L., Arnold, R. J., Miller, D. F., Kaufman, T. C., & Clemmer, D. E. (2005) · Journal of Proteome Research · doi:10.1021/pr050038g · Cited by 67
Wyttenbach, T., Grabenauer, M., Thalassinos, K., Scrivens, J. H., & Bowers, M. T. (2009) · The Journal of Physical Chemistry B · doi:10.1021/jp906242m · Cited by 64
Leary, J. A., Schenauer, M. R., Ştefănescu, R., Andaya, A., Ruotolo, B. T., Robinson, C. V., Thalassinos, K., Scrivens, J. H., Sokabe, M., & Hershey, J. W. B. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.05.003 · Cited by 57
Protein Expression in a Drosophila Model of Parkinson's Disease
Xun, Z., Robinson, R. A. S., Kaufman, T. C., & Clemmer, D. E. (2006) · Journal of Proteome Research · doi:10.1021/pr060488o · Cited by 57
Gas-phase metalloprotein complexes interrogated by ion mobility-mass spectrometry
Faull, P. A., Korkeila, K. E., Kalapothakis, J. M. D., Gray, A., McCullough, B. J., & Barran, P. E. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.02.024 · Cited by 56
Self-citationNanoflow LC/Ion Mobility/CID/TOF for Proteomics: Analysis of a Human Urinary Proteome
Moon, M. H., Myung, S., Plasencia, M. D., et al. (2003) · Journal of Proteome Research · doi:10.1021/pr034018v · Cited by 53
Borysik, A. J., Read, P., Little, D. R., Bateman, R. H., Radford, S. E., & Ashcroft, A. E. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1613 · Cited by 53
Shvartsburg, A. A., Noskov, S. Y., Purves, R. W., & Smith, R. D. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0812318106 · Cited by 46
Evolution of Constrained Gonadotropin-releasing Hormone Ligand Conformation and Receptor Selectivity
Barran, P. E., Roeske, R. W., Pawson, A. J., Sellar, R., Bowers, M. T., Morgan, K., Lu, Z.-L., Tsuda, M., Kusakabe, T. G., & Millar, R. P. (2005) · Journal of Biological Chemistry · doi:10.1074/jbc.m503086200 · Cited by 43
Self-citationSpontaneous dimensional reduction in Kaluza-Klein theories
Tosa, Y. (1984) · Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields · doi:10.1103/physrevd.30.339 · Cited by 17
Cited by
Lanucara, F., Holman, S. W., Gray, C. J., & Eyers, C. E. (2014) · Nature Chemistry · doi:10.1038/nchem.1889 · Cited by 901
Native Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602
“Perhaps even more convincing arguments that protein structures can be partly retained in the gas phase come from more recent ion mobility spectrometry (IMS) experiments [62, 63].”
BackgroundIon Mobility Spectrometry: Fundamental Concepts, Instrumentation, Applications, and the Road Ahead
Dodds, J. N., & Baker, E. S. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02288-2 · Cited by 574
Stow, S. M., Causon, T. J., Zheng, X., Kurulugama, R. T., Mairinger, T., May, J. C., Rennie, E. E., Baker, E. S., Smith, R. D., McLean, J. A., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01729 · Cited by 534
A Cyclic Ion Mobility-Mass Spectrometry System
Giles, K., Ujma, J., Wildgoose, J., Pringle, S., Richardson, K., Langridge, D., & Green, M. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01838 · Cited by 510
Metadata
- Authors
- Jurneczko, E., & Barran, P. E.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 136
- Issue
- 1
- Pages
- 20-28
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2018871138
- Cited by
- 328
- References
- 77
- FWCI
- 7.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.