Gut-on-a-Chip microenvironment induces human intestinal cells to undergo villus differentiation
The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Abstract
Existing in vitro models of human intestinal function commonly rely on use of established epithelial cell lines, such as Caco-2 cells, which form polarized epithelial monolayers but fail to mimic more complex intestinal functions that are required for drug development and disease research. We show here that a microfluidic 'Gut-on-a-Chip' technology that exposes cultured cells to physiological peristalsis-like motions and liquid flow can be used to induce human Caco-2 cells to spontaneously undergo robust morphogenesis of three-dimensional (3D) intestinal villi. The cells of that line these villus structures are linked by tight junctions, and covered by brush borders and mucus. They also reconstitute basal proliferative crypts that populate the villi along the crypt-villus axis, and form four different types of differentiated epithelial cells (absorptive, mucus-secretory, enteroendocrine, and Paneth) that take characteristic positions similar to those observed in living human small intestine. Formation of these intestinal villi also results in exposure of increased intestinal surface area that mimics the absorptive efficiency of human intestine, as well enhanced cytochrome P450 3A4 isoform-based drug metabolizing activity compared to conventional Caco-2 cell monolayers cultured in a static Transwell system. The ability of the human Gut-on-a-Chip to recapitulate the 3D structures, differentiated cell types, and multiple physiological functions of normal human intestinal villi may provide a powerful alternative in vitro model for studies on intestinal physiology and digestive diseases, as well as drug development.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“this 2-dimensional (2D) culture format fails to recapitulate physiological 3-dimensional (3D) intestinal cell and tissue morphology or re-establish other key intestinal differentiated functions (eg, mucus production, villi formation, cytochrome P-450-based drug metabolism).”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [17]
In the citing paper
“Under these physiological conditions, human Caco-2 intestinal epithelial cells, which characteristically grow as flattened cells within a planar monolayer in conventional 2-dimensional cultures, spontaneously undergo villus morphogenesis inside this mechanically dynamic Gut Chip (Figure 1B).17”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [17]
In the citing paper
“The microengineered villi are lined by all 4 lineages of differentiated small intestinal cells (absorptive, goblet, enteroendocrine, and Paneth), which exhibit columnar cell morphology similar to that observed in the living intestine.17”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [17]
In the citing paper
“Intestinal villus morphogenesis on-chip is also accompanied by establishment of a crypt-villus axis, including restriction of proliferative cells to the basal crypts and their upward migration, drug metabolizing activity, mucus production, and glucose reuptake.17”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [17]
In the citing paper
“One potential limitation of this model system is that the Caco-2 intestinal epithelial cells were originally isolated from a human colorectal tumor, although they were subsequently shown to exhibit features more similar to human small intestine (12,16,34).”
From Contributions of microbiome and mechanical deformation to intestinal bacterial overgrowth and inflammation in a human gut-on-a-chip (2016) · cites this paper as [16]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
NIH Image to ImageJ: 25 years of image analysis
Schneider, C. A., Rasband, W. S., & Eliceiri, K. W. (2012) · Nature Methods · doi:10.1038/nmeth.2089 · Cited by 64,638
Turnbaugh, P. J., Ley, R. E., Hamady, M., Fraser-Liggett, C. M., Knight, R., & Gordon, J. I. (2007) · Nature · doi:10.1038/nature06244 · Cited by 6,091
Wnt signalling in stem cells and cancer
Reya, T., & Clevers, H. (2005) · Nature · doi:10.1038/nature03319 · Cited by 3,666
Membrane transporters in drug development
The International Transporter Consortium, Giacomini, K. M., Huang, S.-M., Tweedie, D. J., Benet, L. Z., Brouwer, K. L. R., Chu, X., Dahlin, A., Evers, R., Fischer, V., et al. (2010) · Nature Reviews Drug Discovery · doi:10.1038/nrd3028 · Cited by 3,340
Genomic responses in mouse models poorly mimic human inflammatory diseases
Seok, J., Warren, H. S., Cuenca, A. G., Mindrinos, M. N., Baker, H. V., Xu, W., Richards, D. R., McDonald-Smith, G. P., Gao, H., Hennessy, L., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1222878110 · Cited by 3,005
Paneth cells constitute the niche for Lgr5 stem cells in intestinal crypts
Sato, T., van Es, J. H., Snippert, H. J., Stange, D. E., Vries, R. G., van den Born, M., Barker, N., Shroyer, N. F., van de Wetering, M., & Clevers, H. (2011) · Nature · doi:10.1038/nature09637 · Cited by 2,510
Hidalgo, I. J., Raub, T. J., & Borchardt, R. T. (1989) · Gastroenterology · doi:10.1016/s0016-5085(89)80072-1 · Cited by 2,396
Concordance of the toxicity of pharmaceuticals in humans and in animals
Olson, H., Betton, G., Robinson, D., Thomas, K., Monro, A., Kolaja, G., Lilly, P., Sanders, J., Sipes, G., Bracken, W., et al. (2000) · Regulatory Toxicology and Pharmacology · doi:10.1006/rtph.2000.1399 · Cited by 2,050
Stem Cells, Self-Renewal, and Differentiation in the Intestinal Epithelium
van der Flier, L. G., & Clevers, H. (2009) · Annual Review of Physiology · doi:10.1146/annurev.physiol.010908.163145 · Cited by 1,871
A chemical method for fast and sensitive detection of DNA synthesis in vivo
Salic, A., & Mitchison, T. J. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0712168105 · Cited by 1,861
Research works printed but not linked: 3
- Chantret, 1988, Cancer Res., 48, 1936
- Traber, 1992, Am. J. Physiol., 262, G123
- Lewin, 1969, Ann. R. Coll. Surg. Engl., 44, 23
Cited by
Items 101–200 of 749
Gnecco, J. S., Pensabene, V., Li, D. J., Ding, T., Hui, E. E., Bruner-Tran, K. L., & Osteen, K. G. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1797-5 · Cited by 110
Biomechanical Strain Exacerbates Inflammation on a Progeria‐on‐a‐Chip Model
Ribas, J., Zhang, Y. S., Pitrez, P. R., Leijten, J., Miscuglio, M., Rouwkema, J., Dokmeci, M. R., Nissan, X., Ferreira, L., & Khademhosseini, A. (2017) · Small · doi:10.1002/smll.201603737 · Cited by 111
Laurent, F., & Lacroix‐Lamandé, S. (2017) · International Journal for Parasitology · doi:10.1016/j.ijpara.2017.08.001 · Cited by 129
“DOI : 10.1016/j.ijpara.2017.08.001 10 to spontaneously undergo robust morphogenesis of 3D intestinal villi (Huh et al., 2013; Kim and Ingber, 2013).”
BackgroundInfluentialPocock, K., Delon, L., Bala, V., Rao, S., Priest, C., Prestidge, C., & Thierry, B. (2017) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.7b00023 · Cited by 111
Kohl, Y., Rundén‐Pran, E., Mariussen, E., Hesler, M., Yamani, N. E., Longhin, E., & Dušinská, M. (2020) · Nanomaterials · doi:10.3390/nano10101911 · Cited by 123
Yang, J., Hirai, Y., Iida, K., Ito, S., Trumm, M., Terada, S., Sakai, R., Tsuchiya, T., Tabata, O., & Kamei, K.-I. (2020) · doi:10.1101/2020.06.10.141606 · Cited by 110
Fowler, S., Chen, W. L. K., Duignan, D. B., Gupta, A., Hariparsad, N., Kenny, J. R., Lai, W. G., Liras, J., Phillips, J. A., & Gan, J. (2020) · Lab on a Chip · doi:10.1039/c9lc00857h · Cited by 109
Organ-on-a-chip platforms for accelerating the evaluation of nanomedicine
Chen, X., Zhang, Y. S., Zhang, X., & Liu, C. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.09.022 · Cited by 107
“lung [68,69], liver [70,71], blood vessel [72,73], gut [74,75], heart [76,77], uterus [78,79], brain [80–82], bone marrow [83,84], and tumor/cancer [85,86], as illustrated in Scheme 1.”
BackgroundKim, S. H., Chi, M., Yi, B., Ys, K., Oh, S., Kim, Y., Park, S., & Sung, J. H. (2014) · Integrative Biology · doi:10.1039/c4ib00157e · Cited by 113
Chen, Y., Zhou, W., Roh, T., Estes, M. K., & Kaplan, D. L. (2017) · PLOS ONE · doi:10.1371/journal.pone.0187880 · Cited by 105
Organ-on-a-chip engineering: Toward bridging the gap between lab and industry
Ramadan, Q., & Zourob, M. M. (2020) · Biomicrofluidics · doi:10.1063/5.0011583 · Cited by 113
MCF-7 Human Breast Cancer Cells Form Differentiated Microtissues in Scaffold-Free Hydrogels
Vantangoli, M. M., Madnick, S. J., Huse, S. M., Weston, P. J., & Boekelheide, K. (2015) · PLoS ONE · doi:10.1371/journal.pone.0135426 · Cited by 128
A Polymer Chemistry Point of View on Mucoadhesion and Mucopenetration
Schattling, P., Taipaleenmäki, E., Zhang, Y., & Städler, B. (2017) · Macromolecular Bioscience · doi:10.1002/mabi.201700060 · Cited by 106
Flat and microstructured polymeric membranes in organs-on-chips
Pasman, T., Grijpma, D., Stamatialis, D., & Poot, A. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2018.0351 · Cited by 98
“Because of the need of such in vitro models, OOCs have been developed (1-48).”
BackgroundMethodInfluentialThe Role of Microfluidics for Organ on Chip Simulations
Aziz, A. U. R., Geng, C., Fu, M., Yu, X., Qin, K., & Liu, B. (2017) · Bioengineering · doi:10.3390/bioengineering4020039 · Cited by 115
The Use of Defined Microbial Communities To Model Host-Microbe Interactions in the Human Gut
Elzinga, J., John van der, O. O. S. T., de Vos, W. M., & Smidt, H. (2019) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.00054-18 · Cited by 111
The Gut–Organ-Axis Concept: Advances the Application of Gut-on-Chip Technology
Guo, Y., Chen, X., Gong, P., Li, G., Yao, W., & Yang, W. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24044089 · Cited by 115
“Under these physiological conditions, human Caco-2 intestinal epithelial cells undergo spontaneous villi morphogenesis in this mechanically dynamic intestinal microarray, unlike conventional two-dimensional cultures where cells are grown as a planar monolayer [63].”
BackgroundIntestinal organoids: A new paradigm for engineering intestinal epithelium in vitro
Rahmani, S., Breyner, N. M., Su, H.-M., Verdu, E. F., & Didar, T. F. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.12.006 · Cited by 98
The emergence of 3D bioprinting in organ-on-chip systems
Fetah, K., Tebon, P., Goudie, M. J., Eichenbaum, J., Ren, L., Barros, N., Nasiri, R., Ahadian, S., Ashammakhi, N., Dokmeci, M. R., et al. (2019) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab23df · Cited by 98
“A 2013 study by Kim et al demonstrated the ability to induce the morphogenesis of Caco-2 cells into villus structures by stimulating luminal flow [190].”
BackgroundYang, J., Hirai, Y., Iida, K., Ito, S., Trumm, M., Terada, S., Sakai, R., Tsuchiya, T., Tabata, O., & Kamei, K.-I. (2023) · Communications Biology · doi:10.1038/s42003-023-04710-8 · Cited by 98
The Past, Present and Future of Intestinal In Vitro Cell Systems for Drug Absorption Studies
Youhanna, S. C., & Lauschke, V. M. (2020) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2020.07.001 · Cited by 116
Organs-on-chip monitoring: sensors and other strategies
Kilic, T., Navaee, F., Stradolini, F., Renaud, P., & Carrara, S. (2018) · Microphysiological Systems · doi:10.21037/mps.2018.01.01 · Cited by 96
“Similar technology has also been used for the design of gut-on-a-chip to mimic the trickling fluid flow as well as cyclic peristaltic motions that a gut experiences in vivo (4).”
BackgroundMethodInfluentialIncorporating mechanical strain in organs-on-a-chip: Lung and skin
Guenat, O. T., & Berthiaume, F. (2018) · Biomicrofluidics · doi:10.1063/1.5024895 · Cited by 108
Recent advances in microfluidic 3D cellular scaffolds for drug assays
Wu, J., Chen, Q., Liu, W., He, Z., & Lin, J. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.11.009 · Cited by 99
Organ-on-Chip Approaches for Intestinal 3D In Vitro Modeling
Pimenta, J. M., Ribeiro, R. D. C., Almeida, R., Costa, P. F., da Silva, M. A., & Pereira, B. (2021) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2021.08.015 · Cited by 101
“The 5ethynyl-20-deoxyuridine pulse-chase experiments showed that proliferative activity was restricted to the basal regions between adjacent villi and labeled cells migrated upward, suggesting that undifferentiated cells remain in the cryptlike niche and generate daughter cells that become more differentiated along th…”
BackgroundOrally ingestible medical devices for gut engineering
Mandsberg, N. K., Christfort, J. F., Kamguyan, K., Boisen, A., & Srivastava, S. K. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.05.004 · Cited by 95
“3C i-ii) [41].”
Laminar ventricular myocardium on a microelectrode array-based chip
Kujala, V. J., Pasqualini, F. S., Goss, J. A., Nawroth, J. C., & Parker, K. K. (2016) · Journal of Materials Chemistry B · doi:10.1039/c6tb00324a · Cited by 91
Vaessen, S. F. C., van Lipzig, M. M. H., Pieters, R. H. H., Krul, C. A. M., Wortelboer, H. M., & van de Steeg, E. (2017) · Drug Metabolism and Disposition · doi:10.1124/dmd.116.072231 · Cited by 100
“Transwell membranes under static conditions (Kim and Ingber, 2013)”
Polymeric and biological membranes for organ-on-a-chip devices
Corral-Nájera, K., Chauhan, G., Serna-Saldivar, S. O., Martinez-Chapa, S. O., & Aeinehvand, M. M. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00579-z · Cited by 106
“Today, Transwells ® are the gold standard for epithelial transport due to their robustness and reproducibility 147 and are considered a baseline for comparison with micro fl uidic devices with similar basal ‒ apical conformations 27,116,136,148 .”
BackgroundOral mucosa-on-a-chip to assess layer-specific responses to bacteria and dental materials
Rahimi, C., Rahimi, B., Padova, D., Rooholghodos, S. A., Bienek, D. R., Luo, X., Kaufman, G., & Raub, C. B. (2018) · Biomicrofluidics · doi:10.1063/1.5048938 · Cited by 94
Shin, Y. C., Shin, W., Koh, D., Wu, A., Ambrosini, Y. M., Min, S., Eckhardt, S., Fleming, R., Kim, S., Park, S., et al. (2020) · Micromachines · doi:10.3390/mi11070663 · Cited by 93
Contributions of the microbiome to intestinal inflammation in a gut-on-a-chip
Jeon, M. S., Choi, Y. Y., Mo, S. J., Ha, J. H., Lee, Y. S., Lee, H. U., Park, S. D., Shim, J.-J., Lee, J.-L., & Chung, B. G. (2022) · Nano Convergence · doi:10.1186/s40580-022-00299-6 · Cited by 92
Organoid-based Models to Study the Role of Host-microbiota Interactions in IBD
Poletti, M., Arnauts, K., Ferrante, M., & Korcsmáros, T. (2020) · Journal of Crohn s and Colitis · doi:10.1093/ecco-jcc/jjaa257 · Cited by 110
Organ-on-chip models for infectious disease research
Alonso‐Román, R., Mosig, A. S., Figge, M. T., Papenfort, K., Eggeling, C., Schacher, F. H., Hube, B., & Gresnigt, M. S. (2024) · Nature Microbiology · doi:10.1038/s41564-024-01645-6 · Cited by 101
“…from the intestinal lumen), mucus-secretory (which produce the mucus layer that covers the intestine), enteroendocrine (which secrete hormones to regulate digestion and nutrient intake), and Paneth cells (which produce antimicrobial peptides and other molecules involved in immunity) 34,35 .”
Oral uptake of nanoparticles: human relevance and the role of in vitro systems
Fröhlich, E., & Roblegg, E. (2016) · Archives of Toxicology · doi:10.1007/s00204-016-1765-0 · Cited by 98
“In contrast to Caco-2 cells, which only in an appropriate 3D environment (gut-on-a-chip; Kim and Ingber 2013) produce mucus, T84 cells are mucus producing, but only few microvilli possessing cells (Donato et al.”
BackgroundResultKim, W.-J., & Kim, G. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b17410 · Cited by 90
Microphysiological Systems: Design, Fabrication, and Applications
Wang, K., Man, K., Liu, J., Liu, Y., Chen, Q., Zhou, Y., & Yang, Y. S. (2020) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.9b01667 · Cited by 90
Engineering and monitoring cellular barrier models
Yeste, J., Illa, X., Álvarez, M., & Villa, R. (2018) · Journal of Biological Engineering · doi:10.1186/s13036-018-0108-5 · Cited by 100
“Interestingly, the application of mechanical cues—fluid flow and mechanical deformation as in gut peristalsis—spontaneously undergoes the formation of villi and crypts, including a higher glucose uptake rate compared to cells cultured in a Transwell insert and differentiation of Caco-2 cells into four different cell t…”
BackgroundFu, Y., Jiao, H., Sun, J., Okoye, C. O., Zhang, H., Li, Y., Lu, X., Wang, Q., & Liu, J. (2023) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2023.121533 · Cited by 97
Intestinal organ chips for disease modelling and personalized medicine
Özkan, A., LoGrande, N., Feitor, J. F., Goyal, G., & Ingber, D. E. (2024) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-024-00968-3 · Cited by 110
“…a highly differentiated villus epithelium lined by all four cell lineages of the small intestine (absorptive, enteroendocrine, mucus-secretory and Paneth cells) and this feature was accomplished even though the culture medium was the same one as was used to culture this cell line in the past 16 .”
InfluentialMimicking Epithelial Tissues in Three-Dimensional Cell Culture Models
Torras, N., García-Díaz, M., Fernández‐Majada, V., & Martínez, E. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00197 · Cited by 99
“Using a similar design, intestinal peristaltic movements could be mimicked with a gut-on-a-chip platform (Kim et al., 2012, 2015; Kim and Ingber, 2013).”
MethodFrom Microscale Devices to 3D Printing: Advances in Fabrication of 3D Cardiovascular Tissues
Borovjagin, A. V., Ogle, B. M., Berry, J. L., & Zhang, J. J. (2017) · Circulation Research · doi:10.1161/circresaha.116.308538 · Cited by 93
Recent lab‐on‐chip developments for novel drug discovery
Khalid, N., Kobayashi, I., & Nakajima, M. (2017) · WIREs Systems Biology and Medicine · doi:10.1002/wsbm.1381 · Cited by 83
A Biomimetic Human Gut‐on‐a‐Chip for Modeling Drug Metabolism in Intestine
Guo, Y., Li, Z., Su, W., Wang, L., Zhu, Y., & Qin, J. (2018) · Artificial Organs · doi:10.1111/aor.13163 · Cited by 88
Achberger, K., Haderspeck, J. C., Kleger, A., & Liebau, S. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.05.005 · Cited by 75
Microphysiological Systems to Recapitulate the Gut–Kidney Axis
Giordano, L., Mihaila, S. M., Amirabadi, H. E., & Masereeuw, R. (2021) · Trends in biotechnology · doi:10.1016/j.tibtech.2020.12.001 · Cited by 87
Fois, C. A. M., Schindeler, A., Valtchev, P., & Dehghani, F. (2021) · Biomedical Microdevices · doi:10.1007/s10544-021-00591-y · Cited by 82
Organs-on-chips: research and commercial perspectives
Balijepalli, A., & Sivaramakrishan, V. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.11.009 · Cited by 89
Bein, A., Fadel, C. W., Swenor, B., Cao, W., Powers, R. K., Camacho, D. M., Naziripour, A., Parsons, A., LoGrande, N., Sanjay, S. T., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00899-x · Cited by 83
Integration of Extracellular Matrices into Organ‐on‐Chip Systems
Kutluk, H., Bastounis, E. E., & Constantinou, I. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202203256 · Cited by 84
Chi, M., Yi, B., Oh, S., Park, D.-J., Sung, J. H., & Park, S. (2015) · Biomedical Microdevices · doi:10.1007/s10544-015-9966-5 · Cited by 88
Kim, W.-J., & Kim, G. (2020) · Theranostics · doi:10.7150/thno.41225 · Cited by 86
Multi-Compartment 3D-Cultured Organ-on-a-Chip: Towards a Biomimetic Lymph Node for Drug Development
Shanti, A., Samara, B., Abdullah, A., Hallfors, N., Accoto, D., Sapudom, J., Alatoom, A., Teo, J. C. M., Danti, S., & Stefanini, C. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12050464 · Cited by 83
Human Microphysiological Models of Intestinal Tissue and Gut Microbiome
Steinway, S. N., Saleh, J., Koo, B., Delacour, D., & Kim, D. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00725 · Cited by 84
“Limitations of this model include physical separation of intestinal and microbial cells by a thin membrane and lack of pulsatile flow (Kim and Ingber, 2013).”
Nelson, M., Charbonneau, M. R., Coia, H. G., Castillo, M. J., Holt, C., Greenwood, E. S., Robinson, P. J., Merrill, E. A., Lubkowicz, D., & Mauzy, C. A. (2021) · Nature Communications · doi:10.1038/s41467-021-23072-5 · Cited by 85
Mechano-Transduction: From Molecules to Tissues
Pruitt, B. L., Dunn, A. R., Weis, W. I., & Nelson, W. J. (2014) · PLoS Biology · doi:10.1371/journal.pbio.1001996 · Cited by 92
Integration Concepts for Multi-Organ Chips: How to Maintain Flexibility?!
Rogal, J., Probst, C., & Loskill, P. (2017) · Future Science OA · doi:10.4155/fsoa-2016-0092 · Cited by 86
Kulthong, K., Duivenvoorde, L. P. M., Sun, H., Confederat, S., Wu, J., Spenkelink, B., de Haan, L., Marin, V., van der Zande, M., & Bouwmeester, H. (2020) · Toxicology in Vitro · doi:10.1016/j.tiv.2020.104815 · Cited by 86
“The devices mimic in vivo tissue to fluid ratios and fluid flow by using microfluidic technology (Kim et al., 2012; Kim and Ingber, 2013) attempting to better recapitulate the in vivo physiological tissue functioning.”
BackgroundOrgan-on-a-chip platforms for evaluation of environmental nanoparticle toxicity
Lu, R. X. Z., & Radisic, M. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.01.021 · Cited by 94
Microfluidic Gut-on-a-Chip: Fundamentals and Challenges
Thomas, D. P., Zhang, J., Nguyen, N., & Ta, H. T. (2023) · Biosensors · doi:10.3390/bios13010136 · Cited by 95
Peters, M. F., Choy, A. L., Pin, C., Leishman, D. J., Moisan, A., Ewart, L., Guzzie-Peck, P. J., Sura, R., Keller, D. A., Scott, C. W., et al. (2020) · Lab on a Chip · doi:10.1039/c9lc01107b · Cited by 76
Microfluidic lumen-based systems for advancing tubular organ modeling
Virumbrales-Muñoz, M., Ayuso, J. M., Gong, M. M., Humayun, M., Livingston, M. K., Lugo-Cintrón, K. M., McMinn, P., Álvarez-García, Y. R., & Beebe, D. J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00705f · Cited by 76
The Progress of Intestinal Epithelial Models from Cell Lines to Gut-On-Chip
Rahman, S., Ghiboub, M., Donkers, J. M., van de Steeg, E., van Tol, E. A. F., Hakvoort, T. B. M., & de Jonge, W. J. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms222413472 · Cited by 93
Pisapia, F., Balachandran, W., & Rasekh, M. (2022) · Applied Sciences · doi:10.3390/app12083829 · Cited by 85
“Animal studies can provide extremely useful and detailed information on what happens in a complex organism, but many issues are still challenging, such as ethical concerns and difficulties in predicting human reactions and body responses due to differences in both the metabolic rate and the size of animal models [15,1…”
BackgroundKim, H. J., Lee, J., Choi, J.-H., Bahinski, A., & Ingber, D. E. (2016) · Journal of Visualized Experiments · doi:10.3791/54344 · Cited by 69
Engineering microphysiological immune system responses on chips
Miller, C. P., Shin, W., Ahn, E. H., Kim, H. J., & Kim, D.-H. (2020) · Trends in biotechnology · doi:10.1016/j.tibtech.2020.01.003 · Cited by 74
Self-citationLong-term flow through human intestinal organoids with the gut organoid flow chip (GOFlowChip)
Sidar, B., Jenkins, B. R., Huang, S., Spence, J. R., Walk, S. T., & Wilking, J. N. (2019) · Lab on a Chip · doi:10.1039/c9lc00653b · Cited by 73
In vitro models of intestinal epithelium: Toward bioengineered systems
Creff, J., Malaquin, L., & Besson, A. (2021) · Journal of Tissue Engineering · doi:10.1177/2041731420985202 · Cited by 86
Immune Organs and Immune Cells on a Chip: An Overview of Biomedical Applications
Morsink, M., Willemen, N., Leijten, J., Bansal, R., & Shin, S. (2020) · Micromachines · doi:10.3390/mi11090849 · Cited by 73
“[82,90,94] made a peristaltic gut-on-a-chip device with two channels, separated by a porous PDMS membrane coated in ECM.”
Cellular Biomechanics in Drug Screening and Evaluation: Mechanopharmacology
Krishnan, R., Park, J., Seow, C. Y., Lee, P. V. S., & Stewart, A. G. (2015) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2015.10.005 · Cited by 81
“The underlying mechanical–biochemical interactions not only mediate physical and structural changes [90,106,107], but also promote cell adhesion [108], polarization [70], stem cell differentiation [72], locomotion [109– 111], wound healing [112], gene expression [113], angiogenesis [114], and apoptosis [115].”
Mimicking Human Pathophysiology in Organ‐on‐Chip Devices
Yeşil-Çeliktaş, Ö., Hassan, S., Miri, A. K., Maharjan, S., Al‐kharboosh, R., Quiñones‐Hinojosa, A., & Zhang, Y. S. (2018) · Advanced Biosystems · doi:10.1002/adbi.201800109 · Cited by 81
Coculture of primary human colon monolayer with human gut bacteria
Zhang, J., Hernandez‐Gordillo, V., Trapečar, M., Wright, C. W., Taketani, M., Schneider, K., Chen, W. L. K., Stas, E., Breault, D. T., Carrier, R. L., et al. (2021) · Nature Protocols · doi:10.1038/s41596-021-00562-w · Cited by 75
The impact of microfluidics in high-throughput drug-screening applications
Stefano, P. D., Bianchi, E., & Dubini, G. (2022) · Biomicrofluidics · doi:10.1063/5.0087294 · Cited by 84
Clinical translation of microbe‐based therapies: Current clinical landscape and preclinical outlook
Vargason, A. M., & Anselmo, A. C. (2018) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10093 · Cited by 71
“The chip mimicked the key features of the GI tract such as the intestinal barrier properties, intestinal morphology (Figure 5e), anaerobic conditions, shear stress, and peristaltic forces.(92,93) Concomitant administration of the therapeutic microbes and antibiotics protected against lesion formation caused by pathoge…”
BackgroundHartwig, O., Boushehri, M. A. S., Shalaby, K. S., Loretz, B., Lamprecht, A., & Lehr, C. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.113828 · Cited by 74
Li, M., de Graaf, I. A. M., & Groothuis, G. M. M. (2016) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1517/17425255.2016.1125882 · Cited by 80
“[89] The gut microenvironment was also incorporated in the ‘human gut-on-a-chip’ microdevice [90,91] in which Caco-2 cells”
BackgroundDrug absorption related nephrotoxicity assessment on an intestine-kidney chip
Li, Z., Su, W., Zhu, Y., Tao, T., Li, D., Peng, X., & Qin, J. (2017) · Biomicrofluidics · doi:10.1063/1.4984768 · Cited by 72
Architecture in 3D cell culture: An essential feature for in vitro toxicology
Lelièvre, S. A., Kwok, T., & Chittiboyina, S. (2017) · Toxicology in Vitro · doi:10.1016/j.tiv.2017.03.012 · Cited by 74
“Mechanical stimulus led to morphogenesis of intestinal villi with tight junction marker, brush borders and mucus deposition (Kim and Ingber, 2013).”
Ambrosini, Y. M., Park, Y., Jergens, A. E., Shin, W., Min, S., Atherly, T. A., Borcherding, D. C., Jang, J., Allenspach, K., Mochel, J. P., et al. (2020) · PLoS ONE · doi:10.1371/journal.pone.0231423 · Cited by 77
“Another potential application that we envision is to leverage this proof-of-principle study of canine intestinal organoids towards the possible application of an advanced gut-on-a-chip microphysiological platform [14,41].”
BackgroundHinman, S. S., Wang, Y., Kim, R., & Allbritton, N. L. (2020) · Nature Protocols · doi:10.1038/s41596-020-00419-8 · Cited by 70
Tumor-on-a-chip models combined with mini-tissues or organoids for engineering tumor tissues
Hwangbo, H., Chae, S., Kim, W.-J., Jo, S., & Kim, G. (2023) · Theranostics · doi:10.7150/thno.90093 · Cited by 74
“Moreover, Kim et al. incorporated the intestinal barrier using intestinal epithelial cells (Caco-2) cultured in microfluidic OOCs and exposed them to a cyclic mechanical strain similar to that in the native environment [77].”
BackgroundScheidweiler, D., Bordoloi, A., Jiao, W., Sentchilo, V., Bollani, M., Chhun, A., Engel, P., & de Anna, P. (2024) · Nature Communications · doi:10.1038/s41467-023-44267-y · Cited by 74
“Therefore, researchers adopted alternative strategies such as micro fl uidics 16,17 , organoids 18,19 , and in-silico approaches 20,21 to study the impact of fl ow on gut related microorganisms.”
Emulating Host-Microbiome Ecosystem of Human Gastrointestinal Tract in Vitro
Park, G.-S., Park, M. H., Shin, W., Zhao, C., Sheikh, S., Oh, S. J., & Kim, H. J. (2017) · Stem Cell Reviews and Reports · doi:10.1007/s12015-017-9739-z · Cited by 73
“[15, 16, 18] provides a 3D lumen-capillary tissue interface in two juxtaposed microchannels separated by an ECM-coated, flexible porous PDMS membrane lined by human intestinal”
BackgroundMethodInfluentialPerfusable and stretchable 3D culture system for skin-equivalent
Mori, N., Morimoto, Y., & Takeuchi, S. (2018) · Biofabrication · doi:10.1088/1758-5090/aaed12 · Cited by 70
The small intestine: dining table of host–microbiota meetings
Delbaere, K., Roegiers, I. H., Bron, A., Durif, C., de Wiele, T. V., Blanquet‐Diot, S., & Marinelli, L. (2023) · FEMS Microbiology Reviews · doi:10.1093/femsre/fuad022 · Cited by 79
“For example, exposing Caco-2 cells to fluidic shear or periodic contraction, induces the expression of metabolic enzymes, m ucus pr oteins, as well as formation of villus-like structures (Kim and Ingber 2013 , Lindner et al. 2021 ).”
Timescales of gut microbiome dynamics
Schlomann, B. H., & Parthasarathy, R. (2019) · Current Opinion in Microbiology · doi:10.1016/j.mib.2019.09.011 · Cited by 74
““guts-on-a-chip,” which can include cultured host cells (78) and peristalsis-like flows (70) enable exquisite experimental control, and are increasingly realistic.”
BackgroundMicrofluidic devices for studying bacterial taxis, drug testing and biofilm formation
Pérez-Rodríguez, S., García‐Aznar, J. M., & Gonzalo‐Asensio, J. (2021) · Microbial Biotechnology · doi:10.1111/1751-7915.13775 · Cited by 78
“Some of the organs that have been simulated thanks to microfluidics are the gut (Kim and Ingber, 2013), lung (Huh, 2015), liver (Ho et al., 2006), endothelial vessels (Polacheck et al., 2019) and brain (Bang et al., 2019).”
BackgroundIn Vitro Immune Organs-on-Chip for Drug Development: A Review
Shanti, A., Teo, J., & Stefanini, C. (2018) · Pharmaceutics · doi:10.3390/pharmaceutics10040278 · Cited by 65
“Further extending the results, Kim and Ingber utilized that same gut-on chip model with its peristalsis generating capability to examine the morphogenesis of the polarized epithelium and the subsequent formation of villus-like structures [65].”
ResultA 3D toolbox to enhance physiological relevance of human tissue models
Picollet-D’hahan, N., Dolega, M. E., Liguori, L., Marquette, C., Le Gac, S., Gidrol, X., & Martin, D. K. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.06.012 · Cited by 65
Cherne, M. D., Sidar, B., Sebrell, T. A., Sanchez, H. S., Heaton, K., Kassama, F. J., Roe, M. M., Gentry, A. B., Chang, C. B., Walk, S. T., et al. (2021) · Frontiers in Pharmacology · doi:10.3389/fphar.2021.707891 · Cited by 73
“Sophisticated microphysiological systems (MPSs) that integrate gastrointestinal epithelial cell monolayers and immune components also have been established by multiple groups (Kim and Ingber, 2013; Kim et al., 2016; Shin and Kim, 2018; Beaurivage et al., 2020).”
BackgroundMarkandan, K., Tiong, Y. W., Sankaran, R., Sakthinathan, S., Markandan, U. D., Chaudhary, V., Numan, A., Khalid, M., & Walvekar, R. (2022) · Biotechnology and Genetic Engineering Reviews · doi:10.1080/02648725.2022.2127070 · Cited by 70
Microfluidic trends in drug screening and drug delivery
Feng, J., Neužil, J., Manz, A., Iliescu, C., & Neužil, P. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116821 · Cited by 70
DiMarco, R. L., Hunt, D. R., Dewi, R. E., & Heilshorn, S. C. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.03.023 · Cited by 64
“Various three-dimensional (3D) drug screening models have also 34 been developed, including organoid structures derived from primary tissue(25,26) and microfluidic, organ-on-a-chip devices.(27) 35 While scientifically interesting, these strategies are technically cumbersome and not readily translatable to high36 throu…”
BackgroundAshammakhi, N. A., Darabi, M. A., Çelebi‐Saltik, B., Tutar, R., Hartel, M. C., Lee, J., Hussein, S. M., Goudie, M. J., Cornelius, M. B., Dokmeci, M. R., et al. (2019) · Small Methods · doi:10.1002/smtd.201900589 · Cited by 74
Organoids/organs-on-a-chip: new frontiers of intestinal pathophysiological models
Wu, L., Ai, Y., Xie, R., Xiong, J., Wang, Y., & Liang, Q. (2023) · Lab on a Chip · doi:10.1039/d2lc00804a · Cited by 69
Evaluating Human Intestinal Cell Lines for Studying Dietary Protein Absorption
Jochems, P., Garssen, J., Van Keulen, A., Masereeuw, R., & Jeurink, P. (2018) · Nutrients · doi:10.3390/nu10030322 · Cited by 64
“[99,101] established a model mimicking the peristaltic movement of the intestine, through which they concluded that addition of flow altered the rate of differentiation and spontaneous formation of villi.”
Organ-on-a-Chip Applications in Microfluidic Platforms
An, L., Liu, Y., & Liu, Y. (2025) · Micromachines · doi:10.3390/mi16020201 · Cited by 79
“This includes processes like pulmonary respiration and cardiac pulsation [59,60].”
A biologically inspired lung-on-a-chip device for the study of protein-induced lung inflammation
Punde, T. H., Wu, W., Lien, P.-C., Chang, Y., Kuo, P.-H., Chang, M. D., Lee, K., Huang, C., Kuo, H., Chan, Y.-F., et al. (2014) · Integrative Biology · doi:10.1039/c4ib00239c · Cited by 67
Hydrogel‐based three‐dimensional cell culture for organ‐on‐a‐chip applications
Lee, S. H., Shim, K. Y., Kim, B., & Sung, J. H. (2017) · Biotechnology Progress · doi:10.1002/btpr.2457 · Cited by 63
Use of hydrogel scaffolds to develop an in vitro 3D culture model of human intestinal epithelium
Dosh, R. H., Essa, A., Jordan, N., Sammon, C., & Maitre, C. L. L. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.08.035 · Cited by 65
Metadata
- Authors
- Kim, H. J., & Ingber, D. E.
- Affiliations
- Harvard University (US)
- Boston Children's Hospital (US)
- Corresponding author
- Ingber, Donald E.
- Venue
- Integrative Biology
- Publisher
- Oxford University Press (OUP)
- Published
- 2013
- Volume
- 5
- Issue
- 9
- Pages
- 1130
- ISSN
- 1757-9694 (ISSN-L)
- 1757-9708
- OpenAlex
- W1985656429
- Cited by
- 750
- References
- 67
- Citations by year
- 2026: 38 · 2025: 55 · 2024: 70 · 2023: 69 · 2022: 58 · 2021: 85 · 2020: 84 · 2019: 65 · 2018: 64 · 2017: 66 · 2016: 43 · 2015: 31 · 2014: 21 · 2013: 1
- FWCI
- 17.63
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Integrative Biology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Environmental Health Sciences (R01ES016665, ES016665-01A1)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- gut-on-a-chip, Caco-2 cells, organ-on-a-chip, intestinal morphogenesis, crypt-villus axis, intestinal epithelial differentiation, enteroendocrine cells, Paneth cells, mucus secretion, intestinal surface area, CYP3A4, drug metabolism, intestinal physiology, in vitro intestinal model
- MeSH terms
- Cell Differentiation, Humans, Intestinal Mucosa, Intestine, Small, Microscopy, Electron, Scanning, Microscopy, Fluorescence, Microscopy, Phase-Contrast, Morphogenesis, Caco-2 Cells, Microfluidic Analytical Techniques, Cytochrome P-450 CYP3A
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.