The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Capillary microfluidics in microchannels: from microfluidic networks to capillaric circuits
Open accessAbstract
This review critically analyzes the history, fundamental operating principles, limitations, applications, and emerging ideas related to microchannel-based capillary microfluidics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
The Dynamics of Capillary Flow
Washburn, E. W. (1921) · Physical Review · doi:10.1103/physrev.17.273 · Cited by 7,141
III. An essay on the cohesion of fluids
Young, T. (1805) · Philosophical Transactions of the Royal Society of London · doi:10.1098/rstl.1805.0005 · Cited by 6,643
Miniaturized total chemical analysis systems: A novel concept for chemical sensing
Manz, A., Graber, N., & Widmer, H. M. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80209-i · Cited by 3,122
Soft lithography for micro- and nanoscale patterning
Qin, D., Xia, Y., & Whitesides, G. M. (2010) · Nature Protocols · doi:10.1038/nprot.2009.234 · Cited by 2,334
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
3D printed microfluidic devices: enablers and barriers
Waheed, S., Cabot, J. M., Macdonald, N. P., Lewis, T., Guijt, R. M., Paull, B., & Breadmore, M. C. (2016) · Lab on a Chip · doi:10.1039/c6lc00284f · Cited by 1,039
Polymer microstructures formed by moulding in capillaries
Kim, E., Xia, Y., & Whitesides, G. M. (1995) · Nature · doi:10.1038/376581a0 · Cited by 878
A perspective on paper-based microfluidics: Current status and future trends
Li, X., Ballerini, D. R., & Shen, W. (2012) · Biomicrofluidics · doi:10.1063/1.3687398 · Cited by 813
Au, A. K., Huynh, W., Horowitz, L. F., & Folch, A. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201504382 · Cited by 788
Surface-Directed Liquid Flow Inside Microchannels
Zhao, B., Moore, J. S., & Beebe, D. J. (2001) · Science · doi:10.1126/science.291.5506.1023 · Cited by 765
Microfluidics-based diagnostics of infectious diseases in the developing world
Chin, C. D., Laksanasopin, T., Cheung, Y. K., Steinmiller, D., Linder, V., Parsa, H., Wang, J., Moore, H., Rouse, R., Umviligihozo, G., et al. (2011) · Nature Medicine · doi:10.1038/nm.2408 · Cited by 759
Patterned Delivery of Immunoglobulins to Surfaces Using Microfluidic Networks
Delamarche, E., Bernard, A., Schmid, H., Michel, B., & Biebuyck, H. (1997) · Science · doi:10.1126/science.276.5313.779 · Cited by 678
Bodas, D., & Khan-Malek, C. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.08.037 · Cited by 600
Paper-Based Microfluidic Devices: Emerging Themes and Applications
Yang, Y., Noviana, E., Nguyen, M. P., Geiss, B. J., Dandy, D. S., & Henry, C. S. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04581 · Cited by 501
ON THE BEHAVIOR OF A CAPILLARY SURFACE IN A WEDGE
Concus, P., & Finn, R. (1969) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.63.2.292 · Cited by 477
Custom 3D printer and resin for 18 μm × 20 μm microfluidic flow channels
Gong, H., Bickham, B. P., Woolley, A. T., & Nordin, G. P. (2017) · Lab on a Chip · doi:10.1039/c7lc00644f · Cited by 443
Yamada, K., Shibata, H., Suzuki, K., & Citterio, D. (2017) · Lab on a Chip · doi:10.1039/c6lc01577h · Cited by 437
Autonomous Microfluidic Capillary System
Juncker, D., Schmid, H., Drechsler, U., Wolf, H., Wolf, M., Michel, B., de Rooij, N., & Delamarche, E. (2002) · Analytical Chemistry · doi:10.1021/ac0261449 · Cited by 426
Self-citationComparing Microfluidic Performance of Three-Dimensional (3D) Printing Platforms
Macdonald, N. P., Cabot, J. M., Smejkal, P., Guijt, R. M., Paull, B., & Breadmore, M. C. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00136 · Cited by 425
A passive pumping method for microfluidic devices
Walker, G. M., & Beebe, D. J. (2002) · Lab on a Chip · doi:10.1039/b204381e · Cited by 420
Microfluidic Networks for Chemical Patterning of Substrates: Design and Application to Bioassays
Delamarche, E., Bernard, A., Schmid, H., Bietsch, A., Michel, B., & Biebuyck, H. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973071f · Cited by 412
Capillary pumps for autonomous capillary systems
Zimmermann, M., Schmid, H., Hunziker, P., & Delamarche, E. (2007) · Lab Chip · doi:10.1039/b609813d · Cited by 380
Xurography: rapid prototyping of microstructures using a cutting plotter
Bartholomeusz, D. A., Boutte, R. W., & Andrade, J. D. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.859087 · Cited by 360
Recent Advances in Analytical Chemistry by 3D Printing
Gross, B., Lockwood, S. Y., & Spence, D. M. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04344 · Cited by 359
Gervais, L., & Delamarche, E. (2009) · Lab on a Chip · doi:10.1039/b906523g · Cited by 345
Carlborg, C. F., Haraldsson, T., Öberg, K., Malkoch, M., & van der Wijngaart, W. (2011) · Lab on a Chip · doi:10.1039/c1lc20388f · Cited by 328
Choi, J., Kang, D., Han, S., Kim, S. B., & Rogers, J. A. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201601355 · Cited by 315
Transport in two-dimensional paper networks
Fu, E., Ramsey, S. A., Kauffman, P., Lutz, B., & Yager, P. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0643-y · Cited by 313
How the capillary burst microvalve works
Cho, H., Kim, H.-Y., Kang, J. Y., & Kim, T. S. (2007) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2006.10.077 · Cited by 298
High density 3D printed microfluidic valves, pumps, and multiplexers
Gong, H., Woolley, A. T., & Nordin, G. P. (2016) · Lab on a Chip · doi:10.1039/c6lc00565a · Cited by 263
Towards non- and minimally instrumented, microfluidics-based diagnostic devices
Weigl, B., Domingo, G., LaBarre, P., & Gerlach, J. (2008) · Lab on a Chip · doi:10.1039/b811314a · Cited by 259
Sugioka, K., Xu, J., Wu, D., Hanada, Y., Wang, Z., Cheng, Y., & Midorikawa, K. (2014) · Lab Chip · doi:10.1039/c4lc00548a · Cited by 259
Phaseguides: a paradigm shift in microfluidic priming and emptying
Vulto, P., Podszun, S., Meyer, P., Hermann, C., Manz, A., & Urban, G. A. (2011) · Lab on a Chip · doi:10.1039/c0lc00643b · Cited by 222
High-sensitivity miniaturized immunoassays for tumor necrosis factor ? using microfluidic systems
Cesaro-Tadic, S., Dernick, G., Juncker, D., Buurman, G., Kropshofer, H., Michel, B., Fattinger, C., & Delamarche, E. (2004) · Lab on a Chip · doi:10.1039/b408964b · Cited by 203
Self-citationWolf, M., Juncker, D., Michel, B., Hunziker, P., & Delamarche, E. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.11.003 · Cited by 193
Self-citationFlow rate analysis of a surface tension driven passive micropump
Berthier, E., & Beebe, D. J. (2007) · Lab on a Chip · doi:10.1039/b707637a · Cited by 191
Capillarics: pre-programmed, self-powered microfluidic circuits built from capillary elements
Safavieh, R., & Juncker, D. (2013) · Lab on a Chip · doi:10.1039/c3lc50691f · Cited by 190
Self-citationCasavant, B. P., Berthier, E., Theberge, A. B., Berthier, J., Montanez-Sauri, S. I., Bischel, L. L., Brakke, K., Hedman, C. J., Bushman, W., Keller, N. P., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1302566110 · Cited by 178
Valves for autonomous capillary systems
Zimmermann, M. N., Hunziker, P., & Delamarche, E. (2008) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0256-2 · Cited by 174
Exploration of microfluidic devices based on multi-filament threads and textiles: A review
Nilghaz, A., Ballerini, D. R., & Shen, W. (2013) · Biomicrofluidics · doi:10.1063/1.4820413 · Cited by 159
Analysis and experiment of capillary valves for microfluidics on a rotating disk
Chen, J. M., Huang, P.-C., & Lin, M.-G. (2008) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0196-x · Cited by 158
Progress in the development and integration of fluid flow control tools in paper microfluidics
Fu, E. S., & Downs, C. (2017) · Lab on a Chip · doi:10.1039/c6lc01451h · Cited by 141
Silane–dextran chemistry on lateral flow polymer chips for immunoassays
Jönsson, C., Aronsson, M., Rundström, G., Pettersson, C., Mendel-Hartvig, I., Bakker, J. W. P., Martinsson, E., Liedberg, B., MacCraith, B. D., Öhman, O., et al. (2008) · Lab on a Chip · doi:10.1039/b800297e · Cited by 132
Passive microfluidic pumping using coupled capillary/evaporation effects
Lynn, N. S., Jr., & Dandy, D. S. (2009) · Lab on a Chip · doi:10.1039/b912213c · Cited by 121
CD-Based Microfluidics for Primary Care in Extreme Point-of-Care Settings
Smith, S., Mager, D., Perebikovsky, A., Shamloo, E., Kinahan, D. J., Mishra, R., Delgado, S. T., Kido, H., Saha, S., Ducrée, J., et al. (2016) · Micromachines · doi:10.3390/mi7020022 · Cited by 118
Kai, J., Puntambekar, A., Vispo, N. S., Lee, S. H., Sehy, D. W., Moore, V. S., Han, J., & Ahn, C. H. (2012) · Lab on a Chip · doi:10.1039/c2lc40585g · Cited by 103
Autonomous microfluidic capillaric circuits replicated from 3D-printed molds
Olanrewaju, A. O., Robillard, A., Dagher, M., & Juncker, D. (2016) · Lab on a Chip · doi:10.1039/c6lc00764c · Cited by 95
Self-citationWang, J., Ahmad, H. M. N., Ma, C., Shi, Q., Vermesh, O., Vermesh, U., & Heath, J. R. (2010) · Lab on a Chip · doi:10.1039/c0lc00132e · Cited by 93
Capillary-driven multiparametric microfluidic chips for one-step immunoassays
Gervais, L., Hitzbleck, M., & Delamarche, E. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.06.016 · Cited by 91
Continuous flow in open microfluidics using controlled evaporation
Zimmermann, M., Bentley, S., Schmid, H., Hunziker, P., & Delamarche, E. (2005) · Lab on a Chip · doi:10.1039/b510044e · Cited by 85
Evaporation driven pumping for chromatography application
Goedecke, N., Eijkel, J. C. T., & Manz, A. (2002) · Lab on a Chip · doi:10.1039/b208031c · Cited by 83
Microfluidic logic gates and timers
Toepke, M. W., Abhyankar, V. V., & Beebe, D. J. (2007) · Lab on a Chip · doi:10.1039/b708764k · Cited by 73
Mohammed, M.-I., & Desmulliez, M. P. Y. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.05.042 · Cited by 65
Microfluidic Capillaric Circuit for Rapid and Facile Bacteria Detection
Olanrewaju, A. O., Ng, A., DeCorwin‐Martin, P., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01315 · Cited by 64
Self-citationWater in micro- and nanofluidics systems described using the water potential
Eijkel, J. C. T., & van den Berg, A. (2005) · Lab on a Chip · doi:10.1039/b509819j · Cited by 60
Micro-scale metal contacts for capillary force-driven self-assembly
Morris, C. J., & Parviz, B. A. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/1/015022 · Cited by 56
Novo, P., Chu, V., & Conde, J. P. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.02.009 · Cited by 49
Ramalingam, N., Liu, H.-B., Dai, C., Jiang, Y. S., Wang, H., Wang, Q., Hui, K. M., & Gong, H. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9318-4 · Cited by 45
Autonomous capillary system for one-step immunoassays
Zimmermann, M., Hunziker, P., & Delamarche, E. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9187-2 · Cited by 42
Controlled release of reagents in capillary-driven microfluidics using reagent integrators
Hitzbleck, M., Gervais, L., & Delamarche, E. (2011) · Lab on a Chip · doi:10.1039/c1lc20282k · Cited by 41
Disposable Autonomous Device for Swab-to-Result Diagnosis of Influenza
Huang, S., Abe, K., Bennett, S. P., Liang, T., Ladd, P. D., Yokobe, L., Anderson, C. E., Shah, K. G., Bishop, J., Purfield, M., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04801 · Cited by 39
Phaseguides as tunable passive microvalves for liquid routing in complex microfluidic networks
Yıldırım, E., Trietsch, S. J., Joore, J., van den Berg, A., Hankemeier, T., & Vulto, P. (2014) · Lab on a Chip · doi:10.1039/c4lc00261j · Cited by 35
Kim, S., Paczesny, S., Takayama, S., & Kurabayashi, K. (2013) · Lab on a Chip · doi:10.1039/c3lc50187f · Cited by 32
Preprogrammed, Parallel On-Chip Immunoassay Using System-Level Capillarity Control
Kim, S., Paczesny, S., Takayama, S., & Kurabayashi, K. (2013) · Analytical Chemistry · doi:10.1021/ac401292d · Cited by 22
Absorbent-force-driven microflow cytometer
Lee, Y., & Hsieh, W. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.05.117 · Cited by 10
Ramalingam, N., Warkiani, M. E., Ramalingam, N., Keshavarzi, G., Liu, H.-B., & Gong, T. H. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0099-2 · Cited by 10
Yan, S., Zhu, Y., Tang, S., Li, Y., Zhao, Q., Yuan, D., Yun, G., Zhang, J., Zhang, S., & Li, W. (2018) · Electrophoresis · doi:10.1002/elps.201700449 · Cited by 7
Cited by
Advances and applications of nanophotonic biosensors
Altug, H., Oh, S.-H., Maier, S. A., & Homola, J. (2022) · Nature Nanotechnology · doi:10.1038/s41565-021-01045-5 · Cited by 882
Fabrication and Applications of Microfluidic Devices: A Review
Niculescu, A.-G., Chircov, C., Bîrcă, A. C., & Grumezescu, A. M. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22042011 · Cited by 678
Magnetite nanoparticles: Synthesis methods – A comparative review
Niculescu, A.-G., Chircov, C., & Grumezescu, A. M. (2022) · Methods · doi:10.1016/j.ymeth.2021.04.018 · Cited by 331
Injectable Microfluidic Hydrogel Microspheres for Cell and Drug Delivery
Zhao, Z., Wang, Z., Li, G., Cai, Z., Wu, J., Wang, L., Deng, L., Cai, M., & Cui, W. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202103339 · Cited by 277
Shajari, S., Salahandish, R., Zare, A., Hassani, M., Moossavi, S., Munro, E., Rashid, R., Rosenegger, D., Bains, J. S., & Sanati Nezhad, A. (2023) · Advanced Science · doi:10.1002/advs.202204171 · Cited by 55
Metadata
- Authors
- Olanrewaju, A., Beaugrand, M., Yafia, M., & Juncker, D.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2018
- Volume
- 18
- Issue
- 16
- Pages
- 2323-2347
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2883384123
- Cited by
- 451
- References
- 69
- FWCI
- 12.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.