CoChat

Complete validation of a continuous and blood-correlated sweat biosensing device with integrated sweat stimulation

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

A wearable sweat biosensing device is demonstrated that stimulates sweat and continuously measures sweat ethanol concentrations at 25 s intervals, which is then correlated with blood ethanol during a >3 hour testing phase.

Overview

Integrity signals

Registry

Crossref · 10.1039/c8lc01082j

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

2 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 34 references

Research works printed but not linked: 4

  1. Heikenfeld, 2019, Nat. Biotechnol.
  2. Sempionatto, 2018, Electroanalysis, 1
  3. Vukovic, 2015, J. Subst. Abus. Alcohol, 3, 1
  4. Emaminejad, 2017, Proc. Natl. Acad. Sci. U. S. A., 201701740

Cited by

Metadata

Authors
Hauke, A., Simmers, P., Ojha, Y. R., Cameron, B. D., Ballweg, R., Zhang, T., Twine, N., Brothers, M., Gomez, E., & Heikenfeld, J.
Affiliations
  • University of Cincinnati (US)
  • University of Toledo (US)
  • UES (United States) (US)
Corresponding author
Heikenfeld, J.
Venue
Lab on a Chip
Published
2018
Volume
18
Issue
24
Pages
3750-3759
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2898863309
Cited by
156
References
34
Citations by year
2026: 15 · 2025: 14 · 2024: 26 · 2023: 14 · 2022: 22 · 2021: 24 · 2020: 22 · 2019: 19
FWCI
6.22
Type
journal article
Language
en
Open access
closed
Locations
  • Lab on a Chip (publishedVersion)
  • PubMed (publishedVersion)
  • OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
Funders
  • Oak Ridge Institute for Science and Education
  • Air Force Research Laboratory (FA8650-15-C-6625)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
Keywords
wearable sensors, ethanol detection, pharmacokinetics, continuous monitoring, alcohol metabolism, sensor validation
MeSH terms
Wearable Electronic Devices, Ethanol, Equipment Design, Humans, Sweat, Reproducibility of Results, Biosensing Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.