Microdissected “cuboids” for microfluidic drug testing of intact tissues
Open accessThe DOI matches its Crossref record; 79 of the 79 references it cites were found in a registry or an index.
Abstract
A microfluidic platform permits multiple drug testing of uniformly-sized microscale “cuboids” of live tissue with well-preserved microenvironments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“They observed that astrocytes directly enhanced tumor cell extravasation across the BBB via C‐C motif chemokine ligand 2 (CCL2) secretion, which was similar to in vivo observations.”
From 3D Biomimetic Models to Reconstitute Tumor Microenvironment In Vitro: Spheroids, Organoids, and Tumor‐on‐a‐Chip (2023) · cites this paper as [134]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fiji: an open-source platform for biological-image analysis
Schindelin, J., Arganda-Carreras, I., Frise, E., Kaynig, V., Longair, M., Pietzsch, T., Preibisch, S., Rueden, C., Saalfeld, S., Schmid, B., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2019 · Cited by 66,890
Modeling Development and Disease with Organoids
Clevers, H. (2016) · Cell · doi:10.1016/j.cell.2016.05.082 · Cited by 3,196
Prospective Derivation of a Living Organoid Biobank of Colorectal Cancer Patients
van de Wetering, M., Francies, H. E., Francis, J. M., Bounova, G., Iorio, F., Pronk, A., van Houdt, W., van Gorp, J., Taylor-Weiner, A., Kester, L., et al. (2015) · Cell · doi:10.1016/j.cell.2015.03.053 · Cited by 2,408
Organoid models of human and mouse ductal pancreatic cancer
Boj, S. F., Hwang, C.-I., Baker, L. A., Chio, I. I. C., Engle, D. D., Corbo, V., Jager, M., Ponz-Sarvise, M., Tiriac, H., Spector, M. S., et al. (2015) · Cell · doi:10.1016/j.cell.2014.12.021 · Cited by 2,150
A living biobank of breast cancer organoids captures disease heterogeneity
Sachs, N., de Ligt, J., Kopper, O., Gogola, E., Bounova, G., Weeber, F., Balgobind, A. V., Wind, K., Gracanin, A., Begthel, H., et al. (2018) · Cell · doi:10.1016/j.cell.2017.11.010 · Cited by 1,973
Organoid Cultures Derived from Patients with Advanced Prostate Cancer
Gao, D., Vela, I., Sboner, A., Iaquinta, P. J., Karthaus, W. R., Gopalan, A., Dowling, C., Wanjala, J. N., Undvall, E. A., Arora, V. K., et al. (2014) · Cell · doi:10.1016/j.cell.2014.08.016 · Cited by 1,559
Organoid modeling of the tumor immune microenvironment
Neal, J. T., Li, X., Zhu, J., Giangarra, V., Grzeskowiak, C. L., Ju, J., Liu, I. H., Chiou, S.-H., Salahudeen, A. A., Smith, A. R., et al. (2018) · Cell · doi:10.1016/j.cell.2018.11.021 · Cited by 1,556
PDMS absorption of small molecules and consequences in microfluidic applications
Toepke, M. W., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b612140c · Cited by 1,190
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Zanoni, M., Piccinini, F., Arienti, C., Zamagni, A., Santi, S., Polico, R., Bevilacqua, A., & Tesei, A. (2016) · Scientific Reports · doi:10.1038/srep19103 · Cited by 1,144
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
Personalized In Vitro and In Vivo Cancer Models to Guide Precision Medicine
Pauli, C., Hopkins, B. D., Prandi, D., Shaw, R., Fedrizzi, T., Sboner, A., Sailer, V., Augello, M., Puca, L., Rosati, R., et al. (2017) · Cancer Discovery · doi:10.1158/2159-8290.cd-16-1154 · Cited by 937
Sustained in vitro intestinal epithelial culture within a Wnt-dependent stem cell niche
Ootani, A., Li, X., Sangiorgi, E., Ho, Q. T., Ueno, H., Toda, S., Sugihara, H., Fujimoto, K., Weissman, I. L., Capecchi, M. R., et al. (2009) · Nature Medicine · doi:10.1038/nm.1951 · Cited by 906
Engineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
Huang, L., Holtzinger, A., Jagan, I., BeGora, M., Lohse, I., Ngai, N., Nostro, C., Wang, R., Muthuswamy, L. B., Crawford, H. C., et al. (2015) · Nature Medicine · doi:10.1038/nm.3973 · Cited by 740
Biological implications of polydimethylsiloxane-based microfluidic cell culture
Regehr, K. J., Domenech, M., Koepsel, J. T., Carver, K. C., Ellison-Zelski, S. J., Murphy, W. L., Schuler, L. A., Alarid, E. T., & Beebe, D. J. (2009) · Lab on a Chip · doi:10.1039/b903043c · Cited by 719
Are animal models predictive for humans?
Shanks, N., Greek, R., & Greek, J. (2009) · Philosophy, Ethics, and Humanities in Medicine · doi:10.1186/1747-5341-4-2 · Cited by 677
Organs-on-a-Chip: A Fast Track for Engineered Human Tissues in Drug Development
Ronaldson-Bouchard, K., & Vunjak-Novakovic, G. (2018) · Cell Stem Cell · doi:10.1016/j.stem.2018.02.011 · Cited by 657
Ex Vivo Profiling of PD-1 Blockade Using Organotypic Tumor Spheroids
Jenkins, R. W., Aref, A. R., Lizotte, P. H., Ivanova, E., Stinson, S., Zhou, C. W., Bowden, M., Deng, J., Liu, H., Miao, D., et al. (2018) · Cancer Discovery · doi:10.1158/2159-8290.cd-17-0833 · Cited by 594
A trap-and-release integrated microfluidic system for dynamic microarray applications
Tan, W.-H., & Takeuchi, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0606625104 · Cited by 591
Organoid-on-a-chip and body-on-a-chip systems for drug screening and disease modeling
Skardal, A., Shupe, T., & Atala, A. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.07.003 · Cited by 512
Small molecule absorption by PDMS in the context of drug response bioassays
van Meer, B. J., de Vries, H., Firth, K. S. A., van Weerd, J., Tertoolen, L. G. J., Karperien, H. B. J., Jonkheijm, P., Denning, C., IJzerman, A. P., & Mummery, C. L. (2017) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2016.11.062 · Cited by 502
Oncogenic transformation of diverse gastrointestinal tissues in primary organoid culture
Li, X., Nadauld, L., Ootani, A., Corney, D. C., Pai, R. K., Gevaert, O., Cantrell, M. A., Rack, P. G., Neal, J. T., Chan, C. W.-M., et al. (2014) · Nature Medicine · doi:10.1038/nm.3585 · Cited by 442
Light-sheet microscopy for slide-free non-destructive pathology of large clinical specimens
Glaser, A. K., Reder, N. P., Chen, Y., McCarty, E. F., Yin, C., Wei, L., Wang, Y., True, L. D., & Liu, J. T. C. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0084 · Cited by 419
Self-citationMicrofluidic Networks for Chemical Patterning of Substrates: Design and Application to Bioassays
Delamarche, E., Bernard, A., Schmid, H., Bietsch, A., Michel, B., & Biebuyck, H. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973071f · Cited by 412
BigStitcher: reconstructing high-resolution image datasets of cleared and expanded samples
Hörl, D., Rojas Rusak, F., Preusser, F., Tillberg, P., Randel, N., Chhetri, R. K., Cardona, A., Keller, P. J., Harz, H., Leonhardt, H., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0501-0 · Cited by 383
Functional precision cancer medicine—moving beyond pure genomics
Letai, A. (2017) · Nature Medicine · doi:10.1038/nm.4389 · Cited by 366
Klingberg, A., Hasenberg, A., Ludwig-Portugall, I., Medyukhina, A., Männ, L., Brenzel, A., Engel, D. R., Figge, M. T., Kurts, C., & Gunzer, M. (2017) · Journal of the American Society of Nephrology · doi:10.1681/asn.2016020232 · Cited by 343
Humanized mice in studying efficacy and mechanisms of PD‐1‐targeted cancer immunotherapy
Wang, M., Yao, L., Cheng, M., Cai, D., Martinek, J., Pan, C., Shi, W., Ma, A., de Vere White, R. W., Airhart, S., et al. (2018) · The FASEB Journal · doi:10.1096/fj.201700740r · Cited by 339
Precise measurement of diffusion by multi-color dual-focus fluorescence correlation spectroscopy
Müller, C. B., Loman, A., Pacheco, V., Koberling, F., Willbold, D., Richtering, W., & Enderlein, J. (2008) · EPL (Europhysics Letters) · doi:10.1209/0295-5075/83/46001 · Cited by 283
Preclinical model of organotypic culture for pharmacodynamic profiling of human tumors
Vaira, V., Fedele, G., Pyne, S., Fasoli, E., Zadra, G., Bailey, D., Snyder, E., Faversani, A., Coggi, G., Flavin, R., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0907676107 · Cited by 267
Moshksayan, K., Kashaninejad, N., Warkiani, M. E., Lock, J. G., Moghadas, H., Firoozabadi, B., Saidi, M. S., & Nguyen, N.-T. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.01.223 · Cited by 267
3D microfluidic ex vivo culture of organotypic tumor spheroids to model immune checkpoint blockade
Aref, A. R., Campisi, M., Ivanova, E., Portell, A., Larios, D., Piel, B. P., Mathur, N., Zhou, C., Coakley, R. V., Bartels, A., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc00322j · Cited by 265
Quantitative Analysis of Molecular Absorption into PDMS Microfluidic Channels
Wang, J. D., Douville, N. J., Takayama, S., & ElSayed, M. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0562-z · Cited by 265
Density and Viscosity of Concentrated Aqueous Solutions of Polyethylene Glycol
Gonzalez-Tello, P., Camacho, F., & Blazquez, G. (1994) · Journal of Chemical & Engineering Data · doi:10.1021/je00015a050 · Cited by 243
Modeling Pancreatic Cancer with Organoids
Baker, L. A., Tiriac, H., Clevers, H., & Tuveson, D. A. (2016) · Trends in Cancer · doi:10.1016/j.trecan.2016.03.004 · Cited by 210
Multi-immersion open-top light-sheet microscope for high-throughput imaging of cleared tissues
Glaser, A. K., Reder, N. P., Chen, Y., Yin, C., Wei, L., Kang, S., Barner, L. A., Xie, W., McCarty, E. F., Mao, C., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-10534-0 · Cited by 203
Self-citationOptimization of microfluidic single cell trapping for long-term on-chip culture
Kobel, S., Valero, A., Latt, J., Renaud, P., & Lutolf, M. (2010) · Lab on a Chip · doi:10.1039/b918055a · Cited by 195
Polyploidization in Liver Tissue
Gentric, G., & Desdouets, C. (2014) · The American Journal of Pathology · doi:10.1016/j.ajpath.2013.06.035 · Cited by 192
An implantable microdevice to perform high-throughput in vivo drug sensitivity testing in tumors
Jonas, O., Landry, H. M., Fuller, J. E., Santini, J. T., Baselga, J., Tepper, R. I., Cima, M. J., & Langer, R. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.3010564 · Cited by 189
Reduction of surface roughness for optical quality microfluidic devices in PMMA and COC
Ogilvie, I. R. G., Sieben, V. J., Floquet, C. F. A., Zmijan, R., Mowlem, M. C., & Morgan, H. (2010) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/20/6/065016 · Cited by 185
Screening therapeutic EMT blocking agents in a three-dimensional microenvironment
Aref, A. R., Huang, R. Y.-J., Yu, W., Chua, K.-N., Sun, W., Tu, T.-Y., Bai, J., Sim, W.-J., Zervantonakis, I. K., Thiery, J. P., et al. (2013) · Integr. Biol. · doi:10.1039/c2ib20209c · Cited by 183
Micro-dissected tumor tissues on chip: an ex vivo method for drug testing and personalized therapy
Astolfi, M., Péant, B., Lateef, M. A., Rousset, N., Kendall-Dupont, J., Carmona, E., Monet, F., Saad, F., Provencher, D., Mes-Masson, A.-M., et al. (2016) · Lab on a Chip · doi:10.1039/c5lc01108f · Cited by 182
Baratta, J. L., Ngo, A., Lopez, B., Kasabwalla, N., Longmuir, K. J., & Robertson, R. T. (2009) · Histochemistry and Cell Biology · doi:10.1007/s00418-009-0577-1 · Cited by 180
On the relation between size of necrosis and diameter of tumor spheroids
Groebe, K., & Mueller-Klieser, W. (1996) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(95)02065-9 · Cited by 153
Population pharmacokinetics of total and unbound plasma cisplatin in adult patients
Urien, S., & Lokiec, F. (2004) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.2004.02082.x · Cited by 151
Shirure, V. S., & George, S. C. (2017) · Lab on a Chip · doi:10.1039/c6lc01401a · Cited by 135
Virtual Hematoxylin and Eosin Transillumination Microscopy Using Epi-Fluorescence Imaging
Giacomelli, M. G., Husvogt, L., Vardeh, H. G., Faulkner-Jones, B. E., Joachim Hornegger, A., Connolly, J. L., & Fujimoto, J. G. (2016) · PLoS ONE · doi:10.1371/journal.pone.0159337 · Cited by 120
A microfluidic platform for chemoresistive testing of multicellular pleural cancer spheroids
Ruppen, J., Cortes-Dericks, L., Marconi, E., Karoubi, G., Schmid, R. A., Peng, R., Marti, T. M., & Guenat, O. T. (2014) · Lab Chip · doi:10.1039/c3lc51093j · Cited by 105
Flamier, A., Abdouh, M., Hamam, R., Barabino, A., Patel, N., Gao, A. Y. L., Hanna, R., & Bernier, G. (2020) · npj Precision Oncology · doi:10.1038/s41698-019-0106-1 · Cited by 100
A technology platform to assess multiple cancer agents simultaneously within a patient’s tumor
Klinghoffer, R. A., Bahrami, S. B., Hatton, B. A., Frazier, J. P., Moreno-Gonzalez, A., Strand, A. D., Kerwin, W. S., Casalini, J. R., Thirstrup, D. J., You, S., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa7489 · Cited by 90
Multiplexed drug testing of tumor slices using a microfluidic platform
Horowitz, L. F., Rodriguez, A. D., Dereli-Korkut, Z., Lin, R., Castro, K., Mikheev, A. M., Monnat, R. J., Folch, A., & Rostomily, R. C. (2020) · npj Precision Oncology · doi:10.1038/s41698-020-0117-y · Cited by 88
Self-citationParallel microfluidic chemosensitivity testing on individual slice cultures
Chang, T. C., Mikheev, A. M., Huynh, W., Monnat, R. J., Rostomily, R. C., & Folch, A. (2014) · Lab Chip · doi:10.1039/c4lc00642a · Cited by 85
Self-citationPowering ex vivo tissue models in microfluidic systems
McLean, I. C., Schwerdtfeger, L., Tobet, S. A., & Henry, C. S. (2018) · Lab on a Chip · doi:10.1039/c8lc00241j · Cited by 82
Safety in analytical laboratories: basic safety in volumetric analysis
(1977) · Proceedings of the Analytical Division of the Chemical Society · doi:10.1039/ad9771400225 · Cited by 79
A microfluidic platform for functional testing of cancer drugs on intact tumor slices
Rodriguez, A. D., Horowitz, L. F., Castro, K., Kenerson, H., Bhattacharjee, N., Gandhe, G., Raman, A., Monnat, R. J., Yeung, R., Rostomily, R. C., et al. (2020) · Lab on a Chip · doi:10.1039/c9lc00811j · Cited by 77
Self-citationThe end of the era of generosity? Global health amid economic crisis
Schneider, K., & Garrett, L. (2009) · Philosophy Ethics and Humanities in Medicine · doi:10.1186/1747-5341-4-1 · Cited by 67
Serafin, R., Xie, W., Glaser, A. K., & Liu, J. T. C. (2020) · PLoS ONE · doi:10.1371/journal.pone.0233198 · Cited by 64
Self-citationA dynamic microarray device for paired bead-based analysis
Teshima, T., Ishihara, H., Iwai, K., Adachi, A., & Takeuchi, S. (2010) · Lab on a Chip · doi:10.1039/c004986g · Cited by 64
Das, T., Meunier, L., Barbe, L., Provencher, D., Guenat, O., Gervais, T., & Mes-Masson, A.-M. (2013) · Biomicrofluidics · doi:10.1063/1.4774309 · Cited by 56
Multiple Myeloma Cell Drug Responses Differ in Thermoplastic vs PDMS Microfluidic Devices
Moore, T. A., Brodersen, P., & Young, E. W. K. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02351 · Cited by 49
Multi-resolution open-top light-sheet microscopy to enable efficient 3D pathology workflows
Barner, L. A. E., Glaser, A. K., Huang, H., True, L. D., & Liu, J. T. C. (2020) · Biomedical Optics Express · doi:10.1364/boe.408684 · Cited by 49
Self-citationMurry, B. P., Blust, B. E., Singh, A., Foster, T. P., & Marchetti, D. (2006) · Journal of Cellular Biochemistry · doi:10.1002/jcb.20714 · Cited by 47
Suspensory Materials for Surgery of Blepharoptosis: A Systematic Review of Observational Studies
Pacella, E., Mipatrini, D., Pacella, F., Amorelli, G. M., Bottone, A., Smaldone, G., Turchetti, P., & Torre, G. L. (2016) · PLoS ONE · doi:10.1371/journal.pone.0160827 · Cited by 43
Microfluidics for interrogating live intact tissues
Horowitz, L. F., Rodriguez, A. D., Ray, T., & Folch, A. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-020-0164-0 · Cited by 42
Self-citationMeasurement of chemical sludge floc density and implications related to sludge dewatering
Knocke, W. R., Dishman, C. M., & Miller, G. (1993) · Water Environment Research · doi:10.2175/wer.65.6.5 · Cited by 42
Physico-chemical studies on the soluble collagen of rat-tail tendon
Noda, H. (1955) · Biochimica et Biophysica Acta · doi:10.1016/0006-3002(55)90323-1 · Cited by 41
Nash, C. E., Mavria, G., Baxter, E. W., Holliday, D. L., Tomlinson, D. C., Treanor, D. E., Novitskaya, V., Berditchevski, F., Hanby, A. M., & Speirs, V. (2015) · Oncotarget · doi:10.18632/oncotarget.3803 · Cited by 35
Jiang, J., Zhan, J., Yue, W., Yang, M., Yi, C., & Li, C. (2015) · RSC Advances · doi:10.1039/c5ra02220g · Cited by 33
Self-citationSimeone, K., Guay-Lord, R., Lateef, M. A., Péant, B., Kendall‐Dupont, J., Orimoto, A. M., Carmona, E., Provencher, D. M., Saad, F., Gervais, T., et al. (2019) · Lab on a Chip · doi:10.1039/c8lc00982a · Cited by 33
Low Distortion Solvent Bonding of Microfluidic Chips
Ng, S. P., Wiria, F. E., & Tay, N. B. (2016) · Procedia Engineering · doi:10.1016/j.proeng.2015.09.212 · Cited by 31
Solid immersion meniscus lens (SIMlens) for open-top light-sheet microscopy
Barner, L. A. E., Glaser, A. K., True, L. D., Reder, N. P., & Liu, J. T. C. (2019) · Optics Letters · doi:10.1364/ol.44.004451 · Cited by 31
Self-citationA real-time compression library for microscopy imagesPreprint
Balázs, B., Deschamps, J. R., Albert, M., Ries, J., & Hufnagel, L. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/164624 · Cited by 30
Jahnke, H., Poenick, S., Maschke, J., Kendler, M., Simon, J. C., & Robitzki, A. A. (2014) · Cancer Research · doi:10.1158/0008-5472.can-14-0813 · Cited by 29
An emerging role for cytopathology in precision oncology
Pauli, C., Puca, L., Mosquera, J. M., Robinson, B. D., Beltran, H., Rubin, M. A., & Rao, R. A. (2015) · Cancer Cytopathology · doi:10.1002/cncy.21647 · Cited by 29
Jackson, E., McDevitt, T. C., & Lu, H. (2017) · Lab on a Chip · doi:10.1039/c7lc00763a · Cited by 28
Balko, J. M., & Sosman, J. A. (2018) · Cancer Discovery · doi:10.1158/2159-8290.cd-17-1356 · Cited by 17
Astolfi, M., Fartoumi, S., Kataria, S., Sanger, W., Morin, O., Péant, B., Kendall‐Dupont, J., Provencher, D. M., & Gervais, T. (2013) · PolyPublie (École Polytechnique de Montréal) · Cited by 1
Serafin, R., Xie, W., Glaser, A. K., & Liu, J. T. C. (2020) · doi:10.1101/2020.05.03.074955
Self-citation
Research works printed but not linked: 1
- Rodriguez A A microfluidic platform for the delivery of panels of drugs to live tumor slices. Lab Chip 20, 1658– 1675 (2020). 32270149 PMC7679198 · DOI · Paper page
Cited by
Next-generation cancer organoids
LeSavage, B. L., Suhar, R. A., Broguiere, N., Lutolf, M. P., & Heilshorn, S. C. (2022) · Nature Materials · doi:10.1038/s41563-021-01057-5 · Cited by 468
Li, W., Zhou, Z., Zhou, X., Khoo, B. L., Gunawan, R., Chin, Y. R., Zhang, L., Yi, C., Guan, X., & Yang, M. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202202609 · Cited by 119
Self-citationStandardization of organoid culture in cancer research
Zhou, C., Wu, Y., Wang, Z., Liu, Y., Yu, J., Wang, W., Chen, S., Wu, W., Wang, J., Qian, G., et al. (2023) · Cancer Medicine · doi:10.1002/cam4.5943 · Cited by 97
Atat, O. E., Farzaneh, Z., Pourhamzeh, M., Taki, F., Abi‐Habib, R. J., Vosough, M., & El‐Sibai, M. (2021) · Human Cell · doi:10.1007/s13577-021-00642-9 · Cited by 87
“This new platform enabled them to produce large numbers of uniformly-sized cuboids, reduced heterogeneity between samples, facilitated their physical manipulation, and enabled drug screening [118].”
BackgroundCancer-on-a-chip for precision cancer medicine
Liu, L., Wang, H., Chen, R., Song, Y., Wei, W., Baek, D. S. H., Gillin, M., Kurabayashi, K., & Chen, W. (2025) · Lab on a Chip · doi:10.1039/d4lc01043d · Cited by 52
Metadata
- Authors
- Horowitz, L. F., Rodriguez, A. D., Au-Yeung, A., Bishop, K. W., Barner, L. A., Mishra, G., Raman, A., Delgado, P., Liu, J. T. C., Gujral, T. S., Mehrabi, M., Yang, M., Pierce, R. H., & Folch, A.
- Affiliations
- University of Washington (US)
- Department of Bioengineering
- Fred Hutch Cancer Center (US)
- University of Pretoria (ZA)
- City University of Hong Kong (HK)
- Corresponding author
- Horowitz, Lisa F.
- ORCID
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2021
- Volume
- 21
- Issue
- 1
- Pages
- 122-142
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- PMC
- PMC8205430
- OpenAlex
- W3104508445
- Semantic Scholar
- bd303c9eea3f5e1a80a6f72c5d3e675eee4d0204
- Cited by
- 62
- References
- 78
- Citations by year
- 2026: 8 · 2025: 13 · 2024: 13 · 2023: 6 · 2022: 13 · 2021: 9
- FWCI
- 2.20
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- UpSpace Institutional Repository (University of Pretoria) (submittedVersion)
- Funders
- CoMotion, University of Washington
- National Science Foundation (Graduate Research Fellowship Program)
- National Cancer Institute (R01 CA181445)
- Juno Therapeutics
- Research Grants Council, University Grants Committee (CityU_11319516, R1020-18F)
- Consejo Nacional de Ciencia y Tecnología
- DOD Prostate Cancer Research Program (W81XWH-18-10358)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- tissue microdissection, rectangular prism, intact tissue, mouse liver, glioma xenografts, hydrodynamic traps, fluid dynamics simulation, cisplatin, personalized medicine, drug discovery
- MeSH terms
- Animals, Antineoplastic Agents, Drug Evaluation, Preclinical, Pharmaceutical Preparations, Neoplasms, Microfluidics, Microfluidic Analytical Techniques, Mice, Precision Medicine, Tumor Microenvironment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.