The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Position measurement with a resolution and noise-limited instrument
Abstract
A common problem in experimental data analysis is to locate the position of a signal to an accuracy which is substantially less than the actual signal width. By applying maximum likelihood estimation to this problem, this paper derives theoretical limits on the ability to locate signal position. The limiting error in position measurement is shown to be a simple function of the instrument resolution, the density of sample points, and the signal-to-noise ratio of the data. An interesting conclusion is that position information on a much finer scale than the minimum instrument sampling interval is contained in data of modest signal-to-noise ratio. The common procedure of excluding the portion of the data lying below an amplitude threshold to guard against background fluctuations is incorporated in the maximum likelihood analysis. It is shown that selection of the optimum amplitude threshold level depends on the type of noise present in the data, and can be an important factor in position accuracy. The analytical results exhibit close agreement with Monte Carlo simulations of position accuracy in the presence of noise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mathematical Methods in Physics
(2000) · doi:10.1142/4401 · Cited by 819
Parameter estimation in X-ray astronomy
Lampton, M., Margon, B., & Bowyer, S. (1976) · The Astrophysical Journal · doi:10.1086/154592 · Cited by 690
Radiometry and the detection of optical radiation
Boyd, R. W. (1983) · Andalas University Repository (Andalas University) · Cited by 323
Cited by
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Myosin V Walks Hand-Over-Hand: Single Fluorophore Imaging with 1.5-nm Localization
Yildiz, A., Forkey, J. N., McKinney, S. A., Ha, T., Goldman, Y. E., & Selvin, P. R. (2003) · Science · doi:10.1126/science.1084398 · Cited by 1,837
Fluorescent probes for super-resolution imaging in living cells
Fernández-Suárez, M., & Ting, A. Y. (2008) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2531 · Cited by 1,306
Nanometer resolution imaging and tracking of fluorescent molecules with minimal photon fluxes
Balzarotti, F., Eilers, Y., Gwosch, K. C., Gynnå, A. H., Westphal, V., Stefani, F. D., Elf, J., & Hell, S. W. (2017) · Science · doi:10.1126/science.aak9913 · Cited by 1,225
Wide-field subdiffraction imaging by accumulated binding of diffusing probes
Sharonov, A., & Hochstrasser, R. M. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609643104 · Cited by 1,151
Direct stochastic optical reconstruction microscopy with standard fluorescent probes
van de Linde, S., Löschberger, A., Klein, T., Heidbreder, M., Wolter, S., Heilemann, M., & Sauer, M. (2011) · Nature Protocols · doi:10.1038/nprot.2011.336 · Cited by 1,071
Pavani, S. R. P., Thompson, M. A., Biteen, J. S., Lord, S. J., Liu, N., Twieg, R. J., Piestun, R., & Moerner, W. E. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0900245106 · Cited by 1,040
Microscopy and its focal switch
Hell, S. W. (2009) · Nature Methods · doi:10.1038/nmeth.1291 · Cited by 986
Jungmann, R., Steinhauer, C., Scheible, M., Kuzyk, A., Tinnefeld, P., & Simmel, F. C. (2010) · Nano Letters · doi:10.1021/nl103427w · Cited by 903
Optimized localization analysis for single-molecule tracking and super-resolution microscopy
Mortensen, K. I., Churchman, L. S., Spudich, J. A., & Flyvbjerg, H. (2010) · Nature Methods · doi:10.1038/nmeth.1447 · Cited by 871
STED microscopy reveals crystal colour centres with nanometric resolution
Rittweger, E., Han, K. Y., Irvine, S. E., Eggeling, C., & Hell, S. W. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.2 · Cited by 818
Michalet, X. (2010) · Physical Review E · doi:10.1103/physreve.82.041914 · Cited by 721
Localization Accuracy in Single-Molecule Microscopy
Ober, R. J., Ram, S., & Ward, E. S. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74193-4 · Cited by 587
Properties of lipid microdomains in a muscle cell membrane visualized by single molecule microscopy
Schütz, G. J., Kada, G., Pastushenko, V. P., & Schindler, H. (2000) · The EMBO Journal · doi:10.1093/emboj/19.5.892 · Cited by 577
Single-molecule microscopy on model membranes reveals anomalous diffusion
Schütz, G. J., Schindler, H., & Schmidt, T. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78139-6 · Cited by 540
Single Particle Tracking: From Theory to Biophysical Applications
Shen, H., Tauzin, L. J., Baiyasi, R., Wang, W., Moringo, N., Shuang, B., & Landes, C. F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00815 · Cited by 536
Precisely and accurately localizing single emitters in fluorescence microscopy
Deschout, H., Zanacchi, F. C., Mlodzianoski, M., Diaspro, A., Bewersdorf, J., Hess, S. T., & Braeckmans, K. (2014) · Nature Methods · doi:10.1038/nmeth.2843 · Cited by 498
Eckle, P., Smolarski, M., Schlup, P., Biegert, J., Staudte, A., Schöffler, M., Muller, H. G., Dörner, R., & Keller, U. (2008) · Nature Physics · doi:10.1038/nphys982 · Cited by 490
Imaging Live-Cell Dynamics and Structure at the Single-Molecule Level
Liu, Z., Lavis, L. D., & Betzig, E. (2015) · Molecular Cell · doi:10.1016/j.molcel.2015.02.033 · Cited by 486
Quantum theory of superresolution for two incoherent optical point sources
Tsang, M., Nair, R., & Lu, X.-M. (2016) · Physical Review X · doi:10.1103/physrevx.6.031033 · Cited by 482
Proposed method for molecular optical imaging
Betzig, E. (1995) · Optics Letters · doi:10.1364/ol.20.000237 · Cited by 444
Dynamic Superresolution Imaging of Endogenous Proteins on Living Cells at Ultra-High Density
Giannone, G., Hosy, E., Levet, F., Constals, A., Schulze, K., Sobolevsky, A. I., Rosconi, M. P., Gouaux, E., Tampé, R., Choquet, D., et al. (2010) · Biophysical Journal · doi:10.1016/j.bpj.2010.06.005 · Cited by 416
High-resolution Fourier-transform infrared chemical imaging with multiple synchrotron beams
Nasse, M. J., Walsh, M. J., Mattson, E. C., Reininger, R., Kajdacsy-Balla, A., Macias, V., Bhargava, R., & Hirschmugl, C. J. (2011) · Nature Methods · doi:10.1038/nmeth.1585 · Cited by 349
Fluorophore localization algorithms for super-resolution microscopy
Small, A., & Stahlheber, S. (2014) · Nature Methods · doi:10.1038/nmeth.2844 · Cited by 349
Subnanometre single-molecule localization, registration and distance measurements
Pertsinidis, A., Zhang, Y., & Chu, S. (2010) · Nature · doi:10.1038/nature09163 · Cited by 342
The Membrane Skeleton Controls Diffusion Dynamics and Signaling through the B Cell Receptor
Treanor, B., Depoil, D., Gonzalez-Granja, A., Barral, P., Weber, M., Dushek, O., Bruckbauer, A., & Batista, F. D. (2010) · Immunity · doi:10.1016/j.immuni.2009.12.005 · Cited by 317
Ortega-Arroyo, J., & Kukura, P. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp41013c · Cited by 293
Ultrahigh-resolution multicolor colocalization of single fluorescent probes
Lacoste, T. D., Michalet, X., Pinaud, F., Chemla, D. S., Alivisatos, A. P., & Weiss, S. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.170286097 · Cited by 285
Fluorescence Nanoscopy in Whole Cells by Asynchronous Localization of Photoswitching Emitters
Egner, A., Geisler, C., von Middendorff, C., Bock, H., Wenzel, D., Medda, R., Andresen, M., Stiel, A. C., Jakobs, S., Eggeling, C., et al. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.112201 · Cited by 284
Advances in Light Microscopy for Neuroscience
Wilt, B. A., Burns, L. D., Wei Ho, E. T., Ghosh, K. K., Mukamel, E. A., & Schnitzer, M. J. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135540 · Cited by 278
3‐D PSF fitting for fluorescence microscopy: implementation and localization application
KIRSHNER, H., AGUET, F., SAGE, D., & UNSER, M. (2013) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03675.x · Cited by 277
Meridional flow of small photospheric magnetic features
Komm, R. W., Howard, R. F., & Harvey, J. W. (1993) · Solar Physics · doi:10.1007/bf00690713 · Cited by 265
Lipid diffusion in planar membranes investigated by fluorescence correlation spectroscopy
Macháň, R., & Hof, M. (2010) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2010.02.014 · Cited by 259
Endesfelder, U., Malkusch, S., Fricke, F., & Heilemann, M. (2014) · Histochemistry and Cell Biology · doi:10.1007/s00418-014-1192-3 · Cited by 259
Multicolor Far-Field Fluorescence Nanoscopy through Isolated Detection of Distinct Molecular Species
Bossi, M., Fölling, J., Belov, V. N., Boyarskiy, V. P., Medda, R., Egner, A., Eggeling, C., Schönle, A., & Hell, S. W. (2008) · Nano Letters · doi:10.1021/nl801471d · Cited by 253
Kulzer, F., & Orrit, M. (2004) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.54.011002.103816 · Cited by 252
‘MINFLUX monitors rapid molecular jumps with superior spatiotemporal resolution’
Eilers, Y., Ta, H., Gwosch, K. C., Balzarotti, F., & Hell, S. W. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1801672115 · Cited by 188
Single-molecule spectroscopy and imaging over the decades
Moerner, W. E., Shechtman, Y., & Wang, Q. (2015) · Faraday Discussions · doi:10.1039/c5fd00149h · Cited by 103
Urashima, S.-H., Nishioka, T., & Yui, H. (2022) · Analytical Sciences · doi:10.1007/s44211-022-00119-1 · Cited by 17
Metadata
- Authors
- Bobroff, N.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1986-06-01
- Volume
- 57
- Issue
- 6
- Pages
- 1152-1157
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2090897377
- Cited by
- 375
- References
- 3
- FWCI
- 3.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.