The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Calibration of frictional forces in atomic force microscopy
Abstract
The atomic force microscope can provide information on the atomic-level frictional properties of surfaces, but reproducible quantitative measurements are difficult to obtain. Parameters that are either unknown or difficult to precisely measure include the normal and lateral cantilever force constants (particularly with microfabricated cantilevers), the tip height, the deflection sensor response, and the tip structure and composition at the tip-surface contact. We present an in situ experimental procedure to determine the response of a cantilever to lateral forces in terms of its normal force response. This procedure is quite general. It will work with any type of deflection sensor and does not require the knowledge or direct measurement of the lever dimensions or the tip height. In addition, the shape of the tip apex can be determined. We also discuss a number of specific issues related to force and friction measurements using optical lever deflection sensing. We present experimental results on the lateral force response of commercially available V-shaped cantilevers. Our results are consistent with estimates of lever mechanical properties using continuum elasticity theory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Timoshenko, S. P., & Goodier, J. N. (1934) · Virtual Defense Library (Ministerio de Defensa) · Cited by 13,717
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Theory of Elasticity (3rd ed.)
Timoshenko, S. P., Goodier, J. N., & Abramson, H. N. (1970) · Journal of Applied Mechanics · doi:10.1115/1.3408648 · Cited by 4,021
Atomic-scale friction of a tungsten tip on a graphite surface
Mate, C. M., McClelland, G. M., Erlandsson, R., & Chiang, S. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.1942 · Cited by 1,763
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Calculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Method for the calibration of atomic force microscope cantilevers
Sader, J. E., Larson, I., Mulvaney, P., & White, L. R. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145439 · Cited by 1,000
Fundamentals of Friction: Macroscopic and Microscopic Processes
(1992) · Springer eBooks · doi:10.1007/978-94-011-2811-7 · Cited by 613
Meyer, G., & Amer, N. M. (1990) · Applied Physics Letters · doi:10.1063/1.103950 · Cited by 587
Cited by
Scratching the Surface: Fundamental Investigations of Tribology with Atomic Force Microscopy
Carpick, R. W., & Salmeron, M. (1997) · Chemical Reviews · doi:10.1021/cr960068q · Cited by 1,126
Self-citationNormal and torsional spring constants of atomic force microscope cantilevers
Green, C. P., Lioe, H., Cleveland, J. P., Proksch, R., Mulvaney, P., & Sader, J. E. (2004) · Review of Scientific Instruments · doi:10.1063/1.1753100 · Cited by 551
Robust microscale superlubricity in graphite/hexagonal boron nitride layered heterojunctions
Song, Y., Mandelli, D., Hod, O., Urbakh, M., Ma, M., & Zheng, Q. (2018) · Nature Materials · doi:10.1038/s41563-018-0144-z · Cited by 494
Noy, A., Vezenov, D. V., & Lieber, C. M. (1997) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.27.1.381 · Cited by 478
Riboh, J. C., Haes, A. J., McFarland, A. D., Ranjit Yonzon, C., & Van Duyne, R. P. (2003) · The Journal of Physical Chemistry B · doi:10.1021/jp022130v · Cited by 475
Recent advances in single-asperity nanotribology
Szlufarska, I., Chandross, M., & Carpick, R. W. (2008) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/41/12/123001 · Cited by 470
Self-citationCarpick, R. W., Ogletree, D. F., & Salmeron, M. (1997) · Applied Physics Letters · doi:10.1063/1.118639 · Cited by 432
Self-citationAn improved wedge calibration method for lateral force in atomic force microscopy
Varenberg, M., Etsion, I., & Halperin, G. (2003) · Review of Scientific Instruments · doi:10.1063/1.1584082 · Cited by 427
Lio, A., Charych, D. H., & Salmeron, M. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp963918e · Cited by 286
Self-citationFundamental Aspects of Energy Dissipation in Friction
Park, J. Y., & Salmeron, M. (2014) · Chemical Reviews · doi:10.1021/cr200431y · Cited by 272
Self-citationChemical and Biochemical Analysis Using Scanning Force Microscopy
Takano, H., Kenseth, J. R., Wong, S.-S., O'Brie, J. C., & Porter, M. D. (1999) · Chemical Reviews · doi:10.1021/cr9801317 · Cited by 259
Lateral force calibration of an atomic force microscope with a diamagnetic levitation spring system
Li, Q., Kim, K.-S., & Rydberg, A. (2006) · Review of Scientific Instruments · doi:10.1063/1.2209953 · Cited by 208
J. Phys.: Condens. Matter, 13, 619
(2001) · Journal of Physics Condensed Matter · doi:10.1088/0953-8984/13/31/202 · Cited by 206
Müller, M. T., Yan, X., Lee, S., Perry, S. S., & Spencer, N. D. (2005) · Macromolecules · doi:10.1021/ma047468x · Cited by 86
Bennewitz, R. (2005) · Materials Today · doi:10.1016/s1369-7021(05)00845-x · Cited by 60
Mullin, N., & Hobbs, J. K. (2014) · Review of Scientific Instruments · doi:10.1063/1.4901221 · Cited by 58
The mechanics of nanometre-scale molecular contacts
Busuttil, K., Nikogeorgos, N., Zhang, Z., Geoghegan, M., Hunter, C. A., & Leggett, G. J. (2012) · Faraday Discussions · doi:10.1039/c2fd00133k · Cited by 16
Metadata
- Authors
- Ogletree, D. F., Carpick, R. W., & Salmeron, M.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1996-09-01
- Volume
- 67
- Issue
- 9
- Pages
- 3298-3306
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2021216663
- Cited by
- 604
- References
- 20
- FWCI
- 10.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.