The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Sub-attonewton force detection at millikelvin temperatures
Abstract
A 290-nm-thick single-crystal silicon cantilever has been cooled in vacuum to a temperature of 110 mK in order reduce its thermal motion and thereby improve the achievable force resolution. Since the thermal conductivity of the silicon cantilever is extremely low at millikelvin temperatures, an improved optical fiber interferometer was developed to measure the subangstrom thermal motion with optical powers as low as 2 nW. At the lowest temperature, the cantilever exhibited a quality factor of 150 000 and achieved a noise temperature of 220 mK, with a corresponding force noise of 820 zN in a 1 Hz bandwidth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
The hierarchy problem and new dimensions at a millimeter
Arkani–Hamed, N., Dimopoulos, S., & Dvali, G. (1998) · Physics Letters B · doi:10.1016/s0370-2693(98)00466-3 · Cited by 6,563
Precision Measurement of the Casimir Force from 0.1 to0.9μm
Mohideen, U., & Roy, A. (1998) · Physical Review Letters · doi:10.1103/physrevlett.81.4549 · Cited by 1,199
Quality factors in micron- and submicron-thick cantilevers
Yasumura, K. Y., Stowe, T. D., Chow, E. M., Pfafman, T. E., Kenny, T. W., Stipe, B. C., & Rugar, D. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.825786 · Cited by 688
Self-citationImproved fiber-optic interferometer for atomic force microscopy
Rugar, D., Mamin, H. J., & Guethner, P. (1989) · Applied Physics Letters · doi:10.1063/1.101987 · Cited by 629
Self-citationMagnetic resonance force microscopy
Sidles, J. A., Garbini, J. L., Bruland, K. J., Rugar, D., Züger, O., Hoen, S., & Yannoni, C. S. (1995) · Reviews of Modern Physics · doi:10.1103/revmodphys.67.249 · Cited by 466
Self-citationAttonewton force detection using ultrathin silicon cantilevers
Stowe, T. D., Yasumura, K., Kenny, T. W., Botkin, D., Wago, K., & Rugar, D. (1997) · Applied Physics Letters · doi:10.1063/1.119522 · Cited by 390
Self-citationPhonon-boundary scattering in thin silicon layers
Asheghi, M., Leung, Y. K., Wong, S. S., & Goodson, K. E. (1997) · Applied Physics Letters · doi:10.1063/1.119402 · Cited by 337
Surface effects and high quality factors in ultrathin single-crystal silicon cantilevers
Yang, J., Ono, T., & Esashi, M. (2000) · Applied Physics Letters · doi:10.1063/1.1330225 · Cited by 171
Sidles, J. A. (1992) · Physical Review Letters · doi:10.1103/physrevlett.68.1124 · Cited by 139
Cited by
A tunable carbon nanotube electromechanical oscillator
Sazonova, V., Yaish, Y., Üstünel, H., Roundy, D., Arias, T. A., & McEuen, P. L. (2004) · Nature · doi:10.1038/nature02905 · Cited by 1,312
Cantilever transducers as a platform for chemical and biological sensors
Lavrik, N. V., Sepaniak, M. J., & Datskos, P. G. (2004) · Review of Scientific Instruments · doi:10.1063/1.1763252 · Cited by 1,117
An atomic-resolution nanomechanical mass sensor
Jensen, K., Kim, K., & Zettl, A. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.200 · Cited by 1,053
Performance of monolayer graphene nanomechanical resonators with electrical readout
Chen, C., Rosenblatt, S., Bolotin, K. I., Kalb, W., Kim, P., Kymissis, I., Stormer, H. L., Heinz, T. F., & Hone, J. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.267 · Cited by 987
Towards quantum superpositions of a mirror
Marshall, W., Simon, C., Penrose, R., & Bouwmeester, D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.130401 · Cited by 960
Near-field radiative heat transfer and noncontact friction
Volokitin, A. I., & Persson, B. N. J. (2007) · Reviews of Modern Physics · doi:10.1103/revmodphys.79.1291 · Cited by 768
Nonlinear damping in mechanical resonators made from carbon nanotubes and graphene
Eichler, A., Moser, J., Chaste, J., Zdrojek, M., Wilson-Rae, I., & Bachtold, A. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.71 · Cited by 669
Sub-kelvin optical cooling of a micromechanical resonator
Kleckner, D., & Bouwmeester, D. (2006) · Nature · doi:10.1038/nature05231 · Cited by 664
Nanometre-scale displacement sensing using a single electron transistor
Knobel, R. G., & Cleland, A. N. (2003) · Nature · doi:10.1038/nature01773 · Cited by 599
Cavity opto-mechanics using an optically levitated nanosphere
Chang, D. E., Regal, C. A., Papp, S. B., Wilson, D. J., Ye, J., Painter, O., Kimble, H. J., & Zoller, P. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0912969107 · Cited by 596
Measuring nanomechanical motion with a microwave cavity interferometer
Regal, C. A., Teufel, J. D., & Lehnert, K. W. (2008) · Nature Physics · doi:10.1038/nphys974 · Cited by 500
Nanoscale magnetic resonance imaging
Degen, C. L., Poggio, M., Mamin, H. J., Rettner, C. T., & Rugar, D. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0812068106 · Cited by 499
Self-citationNanomechanical motion measured with an imprecision below that at the standard quantum limit
Teufel, J. D., Donner, T., Castellanos-Beltran, M. A., Harlow, J. W., & Lehnert, K. W. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.343 · Cited by 499
Eom, K., Park, H. S., Yoon, D. S., & Kwon, T. (2011) · Physics Reports · doi:10.1016/j.physrep.2011.03.002 · Cited by 464
A hybrid on-chip optomechanical transducer for ultrasensitive force measurements
Gavartin, E., Verlot, P., & Kippenberg, T. J. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.97 · Cited by 439
Ultrasensitive force detection with a nanotube mechanical resonator
Moser, J., Güttinger, J., Eichler, A., Esplandiu, M. J., Liu, D. E., Dykman, M. I., & Bachtold, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2013.97 · Cited by 404
Quantum electromechanical systems
Blencowe, M. (2004) · Physics Reports · doi:10.1016/j.physrep.2003.12.005 · Cited by 376
Single-crystal diamond nanomechanical resonators with quality factors exceeding one million
Tao, Y., Boss, J. M., Moores, B. A., & Degen, C. L. (2014) · Nature Communications · doi:10.1038/ncomms4638 · Cited by 358
Femtogram mass detection using photothermally actuated nanomechanical resonators
Lavrik, N. V., & Datskos, P. G. (2003) · Applied Physics Letters · doi:10.1063/1.1569050 · Cited by 308
Quantum optomechanics—throwing a glance [Invited]
Aspelmeyer, M., Gröblacher, S., Hammerer, K., & Kiesel, N. (2010) · Journal of the Optical Society of America B · doi:10.1364/josab.27.00a189 · Cited by 280
Dissipation in nanoelectromechanical systems
Imboden, M., & Mohanty, P. (2014) · Physics Reports · doi:10.1016/j.physrep.2013.09.003 · Cited by 273
A review on coupled MEMS resonators for sensing applications utilizing mode localization
Zhao, C., Montaseri, M. H., Wood, G. S., Pu, S. H., Seshia, A. A., & Kraft, M. (2016) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2016.07.015 · Cited by 265
Ultrasensitive detection of force and displacement using trapped ions
Biercuk, M. J., Uys, H., Britton, J. W., VanDevender, A. P., & Bollinger, J. J. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.165 · Cited by 180
Metadata
- Authors
- Mamin, H. J., & Rugar, D.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2001-11-12
- Volume
- 79
- Issue
- 20
- Pages
- 3358-3360
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1970737244
- Cited by
- 439
- References
- 12
- FWCI
- 12.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.