The DOI matches its Crossref record; 109 of the 109 references it cites were found in a registry or an index.
Protein immobilization techniques for microfluidic assays
Open accessAbstract
Microfluidic systems have shown unequivocal performance improvements over conventional bench-top assays across a range of performance metrics. For example, specific advances have been made in reagent consumption, throughput, integration of multiple assay steps, assay automation, and multiplexing capability. For heterogeneous systems, controlled immobilization of reactants is essential for reliable, sensitive detection of analytes. In most cases, protein immobilization densities are maximized, while native activity and conformation are maintained. Immobilization methods and chemistries vary significantly depending on immobilization surface, protein properties, and specific assay goals. In this review, we present trade-offs considerations for common immobilization surface materials. We overview immobilization methods and chemistries, and discuss studies exemplar of key approaches—here with a specific emphasis on immunoassays and enzymatic reactors. Recent “smart immobilization” methods including the use of light, electrochemical, thermal, and chemical stimuli to attach and detach proteins on demand with precise spatial control are highlighted. Spatially encoded protein immobilization using DNA hybridization for multiplexed assays and reversible protein immobilization surfaces for repeatable assay are introduced as immobilization methods. We also describe multifunctional surface coatings that can perform tasks that were, until recently, relegated to multiple functional coatings. We consider the microfluidics literature from 1997 to present and close with a perspective on future approaches to protein immobilization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Hydrogels for tissue engineering: scaffold design variables and applications
Drury, J. L., & Mooney, D. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00340-5 · Cited by 5,136
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Silicon as a mechanical material
Petersen, K. E. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12331 · Cited by 2,902
Printing Proteins as Microarrays for High-Throughput Function Determination
MacBeath, G., & Schreiber, S. L. (2000) · Science · doi:10.1126/science.289.5485.1760 · Cited by 2,767
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Biomarkers in Cancer Staging, Prognosis and Treatment Selection
Ludwig, J. A., & Weinstein, J. N. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1739 · Cited by 1,666
A gas chromatographic air analyzer fabricated on a silicon wafer
Terry, S. C., Jerman, J. H., & Angell, J. B. (1979) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1979.19791 · Cited by 1,452
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
Capillary electrophoresis and sample injection systems integrated on a planar glass chip
Harrison, D. J., Manz, A., Fan, Z., Luedi, H., & Widmer, H. M. (1992) · Analytical Chemistry · doi:10.1021/ac00041a030 · Cited by 1,226
Becker, H. (2002) · Talanta · doi:10.1016/s0039-9140(01)00594-x · Cited by 1,187
Commercialization of microfluidic point-of-care diagnostic devices
Chin, C. D., Linder, V., & Sia, S. K. (2012) · Lab on a Chip · doi:10.1039/c2lc21204h · Cited by 1,124
Enzymes for chemical synthesis
Koeller, K. M., & Wong, C.-H. (2001) · Nature · doi:10.1038/35051706 · Cited by 894
Protein Immobilization Strategies for Protein Biochips
Rusmini, F., Zhong, Z., & Feijen, J. (2007) · Biomacromolecules · doi:10.1021/bm061197b · Cited by 869
Protein microarrays and proteomics
MacBeath, G. (2002) · Nature Genetics · doi:10.1038/ng1037 · Cited by 846
A perspective on paper-based microfluidics: Current status and future trends
Li, X., Ballerini, D. R., & Shen, W. (2012) · Biomicrofluidics · doi:10.1063/1.3687398 · Cited by 813
Lab-on-a-chip devices for global health: Past studies and future opportunities
Chin, C. D., Linder, V., & Sia, S. K. (2007) · Lab Chip · doi:10.1039/b611455e · Cited by 811
Polymer microfabrication methods for microfluidic analytical applications
Becker, H., & Gärtner, C. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<12::aid-elps12>3.0.co;2-7 · Cited by 795
Ramsay, G. (1998) · Nature Biotechnology · doi:10.1038/nbt0198-40 · Cited by 781
Multiplexed protein measurement: technologies and applications of protein and antibody arrays
Kingsmore, S. F. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd2006 · Cited by 715
Aptamers come of age – at last
Bunka, D. H. J., & Stockley, P. G. (2006) · Nature Reviews Microbiology · doi:10.1038/nrmicro1458 · Cited by 695
Patterned Delivery of Immunoglobulins to Surfaces Using Microfluidic Networks
Delamarche, E., Bernard, A., Schmid, H., Michel, B., & Biebuyck, H. (1997) · Science · doi:10.1126/science.276.5313.779 · Cited by 678
Components for integrated poly(dimethylsiloxane) microfluidic systems
Ng, J. M. K., Gitlin, I., Stroock, A. D., & Whitesides, G. M. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200210)23:20<3461::aid-elps3461>3.0.co;2-8 · Cited by 626
Aldehyde-agarose gels as activated supports for immobilization-stabilization of enzymes
Guisán, J. (1988) · Enzyme and Microbial Technology · doi:10.1016/0141-0229(88)90018-x · Cited by 602
Rapid, electrostatically assisted association of proteins
Schreiber, G., & Fersht, A. R. (1996) · Nature Structural Biology · doi:10.1038/nsb0596-427 · Cited by 559
Clinical proteomics: translating benchside promise into bedside reality
Petricoin, E. F., Zoon, K. C., Kohn, E. C., Barrett, J. C., & Liotta, L. A. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd891 · Cited by 550
A fully integrated microfluidic genetic analysis system with sample-in–answer-out capability
Easley, C. J., Karlinsey, J. M., Bienvenue, J. M., Legendre, L. A., Roper, M. G., Feldman, S. H., Hughes, M. A., Hewlett, E. L., Merkel, T. J., Ferrance, J. P., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604663103 · Cited by 547
Programmed Adsorption and Release of Proteins in a Microfluidic Device
Huber, D. L., Manginell, R. P., Samara, M. A., Kim, B.-I., & Bunker, B. C. (2003) · Science · doi:10.1126/science.1080759 · Cited by 530
Chiu, D. T., Jeon, N. L., Huang, S., Kane, R. S., Wargo, C. J., Choi, I. S., Ingber, D. E., & Whitesides, G. M. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040562297 · Cited by 526
Bernard, A., Delamarche, E., Schmid, H., Michel, B., Bosshard, H. R., & Biebuyck, H. (1998) · Langmuir · doi:10.1021/la980037l · Cited by 518
Membranes and microfluidics: a review
de Jong, J., Lammertink, R. G. H., & Wessling, M. (2006) · Lab on a Chip · doi:10.1039/b603275c · Cited by 483
Gershoni, J. M., & Palade, G. E. (1982) · Analytical Biochemistry · doi:10.1016/0003-2697(82)90056-2 · Cited by 424
Multiplexed Detection of Protein Cancer Markers with Biobarcoded Nanoparticle Probes
Stoeva, S. I., Lee, J.-S., Smith, J. E., Rosen, S. T., & Mirkin, C. A. (2006) · Journal of the American Chemical Society · doi:10.1021/ja0613106 · Cited by 419
Microfluidic Networks for Chemical Patterning of Substrates: Design and Application to Bioassays
Delamarche, E., Bernard, A., Schmid, H., Bietsch, A., Michel, B., & Biebuyck, H. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973071f · Cited by 412
Microfluidic immunoassays as rapid saliva-based clinical diagnostics
Herr, A. E., Hatch, A. V., Throckmorton, D. J., Tran, H. M., Brennan, J. S., Giannobile, W. V., & Singh, A. K. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607254104 · Cited by 389
Self-citationChoi, J.-W., Oh, K. W., Thomas, J. H., Heineman, W. R., Halsall, H. B., Nevin, J. H., Helmicki, A. J., Henderson, H. T., & Ahn, C. H. (2002) · Lab on a Chip · doi:10.1039/b107540n · Cited by 364
Microfluidic tectonics: A comprehensive construction platform for microfluidic systems
Beebe, D. J., Moore, J. S., Yu, Q., Liu, R. H., Kraft, M. L., Jo, B.-H., & Devadoss, C. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.250273097 · Cited by 353
Aqueous Sol−Gel Process for Protein Encapsulation
Bhatia, R. B., Brinker, C. J., Gupta, A. K., & Singh, A. K. (2000) · Chemistry of Materials · doi:10.1021/cm000260f · Cited by 352
Peterson, D. S., Rohr, T., Svec, F., & Fréchet, J. M. J. (2002) · Analytical Chemistry · doi:10.1021/ac020180q · Cited by 345
Immunoassays in microfluidic systems
Ng, A. H. C., Uddayasankar, U., & Wheeler, A. R. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3678-8 · Cited by 345
Microfluidics without pumps: reinventing the T-sensor and H-filter in paper networks
Osborn, J. L., Lutz, B., Fu, E., Kauffman, P., Stevens, D. Y., & Yager, P. (2010) · Lab on a Chip · doi:10.1039/c004821f · Cited by 338
Niemeyer, C. M., Sano, T., Smith, C. L., & Cantor, C. R. (1994) · Nucleic Acids Research · doi:10.1093/nar/22.25.5530 · Cited by 335
Yakovleva, J., Davidsson, R., Lobanova, A., Bengtsson, M., Eremin, S., Laurell, T., & Emnéus, J. (2002) · Analytical Chemistry · doi:10.1021/ac015645b · Cited by 330
Antibodies in diagnostics – from immunoassays to protein chips
Borrebaeck, C. A. K. (2000) · Immunology Today · doi:10.1016/s0167-5699(00)01683-2 · Cited by 324
Enzyme technology: an overview
Beilen, J. B. V., & Li, Z. (2002) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00334-8 · Cited by 320
An Integrated Approach to a Portable and Low‐Cost Immunoassay for Resource‐Poor Settings
Sia, S. K., Linder, V., Parviz, B. A., Siegel, A., & Whitesides, G. M. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200353016 · Cited by 292
Bousse, L., Mouradian, S., Minalla, A., Yee, H., Williams, K., & Dubrow, R. (2001) · Analytical Chemistry · doi:10.1021/ac0012492 · Cited by 283
Bailey, R. C., Kwong, G. A., Radu, C. G., Witte, O. N., & Heath, J. R. (2007) · Journal of the American Chemical Society · doi:10.1021/ja065930i · Cited by 272
Hu, M., Yan, J., He, Y., Lu, H., Weng, L., Song, S., Fan, C., & Wang, L. (2010) · ACS Nano · doi:10.1021/nn901404h · Cited by 258
Gao, J., Xu, J., Locascio, L. E., & Lee, C. S. (2001) · Analytical Chemistry · doi:10.1021/ac001126h · Cited by 257
Solution-Phase Surface Modification in Intact Poly(dimethylsiloxane) Microfluidic Channels
Sui, G., Wang, J., Lee, C.-C., Lu, W., Lee, S. P., Leyton, J. V., Wu, A. M., & Tseng, H.-R. (2006) · Analytical Chemistry · doi:10.1021/ac060605z · Cited by 238
Design and Characterization of Immobilized Enzymes in Microfluidic Systems
Mao, H., Yang, T., & Cremer, P. S. (2002) · Analytical Chemistry · doi:10.1021/ac010822u · Cited by 235
Integrated Microanalytical Technology Enabling Rapid and Automated Protein Identification
Ekström, S., Önnerfjord, P., Nilsson, J., Bengtsson, M., Laurell, T., & Marko‐Varga, G. (1999) · Analytical Chemistry · doi:10.1021/ac990731l · Cited by 231
Surface enhanced Raman spectroscopy and its application to molecular and cellular analysis
Huh, Y. S., Chung, A. J., & Erickson, D. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0392-3 · Cited by 217
Oligohis‐tags: mechanisms of binding to Ni2+‐NTA surfaces
Knecht, S., Ricklin, D., Eberle, A. N., & Ernst, B. (2009) · Journal of Molecular Recognition · doi:10.1002/jmr.941 · Cited by 209
Microchannel enzyme reactors and their applications for processing
Miyazaki, M., & Maeda, H. (2006) · Trends in biotechnology · doi:10.1016/j.tibtech.2006.08.002 · Cited by 204
Wang, C., Oleschuk, R., Ouchen, F., Li, J., Thibault, P., & Harrison, D. J. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/1097-0231(20000815)14:15<1377::aid-rcm31>3.0.co;2-2 · Cited by 204
Dodge, A., Fluri, K., Verpoorte, E., & de Rooij, N. F. (2001) · Analytical Chemistry · doi:10.1021/ac0015366 · Cited by 199
Isoelectric focusing technology quantifies protein signaling in 25 cells
O'Neill, R. A., Bhamidipati, A., Bi, X., Deb-Basu, D., Cahill, L., Ferrante, J., Gentalen, E., Glazer, M., Gossett, J., Hacker, K., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607973103 · Cited by 194
Wolf, M., Juncker, D., Michel, B., Hunziker, P., & Delamarche, E. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.11.003 · Cited by 193
Efficient Mixing and Reactions within Microfluidic Channels Using Microbead-Supported Catalysts
Seong, G. H., & Crooks, R. M. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020932y · Cited by 193
He, Y., Lu, H.-T., Sai, L.-M., Lai, W.-Y., Fan, Q.-L., Wang, L.-H., & Huang, W. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp057498h · Cited by 192
Chen, T., Embree, H. D., Wu, L., & Payne, G. F. (2002) · Biopolymers · doi:10.1002/bip.10196 · Cited by 184
Wang, Y.-C., & Han, J. (2008) · Lab on a Chip · doi:10.1039/b717220f · Cited by 182
Linder, V., Verpoorte, E., Thormann, W., de Rooij, N. F., & Sigrist, H. (2001) · Analytical Chemistry · doi:10.1021/ac010421e · Cited by 173
Liu, P., Li, X., Greenspoon, S. A., Scherer, J. R., & Mathies, R. A. (2011) · Lab on a Chip · doi:10.1039/c0lc00533a · Cited by 169
Enzyme-Immobilized Microfluidic Process Reactors
Asanomi, Y., Yamaguchi, H., Miyazaki, M., & Maeda, H. (2011) · Molecules · doi:10.3390/molecules16076041 · Cited by 164
Hydrogel-Based Microreactors as a Functional Component of Microfluidic Systems
Zhan, W., Seong, G. H., & Crooks, R. M. (2002) · Analytical Chemistry · doi:10.1021/ac020340y · Cited by 163
Hughes, A. J., & Herr, A. E. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1207754110 · Cited by 161
Self-citationElectrospun Nanofibrous Membranes: A Novel Solid Substrate for Microfluidic Immunoassays for HIV
Yang, D., Niu, X., Liu, Y., Wang, Y., Gu, X., Song, L., Zhao, R., Ma, L., Shao, Y., & Jiang, X. (2008) · Advanced Materials · doi:10.1002/adma.200801302 · Cited by 160
An in vitro microfluidic approach to generating protein-interaction networks
Gerber, D., Maerkl, S. J., & Quake, S. R. (2008) · Nature Methods · doi:10.1038/nmeth.1289 · Cited by 151
Use of chicken antibodies in enzyme immunoassays to avoid interference by rheumatoid factors
Larsson, A. O., Karlsson‐Parra, A., & Sjöquist, J. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.3.411 · Cited by 138
Label-free technologies for quantitative multiparameter biological analysis
Qavi, A. J., Washburn, A. L., Byeon, J.-Y., & Bailey, R. C. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2637-8 · Cited by 138
Parallel microfluidic surface plasmon resonance imaging arrays
Ouellet, E., Lausted, C. G., Lin, T., Yang, C. W. T., Hood, L., & Lagally, E. T. (2010) · Lab on a Chip · doi:10.1039/b920589f · Cited by 135
Covalent Micropatterning of Poly(dimethylsiloxane) by Photografting through a Mask
Wang, Y., Lai, H., Bachman, M., Sims, C. E., Li, G. P., & Allbritton, N. L. (2005) · Analytical Chemistry · doi:10.1021/ac0509915 · Cited by 133
Silane–dextran chemistry on lateral flow polymer chips for immunoassays
Jönsson, C., Aronsson, M., Rundström, G., Pettersson, C., Mendel-Hartvig, I., Bakker, J. W. P., Martinsson, E., Liedberg, B., MacCraith, B. D., Öhman, O., et al. (2008) · Lab on a Chip · doi:10.1039/b800297e · Cited by 132
Enzyme-catalyzed processes in pharmaceutical industry
Rasor, J. P., & Voß, E. (2001) · Applied Catalysis A General · doi:10.1016/s0926-860x(01)00804-3 · Cited by 128
Belder, D., Deege, A., Husmann, H., Kohler, F., & Ludwig, M. (2001) · Electrophoresis · Cited by 122
Development of Macroporous Poly(ethylene glycol) Hydrogel Arrays within Microfluidic Channels
Lee, A. G., Arena, C. P., Beebe, D. J., & Palecek, S. P. (2010) · Biomacromolecules · doi:10.1021/bm100792y · Cited by 119
Bhattacharyya, A., & Klapperich, C. M. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-9026-2 · Cited by 111
Quantitative proteomics: assessing the spectrum of in-gel protein detection methods
Gauci, V. J., Wright, E. P., & Coorssen, J. R. (2010) · Journal of Chemical Biology · doi:10.1007/s12154-010-0043-5 · Cited by 108
Microfluidic integration for automated targeted proteomic assays
Hughes, A. J., Lin, R., Peehl, D. M., & Herr, A. E. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1108617109 · Cited by 104
Self-citationImmobilization of multi-enzyme microreactors inside microfluidic devices
Koh, W., & Pishko, M. V. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.08.025 · Cited by 103
An integrated microfluidic system for C-reactive protein measurement
Yang, Y.-N., Lin, H.-I., Wang, J.-H., Shiesh, S., & Lee, G. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.03.034 · Cited by 96
Photopolymerized Cross-Linked Polyacrylamide Gels for On-Chip Protein Sizing
Herr, A. E., & Singh, A. K. (2004) · Analytical Chemistry · doi:10.1021/ac049686u · Cited by 93
Self-citationHuman Tear Protein Analysis Enabled by an Alkaline Microfluidic Homogeneous Immunoassay
Karns, K., & Herr, A. E. (2011) · Analytical Chemistry · doi:10.1021/ac202061v · Cited by 89
Self-citationAutomated microfluidic protein immunoblotting
He, M., & Herr, A. E. (2010) · Nature Protocols · doi:10.1038/nprot.2010.142 · Cited by 89
Self-citationReview: Aptamers in microfluidic chips
Xu, Y., Yang, X., & Wang, E. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.10.007 · Cited by 88
Zhang, S. (2004) · Nature Materials · doi:10.1038/nmat1047 · Cited by 82
Chitosan-mediated in situ biomolecule assembly in completely packaged microfluidic devices
Park, J. J., Luo, X., Yi, H., Valentine, T. M., Payne, G. F., Bentley, W. E., Reza Ghodssi, A., & Rubloff, G. W. (2006) · Lab on a Chip · doi:10.1039/b603101c · Cited by 80
Li, Y., Xu, X., Yan, B., et al. (2007) · Journal of Proteome Research · doi:10.1021/pr060558r · Cited by 79
“Smart” mobile affinity matrix for microfluidic immunoassays
Malmstadt, N., Hoffman, A. S., & Stayton, P. S. (2004) · Lab on a Chip · doi:10.1039/b315394k · Cited by 77
Patterning Multiplex Protein Microarrays in a Single Microfluidic Channel
Didar, T. F., Foudeh, A. M., & Tabrizian, M. (2011) · Analytical Chemistry · doi:10.1021/ac2025877 · Cited by 68
Mass spectrometric imaging of peptide release from neuronal cells within microfluidic devices
Jo, K., Heien, M. L., Thompson, L. B., Zhong, M., Nuzzo, R. G., & Sweedler, J. V. (2007) · Lab on a Chip · doi:10.1039/b706940e · Cited by 67
He, P., Greenway, G. M., & Haswell, S. J. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0476-8 · Cited by 66
Wu, H., Tian, Y., Liu, B., Lu, H., Wang, X., Zhai, J., Hong, J., Yang, P., Xu, Y., & Wang, H. (2004) · Journal of Proteome Research · doi:10.1021/pr049889z · Cited by 65
Controlled protein adsorption on microfluidic channels with engineered roughness and wettability
Tsougeni, K., Petrou, P. S., Papageorgiou, D. P., Kakabakos, S. E., Tserepi, A. D., & Gogolides, Ε. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.10.022 · Cited by 64
Microfluidic selection and applications of aptamers
Mosing, R. K., & Bowser, M. T. (2007) · Journal of Separation Science · doi:10.1002/jssc.200600483 · Cited by 63
Liu, Y., Yang, D., Yu, T., & Jiang, X. (2009) · Electrophoresis · doi:10.1002/elps.200900128 · Cited by 62
A label‐free protein microfluidic array for parallel immunoassays
Wang, Z.-H., Meng, Y., Ying, P., Cai, Q., & Jin, G. (2006) · Electrophoresis · doi:10.1002/elps.200500956 · Cited by 58
Programmable assembly of a metabolic pathway enzyme in a pre-packaged reusable bioMEMS device
Luo, X., Lewandowski, A. T., Yi, H., Payne, G. F., Reza Ghodssi, A., Bentley, W. E., & Rubloff, G. W. (2008) · Lab on a Chip · doi:10.1039/b713756g · Cited by 53
Surface patterning of bonded microfluidic channels
Priest, C. (2010) · Biomicrofluidics · doi:10.1063/1.3493643 · Cited by 44
Sung, W., Chen, H.-H., Makamba, H., & Chen, S. (2009) · Analytical Chemistry · doi:10.1021/ac901138w · Cited by 39
Hughes, A. J., & Herr, A. E. (2010) · Analytical Chemistry · doi:10.1021/ac100201z · Cited by 36
Self-citationThierry, B., Kurkuri, M. D., Shi, J. Y., Lwin, E. M. P., & Palms, D. (2010) · Biomicrofluidics · doi:10.1063/1.3480573 · Cited by 35
Direct Writing of Metal Nanoparticle Films Inside Sealed Microfluidic Channels
Castellana, E. T., Kataoka, S., Albertorio, F., & Cremer, P. S. (2005) · Analytical Chemistry · doi:10.1021/ac051288j · Cited by 31
Use of protein?acrylamide copolymer hydrogels for measuring protein concentration and activity*1
Brueggemeier, S. B., Kron, S. J., & Palecek, S. P. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2004.02.012 · Cited by 25
Cited by
Wongkaew, N., Simsek, M., Griesche, C., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00172 · Cited by 657
Herland, A., van der Meer, A. D., FitzGerald, E. A., Park, T.-E., Sleeboom, J. J. F., & Ingber, D. E. (2016) · PLOS ONE · doi:10.1371/journal.pone.0150360 · Cited by 476
Biosensor nanoengineering: Design, operation, and implementation for biomolecular analysis
Purohit, B., Vernekar, P. R., Shetti, N. P., & Chandra, P. (2020) · Sensors International · doi:10.1016/j.sintl.2020.100040 · Cited by 421
Antibodies and antibody-derived analytical biosensors
Sharma, S., Byrne, H., & O'Kennedy, R. J. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150002 · Cited by 396
Functionalizing nanoparticles with cancer-targeting antibodies: A comparison of strategies
Marques, A. C., Costa, P. J., Velho, S., & Amaral, M. H. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.01.035 · Cited by 349
Metadata
- Authors
- Kim, D., & Herr, A. E.
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2013-07-01
- Volume
- 7
- Issue
- 4
- Pages
- 41501-41501
- ISSN
- 1932-1058 (ISSN-L)
- OpenAlex
- W2025297340
- Cited by
- 376
- References
- 109
- FWCI
- 16.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.