The microfluidics of the eccrine sweat gland, including biomarker partitioning, transport, and biosensing implications
Open accessThe DOI matches its Crossref record; 86 of the 86 references it cites were found in a registry or an index.
Abstract
Non-invasive and accurate access of biomarkers remains a holy grail of the biomedical community. Human eccrine sweat is a surprisingly biomarker-rich fluid which is gaining increasing attention. This is especially true in applications of continuous bio-monitoring where other biofluids prove more challenging, if not impossible. However, much confusion on the topic exists as the microfluidics of the eccrine sweat gland has never been comprehensively presented and models of biomarker partitioning into sweat are either underdeveloped and/or highly scattered across literature. Reported here are microfluidic models for eccrine sweat generation and flow which are coupled with review of blood-to-sweat biomarker partition pathways, therefore providing insights such as how biomarker concentration changes with sweat flow rate. Additionally, it is shown that both flow rate and biomarker diffusion determine the effective sampling rate of biomarkers at the skin surface (chronological resolution). The discussion covers a broad class of biomarkers including ions (Na+, Cl−, K+, NH4+), small molecules (ethanol, cortisol, urea, and lactate), and even peptides or small proteins (neuropeptides and cytokines). The models are not meant to be exhaustive for all biomarkers, yet collectively serve as a foundational guide for further development of sweat-based diagnostics and for those beginning exploration of new biomarker opportunities in sweat.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The relatively stable behaviour of [K+] is explained by its passive ion partitioning mechanism13.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [13]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The decreases in concentration of lactate and glucose in sweat are expected, owing to the dilution effect caused by an increase in sweat rate, which is visually observed as exercise continues13.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [13]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The accurate measurement of physiologically relevant sweat glucose concentrations with epidermal biosensors faces several major challenges related to uncontrolled operational conditions (e.g., varying temperature and pH), glucose contamination from various sources, irregular sampling rates, and low sampling volumes.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [64]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Detection of biomarkers from eccrine sweat glands pose tremendous advantages over those from urine, blood, tears, and apocrine sweat glands. These, include their abundance on the body (>100 glands/cm2), ease of access, sampling and detection efficiency without foreign contamination during testing, and the inability to degrade analytes19 (Table 3).”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [19]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The color change in the detection reservoir correlated with the concentration of lactate throughout the relevant range expected in sweat (1.5 to 100 mM) (Fig. 3C) (13, 46, 47).”
From A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat (2016) · cites this paper as [13]
Experimental — accuracy not yet measured
14 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrowetting: from basics to applications
Mugele, F., & Baret, J.-C. (2005) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/17/28/r01 · Cited by 2,092
Clinical Methods: The History, Physical, and Laboratory Examinations
Kruse, J. A. (1990) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1990.03450210108045 · Cited by 2,029
Handbook of Experimental Pharmacology.
Meakin, J. W. (1971) · Archives of Internal Medicine · doi:10.1001/archinte.1971.00310230151026 · Cited by 1,959
Salivary cortisol as a biomarker in stress research
Hellhammer, D. H., Wüst, S., & Kudielka, B. M. (2009) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2008.10.026 · Cited by 1,925
Salivary Cortisol in Psychobiological Research: An Overview
Kirschbaum, C., & Hellhammer, D. H. (2008) · Neuropsychobiology · doi:10.1159/000118611 · Cited by 1,532
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Diagnostic Potential of Saliva: Current State and Future Applications
Pfaffe, T., Cooper-White, J., Beyerlein, P., Kostner, K., & Punyadeera, C. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.153767 · Cited by 798
Biology of sweat glands and their disorders. I. Normal sweat gland function
Sato, K., Kang, W. H., Saga, K., & Sato, K. T. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70063-3 · Cited by 717
Research works printed but not linked: 10
- 1977, Reviews of Physiology, Biochemistry and Pharmacology, 51
- C. Tronstad , “ Developments in biomedical sensors based on electrical impedance,” Doctor Philosophiae thesis ( University of Oslo, 2012).
- T. A. Peyser , R. O.Potts, H. L.Berman, J. W.Moyer, and M. A.Kouchnir, “ Devices, methods, and kits for non-invasive glucose measurement,” U.S. patent 7,725,149 (2010).
- 1993, The mechanism of eccrine sweat secretion, Perspect. Exercise Sci. Sports Med., 6, 85
- 2008, Theoretical Microfluidics, 346
- 2011, Medical Physiology: A Cellular and Molecular Approach
- 1999, Fitzpatrick's Dermatology in General Medicine
- 2000, Salivary cortisol, Encycl. Stress, 3, 379
- 2011, Peptides and proteins in pharmaceuticals, Int. J. Curr. Pharm. Res., 3, 1
- See supplementary material at http://dx.doi.org/10.1063/1.4921039E-BIOMGB-9-002503 for the derivation of the solute transport equation and sampling rate limitations for biosensors. · doi:10.1063/1.4921039e-biomgb-9-002503
Cited by
Items 401–500 of 782
Liu, X., Zhao, L., Miao, B., Gu, Z., Wang, J., Peng, H., Li, J., Sun, W., & Li, J. (2019) · Electroanalysis · doi:10.1002/elan.201900405 · Cited by 23
Passively Addressable Ultra-Low Volume Sweat Chloride Sensor
Ganguly, A., & Prasad, S. (2019) · Sensors · doi:10.3390/s19204590 · Cited by 23
Stretchable Sensors for Nanomolar Glucose Detection
Imamura, A. H., Zakashansky, J. A., Cho, K., Lin, L., Carrilho, E., & Khine, M. (2020) · Advanced Materials Technologies · doi:10.1002/admt.201900843 · Cited by 23
Ohashi, T., Gerrett, N., Shinkawa, S., Satō, T., Miyake, R., Kondo, N., & Mitsuzawa, S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03466 · Cited by 23
Lu, L., Sun, Q., Lin, Z., Xu, W., Li, X., Wang, T., Lu, Y., Wu, H., Cheng, L., & Liu, A. (2025) · Biosensors · doi:10.3390/bios15060342 · Cited by 22
Smart polymers for 3D printing applications: current status and future outlook
Singh, N., Sinha, P., Sinha, D. K., & Banerjee, S. (2025) · Polymer Chemistry · doi:10.1039/d5py00741k · Cited by 22
Recent developments in wearable & non-wearable point-of-care biosensors for cortisol detection
Kaur, S., Gupta, N., & Malhotra, B. D. (2023) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2023.2184260 · Cited by 22
Thin, soft, skin-integrated electronics for real-time and wireless detection of uric acid in sweat
Hu, Y., Wang, L., Li, J., Yang, Y., Zhao, G., Liu, Y., Huang, X., Wu, P., Zhang, B., Jiao, Y., et al. (2023) · International Journal of Smart and Nano Materials · doi:10.1080/19475411.2023.2236997 · Cited by 22
A review of new insights into existing major depressive disorder biomarkers
Rimti, F. H., Shahbaz, R., Bhatt, K., & Xiang, A. J. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e18909 · Cited by 22
Dual-Valved Skin-Interfaced Microfluidic Device for Programmed Time-Control Sweat Collection
Yang, J. H., David, U., Noh, Y. S., & Koh, A. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.134441 · Cited by 22
Novel Sweat-Based Wearable Device for Advanced Monitoring of Athletic Physiological Biometrics
Aguilar-Torán, J., Rabost-Garcia, G., Toinga-Villafuerte, S., Álvarez-Carulla, A., Colmena-Rubil, V., Fajardo-Garcia, A., Cardona-Bonet, A., Casals‐Terré, J., Muñoz-Pascual, X., Miribel‐Català, P. L., et al. (2023) · Sensors · doi:10.3390/s23239473 · Cited by 23
Zhong, B., Xu, H., Qin, X., Liu, L., Wang, H., & Wang, L. (2024) · Bio-Design and Manufacturing · doi:10.1007/s42242-024-00294-2 · Cited by 22
Wearable Devices - the Big Wave of Innovation
Nasiri, N. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.77458 · Cited by 22
Peng, M., Ning, Y., Zhang, J. W., He, Y., Xu, Z., Li, D., Yang, Y., & Ren, T.-L. (2026) · Biosensors · doi:10.3390/bios16010046 · Cited by 21
MWCNTs/PANI silk fibroin film sensor based on microneedle array for sweat pH detection
Kuang, D., Tan, Y., Song, L., Tang, J., & Wang, C. (2025) · Microchimica Acta · doi:10.1007/s00604-025-07043-x · Cited by 21
Hladek, M. D., Gill, J., Lai, C., Lorig, K. R., & Szanton, S. L. (2019) · Biological Research For Nursing · doi:10.1177/1099800419870607 · Cited by 21
Steijlen, A. S. M., Bastemeijer, J., Groen, P., Jansen, K. M. B., French, P. J., & Bossche, A. (2020) · Analytical Methods · doi:10.1039/d0ay02014a · Cited by 21
WS2/CuO-based non-enzymatic sensor for the detection of glucose in sweat
Li, D., Yang, M., Li, W., Wang, A., Wang, X., Liang, H., Dong, L., Xu, H., & Wang, G. (2025) · Analytica Chimica Acta · doi:10.1016/j.aca.2025.344696 · Cited by 20
Review of point-of-care platforms for diabetes: (1) sensing
Liu, Y., Luo, X., Yu, Q., Ye, L., Yang, L., & Cui, Y. (2022) · Sensors and Actuators Reports · doi:10.1016/j.snr.2022.100113 · Cited by 20
Hossain, N. I., Sharma, A., & Sonkusale, S. (2023) · IEEE Sensors Letters · doi:10.1109/lsens.2023.3300827 · Cited by 20
Wearable Sweat Management Technologies
Wei, L., Li, Z., Dai, Z., Ding, L., Wei, H., Li, J., Zhu, H., & Zhu, Y. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202301812 · Cited by 20
Ma, J., Li, H., Anwer, S., Umer, W., Antwi‐Afari, M. F., & Xiao, E. B. (2024) · International Journal of Occupational Safety and Ergonomics · doi:10.1080/10803548.2024.2330242 · Cited by 21
Qian, Y. H., Wang, H., Qu, Z., Li, Q., Wang, D., Yang, X., Qin, H., Wei, H., Zhang, F., & Qing, G. (2024) · Materials Horizons · doi:10.1039/d4mh01148a · Cited by 20
Oh, D. Y., Na, H., Song, S. W., Kim, J., In, H., Lee, A. C., Jeong, Y., Lee, D., Jang, J., & Kwon, S. (2018) · Biomicrofluidics · doi:10.1063/1.5032170 · Cited by 20
Non-invasive Drug Monitoring of β-Lactam Antibiotics Using Sweat Analysis—A Pilot Study
Brasier, N., Widmer, A. F., Osthoff, M. F., Mutke, M. R., Ieso, F. D., Brasier-Lutz, P., Wolfe, L. M., Aithal, V., Broeckling, C. D., Prenni, J. E., et al. (2020) · Frontiers in Medicine · doi:10.3389/fmed.2020.00476 · Cited by 20
Porous carbon-based robust, durable, and flexible electrochemical device for K + detection in sweat
Jiang, T., Yin, B., Liu, X., Yang, L., Pang, H., Song, J., & Wu, S. (2022) · The Analyst · doi:10.1039/d1an02322e · Cited by 20
Ding, H., Yang, H., & Tsujimura, S. (2024) · Advanced Science · doi:10.1002/advs.202401947 · Cited by 19
Wu, Y., Li, X., Madsen, K. E., Zhang, H., Cho, S., Song, R., Nuxoll, R. F., Xiong, Y., Liu, J., Feng, J., et al. (2024) · Lab on a Chip · doi:10.1039/d4lc00588k · Cited by 19
CdSSe nanowire-chip based wearable sweat sensor
Zhang, M., Guo, S., Weller, D., Hao, Y., Wang, X., Ding, C., Chai, K., Zou, B., & Liu, R. (2019) · Journal of Nanobiotechnology · doi:10.1186/s12951-019-0480-4 · Cited by 19
Upasham, S., Osborne, O., & Prasad, S. (2021) · RSC Advances · doi:10.1039/d0ra10561a · Cited by 19
Simultaneous multi-location wireless monitoring of sweat lactate trends
Gillan, L., Teerinen, T., Suhonen, M., Kivimäki, L., & Alastalo, A. T. (2021) · Flexible and Printed Electronics · doi:10.1088/2058-8585/ac13c4 · Cited by 19
Dermal-fluid-enabled detection platforms for non-invasive ambulatory monitoring
Veronica, A., Li, Y., Li, Y., Hsing, I., & Nyein, H. Y. Y. (2023) · Sensors & Diagnostics · doi:10.1039/d3sd00165b · Cited by 19
Microfluidic technologies for local drug delivery
Hassan, S., & Zhang, Y. S. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812659-2.00010-7 · Cited by 18
Flexible Thin‐Film Electrodes on Porous Polyester Membranes for Wearable Sensors
Gangopadhyay, A., Nablo, B. J., Rao, M. V., & Reyes, D. R. (2016) · Advanced Engineering Materials · doi:10.1002/adem.201600592 · Cited by 18
The Sub-THz Emission of the Human Body Under Physiological Stress
Baksheeva, K. A., Ozhegov, R. V., Gol'tsman, G. N., Kinev, N. V., Koshelets, V. P., Goldstein, A. K., Betzalel, N., Puzenko, A. A., Ishai, P. B., & Feldman, Y. D. (2021) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2021.3066099 · Cited by 18
Biomolecular profiling for noninvasive health monitoring
Kim, M., Lasalde‐Ramírez, J. A., Heng, W., & Gao, W. (2026) · Nature Biotechnology · doi:10.1038/s41587-026-03050-2 · Cited by 17
Flexible Electrochemical Sensors and Their Applications in Noninvasive Medical Detection★
Liang, H., Ma, H., Duan, X., Yu, J., Wang, H., Li, S., Zhu, M., Chen, A., Zheng, H., & Zhang, Y. (2023) · 化学学报 · doi:10.6023/a23060289 · Cited by 17
Capillary-osmotic wearable patch based on lateral flow assay for sweat potassium analysis
Mukherjee, S., Salazar, S. P., Saha, T., Dickey, M. D., & Velev, O. D. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136383 · Cited by 17
Discretised microfluidics for noninvasive health monitoring using sweat sensing
Moonen, E. J. M., Verberne, W., Pelssers, E., Heikenfeld, J. C., & den Toonder, J. M. J. (2024) · Lab on a Chip · doi:10.1039/d4lc00763h · Cited by 18
Self-citationMiniaturized power-integrated and self-powered sensor systems for advanced biomedical applications
Yun, J., Keerthana, S., & Kwon, S. (2024) · Sensors and Actuators Reports · doi:10.1016/j.snr.2024.100260 · Cited by 17
Animal-Free Chemical Safety Assessment
Loizou, G. D. (2016) · Frontiers in Pharmacology · doi:10.3389/fphar.2016.00218 · Cited by 17
Wearable pH sensing beyond the Nernst limit
Yang, Y., & Gao, W. F. (2018) · Nature Electronics · doi:10.1038/s41928-018-0166-1 · Cited by 17
Electrochemical (bio-)sensors operating in human physiological fluids
Psotta, C. (2023) · doi:10.24834/isbn.9789178773992 · Cited by 17
Yang, D. S., Zhou, M., Li, S., Cho, S., Wu, Y., Sekine, Y., Kanatzidis, E. E., Lv, Z., Yamagishi, K., Kim, J., et al. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202509169 · Cited by 16
Fu, X., Qiu, Y., Zhang, H., Tian, Y., Liu, A., & Wu, H. (2024) · Biomicrofluidics · doi:10.1063/5.0208075 · Cited by 16
Vittrant, B., Ayoub, H., & Brunswick, P. (2024) · Frontiers in Neuroanatomy · doi:10.3389/fnana.2024.1454095 · Cited by 16
Alsultan, M. A., López-Soriano, S., & Melià‐Seguí, J. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3546431 · Cited by 16
Caduff, A., Feldman, Y. D., Ishai, P. B., & Launer, S. (2020) · Ear and Hearing · doi:10.1097/aud.0000000000000960 · Cited by 16
Long-term cyclic use of a sample collector for toilet-based urine analysis
Temirel, M., Yenilmez, B., & Taşoğlu, S. (2021) · Scientific Reports · doi:10.1038/s41598-021-81842-z · Cited by 16
Copper Oxide Solution Sensor Formed on a Thin Film Having Nanowires for Detecting Ethanol in Water
Kimura, Y., & Tohmyoh, H. (2022) · Langmuir · doi:10.1021/acs.langmuir.2c01160 · Cited by 15
A versatile artificial skin platform for sweat sensor development
Moonen, E. J. M., Islam, T. U., van Kemenade, S., Pelssers, E., Heikenfeld, J. C., & den Toonder, J. M. J. (2023) · Lab on a Chip · doi:10.1039/d3lc00109a · Cited by 16
Self-citationXu, W., Hong, L., Zheng, J., Li, M., Hua, Y., & Zhao, X. (2023) · IEEE Internet of Things Journal · doi:10.1109/jiot.2023.3317141 · Cited by 15
Wearable Devices for Biofluid Monitoring in a Body: from Lab to Commercialization
Yang, Y. J., Lee, S. G., & Kim, T. (2024) · Korean Journal of Chemical Engineering · doi:10.1007/s11814-024-00295-y · Cited by 15
Sweat Pore‐Inspired Functional Nanofiber Fabrics for Sweat Management and Simultaneous Detection
Wang, R., Guan, C., Jin, X., Chai, J., Zhou, F., Wang, N., & Song, B. (2024) · Small · doi:10.1002/smll.202408465 · Cited by 15
Recent Advances in Wearable Sweat Sensor Development
Zhang, T., Kabandana, G. K. M., Terrell, J. A., Chen, H., & Chen, C. (2025) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.70006 · Cited by 15
Coşkun, A., Savaş, İ. N., Can, O., & Lippi, G. (2025) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2025.2453152 · Cited by 15
High-Suitcordance Intelligent Fibers for Panvascular Disease Monitoring-Intervention
You, L., Luo, Y., Cheng, Q., Shen, L., & Ge, J. (2025) · Advanced Fiber Materials · doi:10.1007/s42765-025-00542-9 · Cited by 15
Sebastia‐Saez, D., Burbidge, A., Engmann, J., & Ramaioli, M. (2020) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2020.106976 · Cited by 15
Advances in Wearable Chemosensors
Korallı, P., & Mouzakis, D. E. (2021) · Chemosensors · doi:10.3390/chemosensors9050099 · Cited by 15
A Simple Non-Contact Optical Method to Quantify In-Vivo Sweat Gland Activity and Pulsation
Drexelius, A., Fehr, D., Vescoli, V., Heikenfeld, J. C., & Bonmarin, M. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3151938 · Cited by 15
Self-citationLiu, Y., Li, J., Xu, D., Su, Z., Ge, C., Chen, Z., Xu, W., & Liu, K. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202300543 · Cited by 15
Space-filling open microfluidic channels designed to collect water droplets
Kai, H., Toyosato, R., & Nishizawa, M. (2018) · RSC Advances · doi:10.1039/c8ra02655f · Cited by 15
Chiaula, V., Mazurek, P., Eiler, J., Nielsen, A. C., & Skov, A. L. (2020) · International Journal of Adhesion and Adhesives · doi:10.1016/j.ijadhadh.2020.102667 · Cited by 15
Thermal signatures of liquid droplets on a skin induced by emotional sweating
Koroteeva, E. Y., & Bashkatov, A. A. (2021) · Quantitative InfraRed Thermography Journal · doi:10.1080/17686733.2020.1846113 · Cited by 15
Electrochemical Devices to Monitor Ionic Analytes for Healthcare and Industrial Applications
Fan, S.-Y., Khuntia, S., Ahn, C. H., Zhang, B., & Tai, L. (2022) · Chemosensors · doi:10.3390/chemosensors10010022 · Cited by 15
Park, S. H., & Pak, J. J. (2024) · Sensors · doi:10.3390/s24216945 · Cited by 14
2D-MXenes: Progress in synthesis, intercalation, and applications in microfluidic sensors
Ahmad, M. M., Ma, Y., Badshah, M., Ali, S., Idrees, M., Ismail, M. A., Khan, S., Javed, M. S., Tamang, T. L., & Pu, Q. (2024) · Surfaces and Interfaces · doi:10.1016/j.surfin.2024.105678 · Cited by 14
Yin, X., Peri, E., Pelssers, E., den Toonder, J. M. J., Klous, L., Daanen, H. A. M., & Mischi, M. (2025) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2025.108743 · Cited by 14
Advancements and Obstacles in Sweat-Based Biosensors for Health Monitoring
Lihong, Z., & Li, Q. (2025) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2025.2568615 · Cited by 14
Ita, K. B. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-822550-9.00002-8 · Cited by 14
Noninvasive Epidermal Metabolite Profiling
Stoffers, K. M., Cronkright, A. A., Huggins, G. S., & Baleja, J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c02274 · Cited by 14
Methods for assessment of vitamin C
Card, D. J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813050-6.00013-9 · Cited by 14
Chen, H., Xu, S., Liu, H., Liu, C., Liu, H., Chen, J., Huang, H., Gong, H., Wu, J., Tang, H., et al. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202309798 · Cited by 14
Wearable and Flexible Sensors Based on 2D and Nanomaterials
Samal, R., & Rout, C. S. (2019) · Elsevier eBooks · doi:10.1016/b978-0-08-102577-2.00012-9 · Cited by 14
Sensing of KCl, NaCl, and Pyocyanin with a MOF-Decorated Electrospun Nitrocellulose Matrix
Lüder, L., Nirmalraj, P. N., Neels, A., Rossi, R. M., & Calame, M. (2023) · ACS Applied Nano Materials · doi:10.1021/acsanm.2c05252 · Cited by 14
A geometrical model for diffusion of hydrophilic compounds in human stratum corneum
Yu, F., & Kasting, G. B. (2018) · Mathematical Biosciences · doi:10.1016/j.mbs.2018.03.010 · Cited by 14
Self-citationSimmers, P., Yuan, Y., Sonner, Z., & Heikenfeld, J. C. (2018) · Biomicrofluidics · doi:10.1063/1.5023396 · Cited by 14
Self-citationLaser-Induced Graphene Electrodes for Flexible pH Sensors
Massaglia, G., Spisni, G., Serra, T., & Quaglio, M. (2024) · Nanomaterials · doi:10.3390/nano14242008 · Cited by 13
Flexible microcolumn array-based silk fibroin for sweat glucose monitoring
Kuang, D., Tan, Y., Han, W., Yin, Y., & Wang, C. (2025) · Analytica Chimica Acta · doi:10.1016/j.aca.2025.343857 · Cited by 13
Sharkey, C. T., Aroche, A. F., Agusta, I. G., Nissan, H. E., Saha, T., Mukherjee, S., Twiddy, J. S., Dickey, M. D., Velev, O. D., & Daniele, M. A.-A. (2025) · Lab on a Chip · doi:10.1039/d5lc00590f · Cited by 13
Ruwe, T., White, E., Zebertavage, A. S., Runnoe, D., Fay, D., Daumeyer, H., Tracy, T. S., Uchtman, K. F., Begtrup, G., Yuan, Y., et al. (2023) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000001110 · Cited by 13
Self-citationFlexible Ion Sensors for Bodily Fluids
Dam, V. A. T., Zevenbergen, M. A. G., & van Schaijk, R. T. F. (2016) · Procedia Engineering · doi:10.1016/j.proeng.2016.11.155 · Cited by 13
Recent Impact of Microfluidics on Skin Models for Perspiration Simulation
Rabost-Garcia, G., Farré‐Lladós, J., & Casals‐Terré, J. (2021) · Membranes · doi:10.3390/membranes11020150 · Cited by 13
Liu, X., Huang, S., Ma, L., Ye, H., Lin, J., Cai, X., Shang, Q., Zheng, C., Xu, R., & Zhang, D. (2022) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2022.115006 · Cited by 13
Wearable Chemosensors in Physiological Monitoring
Tang, Z.-Y., Cui, T., Liu, H., Jian, J., Li, D., Yang, Y., & Ren, T. (2023) · Chemosensors · doi:10.3390/chemosensors11080459 · Cited by 12
Fundamental Study of a Wristwatch Sweat Lactic Acid Monitor
Konno, S., & Kudo, H. (2024) · Biosensors · doi:10.3390/bios14040187 · Cited by 12
Liu, Y., Luo, T., Ding, C., Xuan, L., Li, J., & Yang, R. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202400619 · Cited by 12
Design strategies for skin-interfaced sensors
Guo, S., & Huang, H. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115671 · Cited by 12
Percutaneous Wearable Biosensors: A Brief History and Systems Perspective
Peterson, K., Shukla, R. P., & Daniele, M. A.-A. (2024) · Advanced Sensor Research · doi:10.1002/adsr.202400068 · Cited by 12
Hydrogels for emerging wearable sweat monitoring devices
Nie, Z., Qu, X. D., He, M. S., Zhen, S., Peng, K., & Chen, Y. (2025) · Intelligent Sports and Health · doi:10.1016/j.ish.2025.09.001 · Cited by 12
Hydrophilic skin-interfaced microfluidic devices for comprehensive sweat collection and analysis
Lu, F., Yang, J. H., & Koh, A. (2025) · Lab on a Chip · doi:10.1039/d5lc00703h · Cited by 12
Paper-based microfluidics in sweat detection: from design to application
Ye, Z., Yuan, Y., Zhan, S., Liu, W., Lü, F., & Li, T. (2023) · The Analyst · doi:10.1039/d2an01818g · Cited by 13
Printed Wearable Sweat Rate Sensor for Continuous In Situ Perspiration Measurement
Islam, M. S., Cha, S., Hassan, M. F., Cai, W., Saniat, T. S., Leach, C. R., & Khan, Y. (2024) · Advanced Intelligent Systems · doi:10.1002/aisy.202400927 · Cited by 12
Fluid-permeable enzymatic lactate sensors for micro-volume specimen
Kai, H., Kato, Y., Toyosato, R., & Nishizawa, M. (2018) · The Analyst · doi:10.1039/c8an00979a · Cited by 12
Choi, D., Kitchen, G. B., Kim, J. S., Li, Y., Kim, K., Jeong, I. C., Nguyen, J., Stewart, K. J., Zeger, S. L., & Searson, P. C. (2019) · Scientific Reports · doi:10.1038/s41598-019-54202-1 · Cited by 12
García-Rey, S., Gil-Hernández, E., Gunatilake, U. B., Basabe‐Desmonts, L., & Benito‐Lopez, F. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.133514 · Cited by 12
Choi, S., Kim, C. H., Kim, J. H., Kim, K. H., Park, S. Y., Ko, Y. J., Kang, H., Kim, Y. B., Woo, Y. M., Seok, J. Y., et al. (2025) · Energy & environment materials · doi:10.1002/eem2.70005 · Cited by 11
Biomedical sensing applications of soft, wearable microfluidic systems
Ibrahim, M. E., Naman, A., Lee, M.-S., Park, S., Lee, D., Kwak, Y., & Kim, M. (2025) · Soft Science · doi:10.20517/ss.2025.45 · Cited by 11
Burton, A., Stuart, T., Ausra, J., & Gutruf, P. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817044-1.00010-7 · Cited by 11
Xiao, M., Deng, L., He, J., Xu, Y., Liu, S., Lin, H., Qi, N., & Zhang, D. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5c11437 · Cited by 10
Metadata
- Authors
- Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., & Naik, R.
- Affiliations
- University of Cincinnati (US)
- Procter & Gamble (United States) (US)
- United States Air Force Research Laboratory (US)
- Air Force Research Laboratory 5 711 Human Performance Wing, Human Effectiveness Directorate, , Wright-Patterson Air Force Base, Dayton, Ohio 45233, USA
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2015-05-01
- Volume
- 9
- Issue
- 3
- Pages
- 031301-031301
- ISSN
- 1932-1058 (ISSN-L)
- PMC
- PMC4433483
- OpenAlex
- W1548680965
- Cited by
- 724
- References
- 86
- Citations by year
- 2026: 57 · 2025: 80 · 2024: 96 · 2023: 84 · 2022: 76 · 2021: 79 · 2020: 84 · 2019: 60 · 2018: 55 · 2017: 30 · 2016: 20 · 2015: 2
- FWCI
- 17.72
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/3.0/ (vor, 14 d)
- creativecommons.org/licenses/by/3.0/ (tdm, 14 d)
- Locations
- Biomicrofluidics (publishedVersion, cc-by)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Center for Advanced Design and Manufacturing of Integrated Microfluidics (IIP-1362165)
- Air Force Office of Scientific Research (Summer Faculty Fellowship Program)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Keywords
- eccrine sweat glands, sweat biomarkers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.