The microfluidics of the eccrine sweat gland, including biomarker partitioning, transport, and biosensing implications
Open accessThe DOI matches its Crossref record; 86 of the 86 references it cites were found in a registry or an index.
Abstract
Non-invasive and accurate access of biomarkers remains a holy grail of the biomedical community. Human eccrine sweat is a surprisingly biomarker-rich fluid which is gaining increasing attention. This is especially true in applications of continuous bio-monitoring where other biofluids prove more challenging, if not impossible. However, much confusion on the topic exists as the microfluidics of the eccrine sweat gland has never been comprehensively presented and models of biomarker partitioning into sweat are either underdeveloped and/or highly scattered across literature. Reported here are microfluidic models for eccrine sweat generation and flow which are coupled with review of blood-to-sweat biomarker partition pathways, therefore providing insights such as how biomarker concentration changes with sweat flow rate. Additionally, it is shown that both flow rate and biomarker diffusion determine the effective sampling rate of biomarkers at the skin surface (chronological resolution). The discussion covers a broad class of biomarkers including ions (Na+, Cl−, K+, NH4+), small molecules (ethanol, cortisol, urea, and lactate), and even peptides or small proteins (neuropeptides and cytokines). The models are not meant to be exhaustive for all biomarkers, yet collectively serve as a foundational guide for further development of sweat-based diagnostics and for those beginning exploration of new biomarker opportunities in sweat.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The relatively stable behaviour of [K+] is explained by its passive ion partitioning mechanism13.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [13]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The decreases in concentration of lactate and glucose in sweat are expected, owing to the dilution effect caused by an increase in sweat rate, which is visually observed as exercise continues13.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [13]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The accurate measurement of physiologically relevant sweat glucose concentrations with epidermal biosensors faces several major challenges related to uncontrolled operational conditions (e.g., varying temperature and pH), glucose contamination from various sources, irregular sampling rates, and low sampling volumes.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [64]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Detection of biomarkers from eccrine sweat glands pose tremendous advantages over those from urine, blood, tears, and apocrine sweat glands. These, include their abundance on the body (>100 glands/cm2), ease of access, sampling and detection efficiency without foreign contamination during testing, and the inability to degrade analytes19 (Table 3).”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [19]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The color change in the detection reservoir correlated with the concentration of lactate throughout the relevant range expected in sweat (1.5 to 100 mM) (Fig. 3C) (13, 46, 47).”
From A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat (2016) · cites this paper as [13]
Experimental — accuracy not yet measured
14 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrowetting: from basics to applications
Mugele, F., & Baret, J.-C. (2005) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/17/28/r01 · Cited by 2,092
Clinical Methods: The History, Physical, and Laboratory Examinations
Kruse, J. A. (1990) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1990.03450210108045 · Cited by 2,029
Handbook of Experimental Pharmacology.
Meakin, J. W. (1971) · Archives of Internal Medicine · doi:10.1001/archinte.1971.00310230151026 · Cited by 1,959
Salivary cortisol as a biomarker in stress research
Hellhammer, D. H., Wüst, S., & Kudielka, B. M. (2009) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2008.10.026 · Cited by 1,925
Salivary Cortisol in Psychobiological Research: An Overview
Kirschbaum, C., & Hellhammer, D. H. (2008) · Neuropsychobiology · doi:10.1159/000118611 · Cited by 1,532
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Diagnostic Potential of Saliva: Current State and Future Applications
Pfaffe, T., Cooper-White, J., Beyerlein, P., Kostner, K., & Punyadeera, C. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.153767 · Cited by 798
Biology of sweat glands and their disorders. I. Normal sweat gland function
Sato, K., Kang, W. H., Saga, K., & Sato, K. T. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70063-3 · Cited by 717
Research works printed but not linked: 10
- 1977, Reviews of Physiology, Biochemistry and Pharmacology, 51
- C. Tronstad , “ Developments in biomedical sensors based on electrical impedance,” Doctor Philosophiae thesis ( University of Oslo, 2012).
- T. A. Peyser , R. O.Potts, H. L.Berman, J. W.Moyer, and M. A.Kouchnir, “ Devices, methods, and kits for non-invasive glucose measurement,” U.S. patent 7,725,149 (2010).
- 1993, The mechanism of eccrine sweat secretion, Perspect. Exercise Sci. Sports Med., 6, 85
- 2008, Theoretical Microfluidics, 346
- 2011, Medical Physiology: A Cellular and Molecular Approach
- 1999, Fitzpatrick's Dermatology in General Medicine
- 2000, Salivary cortisol, Encycl. Stress, 3, 379
- 2011, Peptides and proteins in pharmaceuticals, Int. J. Curr. Pharm. Res., 3, 1
- See supplementary material at http://dx.doi.org/10.1063/1.4921039E-BIOMGB-9-002503 for the derivation of the solute transport equation and sampling rate limitations for biosensors. · doi:10.1063/1.4921039e-biomgb-9-002503
Cited by
Items 701–782 of 782
Legner, C. M. (2020) · Iowa State University Digital Repository (Iowa State University) · doi:10.31274/etd-20210114-80
Melios, N. (2021) · DSpace - NTUA (National Technical University of Athens) · doi:10.26240/heal.ntua.21530
Nagamine, K., Sekine, T., & Tokito, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00077-7
Dielectric spectroscopy for hydration monitoring, from application to portable sensors
van der Lingen, E. (2020) · Research Repository (Delft University of Technology)
Goto, Y., Suzuki, Y., Morisawa, K., Hosoyama, A., Taira, Y., & Kudo, H. (2021) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/1192/1/012006
Cáparra, parada y fonda en la Vía de la Plata
Uceta, A. D. (2003) · La Aventura de la historia
Wristwatch Biosensor For Sweat Lactic Acid Monitoring
YAMADA, M., Konno, S., Kawaura, D., & Kudo, H. (2022) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems51670.2022.9699678
Fabrication and Applications of Antibacterial Surfaces and Nano Biosensing Platforms
Jaggessar, A., Hasan, J., & Yarlagadda, P. K. D. V. (2022) · Lecture notes in networks and systems · doi:10.1007/978-3-030-90532-3_58
Chiriacò, M. S., Ferrara, F., & Primiceri, E. (2022) · MDPI eBooks · doi:10.3390/books978-3-0365-3415-2
Preparation of the artificial “skin” uniform sweating simulation device
Zheng, H., Liu, M., Yang, X., Cao, Y. F., Nie, W., Wang, S., & Zhang, T. (2022) · Scientia Sinica Technologica · doi:10.1360/sst-2022-0114
Low-power Wearable Healthcare Sensors
Sherratt, R. S., & Dey, N. (2020) · MDPI eBooks · doi:10.3390/books978-3-03936-480-0
Aprimoramento em biossensores para diagnósticos mais acessíveis
Imamura, A. H. (2022) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.75.2022.tde-11052022-100211
Investigating aluminum salt containing hydrogels in water versus sweat mimics
Ade‐Browne, C., Greenwood, A. I., Neal, T. A., Jones, S. D., Swaile, D. F., & Kumari, H. (2022) · Journal of Coordination Chemistry · doi:10.1080/00958972.2022.2114350
Self-citationRecent Progress on Non-invasive Wearable Epidermal Biosensors
Li, B. (2023) · Theoretical and Natural Science · doi:10.54254/2753-8818/4/20220536
Collisional cooling in CID tandem MS ion trap experiments
Memboeuf, A., Fouque, D. J. D., Pallecchi, M., Maroto, A., & Bartolucci, G. (2023) · Florence Research (University of Florence)
Nuts and Bolts of Modern Biosensing Technology: Smart Health Diagnostic Devices
Jeerapan, I., Valdés‐Ramírez, G., & Brunetti, B. (2023) · Wiley eBooks · doi:10.1002/9783527837946.ch2
Singaram, S., Ramakrishnan, K., Kumar, L., Kumar, F. A., & Thomas, N. M. (2023) · Algorithms for intelligent systems · doi:10.1007/978-981-99-3485-0_36
Wet Interface Technologies for Wearable Sweat Sensors
Nagamine, K., & Tokito, S. (2024) · Springer eBooks · doi:10.1007/978-981-99-8122-9_10
Advances In Therapeutic Use of Microfluidics (Body on A Chip): A Review
(2023) · International Journal of Nanotechnology and Nanomedicine · doi:10.33140/ijnn.08.01.07
Electrochemical analysis of biological fluids
Brown, M. S., Kelly, M., & Koh, A. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-99147-6.00003-x
Wenfeng, W., Jin, Y., Yiduo, H., Zihong, Z., Mao, L., Mao, H., Li, R., & Xiong, J. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4714062
Effect of Aging on Passive Drug Diffusion Through Human Skin
Ranjan, A. K., Duryodhan, V. S., & Patil, N. D. (2024) · Lecture notes in mechanical engineering · doi:10.1007/978-981-99-7177-0_68
Integrated assembly of flexible microneedle array patch for real-time multi-ion monitoring
Ma, Y., Chen, W., Dai, Z., Zhao, Y., Xu, R., Cao, Q., & Liang, B. (2025) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2982/1/012030
Alsultan, M. A., López-Soriano, S., & Melià‐Seguí, J. (2025) · European Conference on Antennas and Propagation · doi:10.23919/eucap63536.2025.11000019
Self-Powered Wearable Health Monitoring Platform
Eslami, R. (2025) · doi:10.32920/30320887
Sweat Biomarkers: Emerging Technologies for Collection and Comprehensive Metabolite ProfilingPreprint
Hossain, P. S., & Marasco, E. (2025) · doi:10.36227/techrxiv.176072479.91739215/v1
Zhang, Z., Addokhi, A., Hughes, K. A., Zang, H., Piqueras, M. D. C., Kuzmanović, U., Charles, R., Leung, L., Klapperich, C. M., Allen, K. N., et al. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.10.31.685570
Sweat Na+/K+ ratio as a practical biological index for estimating sweating rate and salt loss rate
Gommori, N., Nagano, C., Tanaka, T., Tanaka, Y., Mori, K., Inoue, J., Kawanami, S., & Horie, S. (2025) · Journal of Occupational Health · doi:10.1093/joccuh/uiaf066
Han, J. (2023) · University Libraries (University of Maryland) · doi:10.13016/dspace/pgrf-hinl
Gotsmy, M., Brunmair, J., Büschl, C., Gerner, C., & Zanghellini, J. (2022) · Figshare · doi:10.6084/m9.figshare.21151115
Development methodologies of wearable biosensors for personalized health monitoring
Cheng, X. (2023) · eScholarship (California Digital Library)
Serra Sagues, A. (2021) · UPCommons institutional repository (Universitat Politècnica de Catalunya)
Point of use sensing of human performance biomarkers in body fluids
Ray, P. (2018) · OhioLink ETD Center (Ohio Library and Information Network)
New Frontiers in Chemical and Biochemical Methods
Biddle, G. (2023) · ThinkTech (Texas Tech University)
An Integrated System for Sweat Stimulation, Sampling and Sensing
Hauke, A. (2018) · OhioLink ETD Center (Ohio Library and Information Network)
Flexible Electrode Array System for Sweat Analysis in Vitro Information
Shao, Y. (2022) · UTUPub (University of Turku)
Simmers, P. (2018) · OhioLink ETD Center (Ohio Library and Information Network)
The Future of Biological Imaging: Nano-sensors
Choudhary, F., Abdin, M. Z., & Farooqi, H. (2025) · Smart nanomaterials technology · doi:10.1007/978-981-96-6091-9_15
Facile and Flexible Glucose Sensors Based on Copper Thin Films
ALAM, M. M. (2023) · MacSphere (McMaster University) · doi:10.71548/18293
Enveloped ion-selective membranes for robust multi-ion sensing
Zheng, X., Zhou, Y., Tian, Q., Zhou, J., Deng, Z., Shu, X., Wan, Y., Zhao, D., & Huang, W. (2026) · Journal of Materials Chemistry A · doi:10.1039/d5ta09552b
Functionalized nanothin films for noninvasive biosensing
Jose, J., Muhammed Ali, V. P., Uthara, K., Mk, S., Sandeep, B. S., Anagha, C., Vijay, A., Radhakrishnan, E. K., & Pereira, M. L. G. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-18929-6.00018-9
Multifunctional Sweat Sensors Using Semiconductor Fibers Based on Two‐Dimensional Nanomaterials
Park, J. H., Park, J. W., Choi, M. S., Pang, S. U., Choe, J. S., Yu, T. S., Jang, K.-I., Kim, J., Chung, H. U., Kim, J. H., et al. (2026) · Small Structures · doi:10.1002/sstr.202500905
Paper-Based Analytical Devices in Agriculture and Veterinary
Korotcenkov, G. S. (2026) · Springer eBooks · doi:10.1007/978-3-032-02713-9_26
Laser-Induced Breakdown Spectroscopy as a Tool for the Detection of Trace Elements in Sweat
Sreeja, K., V, P, S. T., & Anoop, K. K. (2026) · Journal of Condensed Matter · doi:10.61343/jcm.v4i01.218
Yao, Y., & Xiang, S. (2026) · tm - Technisches Messen · doi:10.1515/teme-2026-0002
Fisayo, O. O., Maku, A. M., Baba, F., Oyewole, O. A., Adetunji, C. O., & Musa, I. O. (2026) · Wiley eBooks · doi:10.1002/9781394272037.ch13
Aerosol jet and 3D printed impedance-based wearable sensors for local sweating rate monitoring
Dong, K., Wen, H., Huang, F., Gao, Z., Cao, Y., Xu, X., Ye, Q., & Liu, Q. (2026) · Microchemical Journal · doi:10.1016/j.microc.2026.118496
Emerging wearable sweat sensors for monitoring sports health
Wen, H., Huang, F., Gao, Z., Cao, Y., Liu, F., Li, A., Cai, W., Pan, T., & Liu, Q. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.118977
Wearable Sensors for Physiological Monitoring: A Comprehensive Review
Gao, Z. (2026) · Theoretical and Natural Science · doi:10.54254/2753-8818/2026.au34966
Saranya, R., Jagadheeswari, B., V, Lavanya, G., Kumar, N. S., Rasheedha, A., & Chamundeswari, K. (2026) · International Conference on Intelligent Technologies (CONIT) · doi:10.1109/conit69683.2026.11621564
Wearable Iontophoretic Biosensing: From Active Sampling Principles to Analytical Validation
Ahmed, F., Song, J., Kim, S., Masud, & Kim, J. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.6c01565
Diao, H., Liu, Y., Tian, X., Gan, N., Jia, Z., & Yu, Z. (2026) · Small · doi:10.1002/smll.75155
Applications of Wearable Sweat Biosensors in Sports Activities with Real-World Cases
Yan, J., Shi, J., Zhang, Z., Yang, M., Zhang, M., & Wang, M. (2026) · Bioengineering · doi:10.3390/bioengineering13080906
Extended Gate Organic Electrochemical Transistor for Sweat Lactate Detection in Hemorrhagic Shock
Nuro, J., Opoku, J. N. K., Pali, M. L., Inam, A. K. M. S., & Tabassum, S. (2026) · IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) · doi:10.1109/fleps69128.2026.11645068
Maximo, R. T., da Silva, M. G. N. M., Martins, D. B. G., Cavalcante, P. S., Tedesco, P., Belian, R. B., & Yara, R. (2026) · Scientific Electronic Archives · doi:10.36560/19520262251
Advancing non-invasive diagnosis through biomarker detection in biofluids
Tang, H., Sun, G., Lu, C., Pouri, H., Panta, R., Chen, T. L., & Zhang, J. (2026) · Nanotechnology · doi:10.1088/1361-6528/ae9d2c
Painless Biosensing for Non‐Invasive Health Monitoring: Advances, Platforms and Future Directions
Alam, A., Gull, F., Hameed, M., Iqbal, I., Naz, S., Noor, H., Aslam, A., Younis, S., Vit, V., Mehmood, M. A., et al. (2026) · Electrochemical Science Advances · doi:10.1002/elsa.70041
Park, R., Heo, B. Y., Choi, S. J., Lee, S., Kim, J., Kim, M. J., Kim, J., Jang, J., Kwon, O. S., Yoo, H. J., et al. (2026) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/aea53e
Multiplex ovarian hormone monitoring in sweat using a dual-aptamer wearable sensor
Lee, Y. S., Ye, C., Yeom, J., Chen, Y., Li, J., Min, J., Wang, M., & Gao, W. F. (2026) · Device · doi:10.1016/j.device.2026.101299
Chen, Y., Liu, X., Zhang, K., Wang, P., Xu, K., Lin, L., Gai, J., Wei, X., & You, H. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.140938
Qi, Q., Duan, J., Lei, Y., Zhou, S., Liu, Q. S., Wang, Q., Gao, N., Sun, W., Zhan, Z., & Wu, Y. (2026) · Biosensors · doi:10.3390/bios16090523
Alsharidah, R. S., Anwer, R., Abdelhamid, M. A., Alanazi, E. A., Alanazi, F. M., Alanazi, H. F., Alotaibi, J. N., Alshathri, L. A., Alshehri, R. A., Alsuhibani, R., et al. (2026) · Biosensors · doi:10.3390/bios16090521
Cao, M., Yu, S., Yuan, S., Yang, Y., Zhang, H., Song, J., Yan, X., Liu, J., Wang, Y., Li, W., et al. (2026) · Science China Materials · doi:10.1007/s40843-026-4333-8
A multimodal, parallel, wireless wearable sweat analysis system for real-time sports monitoring
Yin, Z., Li, J., Guo, L., Wang, Z., & Kang, Z. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.140970
Krishnamoorthy, P., & Rakkesh, R. A. (2026) · RSC Advances · doi:10.1039/d6ra06028e
Alhejaili, N. K. (2024) · Review of Contemporary Philosophy
Monolithically integrated in-textile patch for wireless epidermal biosensing
Ma, X. (n.d.) · PolyU Institutional Research Archive (Hong Kong Polytechnic University)
Liquid metal-based devices for energy harvesting and health monitoring through human sweat
Zhong, L. (n.d.) · PolyU Institutional Research Archive (Hong Kong Polytechnic University)
Nanotechnology-based wearable devices
Marin, A. M. (2022) · Rovira & Virgili repository
Human Sweat Cortisol Versus Blood and Saliva: Quantitative Interpretation
Albanese, L. (2026) · Methods and Protocols · doi:10.3390/mps9060154
Wu, Z., Liu, R., 邢少华, & Ba, L. (2026) · Analytica Chimica Acta · doi:10.1016/j.aca.2026.346438
Components Of Wearable Biosensors: A Biochemical Perspective On Real - Time Health Monitoring
Sulthana, S., & P, R. V. (2026) · INTERNATIONAL JOURNAL OF RESEARCH AND ANALYTICAL REVIEWS · doi:10.56975/ijrar.v13i2.335928
Advancing neonatal care through non-invasive biochemical monitoring and diagnostics
Son, H., Kim, D., Yeo, W. H., & Lim, H. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.119387
Neufeld, I. V., Kiselev, A. R., Zhirnyakov, A. I., Rogozhina, I. E., & Zhirnyakova, Y. R. (2026) · International Journal for Vitamin and Nutrition Research · doi:10.31083/ijvnr48515
Kumar, S., & Singh, N. K. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-36504-1.00005-0
Nagano, K., Manabe, K., Mori, I., 岡田, 康., Shimizu, E., & Naito, S. (2026) · PLoS ONE · doi:10.1371/journal.pone.0362451
Le, P. T., Yun, G., Hwang, T. S., Lee, H. W., Cho, H., Lee, J., & Lim, G. (2026) · Nature Communications · doi:10.1038/s41467-026-78755-8
Feng, S., Lee, Y. J., Kim, T., & Lee, Y. J. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.141230
Esmaeildoost, F., Arshadi, S., Rahimi, F., Najafpour, M., chian, M. F., Sachlos, E., Leung, S. N., & Salahandish, R. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.71983
Effects of Incubation Temperature, Time, and Media on Volatile Compound Profiles of Sweat
Nitchanpansri, J., Tungkijanansin, N., Sirinara, P., Kulsing, C., & Nhujak, T. (2026) · ChemistrySelect · doi:10.1002/slct.75049
Metadata
- Authors
- Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., & Naik, R.
- Affiliations
- University of Cincinnati (US)
- Procter & Gamble (United States) (US)
- United States Air Force Research Laboratory (US)
- Air Force Research Laboratory 5 711 Human Performance Wing, Human Effectiveness Directorate, , Wright-Patterson Air Force Base, Dayton, Ohio 45233, USA
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2015-05-01
- Volume
- 9
- Issue
- 3
- Pages
- 031301-031301
- ISSN
- 1932-1058 (ISSN-L)
- PMC
- PMC4433483
- OpenAlex
- W1548680965
- Cited by
- 724
- References
- 86
- Citations by year
- 2026: 57 · 2025: 80 · 2024: 96 · 2023: 84 · 2022: 76 · 2021: 79 · 2020: 84 · 2019: 60 · 2018: 55 · 2017: 30 · 2016: 20 · 2015: 2
- FWCI
- 17.72
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/3.0/ (vor, 14 d)
- creativecommons.org/licenses/by/3.0/ (tdm, 14 d)
- Locations
- Biomicrofluidics (publishedVersion, cc-by)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Center for Advanced Design and Manufacturing of Integrated Microfluidics (IIP-1362165)
- Air Force Office of Scientific Research (Summer Faculty Fellowship Program)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Keywords
- eccrine sweat glands, sweat biomarkers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.