The DOI matches its Crossref record; 86 of the 86 references it cites were found in a registry or an index.
The microfluidics of the eccrine sweat gland, including biomarker partitioning, transport, and biosensing implications
Open accessAbstract
Non-invasive and accurate access of biomarkers remains a holy grail of the biomedical community. Human eccrine sweat is a surprisingly biomarker-rich fluid which is gaining increasing attention. This is especially true in applications of continuous bio-monitoring where other biofluids prove more challenging, if not impossible. However, much confusion on the topic exists as the microfluidics of the eccrine sweat gland has never been comprehensively presented and models of biomarker partitioning into sweat are either underdeveloped and/or highly scattered across literature. Reported here are microfluidic models for eccrine sweat generation and flow which are coupled with review of blood-to-sweat biomarker partition pathways, therefore providing insights such as how biomarker concentration changes with sweat flow rate. Additionally, it is shown that both flow rate and biomarker diffusion determine the effective sampling rate of biomarkers at the skin surface (chronological resolution). The discussion covers a broad class of biomarkers including ions (Na+, Cl−, K+, NH4+), small molecules (ethanol, cortisol, urea, and lactate), and even peptides or small proteins (neuropeptides and cytokines). The models are not meant to be exhaustive for all biomarkers, yet collectively serve as a foundational guide for further development of sweat-based diagnostics and for those beginning exploration of new biomarker opportunities in sweat.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The relatively stable behaviour of [K+] is explained by its passive ion partitioning mechanism13.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [13]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The decreases in concentration of lactate and glucose in sweat are expected, owing to the dilution effect caused by an increase in sweat rate, which is visually observed as exercise continues13.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [13]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The accurate measurement of physiologically relevant sweat glucose concentrations with epidermal biosensors faces several major challenges related to uncontrolled operational conditions (e.g., varying temperature and pH), glucose contamination from various sources, irregular sampling rates, and low sampling volumes.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [64]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Detection of biomarkers from eccrine sweat glands pose tremendous advantages over those from urine, blood, tears, and apocrine sweat glands. These, include their abundance on the body (>100 glands/cm2), ease of access, sampling and detection efficiency without foreign contamination during testing, and the inability to degrade analytes19 (Table 3).”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [19]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The color change in the detection reservoir correlated with the concentration of lactate throughout the relevant range expected in sweat (1.5 to 100 mM) (Fig. 3C) (13, 46, 47).”
From A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat (2016) · cites this paper as [13]
Experimental — accuracy not yet measured
14 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrowetting: from basics to applications
Mugele, F., & Baret, J.-C. (2005) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/17/28/r01 · Cited by 2,092
Clinical Methods: The History, Physical, and Laboratory Examinations
Kruse, J. A. (1990) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1990.03450210108045 · Cited by 2,029
Handbook of Experimental Pharmacology.
Meakin, J. W. (1971) · Archives of Internal Medicine · doi:10.1001/archinte.1971.00310230151026 · Cited by 1,959
Salivary cortisol as a biomarker in stress research
Hellhammer, D. H., Wüst, S., & Kudielka, B. M. (2009) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2008.10.026 · Cited by 1,925
Salivary Cortisol in Psychobiological Research: An Overview
Kirschbaum, C., & Hellhammer, D. H. (2008) · Neuropsychobiology · doi:10.1159/000118611 · Cited by 1,532
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Diagnostic Potential of Saliva: Current State and Future Applications
Pfaffe, T., Cooper-White, J., Beyerlein, P., Kostner, K., & Punyadeera, C. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.153767 · Cited by 798
Biology of sweat glands and their disorders. I. Normal sweat gland function
Sato, K., Kang, W. H., Saga, K., & Sato, K. T. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70063-3 · Cited by 717
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Malaparte, C. (1988) · Cited by 601
Correlation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570
Bandodkar, A. J., Molinnus, D., Mirza, O., Guinovart, T., Windmiller, J. R., Valdés-Ramírez, G., Andrade, F. J., Schöning, M. J., & Wang, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.039 · Cited by 490
Taylor, N. A., & Machado-Moreira, C. A. (2013) · Extreme Physiology & Medicine · doi:10.1186/2046-7648-2-4 · Cited by 490
Saliva: an emerging biofluid for early detection of diseases.
Lee, Y. H., & Wong, D. T. (2009) · PubMed · Cited by 488
Variations in Regional Sweat Composition in Normal Human Males
Patterson, M. J., Galloway, S. D. R., & Nimmo, M. A. (2000) · Experimental Physiology · doi:10.1111/j.1469-445x.2000.02058.x · Cited by 438
Adhesive RFID Sensor Patch for Monitoring of Sweat Electrolytes
Rose, D. P., Ratterman, M. E., Griffin, D. K., Hou, L., Kelley-Loughnane, N., Naik, R. R., Hagen, J. A., Papautsky, I., & Heikenfeld, J. C. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2369991 · Cited by 416
Self-citationThe physiology, pharmacology, and biochemistry of the eccrine sweat gland
Sato, K. (1977) · Reviews of Physiology, Biochemistry and Pharmacology · doi:10.1007/bfb0037089 · Cited by 384
Smartphone based health accessory for colorimetric detection of biomarkers in sweat and saliva
Oncescu, V., O'Dell, D., & Erickson, D. (2013) · Lab on a Chip · doi:10.1039/c3lc50431j · Cited by 362
Detection of physiological concentrations of cortisol and cortisone in human hair
Raul, J.-S., Cirimele, V., Ludes, B., & Kintz, P. (2004) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.02.010 · Cited by 348
A potentiometric tattoo sensor for monitoring ammonium in sweat
Guinovart, T., Bandodkar, A. J., Windmiller, J. R., Andrade, F. J., & Wang, J. (2013) · The Analyst · doi:10.1039/c3an01672b · Cited by 343
A short history of sweat gland biology
Wilke, K., Martin, A., Terstegen, L., & Biel, S. S. (2007) · International Journal of Cosmetic Science · doi:10.1111/j.1467-2494.2007.00387.x · Cited by 334
BIOTEX—Biosensing Textiles for Personalised Healthcare Management
Coyle, S., Lau, K.-T., Moyna, N., O'Gorman, D., Diamond, D., Di Francesco, F., Costanzo, D., Salvo, P., Trivella, M. G., De Rossi, D. E., et al. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2038484 · Cited by 330
Use of saliva for monitoring unbound free cortisol levels in serum
Teruhisa, U., Ryoji, H., Taisuke, I., Tatsuya, S., Fumihiro, M., & Tatsuo, S. (1981) · Clinica Chimica Acta · doi:10.1016/0009-8981(81)90353-3 · Cited by 314
Gender-linked differences in human skin
Giacomoni, P. U., Mammone, T., & Teri, M. (2009) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2009.06.001 · Cited by 314
Bandage‐Based Wearable Potentiometric Sensor for Monitoring Wound pH
Guinovart, T., Valdés‐Ramírez, G., Windmiller, J. R., Andrade, F. J., & Wang, J. (2014) · Electroanalysis · doi:10.1002/elan.201300558 · Cited by 308
Testing for drugs of abuse in saliva and sweat
Kidwell, D. A., Holland, J. C., & Athanaselis, S. (1998) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(97)00572-0 · Cited by 300
Adeva, M. M., Souto, G., Blanco, N., & Donapetry, C. (2012) · Metabolism · doi:10.1016/j.metabol.2012.07.007 · Cited by 295
Lactate in human sweat: a critical review of research to the present day
Derbyshire, P. J., Barr, H., Davis, F., & Higson, S. P. J. (2012) · The Journal of Physiological Sciences · doi:10.1007/s12576-012-0213-z · Cited by 280
Plasma potassium changes with high intensity exercise.
Medbø, J. I., & Sejersted, O. M. (1990) · The Journal of Physiology · doi:10.1113/jphysiol.1990.sp017935 · Cited by 275
Wearable temporary tattoo sensor for real-time trace metal monitoring in human sweat
Kim, J., de Araujo, W. R., Samek, I. A., Bandodkar, A. J., Jia, W., Brunetti, B., Paixão, T. R. L. C., & Wang, J. (2015) · Electrochemistry Communications · doi:10.1016/j.elecom.2014.11.024 · Cited by 245
Sweat: A sample with limited present applications and promising future in metabolomics
Mena-Bravo, A., & Luque de Castro, M. D. (2014) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2013.10.048 · Cited by 235
Individual variations in structure and function of human eccrine sweat gland
Sato, K., & Sato, F. (1983) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1983.245.2.r203 · Cited by 215
Cizza, G., Marques, A. H., Eskandari, F., Christie, I. C., Torvik, S., Silverman, M. N., Phillips, T. M., & Sternberg, E. M. (2008) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.05.035 · Cited by 208
The Detection of Cortisol in Human Sweat: Implications for Measurement of Cortisol in Hair
Russell, E., Koren, G., Rieder, M., & Van Uum, S. H. M. (2014) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e31829daa0a · Cited by 193
Structure and function of human sweat glands studied with histochemistry and cytochemistry
Saga, K. (2002) · Progress in Histochemistry and Cytochemistry · doi:10.1016/s0079-6336(02)80005-5 · Cited by 192
Wearable textile biofuel cells for powering electronics
Jia, W., Wang, X., Imani, S., Bandodkar, A. J., Ramírez, J., Mercier, P. P., & Wang, J. (2014) · J. Mater. Chem. A · doi:10.1039/c4ta04796f · Cited by 184
EXCRETION OF SODIUM AND POTASSIUM IN HUMAN SWEAT 1
Schwartz, I. L., & Thaysen, J. H. (1956) · Journal of Clinical Investigation · doi:10.1172/jci103245 · Cited by 166
The Current Status of Sweat Testing For Drugs of Abuse: A Review
De Giovanni, N., & Fucci, N. (2013) · Current Medicinal Chemistry · doi:10.2174/092986713804910139 · Cited by 164
Micropuncture studies of the sweat formation in cystic fibrosis patients
Schulz, I. (1969) · Journal of Clinical Investigation · doi:10.1172/jci106113 · Cited by 155
Relationship between Lactate Concentrations in Active Muscle Sweat and Whole Blood
Sakharov, D. A., Shkurnikov, M. Y., Vagin, M. Y., Yashina, E. I., Karyakin, A. A., & Tonevitsky, A. (2010) · Bulletin of Experimental Biology and Medicine · doi:10.1007/s10517-010-1075-0 · Cited by 155
Analysis of metabolites in sweat as a measure of physical condition
Mitsubayashi, K., Suzuki, M., Tamiya, E., & Karube, I. (1994) · Analytica Chimica Acta · doi:10.1016/0003-2670(94)80004-9 · Cited by 153
Gamella, M., Campuzano, S., Manso, J., Rivera, G. G. D., López-Colino, F., Reviejo, A. J., & Pingarrón, J. M. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.09.020 · Cited by 140
Uric acid and urea in human sweat.
Huang, C.-T., Chen, M.-L., Huang, L., & Mao, I. (2002) · PubMed · Cited by 136
Marques-Deak, A., Cizza, G., Eskandari, F., Torvik, S., Christie, I. C., Sternberg, E. M., & Phillips, T. M. (2006) · Journal of Immunological Methods · doi:10.1016/j.jim.2006.07.011 · Cited by 129
The relationship between exercise intensity and the sweat lactate excretion rate
Buono, M. J., Lee, N. V. L., & Miller, P. W. (2010) · The Journal of Physiological Sciences · doi:10.1007/s12576-009-0073-3 · Cited by 128
Unraveling the molecular repertoire of tears as a source of biomarkers: Beyond ocular diseases
Pieragostino, D., D’Alessandro, M., di Ioia, M., Ilio, C. D., Sacchetta, P., & Boccio, P. D. (2014) · PROTEOMICS - CLINICAL APPLICATIONS · doi:10.1002/prca.201400084 · Cited by 122
The fine structure of human eccrine sweat glands
Hibbs, R. G. (1958) · American Journal of Anatomy · doi:10.1002/aja.1001030204 · Cited by 109
Rushmer, R. F., Buettner, K. J. K., Short, J. M., & Odland, G. F. (1966) · Science · doi:10.1126/science.154.3747.343 · Cited by 102
Neuropeptide Y and Related Peptides
Michel, M. C., & Al-Falah, M. (2004) · Handbook of experimental pharmacology · doi:10.1007/978-3-642-18764-3 · Cited by 97
Cholinergic potentiation of isoproterenol-induced cAMP level in sweat gland
Sato, K., & Sato, F. (1983) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1983.245.3.c189 · Cited by 89
Sweat urea, uric acid and creatinine concentrations in uraemic patients
Al‐Tamer, Y. Y., Hadi, E. A., & Al-Badrani, I. E. I. (1997) · Urological Research · doi:10.1007/bf01294662 · Cited by 88
Pharmacologic responsiveness of isolated single eccrine sweat glands
Sato, K., & Sato, F. (1981) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1981.240.1.r44 · Cited by 81
Sweat induction from an isolated eccrine sweat gland
Sato, K. (1973) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1973.225.5.1147 · Cited by 79
Sweat Ethanol Concentrations are Highly Correlated with Co‐Existing Blood Values in Humans
Buono, M. J. (1999) · Experimental Physiology · doi:10.1111/j.1469-445x.1999.01798.x · Cited by 74
Sweat lactate response between males with high and low aerobic fitness
Green, J. M., Pritchett, R. C., Crews, T. R., McLester, J. R., & Tucker, D. C. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0968-2 · Cited by 70
Sweat Lactate, Ammonia, and Urea in Rugby Players
Alvear-Ordenes, I., García-López, D., De Paz, J. A., & González-Gallego, J. (2005) · International Journal of Sports Medicine · doi:10.1055/s-2004-830380 · Cited by 67
The distribution, size and density of the apocrine glands in hidradenitis suppuritiva
Morgan, W. P., & Hughes, L. E. (1979) · British journal of surgery · doi:10.1002/bjs.1800661206 · Cited by 64
Mechanical properties and functions of the myoepithelium in the eccrine sweat gland
Sato, K., Nishiyama, A., & Kobayashi, M. (1979) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1979.237.3.c177 · Cited by 62
The Relationship Between Skin Hydration and the Suppression of Sweating1
Randall, W. C., & Peiss, C. N. (1957) · Journal of Investigative Dermatology · doi:10.1038/jid.1957.57 · Cited by 61
Effects of High and Low Blood Lactate Concentrations on Sweat Lactate Response
Green, J. M., Bishop, P. A., Muir, I. H., McLester Jr, J. R., & Heath, H. E. (2000) · International Journal of Sports Medicine · doi:10.1055/s-2000-8483 · Cited by 60
Nanoparticle Technology: Addressing the Fundamental Roadblocks to Protein Biomarker Discovery
Luchini, A., Fredolini, C., Espina, B., Meani, F., Reeder, A., Rucker, S., Petricoin, E. F., & Liotta, L. A. (2010) · Current Molecular Medicine · doi:10.2174/156652410790963268 · Cited by 59
Surface topography and contact mechanics of dry and wet human skin
Kovalev, A. E., Dening, K., Persson, B. N. J., & Gorb, S. N. (2014) · Beilstein Journal of Nanotechnology · doi:10.3762/bjnano.5.147 · Cited by 57
The concentration of sodium in thermal sweat
Bulmer, M. G., & Forwell, G. D. (1956) · The Journal of Physiology · doi:10.1113/jphysiol.1956.sp005506 · Cited by 56
Hydration of the Skin and Its Effect on Sweating and Evaporative Water Loss*
Peiss, C. N., Randall, W. C., & Hertzman, A. B. (1956) · Journal of Investigative Dermatology · doi:10.1038/jid.1956.62 · Cited by 55
Artificial microfluidic skin for in vitro perspiration simulation and testing
Hou, L., Hagen, J. A., Wang, X., Papautsky, I., Naik, R. K., Kelley‐Loughnane, N., & Heikenfeld, J. C. (2013) · Lab on a Chip · doi:10.1039/c3lc41231h · Cited by 55
Self-citationLiquid Transport in the Networked Microchannels of the Skin Surface
Dussaud, A. D., Adler, P. M., & Lips, A. (2003) · Langmuir · doi:10.1021/la034235a · Cited by 51
Plasma ammonia is the principal source of ammonia in sweat
Czarnowski, D., Górski, J., Jóźwiuk, J., & Boroń-Kaczmarska, A. (1992) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00705070 · Cited by 48
The Elimination of Ethyl Alcohol in Sweat1
Nyman, E., & Palmlöv, A. (1936) · Skandinavisches Archiv Für Physiologie · doi:10.1111/j.1748-1716.1936.tb01150.x · Cited by 47
Sweat lactate secretion during exercise in relation to women's aerobic capacity
Lamont, L. S. (1987) · Journal of Applied Physiology · doi:10.1152/jappl.1987.62.1.194 · Cited by 46
Grimnes, S., Jabbari, A., Martinsen, Ø. G., & Tronstad, C. (2010) · Skin Research and Technology · doi:10.1111/j.1600-0846.2010.00459.x · Cited by 45
Sweat ammonia excretion during submaximal cycling exercise
Czarnowski, D., & Górski, J. (1991) · Journal of Applied Physiology · doi:10.1152/jappl.1991.70.1.371 · Cited by 42
Newmark, S. R., & Dluhy, R. G. (1975) · JAMA · doi:10.1001/jama.1975.03240180065023 · Cited by 40
Tronstad, C., Kalvøy, H., Grimnes, S., & Martinsen, Ø. G. (2013) · Psychophysiology · doi:10.1111/psyp.12092 · Cited by 38
Clinical and Basic Immunodermatology
Gaspari, A. A. (2008) · Springer eBooks · doi:10.1007/978-1-84800-165-7 · Cited by 38
Urea transfer across the sweat glands
Komives, G. K., Robinson, S., & Roberts, J. T. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.6.1681 · Cited by 33
Dye Clearance and Eccrine Sweat Secretion in Human Skin*
Hurley, H. J., & Witkowski, J. A. (1961) · Journal of Investigative Dermatology · doi:10.1038/jid.1961.44 · Cited by 32
Exercise lactate levels: simulation and reality of aerobic and anaerobic metabolism
von DUVILLARD, S. P. (2001) · European Journal of Applied Physiology · doi:10.1007/s004210100515 · Cited by 23
Improved Estimation of Sweating Based on Electrical Properties of Skin
Tronstad, C., Kalvøy, H., Grimnes, S., & Martinsen, Ø. G. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0743-4 · Cited by 20
The concentration of urea in thermal sweat
Bulmer, M. G. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005810 · Cited by 20
The Surface Tension of Human Sweat; Its Determination and Its Significance*
Randall, W. C., & Calman, C. (1954) · Journal of Investigative Dermatology · doi:10.1038/jid.1954.90 · Cited by 17
Cyclic Fluctuation of Sweat Electrolytes in Women: Effect of Polythiazide Upon Sweat Electrolytes
Lieberman, J. (1966) · JAMA · doi:10.1001/jama.1966.03100080069018 · Cited by 14
Some characteristics of adrenergic human eccrine sweating
Sato, F., Burgers, M. L., & Sato, K. (1974) · Cellular and Molecular Life Sciences · doi:10.1007/bf01921584 · Cited by 14
Development of a medical device for long-term sweat activity measurements
Tronstad, C., Grimnes, S., Martinsen, Ø. G., & Fosse, E. T. (2007) · Springer eBooks · doi:10.1007/978-3-540-73841-1_63 · Cited by 8
Localization of Urea Transporters UT‐A1 and UT‐B in Human Eccrine Clear Cell (LB719)
Keller, R. W., & Sands, J. M. (2014) · The FASEB Journal · doi:10.1096/fasebj.28.1_supplement.lb719 · Cited by 6
Research works printed but not linked: 10
- 1977, Reviews of Physiology, Biochemistry and Pharmacology, 51
- C. Tronstad , “ Developments in biomedical sensors based on electrical impedance,” Doctor Philosophiae thesis ( University of Oslo, 2012).
- T. A. Peyser , R. O.Potts, H. L.Berman, J. W.Moyer, and M. A.Kouchnir, “ Devices, methods, and kits for non-invasive glucose measurement,” U.S. patent 7,725,149 (2010).
- 1993, The mechanism of eccrine sweat secretion, Perspect. Exercise Sci. Sports Med., 6, 85
- 2008, Theoretical Microfluidics, 346
- 2011, Medical Physiology: A Cellular and Molecular Approach
- 1999, Fitzpatrick's Dermatology in General Medicine
- 2000, Salivary cortisol, Encycl. Stress, 3, 379
- 2011, Peptides and proteins in pharmaceuticals, Int. J. Curr. Pharm. Res., 3, 1
- See supplementary material at http://dx.doi.org/10.1063/1.4921039E-BIOMGB-9-002503 for the derivation of the solute transport equation and sampling rate limitations for biosensors. · doi:10.1063/1.4921039e-biomgb-9-002503
Cited by
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
“analyte for pH, mineral ion, glucose, water, lactic acid, and urea concentrations.(35) Additionally,”
BackgroundInfluentialBariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Self-citation
Metadata
- Authors
- Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., & Naik, R.
- Affiliations
- University of Cincinnati (US)
- Procter & Gamble (United States) (US)
- United States Air Force Research Laboratory (US)
- Air Force Research Laboratory 5 711 Human Performance Wing, Human Effectiveness Directorate, , Wright-Patterson Air Force Base, Dayton, Ohio 45233, USA
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2015-05-01
- Volume
- 9
- Issue
- 3
- Pages
- 031301-031301
- ISSN
- 1932-1058 (ISSN-L)
- PMC
- PMC4433483
- OpenAlex
- W1548680965
- Cited by
- 724
- References
- 86
- Citations by year
- 2026: 57 · 2025: 80 · 2024: 96 · 2023: 84 · 2022: 76 · 2021: 79 · 2020: 84 · 2019: 60 · 2018: 55 · 2017: 30 · 2016: 20 · 2015: 2
- FWCI
- 17.72
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/3.0/ (vor, 14 d)
- creativecommons.org/licenses/by/3.0/ (tdm, 14 d)
- Locations
- Biomicrofluidics (publishedVersion, cc-by)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Center for Advanced Design and Manufacturing of Integrated Microfluidics (IIP-1362165)
- Air Force Office of Scientific Research (Summer Faculty Fellowship Program)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Keywords
- eccrine sweat glands, sweat biomarkers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.