The microfluidics of the eccrine sweat gland, including biomarker partitioning, transport, and biosensing implications
Open accessThe DOI matches its Crossref record; 86 of the 86 references it cites were found in a registry or an index.
Abstract
Non-invasive and accurate access of biomarkers remains a holy grail of the biomedical community. Human eccrine sweat is a surprisingly biomarker-rich fluid which is gaining increasing attention. This is especially true in applications of continuous bio-monitoring where other biofluids prove more challenging, if not impossible. However, much confusion on the topic exists as the microfluidics of the eccrine sweat gland has never been comprehensively presented and models of biomarker partitioning into sweat are either underdeveloped and/or highly scattered across literature. Reported here are microfluidic models for eccrine sweat generation and flow which are coupled with review of blood-to-sweat biomarker partition pathways, therefore providing insights such as how biomarker concentration changes with sweat flow rate. Additionally, it is shown that both flow rate and biomarker diffusion determine the effective sampling rate of biomarkers at the skin surface (chronological resolution). The discussion covers a broad class of biomarkers including ions (Na+, Cl−, K+, NH4+), small molecules (ethanol, cortisol, urea, and lactate), and even peptides or small proteins (neuropeptides and cytokines). The models are not meant to be exhaustive for all biomarkers, yet collectively serve as a foundational guide for further development of sweat-based diagnostics and for those beginning exploration of new biomarker opportunities in sweat.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The relatively stable behaviour of [K+] is explained by its passive ion partitioning mechanism13.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [13]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The decreases in concentration of lactate and glucose in sweat are expected, owing to the dilution effect caused by an increase in sweat rate, which is visually observed as exercise continues13.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [13]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The accurate measurement of physiologically relevant sweat glucose concentrations with epidermal biosensors faces several major challenges related to uncontrolled operational conditions (e.g., varying temperature and pH), glucose contamination from various sources, irregular sampling rates, and low sampling volumes.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [64]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Detection of biomarkers from eccrine sweat glands pose tremendous advantages over those from urine, blood, tears, and apocrine sweat glands. These, include their abundance on the body (>100 glands/cm2), ease of access, sampling and detection efficiency without foreign contamination during testing, and the inability to degrade analytes19 (Table 3).”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [19]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The color change in the detection reservoir correlated with the concentration of lactate throughout the relevant range expected in sweat (1.5 to 100 mM) (Fig. 3C) (13, 46, 47).”
From A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat (2016) · cites this paper as [13]
Experimental — accuracy not yet measured
14 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrowetting: from basics to applications
Mugele, F., & Baret, J.-C. (2005) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/17/28/r01 · Cited by 2,092
Clinical Methods: The History, Physical, and Laboratory Examinations
Kruse, J. A. (1990) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1990.03450210108045 · Cited by 2,029
Handbook of Experimental Pharmacology.
Meakin, J. W. (1971) · Archives of Internal Medicine · doi:10.1001/archinte.1971.00310230151026 · Cited by 1,959
Salivary cortisol as a biomarker in stress research
Hellhammer, D. H., Wüst, S., & Kudielka, B. M. (2009) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2008.10.026 · Cited by 1,925
Salivary Cortisol in Psychobiological Research: An Overview
Kirschbaum, C., & Hellhammer, D. H. (2008) · Neuropsychobiology · doi:10.1159/000118611 · Cited by 1,532
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Diagnostic Potential of Saliva: Current State and Future Applications
Pfaffe, T., Cooper-White, J., Beyerlein, P., Kostner, K., & Punyadeera, C. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.153767 · Cited by 798
Biology of sweat glands and their disorders. I. Normal sweat gland function
Sato, K., Kang, W. H., Saga, K., & Sato, K. T. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70063-3 · Cited by 717
Research works printed but not linked: 10
- 1977, Reviews of Physiology, Biochemistry and Pharmacology, 51
- C. Tronstad , “ Developments in biomedical sensors based on electrical impedance,” Doctor Philosophiae thesis ( University of Oslo, 2012).
- T. A. Peyser , R. O.Potts, H. L.Berman, J. W.Moyer, and M. A.Kouchnir, “ Devices, methods, and kits for non-invasive glucose measurement,” U.S. patent 7,725,149 (2010).
- 1993, The mechanism of eccrine sweat secretion, Perspect. Exercise Sci. Sports Med., 6, 85
- 2008, Theoretical Microfluidics, 346
- 2011, Medical Physiology: A Cellular and Molecular Approach
- 1999, Fitzpatrick's Dermatology in General Medicine
- 2000, Salivary cortisol, Encycl. Stress, 3, 379
- 2011, Peptides and proteins in pharmaceuticals, Int. J. Curr. Pharm. Res., 3, 1
- See supplementary material at http://dx.doi.org/10.1063/1.4921039E-BIOMGB-9-002503 for the derivation of the solute transport equation and sampling rate limitations for biosensors. · doi:10.1063/1.4921039e-biomgb-9-002503
Cited by
Items 601–700 of 782
Wearable and implantable aptamer sensors for physiological monitoring
Lee, H. B., Lee, D., & Ko, S. H. (2026) · Soft Science · doi:10.20517/ss.2025.149 · Cited by 3
Drexelius, A., Yuan, Y., Friedel, M., DeBrosse, M. C., & Heikenfeld, J. C. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-821661-3.00001-x · Cited by 3
Self-citationDevelopment of wrist‐watch type biosensing system for real‐time sweat lactate monitoring
Konno, S., & Kudo, H. (2023) · Electronics and Communications in Japan · doi:10.1002/ecj.12408 · Cited by 3
Wearable noninvasive glucose sensors based on graphene and other carbon materials
Antonova, I. V., & Ivanov, A. I. (2023) · Uspekhi Fizicheskih Nauk · doi:10.3367/ufnr.2023.08.039541 · Cited by 3
Li, S., Mao, Q., Mao, Q., Song, X., Zhou, J., Ma, W., Lan, C., & Li, M. (2024) · Journal of Photochemistry and Photobiology A Chemistry · doi:10.1016/j.jphotochem.2024.116090 · Cited by 3
Using Screen Printing Technology to Fabricate Flexible Sodium Ion Sensors
Wang, F.-H., Huang, S.-W., Yang, C., & Min, K.-W. (2025) · Sensors · doi:10.3390/s25123650 · Cited by 3
Can Sweat Sensors Detect Common Diseases? A Simple Sweat Patch May Soon Achieve It
Christodouleas, D. C. (2019) · Clinical Chemistry · doi:10.1373/clinchem.2019.303321 · Cited by 3
Digital biomarkers from sweat analysis for therapeutic drug monitoring in soft tissue infections
Brasier, N., Widmer, A. F., Osthoff, M. F., & Eckstein, J. (2021) · doi:10.1145/3469266.3471179 · Cited by 3
Smart biomaterials for skin tissue engineering and health monitoring
Martín, C., Medina, D. M., Matesanz, A., de Velasco, D. A. O.-G., Acedo, P., & Jorcano, J. L. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-85671-3.00010-5 · Cited by 3
Wearable Transdermal Biosensors
Rao, G., Srinivasan, V., Sheffield, Z., Ahuja, P., Kumar, S., Ge, X., Dighe, K., & Sundberg, C. A. (2024) · Springer eBooks · doi:10.1007/978-981-99-8122-9_5 · Cited by 3
Mind the Gap: Wearable Lactate and Glucose Monitors for Hospitalized Patients
Guzzi, J., Falter, F., Kumar, A. B., & Perrino, A. C. (2025) · Cureus · doi:10.7759/cureus.78536 · Cited by 3
Yin, X., Adelaars, S., Peri, E., Pelssers, E., den Toonder, J. M. J., Bouwman, R. A., van de Kerkhof, D., & Mischi, M. (2025) · Frontiers in Physiology · doi:10.3389/fphys.2025.1547117 · Cited by 3
Embedded passive nano-liter micropump for sweat collection and analysis
Garcia-Cordero, E., Wildhaber, F., Bellando, F., Longo, J., Fernández-Bolaños, M., Guérin, H., & Ionescu, A. M. (2018) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2018.8346782 · Cited by 3
Steijlen, A. S. M., Bastemeijer, J., Groen, P., Jansen, K. M. B., French, P. J., & Bossche, A. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176123 · Cited by 3
Design of a Calorimetric Flow Rate Sensor for On-Body Sweat Monitoring
Thirumalaikumar, S., Douthwaite, M., & Georgiou, P. (2021) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas51556.2021.9401411 · Cited by 3
Wearable noninvasive glucose sensors based on graphene and other carbon materials
Antonova, I. V., & Ivanov, A. I. (2023) · Physics-Uspekhi · doi:10.3367/ufne.2023.08.039541 · Cited by 3
Flexible and printed biosensors based on organic TFT devices
Nagamine, K., & Tokito, S. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815409-0.00020-6 · Cited by 3
Stretchable interconnects for smart integration of sensors in wearable and robotic applications
Dang, W. (2018) · Enlighten: Theses (The University of Glasgow) · Cited by 3
Wearable Carbon Nanotube Sensors: Fabrication and Applications for Bio/Chemical Sensors
Kahng, S. (2019) · ResearchWorks at the University of Washington (University of Washington) · Cited by 3
Li, Y., Liu, Y., Leach, M. P., Hoettges, K. F., Zhang, Q., & Song, P. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3575581 · Cited by 2
Esposito, V., Sciurti, E., Calogiuri, A., Bellisario, D., Velardi, L., Casino, F., Blasi, L., & Francioso, L. N. (2025) · Measurement Sensors · doi:10.1016/j.measen.2025.101977 · Cited by 2
Shan, L., Guo, C. Q., Sun, Y., Liu, M., Chen, J., Wang, Q., & Fan, W. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.116710 · Cited by 2
Hu, Y., Zhou, X., & Yang, Z. (2026) · Microchemical Journal · doi:10.1016/j.microc.2026.117414 · Cited by 2
Islam, M. J., & Chowdhury, M. I. B. (2026) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.6c00117 · Cited by 2
Memon, R., Tufani, A., Çelik, S., Niazi, J. H., & Qureshi, A. (2026) · Advanced Materials Technologies · doi:10.1002/admt.70991 · Cited by 2
Umapathi, K. (2026) · Analytical Methods · doi:10.1039/d6ay00459h · Cited by 2
Chen, Z. Y., Cai, Y., Zhang, S., Zhou, Y., Wei, Y., Li, J., Xu, R., Gai, Y., Ye, X., Zhou, C., et al. (2026) · Advanced Materials Technologies · doi:10.1002/admt.71086 · Cited by 2
Noninvasive measurement of glucose and lactate in thermoregulatory sweat in neonates and adults
Liu, X., Gowers, S. A. N., Gourin, B., McClure, Z. E., Dado, S., Abraham, T., Banerjee, J., & Boutelle, M. G. (2026) · Science Advances · doi:10.1126/sciadv.aec4166 · Cited by 2
Chen, H., & Chen, C. (2026) · Micromachines · doi:10.3390/mi17070863 · Cited by 2
A flexible GOx/PB/Au film biosensor for the detection of glucose
Cai, K., Bao, Y., Liu, Y., & Li, B. (2024) · Electroanalysis · doi:10.1002/elan.202400092 · Cited by 2
Molecular Dynamics Model for Developing Wearable Biosensors
Deshpande, P., Kumar, D., Badhe, Y. P., & Rai, B. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10782196 · Cited by 2
Sweating disorders in mice with and without nerve lesions
Guhl, C., Birklein, F., & Hirsch, S. J. (2018) · European Journal of Pain · doi:10.1002/ejp.1352 · Cited by 2
Biomedical Applications of Polysaccharide-Based Aerogels: A Review
Warrier, S. K., Mathew, S. S., Pothan, L. A., & Ajish, K. R. (2022) · Current Applied Polymer Science · doi:10.2174/2452271605666220929151916 · Cited by 2
Silverio, A. A., Ho, E. T. W., Ang, J., & Esguerra, K. (2024) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ad2305 · Cited by 2
Wearable Sweat Sensors: A Review
Chowdhury, I., Ali, M. Y., & Howlader, M. M. R. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95478-5.00015-7 · Cited by 2
Integrated flexible sensors with amplifier circuit for pH and temperature analysis
Liu, G., Shu, X., Li, J., Xu, T., Sui, C., Zhang, S., & Yang, R. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.117024 · Cited by 2
Emerging wearable technologies for personalized health and performance monitoring
Emaminejad, S., Pilehvar, S., Wilhelm, A., Wilhelm, A., & King, K. (2018) · Micro- and Nanotechnology Sensors, Systems, and Applications · doi:10.1117/12.2305693 · Cited by 2
Minimally Invasive Technologies for Biosensing
Zhang, S., Lee, K., Goudie, M. J., Kim, H., Sun, W., Lee, J., Chen, Y., Ling, H., Li, Z., Benyshek, C., et al. (2020) · Springer eBooks · doi:10.1007/978-3-030-34467-2_9 · Cited by 2
Wearable Fabric Based-Biosensor for Ion Detection in Sweat
Busono, P., Wijaya, J., Handoyo, T., & Astawa, I. M. (2022) · International Conference on Radar, Antenna, Microwave, Electronics, and Telecommunications (ICRAMET) · doi:10.1109/icramet56917.2022.9991227 · Cited by 2
Wearable and Flexible Fibrosis Cystic Tag with Potentiometric Chloride Activity Sensing
Venuto, D. D., Mezzina, G., Tricase, A., Bollella, P., Mascellaro, G., & Torsi, L. (2023) · International Workshop on Advances in Sensors and Interfaces (IWASI) · doi:10.1109/iwasi58316.2023.10164336 · Cited by 2
Printed Wearable Electrochemical Sensors for Healthcare Monitoring
Bandodkar, A. J. (2016) · eScholarship (California Digital Library) · Cited by 2
Wearable Sensors and Deep Learning for the Management of Acute Pancreatitis in Precision Medicine
Liu, Q., Jiang, Y., Yu, R., & Poon, C. C. Y. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00068-6 · Cited by 3
Zörner, A. (2021) · OPUS FAU (Kooperativer Bibliotheksverbund Berlin-Brandenburg (KOBV), on behalf of the Universitätsbibliothek Erlangen-Nürnberg) · Cited by 2
Shitanda, I., Takamatsu, K., Yoshihata, Y., Nakamura, T., Mikawa, T., Itagaki, M., & Tsujimura, S. (2020) · Chemistry Letters · doi:10.1246/cl.200799 · Cited by 1
Wearable Technology for Assessment and Surgical Assistance in Minimally Invasive Surgery
Sánchez‐Margallo, J. A., Rabazo, J. C., de Miguel, C. P., Gloor, P. A., Rey, D., González-Portillo, M. R., López-Agudelo, I., & Sanchez-Margallo, F. M. (2022) · IntechOpen eBooks · doi:10.5772/intechopen.100617 · Cited by 1
Development of Wrist-watch Type Biosensing System for Real-time Sweat Lactate Monitoring
Konno, S., & Kudo, H. (2023) · IEEJ Transactions on Sensors and Micromachines · doi:10.1541/ieejsmas.143.42 · Cited by 1
Skin-derived biofluid sampling for analytical approaches
Sekine, Y., & Oikawa, D. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15978-7.00034-5 · Cited by 1
García-Rodríguez, W., Saavedra-Ruiz, A., & Resto, P. J. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10781841 · Cited by 1
Park, J. H., Park, H. J., Jang, S. T., Kim, J., Yoon, J. H., Lee, K. G., & Choi, B. G. (2025) · Physica Scripta · doi:10.1088/1402-4896/adab3f · Cited by 1
Lv, F., Zhao, R., Chen, Z., Wang, S., Huang, Y., & Wang, L. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116245 · Cited by 1
Jung, Y., Park, J., Shin, S., Kim, S.-H., Maskey, B. B., Shrestha, K. P., Ding, J., Tran, T. T. V., Malenfant, P. R. L., Lee, J., et al. (2025) · Small · doi:10.1002/smll.202409949 · Cited by 1
Wearable self-driven (In,Ga)N sensor for biosensing application
Hu, S., Hou, B., Zhang, J., Huang, Y., & Zhao, Y. (2025) · Chinese Optics Letters · doi:10.3788/col202523.082502 · Cited by 1
A Wearable Graphene-Based Sweat Sensor for Real-Time Health Monitoring
Ballam, L. R., Bidsorkhi, H. C., D’Aloia, A. G., & Sarto, M. S. (2025) · IEEE Sensors Letters · doi:10.1109/lsens.2025.3606010 · Cited by 1
Development of wearable thermal MEMS sensor for sweat-rate measurement
YOSHIZAWA, H., YASUDA, H., ICHIKAWA, Y., Mukaimoto, T., Yanagita, S., Suzuki, T., Shitanda, I., & Motosuke, M. (2025) · Journal of Thermal Science and Technology · doi:10.1299/jtst.25-00222 · Cited by 1
Lázaro, A., Rodriguez, E. R., Lázaro, M., Villarino, R., González, B., & Girbau, D. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3645137 · Cited by 1
Huang, T., Li, L., Liang, J., Zhu, Z., Yang, Z., & Xi, Y. (2026) · Analytical Methods · doi:10.1039/d5ay01980j · Cited by 1
Luo, X., Ling, X., Li, X., Wang, Z., & Hu, X. (2026) · ACS Applied Polymer Materials · doi:10.1021/acsapm.5c04604 · Cited by 1
Zhang, D., Zhang, J., Jing, Q., Jeswani, R., Wade, T., & Kar‐Narayan, S. (2026) · APL Electronic Devices · doi:10.1063/5.0320597 · Cited by 1
Mei, J., Yang, Q., Tian, M., Deng, S., & Gong, Y. (2026) · Journal of Intensive Medicine · doi:10.1016/j.jointm.2026.03.004 · Cited by 1
Mimicking Human Perspiration: A Layered Microfluidic Skin Phantom With Tunable Hydrodynamics
Yang, C., Rodríguez-Villarreal, A. I., Martínez, J. A. L., Farré‐Lladós, J., Rabost-Garcia, G., & Casals‐Terré, J. (2026) · Advanced Materials Interfaces · doi:10.1002/admi.70545 · Cited by 1
Pan, Y., Huang, J., Chen, Z., Zhang, Z., Vasić, Ž. L., Cifrek, M., 刘爱林, & Gao, Y. (2026) · Talanta · doi:10.1016/j.talanta.2026.130080 · Cited by 1
Kang, D.-H., Peitzsch, A. G., Kong, Y., Jimenez-Wong, C., Lee, Y., Abraham, Z. A., Florian, J. P. A., & Chon, K. H. (2026) · Materials & Design · doi:10.1016/j.matdes.2026.116359 · Cited by 1
Pang, J. (2026) · Biomedical Chromatography · doi:10.1002/bmc.70574 · Cited by 1
Kızılkurtlu, A. A., & Akpek, A. (2026) · Biosensors · doi:10.3390/bios16080448 · Cited by 1
Cortisol Dynamics at High Temporal Resolution For Wearable Biosensor Research
Ferdoushi, M., Billings, T., Cai, W., & Khan, Y. (2026) · Advanced Sensor Research · doi:10.1002/adsr.70212 · Cited by 1
Fraga, J. C. D. L. T., & Mesa‐Álvarez, L. (2016) · Piel · doi:10.1016/j.piel.2015.10.009 · Cited by 1
Sonner, Z. (2017) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 1
Self-citationEnabling sweat-based biosensors:Solving the problem of low biomarker concentration in sweat
Jajack, A. J. (2018) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 1
An Asynchronous Auto-biasing Circuit for Wearable Electrochemical Sensors
Douthwaite, M., & Georgiou, P. (2018) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2018.8584833 · Cited by 1
Multiplexed Biochemical and Biophysical Sensing Systems for Monitoring Human Physiology.
Yokus, M. A. (2020) · NCSU Libraries Repository (North Carolina State University Libraries) · Cited by 1
Boisa, N. (2016) · Jordan Journal of Chemistry · Cited by 1
Jiang, Y., Jin, H., Dong, C., & Qin, Y. (2021) · IEEE International Conference on ASIC (ASICON) · doi:10.1109/asicon52560.2021.9620341 · Cited by 1
Updates of Wearing Devices (WDs) In Healthcare, And Disease Monitoring
Naser, M., Nasr, M., & Shehata, L. H. (2023) · International Journal of Progressive Sciences and Technologies · doi:10.52155/ijpsat.v39.1.5361 · Cited by 1
Watkins, Z., McHenry, A., & Heikenfeld, J. C. (2023) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2023_238 · Cited by 1
Self-citationSample preparation using microfluidic technologies for non-invasive tests
Oksuz, C., Tarim, E. A., Ozcan, H. A., Koc, S., & Tekin, H. C. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15978-7.00038-2 · Cited by 1
Evolution and Impact of Wearable Devices in Healthcare
Ambali, M. P., & Patil, V. C. (2024) · Wiley eBooks · doi:10.1002/9781394272266.ch13 · Cited by 1
Asadi, M., Arab, N., Hosseini, M., Berdimurodov, E. T., & Ganjali, M. R. (2025) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2025.09.007 · Cited by 1
Dalirirad, S. (2020) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 1
Wearable Electrochemical Biosensors for Healthcare Monitoring Applications
Kim, J. (2018) · eScholarship (California Digital Library) · Cited by 1
Wearable System for Real-Time Sensing of Biomarkers in Human Sweat
Zhang, J. (2019) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · doi:10.5075/epfl-thesis-9696 · Cited by 1
Do not sweat it: we test while you rest and other updates on recent autonomic research
Miglis, M. G., Larsen, N. W., & Muppidi, S. (2021) · Clinical Autonomic Research · doi:10.1007/s10286-021-00811-8 · Cited by 1
Graphene biosensors for healthcare and food spoilage monitoring
Parate, K. (2021) · Iowa State University Digital Repository (Iowa State University) · doi:10.31274/etd-20210609-142 · Cited by 1
Electrochemical Wearable Devices
Lee, B. H., & Daniele, M. A.-A. (2021) · Wiley eBooks · doi:10.1002/9783527610426.bard030113 · Cited by 1
Correlating the Effect of Dynamic Variability in the Sensor Environment on Sensor Design
Bhushan, P. (2021) · FIU - Digital Commons (Florida International University) · doi:10.25148/etd.fidc009698 · Cited by 1
Optimization in electrochemistry
Parr, D. L. (2022) · Iowa Research Online (The University of Iowa) · doi:10.25820/etd.006885 · Cited by 1
Laborie, E. (2021) · theses.fr (ABES) · doi:10.70675/b6bfae86zb344z4e7bz8581z483b70c63f21 · Cited by 1
Chen, W. (2017) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/70775
Garcia, S. O., Ulyanova, Y., Figueroa-Teran, R., Bhatt, K. H., Singhal, S., & Atanassov, P. B. (2016)
Ren, X. (2017) · OhioLink ETD Center (Ohio Library and Information Network)
Development of a Non-enzymatic, Non-invasive Sensor for Detection of Lactate in Sweat
ljungh, A. (2018) · Chalmers Publication Library (Chalmers University of Technology)
Editorial: Farewell from the Founding and Chief Editor of Biomicrofluidics
Chang, H. (2018) · Biomicrofluidics · doi:10.1063/1.5084549
Towards Novel Human Sweat Sensors
dos Santos, B. M. C. (2019) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/ksqm-d978
Lv, H.-W., Li, Q.-F., & Peng, H. (2020) · International Journal of Electrochemical Science · doi:10.20964/2020.09.76
Epidermal sensors for monitoring skin physiology
Guzman, D., & Erika, A. K. (2020) · Dublin City University Open Access Institutional Repository (Dublin City University)
LCMS Measurement of Steroid Biomarkers Collected from Palmar Sweat.Preprint
Hyde, J., & Runyon, J. R. (2020) · ChemRxiv · doi:10.26434/chemrxiv.12931769.v1
Soft mechanical and biochemical sensors
Koh, A. S., & Vikas, V. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819246-7.00004-8
Migliorini, L. (2020) · Archivio Istituzionale della Ricerca (Universita Degli Studi Di Milano) · doi:10.13130/migliorini-lorenzo_phd2020-01-30
Nagamine, K., & Tokito, S. (2020) · Denki Kagaku · doi:10.5796/denkikagaku.20-fe0031
Suhendar, D., Yunita, Y., Andrian, R., Ayun, H., Aliah, H., Sudiart, T., & Supriadin, A. (2020) · International Conference on Islam, Science and Technology (ICONISTECH) · doi:10.4108/eai.11-7-2019.2297439
Status and Future Prospect of Sweat Lactate Monitoring System (Review)
Kudo, H. (2021) · IEEJ Transactions on Sensors and Micromachines · doi:10.1541/ieejsmas.141.83
Metadata
- Authors
- Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., & Naik, R.
- Affiliations
- University of Cincinnati (US)
- Procter & Gamble (United States) (US)
- United States Air Force Research Laboratory (US)
- Air Force Research Laboratory 5 711 Human Performance Wing, Human Effectiveness Directorate, , Wright-Patterson Air Force Base, Dayton, Ohio 45233, USA
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2015-05-01
- Volume
- 9
- Issue
- 3
- Pages
- 031301-031301
- ISSN
- 1932-1058 (ISSN-L)
- PMC
- PMC4433483
- OpenAlex
- W1548680965
- Cited by
- 724
- References
- 86
- Citations by year
- 2026: 57 · 2025: 80 · 2024: 96 · 2023: 84 · 2022: 76 · 2021: 79 · 2020: 84 · 2019: 60 · 2018: 55 · 2017: 30 · 2016: 20 · 2015: 2
- FWCI
- 17.72
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/3.0/ (vor, 14 d)
- creativecommons.org/licenses/by/3.0/ (tdm, 14 d)
- Locations
- Biomicrofluidics (publishedVersion, cc-by)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Center for Advanced Design and Manufacturing of Integrated Microfluidics (IIP-1362165)
- Air Force Office of Scientific Research (Summer Faculty Fellowship Program)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Keywords
- eccrine sweat glands, sweat biomarkers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.