The microfluidics of the eccrine sweat gland, including biomarker partitioning, transport, and biosensing implications
Open accessThe DOI matches its Crossref record; 86 of the 86 references it cites were found in a registry or an index.
Abstract
Non-invasive and accurate access of biomarkers remains a holy grail of the biomedical community. Human eccrine sweat is a surprisingly biomarker-rich fluid which is gaining increasing attention. This is especially true in applications of continuous bio-monitoring where other biofluids prove more challenging, if not impossible. However, much confusion on the topic exists as the microfluidics of the eccrine sweat gland has never been comprehensively presented and models of biomarker partitioning into sweat are either underdeveloped and/or highly scattered across literature. Reported here are microfluidic models for eccrine sweat generation and flow which are coupled with review of blood-to-sweat biomarker partition pathways, therefore providing insights such as how biomarker concentration changes with sweat flow rate. Additionally, it is shown that both flow rate and biomarker diffusion determine the effective sampling rate of biomarkers at the skin surface (chronological resolution). The discussion covers a broad class of biomarkers including ions (Na+, Cl−, K+, NH4+), small molecules (ethanol, cortisol, urea, and lactate), and even peptides or small proteins (neuropeptides and cytokines). The models are not meant to be exhaustive for all biomarkers, yet collectively serve as a foundational guide for further development of sweat-based diagnostics and for those beginning exploration of new biomarker opportunities in sweat.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The relatively stable behaviour of [K+] is explained by its passive ion partitioning mechanism13.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [13]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The decreases in concentration of lactate and glucose in sweat are expected, owing to the dilution effect caused by an increase in sweat rate, which is visually observed as exercise continues13.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [13]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The accurate measurement of physiologically relevant sweat glucose concentrations with epidermal biosensors faces several major challenges related to uncontrolled operational conditions (e.g., varying temperature and pH), glucose contamination from various sources, irregular sampling rates, and low sampling volumes.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [64]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Detection of biomarkers from eccrine sweat glands pose tremendous advantages over those from urine, blood, tears, and apocrine sweat glands. These, include their abundance on the body (>100 glands/cm2), ease of access, sampling and detection efficiency without foreign contamination during testing, and the inability to degrade analytes19 (Table 3).”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [19]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The color change in the detection reservoir correlated with the concentration of lactate throughout the relevant range expected in sweat (1.5 to 100 mM) (Fig. 3C) (13, 46, 47).”
From A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat (2016) · cites this paper as [13]
Experimental — accuracy not yet measured
14 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrowetting: from basics to applications
Mugele, F., & Baret, J.-C. (2005) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/17/28/r01 · Cited by 2,092
Clinical Methods: The History, Physical, and Laboratory Examinations
Kruse, J. A. (1990) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1990.03450210108045 · Cited by 2,029
Handbook of Experimental Pharmacology.
Meakin, J. W. (1971) · Archives of Internal Medicine · doi:10.1001/archinte.1971.00310230151026 · Cited by 1,959
Salivary cortisol as a biomarker in stress research
Hellhammer, D. H., Wüst, S., & Kudielka, B. M. (2009) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2008.10.026 · Cited by 1,925
Salivary Cortisol in Psychobiological Research: An Overview
Kirschbaum, C., & Hellhammer, D. H. (2008) · Neuropsychobiology · doi:10.1159/000118611 · Cited by 1,532
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Diagnostic Potential of Saliva: Current State and Future Applications
Pfaffe, T., Cooper-White, J., Beyerlein, P., Kostner, K., & Punyadeera, C. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.153767 · Cited by 798
Biology of sweat glands and their disorders. I. Normal sweat gland function
Sato, K., Kang, W. H., Saga, K., & Sato, K. T. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70063-3 · Cited by 717
Research works printed but not linked: 10
- 1977, Reviews of Physiology, Biochemistry and Pharmacology, 51
- C. Tronstad , “ Developments in biomedical sensors based on electrical impedance,” Doctor Philosophiae thesis ( University of Oslo, 2012).
- T. A. Peyser , R. O.Potts, H. L.Berman, J. W.Moyer, and M. A.Kouchnir, “ Devices, methods, and kits for non-invasive glucose measurement,” U.S. patent 7,725,149 (2010).
- 1993, The mechanism of eccrine sweat secretion, Perspect. Exercise Sci. Sports Med., 6, 85
- 2008, Theoretical Microfluidics, 346
- 2011, Medical Physiology: A Cellular and Molecular Approach
- 1999, Fitzpatrick's Dermatology in General Medicine
- 2000, Salivary cortisol, Encycl. Stress, 3, 379
- 2011, Peptides and proteins in pharmaceuticals, Int. J. Curr. Pharm. Res., 3, 1
- See supplementary material at http://dx.doi.org/10.1063/1.4921039E-BIOMGB-9-002503 for the derivation of the solute transport equation and sampling rate limitations for biosensors. · doi:10.1063/1.4921039e-biomgb-9-002503
Cited by
Items 501–600 of 782
Zhao, H., Zhang, X., Khan, W. U., Karbarz, M., & Zhang, Q. M. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202502468 · Cited by 10
Wei, L., Lv, Z., He, Y., Guo, D., Cheng, L., Wu, H., & Liu, A. (2022) · Biosensors · doi:10.3390/bios13010067 · Cited by 10
Molecular biomarkers for assessing the heat-adapted phenotype: a narrative scoping review
Corbett, J., Young, J. S., Tipton, M., Costello, J. T., Williams, T. B., Walker, E. F., Lee, B., & Stevens, C. E. (2023) · The Journal of Physiological Sciences · doi:10.1186/s12576-023-00882-4 · Cited by 10
Shiwaku, R., Matsui, H., Nagamine, K., & Tokito, S. (2023) · Advanced Sensor Research · doi:10.1002/adsr.202300106 · Cited by 10
Noninvasive Biomarkers for Disease Diagnosis and Health Monitoring
Pandey, R., Ngaju, P., Janghorban, M., Abuelazm, H., Malaeb, K., & Aryal, K. P. (2024) · Springer eBooks · doi:10.1007/978-981-97-5473-1_2 · Cited by 10
Jeerapan, I. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.85459 · Cited by 10
The Optimization of Analog Front-End for Fully Integrated Wearable Sweat Sensor
Kim, I.-H., Jin, H., Jiang, Y., & Qin, Y. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857939 · Cited by 10
Orlowska, M. K., Guan, B., Sedev, R. V., Morikawa, Y., Suu, K., & Priest, C. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03667 · Cited by 10
Wearable Electronic Tongue for Non-Invasive Assessment of Human Sweat
Falk, M., Nilsson, E. J., Cirovic, S., Tudosoiu, B., & Shleev, S. (2021) · Sensors · doi:10.3390/s21217311 · Cited by 10
A Wearable Patch for Prolonged Sweat Lactate Harvesting and Sensing
Saha, T., Fang, J., Yokus, M. A., Mukherjee, S., Bozkurt, A. Y., Daniele, M. A.-A., Dickey, M. D., & Velev, O. D. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630881 · Cited by 10
An integrated leather-based fluid transport wearable sweat device for electrolyte balance monitoring
Zhou, T., Shi, H., Ji, W., Liu, Y., Zhang, R., Liu, H., Wang, F., Zhu, J., Tao, C., Zha, B., et al. (2024) · Journal of Materials Chemistry C · doi:10.1039/d4tc01914h · Cited by 9
Guan, S., Wang, J., Yang, Y., Zhu, X., Zhou, J., Ye, D., Chen, R., Fan, Q., & Liao, Q. (2025) · Advanced Science · doi:10.1002/advs.202516229 · Cited by 9
Wearable Self‐Powered Biosensor for Continuous Lactate Monitoring in Sweat
Shitanda, I., Samori, T., Satake, M., Loew, N., Motosuke, M., Mukaimoto, T., Yanagita, S., Suzuki, T., Mikawa, T., Tsujimura, S., et al. (2025) · ChemElectroChem · doi:10.1002/celc.202500222 · Cited by 9
Zhu, D., Jiang, X., Sun, J., Zhang, J., Zhou, W., & Fu, S. (2025) · Advanced Fiber Materials · doi:10.1007/s42765-025-00629-3 · Cited by 9
Cai, J., Ma, C.-B., Bai, J., Bo, X., & Zhou, M. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.118474 · Cited by 9
Making Sweat Measurable: Induction, Sampling, and Refreshment in Wearable Biofluid Sensing
Shin, S., & Gao, W. F. (2026) · Advanced Science · doi:10.1002/advs.75684 · Cited by 9
Precise and efficient release of pilocarpine for sweat wearables
Chen, J., Lou, Y., Sun, L., Nilghaz, A., Liu, S., & Tian, J. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136403 · Cited by 9
Chen, C., Liu, Z., Li, J., Vurro, D., Jiang, Y., Xue, L., Gong, Y., & Qin, Y. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3465048 · Cited by 9
Liquid Bridge Cutting Valves for Microfluidic Passive Distribution and Sequential Reaction
Lin, R., Guo, W. F., Chen, Y., Li, H., Luo, Z., Fan, Z., Tu, J., Peng, L., & Liu, R. (2025) · Small · doi:10.1002/smll.202411708 · Cited by 9
Nanoparticle-based biomedical sensors
Tricoli, A., & Bo, R. (2020) · Frontiers of nanoscience · doi:10.1016/b978-0-08-102515-4.00009-x · Cited by 9
Hladek, M. D., Gill, J., Lai, C., Bandeen‐Roche, K., Xue, Q., Allen, J. K., Leyden, C., Kanefsky, R. Z., & Szanton, S. L. (2021) · Journal of Applied Gerontology · doi:10.1177/07334648211006518 · Cited by 9
Recent research progress in biomimetic tactile sensors
Zhang, J., Ma, Z., Li, S., Pan, L., & Shi, Y. (2019) · Scientia Sinica Technologica · doi:10.1360/sst-2019-0204 · Cited by 9
Jeerapan, I., Moonla, C., Thavarungkul, P., & Kanatharana, P. (2022) · Progress in molecular biology and translational science · doi:10.1016/bs.pmbts.2021.07.025 · Cited by 9
Wearable biosensors: an aid for cattle well-being
Sharma, R. (2025) · Sensor Review · doi:10.1108/sr-11-2024-0933 · Cited by 8
Breathable soft bioelectronics for enhanced automatic detection of obstructive sleep apnea
Ban, S., Kwon, Y., Shin, I., Perez, M. M., Smith, B. J., Huang, Y., Yoo, J. Y., Bae, J., Purnell, C. A., & Yeo, W. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117735 · Cited by 8
Advancing 3D printed microfluidics with computational methods for sweat analysis
Ece, E., Ölmez, K., Hacıosmanoğlu, N., Atabay, M., & İnci, F. (2024) · Microchimica Acta · doi:10.1007/s00604-024-06231-5 · Cited by 8
Wang, C., Zhang, Y., Zeng, X., Jin, C., Liu, Y., Yang, M. J., Huo, D., & Hou, C. (2025) · Analytica Chimica Acta · doi:10.1016/j.aca.2025.343971 · Cited by 8
Pan, W., Xu, S., Mao, X., Li, T., Cao, Q., Ye, X., & Liang, B. (2021) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems51815.2021.9451353 · Cited by 8
A Wearable Biosensor for Sweat Lactate as a Proxy for Sport Performance Monitoring
Xuan, X., Chen, C., Pérez‐Ràfols, C., Swarén, M., Wedholm, L., Cuartero, M., & Crespo, G. A. (2022) · Analysis & Sensing · doi:10.1002/anse.202200047 · Cited by 8
Moorthy, V. M., & Srivastava, V. M. (2023) · Recent Patents on Nanotechnology · doi:10.2174/1872210517666230414081056 · Cited by 8
Tabata, M., & Miyahara, Y. (2024) · Proceedings of the Japan Academy Series B · doi:10.2183/pjab.100.004 · Cited by 8
Vending-Machine-Style Skin Excretion Sensing
Yu, K.-C., Hsu, C.-Y., Prabhu, G. R. D., Chiu, H., & Urban, P. L. (2023) · ACS Sensors · doi:10.1021/acssensors.2c02325 · Cited by 8
Monitoring Skin Volatile Emissions Using Wearable Sensors
Angioi, R., Thamatam, N., Agah, M., & Morrin, A. (2025) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071024-020707 · Cited by 7
Sung, D., Jekal, B., Lee, S. I., Kang, T., Jeong, K., Lee, S.-H., Kwak, K., Koo, J., & Kim, S. (2026) · npj Flexible Electronics · doi:10.1038/s41528-026-00549-1 · Cited by 7
Sivasubramanian, A., Narayanan, S., & Slaughter, G. E. (2026) · Biosensors · doi:10.3390/bios16050287 · Cited by 7
Jaiswal, A. K., Jose, C. T., Ramesh, R., Nanani, V. K., Sadeghi, K., Joshi, A., Kompally, K., Pathikonda, G., Emady, H. N., Bheda, B., et al. (2024) · iScience · doi:10.1016/j.isci.2024.110304 · Cited by 8
Gao, Y., Liu, Y., Zhang, Y., Li, Y., & Zhang, L. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.111147 · Cited by 7
Zhi, D., Li, C., Ye, D., Jiang, Z., Zhang, B., Yan, C., Zhao, H., Han, Z., Xiang, L., Li, J., et al. (2024) · Wearable electronics. · doi:10.1016/j.wees.2024.09.002 · Cited by 7
Yang, M., Cheng, J., Zhao, X., Cai, J., & Zhou, W. (2024) · Analytical Sciences · doi:10.1007/s44211-024-00705-5 · Cited by 7
Chen, J., Lou, Y., Sun, L., Chia, C. H., Nilghaz, A., & Tian, J. (2025) · ACS Sensors · doi:10.1021/acssensors.4c03277 · Cited by 7
Nanofibrous Membrane-Based Stretchable Electrochemical Sweat Sensor for pH Detection
Zhang, L., Ma, B., Xu, Z., & Zhao, Y. J. (2025) · Polymers · doi:10.3390/polym17050663 · Cited by 7
Patil, N. J., Vishnuraj, R., Mani, G. K., Rangarajan, M., & Srinivasan, P. (2025) · Electrochimica Acta · doi:10.1016/j.electacta.2025.146716 · Cited by 7
Making commercial bracelet smarter with a biochemical button module
Chen, J., Tao, X., Xu, X., Sun, L., Huang, R., Nilghaz, A., & Tian, J. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116163 · Cited by 7
The Heavy Metals in Human Body Fluids Related to the Tobacco Smoke: A Systematic Review
Momen, A., & Rostami, R. (2023) · Tobacco and Health · doi:10.34172/thj.2023.1064 · Cited by 7
Zhang, W., Zhu, X., Kang, M., Xu, J., Zuo, Y., Sun, M., Zhao, C., & Liu, H. (2022) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2022.116254 · Cited by 7
Real-time Skin Lactic Acid Monitoring System for Assessment of Training Intensity
Enomoto, K., Shimizu, R., & Kudo, H. (2017) · IEEJ Transactions on Sensors and Micromachines · doi:10.1541/ieejsmas.137.450 · Cited by 7
Nafion®-coated mesoporous Pd film toward remarkably enhanced detection of lactic acid
Baba, D., Nugraha, A. S., Iqbal, M., Jiang, B., Li, C., Alshehri, A. A., You, J., Malgras, V., Yamachi, Y., & Asahi, T. (2018) · RSC Advances · doi:10.1039/c7ra13026k · Cited by 7
Sports medicine: bespoke player management
Stuart, S., Powell, D., Marshall, S. J., Clark, C. C. T., Martini, D. N., Johnston, W., & Godfrey, A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-818914-6.00021-1 · Cited by 7
Purely electrical detection of electrolyte concentration through microfluidic impedance spectroscopy
Wade, T., Malik, S., Ives, L., Ćatić, N., & Kar‐Narayan, S. (2024) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2024.102133 · Cited by 6
Deshpande, P., De, D., Badhe, Y. P., Tallur, S. G., Paul, D., & Rai, B. (2024) · Scientific Reports · doi:10.1038/s41598-024-73044-0 · Cited by 6
Internet of harvester nano things: A future prospects
Maitra, B., Bardakçı, E., Cetinkaya, O., & Akan, Ö. B. (2024) · Nano Communication Networks · doi:10.1016/j.nancom.2024.100550 · Cited by 6
Nichols, A. L., Marotta, C. B., Lukas, H., Friesenhahn, N. J., Wagenaar, D. A., Mayo, S. L., Dougherty, D. A., Benowitz, N. L., Gao, W. F., Muthusamy, A. K., et al. (2025) · Nicotine & Tobacco Research · doi:10.1093/ntr/ntaf062 · Cited by 6
Spano, J. M., Demchak, L. L., Nakano, K., Conti, T., Heikenfeld, J. C., & Milla, C. E. (2025) · Scientific Reports · doi:10.1038/s41598-025-05051-8 · Cited by 6
Self-citationA micro-to-macroscale and multi-method investigation of human sweating dynamics
Jose, C. T., Joshi, A., Viswanathan, S. H., Nash, S. K., Sadeghi, K., Kavouras, S. A., & Rykaczewski, K. (2025) · Journal of The Royal Society Interface · doi:10.1098/rsif.2025.0407 · Cited by 6
Yin, X., Adelaars, S., Peri, E., Pelssers, E., den Toonder, J. M. J., Bouwman, R. A., van de Kerkhof, D., & Mischi, M. (2025) · Sensors · doi:10.3390/s25154551 · Cited by 6
Lin, X., Wang, Y., Geng, Y., He, Y., Meng, S., Lin, X., & Wu, L. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.115615 · Cited by 6
Hosseinzadeh, B., Tonello, S., Lopomo, N. F., & Sardini, E. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3646709 · Cited by 6
Real-time on-body sweat sensing: Electrochemical insights, progress, and prospects
Saikrithika, S., Zahra, L., Theyagarajan, K., & Kim, Y.-J. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.118882 · Cited by 6
Biosensors Technologies for Point-of-Care Testing – A Review
Baluta, S., Cabaj, J., & Malecha, K. (2020) · Periodica Polytechnica Electrical Engineering and Computer Science · doi:10.3311/ppee.15358 · Cited by 6
Development of an insilico model of eccrine sweat using molecular modelling techniques
Deshpande, P., Ravikumar, B., Tallur, S. G., Paul, D., & Rai, B. (2022) · Scientific Reports · doi:10.1038/s41598-022-24440-x · Cited by 6
Wang, B., Wilhelm, A., Wilhelm, A., Pilehvar, S., Moshfeghi, S., Stout, P., Salahi, K., & Emaminejad, S. (2020) · Elsevier eBooks · doi:10.1016/b978-0-08-102407-2.00003-5 · Cited by 6
Evaporation-Induced Clogging of an Artificial Sweat Duct
Lolla, V. Y., Shukla, P., Jones, S. D., & Boreyko, J. B. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c13493 · Cited by 6
Mathiaparanam, S., de Macedo, A. N., Gill, B., Keenan, K., Gonska, T. Y., Pedder, L., Hill, S., & Britz‐McKibbin, P. (2022) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2022.05.004 · Cited by 6
The modeling of the interaction of pulsed 5G/6G signals and the fine structure of human skin
Betzalel, N., Feldman, Y. D., & Ishai, P. B. (2025) · Scientific Reports · doi:10.1038/s41598-025-13777-8 · Cited by 5
Wearable microfluidic devices for multiplex body fluid monitoring
Sun, Y., Guo, X., Jiang, Y., Cui, J., Wu, J., Wang, J., Cheng, W. M., Shi, Y., & Pan, L. (2025) · The Analyst · doi:10.1039/d5an00739a · Cited by 5
Duan, L., Chen, Q., Huang, S., Yu, Z., Zhao, X., Chen, C., Li, S., Fan, H., Fan, B., & Chen, Z. (2025) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2025.138947 · Cited by 5
HEMT-Based Wearable Biosensors for Noninvasive Health Monitoring and AI-Driven Diagnostics: A Review
Das, C., & Mazumdar, K. (2025) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2025.3639676 · Cited by 5
Non-enzymatic sweat-based glucose sensors: progress, difficulties, and prospects
Perumal, K., Sreeja, B. S., & Sulthana, S. F. (2026) · Sensors & Diagnostics · doi:10.1039/d6sd00042h · Cited by 5
Uruc, S., Dokur, E., Kurteli, R., Gorduk, O., & Şahin, Y. (2023) · New Journal of Chemistry · doi:10.1039/d3nj01525d · Cited by 5
Elementary integrate-and-fire process underlies pulse amplitudes in Electrodermal activity
Subramanian, S., Purdon, P. L., Barbieri, R., & Brown, E. N. (2021) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1009099 · Cited by 5
Wallace, S. G., Brothers, M. C., Brooks, Z., Rangnekar, S. V., Lam, D. K., Lawrence, M. S., Rojas, W. A. G., Putz, K. W., Kim, S. S., & Hersam, M. C. (2022) · Engineering Research Express · doi:10.1088/2631-8695/ac5e27 · Cited by 5
Recent progress in wearable extractive sampling technology
Kahremanoğlu, K., Kurtalan, H. T., Eroğlu, A. E., & Boyacı, E. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116740 · Cited by 5
Gotsmy, M., Brunmair, J., Bueschl, C., Gerner, C., & Zanghellini, J. (2022) · BMC Bioinformatics · doi:10.1186/s12859-022-04918-1 · Cited by 5
A yarn/fabric-based microfluidic patch for sweat sensing and monitoring
Wenze, Y., Li, Q., Zhao, Z., Gong, J., Li, Z., & Zhang, J. (2023) · Journal of the Textile Institute · doi:10.1080/00405000.2023.2288357 · Cited by 5
Welzel, J., Gruedl, S., Welss, T., Claas, M., Sättler, A., Förster, T., & Banowski, B. (2021) · International Journal of Cosmetic Science · doi:10.1111/ics.12679 · Cited by 5
Recent Advances in Glucose Fuel Cells for Biomedical Applications
Yin, M., Xu, L., Liu, S., & Li, Z. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202501379 · Cited by 4
MIP-based wearable sweat sensors: From materials design to integrated systems
Wang, Z., Chen, X., Dong, W., & Wang, Z. (2026) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2026.101227 · Cited by 4
Chen, Y., Liu, X., Xia, J., Guo, S., Zhao, X., You, C., Song, S., Yu, Z., Che, C., Huang, X., et al. (2026) · Advanced Functional Materials · doi:10.1002/adfm.202531819 · Cited by 4
Advances in Wearable Biosensors for Non-Invasive Biofluid Monitoring
Mondal, R., & Saikia, M. J. (2026) · Biosensors · doi:10.3390/bios16060336 · Cited by 4
Khan, M. R. R., Park, J., Hwang, T., Seo, J., & Lee, H. S. (2025) · BioChip Journal · doi:10.1007/s13206-025-00204-3 · Cited by 4
Quantitative analysis for sweat-absorbing times of paper-based microfluidic chips
Huang, H., Xu, C., Long, P., Chen, Y., Huang, X., Liu, Z., & Yang, H. (2023) · Microfluidics and Nanofluidics · doi:10.1007/s10404-023-02696-7 · Cited by 4
Heikenfeld, J. C. (2024) · Frontiers in Sensors · doi:10.3389/fsens.2024.1408158 · Cited by 4
Self-citationSingh, C., Hempel, F., Endres, K., Engelmann, J., & Tarasov, A. (2025) · 2D Materials · doi:10.1088/2053-1583/adce17 · Cited by 4
Shay, T. (2017) · NCSU Libraries Repository (North Carolina State University Libraries) · Cited by 4
Stephenson, T., Ellero, C. C., Sebastia‐Saez, D., Victorovich, K. O., Battley, A. M., & Arellano‐García, H. (2020) · International Journal of Clothing Science and Technology · doi:10.1108/ijcst-07-2019-0100 · Cited by 4
Wearable sweat sensing device determining sweat rate per gland
Kani, S. M., Marteijn, R. J. H., Pelssers, E., & den Toonder, J. M. J. (2023) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea57477.2023.10171867 · Cited by 4
Current Trends in the Development of Electrochemical Biosensor for Detecting Analytes from Sweat
Singh, A., Sharma, A., Dubey, A., & Arya, S. K. (2023) · Current Medicinal Chemistry · doi:10.2174/0929867331666230807143639 · Cited by 4
Harris, J., Bickford, J. R., Cho, P. S., Coppock, M. B., Farrell, M. E., Holthoff, E. L., & Ratcliff, E. L. (2019) · Chemical, Biological, Radiological, Nuclear, and Explosives (CBRNE) Sensing · doi:10.1117/12.2518543 · Cited by 4
Advances in Minimally Invasive Surgery
Sanna, A. (2021) · IntechOpen eBooks · doi:10.5772/intechopen.92508 · Cited by 4
Human Subjects Testing of Sweat Stimulation Technologies
Wilder, E. (2016) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 4
Self-citationLCMS Measurement of Steroid Biomarkers Collected from Palmar Sweat.Preprint
Hyde, J., & Runyon, J. R. (2020) · ChemRxiv · doi:10.26434/chemrxiv.12931769 · Cited by 4
Yin, X., Peri, E., Pelssers, E., den Toonder, J. M. J., & Mischi, M. (2025) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-025-03393-z · Cited by 3
A flexible enzymatic sensor for lactate detection in sweat
Wang, M., Lou, H., Zheng, H., & Jiang, L. (2025) · Pure and Applied Chemistry · doi:10.1515/pac-2025-0551 · Cited by 3
A low-interference and highly comfortable wearable sensor for dynamic sweat monitoring
Xiang, Z., Zeng, C., Wu, Y., Yu, Y., Tang, M., Wei, K., Shang, J., Wang, H., Liu, Y., & Li, R.-W. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.115456 · Cited by 3
Mo, Q., Huang, Z., Luo, Z., Lin, F., Li, B., Xu, H., Sun, Y., Song, J., Weng, X., Liu, L., et al. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.139446 · Cited by 3
Recent advances in wearable sensor technology for sweat analysis
Jacob, J., Niranjan, D. B., Sharma, A., Jayakrishnan, S., Jose, R. C., Medikonda, J., Peter, M., & Namboothiri, P. K. (2026) · Discover Applied Sciences · doi:10.1007/s42452-026-08404-8 · Cited by 3
From lab to field: progress and prospect of sweat sensing technology in sports monitoring
Gao, N., Deng, X., Lei, Y., Jiang, P., & Wu, Y. (2026) · Microchimica Acta · doi:10.1007/s00604-026-07835-9 · Cited by 3
Zhang, Y., Zhong, B., Yuan, Y., Xu, K., Yu, Y., Lou, Z., & Wang, L. (2026) · Advanced Materials Technologies · doi:10.1002/admt.202502662 · Cited by 3
Bavafa, P., Sorkhe, Y. A., Stanciu, L., & Uzunoğlu, A. (2026) · Sensors & Diagnostics · doi:10.1039/d5sd00221d · Cited by 3
Wearable biofluids colorimetric biosensors
Lyu, Z., Xiao, Z., Shen, W., Liu, C., Gu, T., Cao, R., Zhang, F., Meng, C., & Ding, S. (2026) · FlexMat. · doi:10.1002/flm2.70081 · Cited by 3
Metadata
- Authors
- Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., & Naik, R.
- Affiliations
- University of Cincinnati (US)
- Procter & Gamble (United States) (US)
- United States Air Force Research Laboratory (US)
- Air Force Research Laboratory 5 711 Human Performance Wing, Human Effectiveness Directorate, , Wright-Patterson Air Force Base, Dayton, Ohio 45233, USA
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2015-05-01
- Volume
- 9
- Issue
- 3
- Pages
- 031301-031301
- ISSN
- 1932-1058 (ISSN-L)
- PMC
- PMC4433483
- OpenAlex
- W1548680965
- Cited by
- 724
- References
- 86
- Citations by year
- 2026: 57 · 2025: 80 · 2024: 96 · 2023: 84 · 2022: 76 · 2021: 79 · 2020: 84 · 2019: 60 · 2018: 55 · 2017: 30 · 2016: 20 · 2015: 2
- FWCI
- 17.72
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/3.0/ (vor, 14 d)
- creativecommons.org/licenses/by/3.0/ (tdm, 14 d)
- Locations
- Biomicrofluidics (publishedVersion, cc-by)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Center for Advanced Design and Manufacturing of Integrated Microfluidics (IIP-1362165)
- Air Force Office of Scientific Research (Summer Faculty Fellowship Program)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Keywords
- eccrine sweat glands, sweat biomarkers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.