Anomalous resonance in a nanomechanical biosensor
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
The decrease in resonant frequency (−Δω r ) of a classical cantilever provides a sensitive measure of the mass of entities attached on its surface. This elementary phenomenon has been the basis of a new class of bio-nanomechanical devices as sensing components of integrated microsystems that can perform rapid, sensitive, and selective detection of biological and biochemical entities. Based on classical analysis, there is a widespread perception that smaller sensors are more sensitive (sensitivity ≈ −0.5ω r / m C , where m C is the mass of the cantilever), and this notion has motivated scaling of biosensors to nanoscale dimensions. In this work, we show that the response of a nanomechanical biosensor is far more complex than previously anticipated. Indeed, in contrast to classical microscale sensors, the resonant frequencies of the nanosensor may actually decrease or increase after attachment of protein molecules. We demonstrate theoretically and experimentally that the direction of the frequency change arises from a size-specific modification of diffusion and attachment kinetics of biomolecules on the cantilevers. This work may have broad impact on microscale and nanoscale biosensor design, especially when predicting the characteristics of bio-nanoelectromechanical sensors functionalized with biological capture molecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peters, T. (1985) · Advances in Protein Chemistry · doi:10.1016/s0065-3233(08)60065-0 · Cited by 2,181
Calibration of rectangular atomic force microscope cantilevers
Sader, J. E., Chon, J. W. M., & Mulvaney, P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150021 · Cited by 2,145
Electrical detection of single viruses
Patolsky, F., Zheng, G., Hayden, O., Lakadamyali, M., Zhuang, X., & Lieber, C. M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406159101 · Cited by 1,258
Zeptogram-Scale Nanomechanical Mass Sensing
Yang, Y. T., Callegari, C., Feng, X. L., Ekinci, K. L., & Roukes, M. L. (2006) · Nano Letters · doi:10.1021/nl052134m · Cited by 1,041
Ultrasensitive nanoelectromechanical mass detection
Ekinci, K. L., Huang, X. M. H., & Roukes, M. L. (2004) · Applied Physics Letters · doi:10.1063/1.1755417 · Cited by 702
Hendrickson, W. A., Pähler, A., Smith, J. L., Satow, Y., Merritt, E. A., & Phizackerley, R. P. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.7.2190 · Cited by 588
Attogram detection using nanoelectromechanical oscillators
Ilic, B., Craighead, H. G., Krylov, S., Senaratne, W., Ober, C., & Neuzil, P. (2004) · Journal of Applied Physics · doi:10.1063/1.1650542 · Cited by 585
Single virus particle mass detection using microresonators with nanoscale thickness
Gupta, A., Akin, D., & Bashir, R. (2004) · Applied Physics Letters · doi:10.1063/1.1667011 · Cited by 543
Self-citationAdsorption-induced surface stress and its effects on resonance frequency of microcantilevers
Chen, G. Y., Thundat, T., Wachter, E. A., & Warmack, R. J. (1995) · Journal of Applied Physics · doi:10.1063/1.359562 · Cited by 539
Short cantilevers for atomic force microscopy
Walters, D. A., Cleveland, J. P., Thomson, N. H., Hansma, P. K., Wendman, M. A., Gurley, G., & Elings, V. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147177 · Cited by 494
Single cell detection with micromechanical oscillators
Ilic, B., Czaplewski, D., Zalalutdinov, M., Craighead, H. G., Neuzil, P., Campagnolo, C., & Batt, C. (2001) · Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena · doi:10.1116/1.1421572 · Cited by 443
Virus detection using nanoelectromechanical devices
Ilic, B., Yang, Y., & Craighead, H. G. (2004) · Applied Physics Letters · doi:10.1063/1.1794378 · Cited by 365
Performance limits of nanobiosensors
Nair, P. R., & Alam, M. A. (2006) · Applied Physics Letters · doi:10.1063/1.2211310 · Cited by 341
Self-citationPuzzles and paradoxes in protein adsorption
Ramsden, J. J. (1995) · Chemical Society Reviews · doi:10.1039/cs9952400073 · Cited by 180
Cryo Atomic Force Microscopy: A New Approach for Biological Imaging at High Resolution
Han, W., Mou, J., Sheng, J., Yang, J., & Shao, Z. (1995) · Biochemistry · doi:10.1021/bi00026a001 · Cited by 110
Ptak, A., Takeda, S., Nakamura, C., Miyake, J., Kageshima, M., Jarvis, S., & Tokumoto, H. (2001) · Journal of Applied Physics · doi:10.1063/1.1397287 · Cited by 31
Cited by
Comparative advantages of mechanical biosensors
Arlett, J. L., Myers, E. B., & Roukes, M. L. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.44 · Cited by 966
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Micro- and nanomechanical sensors for environmental, chemical, and biological detection
Waggoner, P. S., & Craighead, H. G. (2007) · Lab on a Chip · doi:10.1039/b707401h · Cited by 678
Label-free biomarker detection from whole blood
Stern, E., Vacic, A., Rajan, N. K., Criscione, J. M., Park, J., Ilic, B. R., Mooney, D. J., Reed, M. A., & Fahmy, T. M. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2009.353 · Cited by 543
Eom, K., Park, H. S., Yoon, D. S., & Kwon, T. (2011) · Physics Reports · doi:10.1016/j.physrep.2011.03.002 · Cited by 464
Metadata
- Authors
- Gupta, A. K., Nair, P. R., Akin, D., Ladisch, M. R., Broyles, S., Alam, M. A., & Bashir, R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2006-09-05
- Volume
- 103
- Issue
- 36
- Pages
- 13362-13367
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2029362828
- Cited by
- 160
- References
- 16
- FWCI
- 13.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.