Nonlinear structured-illumination microscopy with a photoswitchable protein reveals cellular structures at 50-nm resolution
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Using ultralow light intensities that are well suited for investigating biological samples, we demonstrate whole-cell superresolution imaging by nonlinear structured-illumination microscopy. Structured-illumination microscopy can increase the spatial resolution of a wide-field light microscope by a factor of two, with greater resolution extension possible if the emission rate of the sample responds nonlinearly to the illumination intensity. Saturating the fluorophore excited state is one such nonlinear response, and a realization of this idea, saturated structured-illumination microscopy, has achieved approximately 50-nm resolution on dye-filled polystyrene beads. Unfortunately, because saturation requires extremely high light intensities that are likely to accelerate photobleaching and damage even fixed tissue, this implementation is of limited use for studying biological samples. Here, reversible photoswitching of a fluorescent protein provides the required nonlinearity at light intensities six orders of magnitude lower than those needed for saturation. We experimentally demonstrate approximately 40-nm resolution on purified microtubules labeled with the fluorescent photoswitchable protein Dronpa, and we visualize cellular structures by imaging the mammalian nuclear pore and actin cytoskeleton. As a result, nonlinear structured-illumination microscopy is now a biologically compatible superresolution imaging method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Self-citationSub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Gustafsson, M. G. L. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00710.x · Cited by 3,786 · cited 4×
“By choosing an appropriately small pinhole in confocal microscopy (12), or an appropriately fine line spacing in linear SIM (13), structures at roughly p 2 or 2 times the conventional diffraction limit can be resolved, respectively.”
BackgroundMethodInfluentialSelf-citationUltra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Crystal Structure of the Aequorea victoria Green Fluorescent Protein
Ormö, M., Cubitt, A. B., Kallio, K., Gross, L. A., Tsien, R. Y., & Remington, S. J. (1996) · Science · doi:10.1126/science.273.5280.1392 · Cited by 2,242
Gustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224
Self-citationLifeact: a versatile marker to visualize F-actin
Riedl, J., Crevenna, A. H., Kessenbrock, K., Yu, J. H., Neukirchen, D., Bista, M., Bradke, F., Jenne, D., Holak, T. A., Werb, Z., et al. (2008) · Nature Methods · doi:10.1038/nmeth.1220 · Cited by 2,189
Subdiffraction‐Resolution Fluorescence Imaging with Conventional Fluorescent Probes
Heilemann, M., van de Linde, S., Schüttpelz, M., Kasper, R., Seefeldt, B., Mukherjee, A., Tinnefeld, P., & Sauer, M. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200802376 · Cited by 1,866
Gustafsson, M. G. L., Shao, L., Carlton, P. M., Wang, C. J. R., Golubovskaya, I. N., Cande, W. Z., Agard, D. A., & Sedat, J. W. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.120345 · Cited by 1,557
Self-citation
Cited by
Chen, F., Tillberg, P. W., & Boyden, E. S. (2015) · Science · doi:10.1126/science.1260088 · Cited by 1,501
Super-resolution microscopy demystified
Schermelleh, L., Ferrand, A., Huser, T., Eggeling, C., Sauer, M., Biehlmaier, O., & Drummen, G. P. C. (2019) · Nature Cell Biology · doi:10.1038/s41556-018-0251-8 · Cited by 1,211
Extended-resolution structured illumination imaging of endocytic and cytoskeletal dynamics
Li, D., Shao, L., Chen, B.-C., Zhang, X., Zhang, M., Moses, B., Milkie, D. E., Beach, J. R., Hammer, J. A., Pasham, M., et al. (2015) · Science · doi:10.1126/science.aab3500 · Cited by 748
Self-citationVisualizing and discovering cellular structures with super-resolution microscopy
Sigal, Y. M., Zhou, R., & Zhuang, X. (2018) · Science · doi:10.1126/science.aau1044 · Cited by 718
Tillberg, P. W., Chen, F., Piatkevich, K. D., Zhao, Y., Yu, C.-C., English, B. P., Gao, L., Martorell, A., Suk, H.-J., Yoshida, F., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3625 · Cited by 664
Super-Resolution Structured Illumination Microscopy
Heintzmann, R., & Huser, T. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00218 · Cited by 574
Bultreys, T., De Boever, W., & Cnudde, V. (2016) · Earth-Science Reviews · doi:10.1016/j.earscirev.2016.02.001 · Cited by 474
Instant super-resolution imaging in live cells and embryos via analog image processing
York, A. G., Chandris, P., Nogare, D. D., Head, J., Wawrzusin, P., Fischer, R. S., Chitnis, A., & Shroff, H. (2013) · Nature Methods · doi:10.1038/nmeth.2687 · Cited by 404
Modulating biomolecular condensates: a novel approach to drug discovery
Mitrea, D. M., Mittasch, M., Gomes, B. F., Klein, I. A., & Murcko, M. A. (2022) · Nature Reviews Drug Discovery · doi:10.1038/s41573-022-00505-4 · Cited by 401
Beliveau, B. J., Boettiger, A. N., Avendaño, M. S., Jungmann, R., McCole, R. B., Joyce, E. F., Kim-Kiselak, C., Bantignies, F., Fonseka, C. Y., Erceg, J., et al. (2015) · Nature Communications · doi:10.1038/ncomms8147 · Cited by 384
“Structured illumination microscopy (SIM) 20,21 has been the most broadly used super-resolution method to date for imaging genomic loci in situ 22–27 .”
Faster, sharper, and deeper: structured illumination microscopy for biological imaging
Wu, Y., & Shroff, H. (2018) · Nature Methods · doi:10.1038/s41592-018-0211-z · Cited by 375
Müller, M., Mönkemöller, V., Hennig, S., Hübner, W., & Huser, T. (2016) · Nature Communications · doi:10.1038/ncomms10980 · Cited by 340
Fluorescent proteins for live-cell imaging with super-resolution
Nienhaus, K., & Ulrich Nienhaus, G. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60171d · Cited by 337
Strategic and practical guidelines for successful structured illumination microscopy
Demmerle, J., Innocent, C., North, A. J., Ball, G., Müller, M., Miron, E., Matsuda, A., Dobbie, I. M., Markaki, Y., & Schermelleh, L. (2017) · Nature Protocols · doi:10.1038/nprot.2017.019 · Cited by 336
The 2015 super-resolution microscopy roadmap
Hell, S. W., Sahl, S. J., Bates, M., Zhuang, X., Heintzmann, R., Booth, M. J., Bewersdorf, J., Shtengel, G., Hess, H., Tinnefeld, P., et al. (2015) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/48/44/443001 · Cited by 325
Switchable Fluorophores for Single-Molecule Localization Microscopy
Li, H., & Vaughan, J. C. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00767 · Cited by 319
Superresolution Multidimensional Imaging with Structured Illumination Microscopy
Jost, A., & Heintzmann, R. (2013) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-071312-121648 · Cited by 318
Single Cell Optical Imaging and Spectroscopy
Stender, A. S., Marchuk, K., Liu, C., Sander, S., Meyer, M. W., Smith, E. A., Neupane, B., Wang, G., Li, J., Cheng, J.-X., et al. (2013) · Chemical Reviews · doi:10.1021/cr300336e · Cited by 292
Nanoparticles for super-resolution microscopy and single-molecule tracking
Jin, D., Xi, P., Wang, B., Zhang, L., Enderlein, J., & van Oijen, A. M. (2018) · Nature Methods · doi:10.1038/s41592-018-0012-4 · Cited by 283
Nanoscopy with more than 100,000 'doughnuts'
Chmyrov, A., Keller, J., Grotjohann, T., Ratz, M., d'Este, E., Jakobs, S., Eggeling, C., & Hell, S. W. (2013) · Nature Methods · doi:10.1038/nmeth.2556 · Cited by 271
Superresolution structured illumination microscopy reconstruction algorithms: a review
Chen, X., Zhong, S., Hou, Y., Cao, R., Wang, W., Li, D., Dai, Q., Kim, D., & Xi, P. (2023) · Light: Science & Applications · doi:10.1038/s41377-023-01204-4 · Cited by 229
“Category 2: nonlinear SIM based on fluorescent photoswitchable proteins In 2012, Rego et al.68 discovered that the reversible photoswitching (Fig.”
BackgroundPhotocontrollable Fluorescent Proteins for Superresolution Imaging
Shcherbakova, D. M., Sengupta, P., Lippincott-Schwartz, J., & Verkhusha, V. V. (2014) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-051013-022836 · Cited by 228
“The nonlinear technique SIM has also been adapted for use with low light intensities and rsFPs as probes (60) Spatial resolution in RESOLFT and other patterned illumination techniques can be characterized by FWHM of the intensity profile, which corresponds to a cellular structure (Figure 3a).”
An introduction to optical super-resolution microscopy for the adventurous biologist
Vangindertael, J., Camacho, R., Sempels, W., Mizuno, H., Dedecker, P., & Janssen, K. P. F. (2018) · Methods and Applications in Fluorescence · doi:10.1088/2050-6120/aaae0c · Cited by 208
Widely accessible method for superresolution fluorescence imaging of living systems
Dedecker, P., Mo, G. C. H., Dertinger, T., & Zhang, J. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1204917109 · Cited by 204
“SSIM recently demonstrated a 40-nm resolution using the Dronpa photoswitching to induce fluorescence saturation (35), but requires a custom-built imaging system as well as the addition of a cytotoxic antifade reagent to counteract photodestruction of the label.”
MethodSingle-molecule techniques in biophysics: a review of the progress in methods and applications
Miller, H., Zhou, Z., Shepherd, J., Wollman, A. J. M., & Leake, M. C. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aa8a02 · Cited by 184
“Non-linear SIM can also be achieved using photoswitchable proteins to introduce the non-linearity [128].”
BackgroundAli, M. H., Elsherbiny, M. E., & Emara, M. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20102511 · Cited by 181
Genetically encoded biosensors for visualizing live-cell biochemical activity at super-resolution
Mo, G. C. H., Ross, B., Hertel, F., Manna, P., Yang, X., Greenwald, E., Booth, C., Plummer, A. M., Tenner, B., Chen, Z., et al. (2017) · Nature Methods · doi:10.1038/nmeth.4221 · Cited by 168
Nanoscopy of living brain slices with low light levels
Testa, I., Urban, N. T., Jakobs, S., Eggeling, C., Willig, K. I., & Hell, S. W. (2012) · Neuron · doi:10.1016/j.neuron.2012.07.028 · Cited by 131
Metadata
- Authors
- Rego, E. H., Shao, L., Macklin, J. J., Winoto, L., Johansson, G. A., Kamps-Hughes, N., Davidson, M. W., & Gustafsson, M. G. L.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-12-12
- Volume
- 109
- Issue
- 3
- Pages
- E135-43
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2001083377
- Cited by
- 399
- References
- 44
- FWCI
- 15.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.