Ultraflexible, large-area, physiological temperature sensors for multipoint measurements
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Significance: We have successfully fabricated very unique ultraflexible temperature sensors that exhibit changes in resistivity by six orders of magnitude or more for a change in temperature of only 5 °C or less. Our approach offers an ideal solution to measure temperature over a large area with high spatial resolution, high sensitivity of 0.1 °C or less, and fast response time of 100 ms. Indeed, such a large change of resistivity for our sensors can significantly simplify the readout circuitry, which was the key to demonstrate, to our knowledge, the world’s first successful measurement of dynamic change of temperature in the lung during very fast artificial respiration. Furthermore, we have demonstrated real-time multipoint thermal sensing using organic transistor active-matrix circuits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“For measuring spatial temperature gradients, an organic active matrix with polymer PTC sensor pads was fabricated on a PI substrate, which exhibits a bending insensitivity and high spatial resolution (Figure 7A and 7B).[103]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [103]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1948) · Journal of Applied Physiology · doi:10.1152/jappl.1948.1.2.93 · Cited by 4,646
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.1.5 · Cited by 3,982 · cited 1×
“Considering the density of capillary vessels, sweat glands, and the heat-transfer coefficient of moist tissue, sensors arrays with 2–3-mm pitch would be most suitable for recording thermal events (33).”
An ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485 · cited 2×
“The gate dielectric consists of an anodized aluminum oxide layer (9) and a phosphonic acid self-assembled monolayer (SAM) (25).”
Self-citationSchwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042 · cited 1×
“There have been reports of the potential application of flexible electrodes on ultrathin substrates (4), flexible sensors that measure biological signals, electrocardiograms, temperature, pressure (5, 6), organic amplifier systems (7), high-sensitivity pressure sensors (8), and ultrathin and imperceptible devices (9,…”
Ultralow-power organic complementary circuits
Klauk, H., Zschieschang, U., Pflaum, J., & Halik, M. (2007) · Nature · doi:10.1038/nature05533 · Cited by 1,398 · cited 2×
“The gate dielectric consists of an anodized aluminum oxide layer (9) and a phosphonic acid self-assembled monolayer (SAM) (25).”
Someya, T., Kato, Y., Sekitani, T., Iba, S., Noguchi, Y., Murase, Y., Kawaguchi, H., & Sakurai, T. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0502392102 · Cited by 1,389 · cited 1×
“Due to high oxygen sensitivity, a simple parylene layer does not exhibit sufficiently low gas permeability for the encapsulation of organic PN diodes (24).”
Self-citationUltrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. C., Bonifas, A. P., Behnaz, A., Zhang, Y., Yu, K. J., Cheng, H., Shi, M., Bian, Z., Liu, Z., Kim, Y.-S., et al. (2013) · Nature Materials · doi:10.1038/nmat3755 · Cited by 1,229
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136 · cited 1×
“There have been reports of the potential application of flexible electrodes on ultrathin substrates (4), flexible sensors that measure biological signals, electrocardiograms, temperature, pressure (5, 6), organic amplifier systems (7), high-sensitivity pressure sensors (8), and ultrathin and imperceptible devices (9,…”
In vivo recordings of brain activity using organic transistors
Khodagholy, D., Doublet, T., Quilichini, P., Gurfinkel, M., Leleux, P., Ghestem, A., Ismailova, E., Hervé, T., Sanaur, S., Bernard, C., et al. (2013) · Nature Communications · doi:10.1038/ncomms2573 · Cited by 1,012 · cited 1×
“There have been reports of the potential application of flexible electrodes on ultrathin substrates (4), flexible sensors that measure biological signals, electrocardiograms, temperature, pressure (5, 6), organic amplifier systems (7), high-sensitivity pressure sensors (8), and ultrathin and imperceptible devices (9,…”
Yamamoto, T., & Takimiya, K. (2007) · Journal of the American Chemical Society · doi:10.1021/ja068429z · Cited by 898 · cited 1×
“A 30-nm-thick dinaphtho[2,3-b:29,39-f] thieno[3,2-b]thiophene (DNTT) is used as an air-stable organic semiconductor to form a channel layer (26) (SI Appendix, Fig.”
Xu, L., Gutbrod, S. R., Bonifas, A. P., Su, Y., Sulkin, M. S., Lu, N., Chung, H.-J., Jang, K.-I., Liu, Z., Ying, M., et al. (2014) · Nature Communications · doi:10.1038/ncomms4329 · Cited by 634
Flexible Wireless Temperature Sensors Based on Ni Microparticle‐Filled Binary Polymer Composites
Jeon, J., Lee, H., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201204082 · Cited by 346 · cited 4×
“Here, we demonstrate a lateral-type sensor where the polymer PTC is printed across two neighboring electrodes (16, 23).”
InfluentialOrganic transistors with high thermal stability for medical applications
Kuribara, K., Wang, H., Uchiyama, N., Fukuda, K., Yokota, T., Zschieschang, U., Jaye, C., Fischer, D., Klauk, H., Yamamoto, T., et al. (2012) · Nature Communications · doi:10.1038/ncomms1721 · Cited by 346 · cited 1×
“It should be noted that organic transistors with DNTT channel layers show negligibly small changes when heated to 40 °C (27).”
Self-citationArora, N., Martins, D., Ruggerio, D., Tousimis, E., Swistel, A. J., Osborne, M. P., & Simmons, R. M. (2008) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2008.06.015 · Cited by 320
Glass transition temperature as a guide to selection of polymers suitable for PTC materials
Meyer, J. (1973) · Polymer Engineering & Science · doi:10.1002/pen.760130611 · Cited by 273 · cited 1×
“The PTC effect in conductive-filled polymers results from an increase in the specific volume as the temperature increases, typically during progression through the melting point of crystalline regions (17, 18).”
Gao, L., Zhang, Y., Malyarchuk, V., Jia, L., Jang, K.-I., Chad Webb, R., Fu, H., Shi, Y., Zhou, G., Shi, L., et al. (2014) · Nature Communications · doi:10.1038/ncomms5938 · Cited by 272 · cited 1×
“Although line-of-sight–based techniques including infrared thermographs and thermotropic liquid crystals (14) are capable of spatial temperature mapping, they require separation between the sensor and target object and, therefore, are unsuitable for implanted devices.”
Flexible Temperature Sensor Array Based on a Graphite-Polydimethylsiloxane Composite
Shih, W.-P., Tsao, L.-C., Lee, C.-W., Cheng, M.-Y., Chang, C., Yang, Y.-J., & Fan, K.-C. (2010) · Sensors · doi:10.3390/s100403597 · Cited by 226
Infrared thermal imaging for detection of peripheral vascular disorders
Philip, J., Bagavathiappan, S., Saravanan, T., Jayakumar, T., Raj, B., Karunanithi, R., Panicker, T. M. R., Korath, M., & Jagadeesan, K. (2009) · Journal of Medical Physics · doi:10.4103/0971-6203.48720 · Cited by 204
Electrical properties of carbon black filled polyethylene
Narkis, M., Ram, A., & Flashner, F. (1978) · Polymer Engineering & Science · doi:10.1002/pen.760180808 · Cited by 182
Electrical properties of Carbon Black Filled Polyethylene
이지용, 변성원, 임승순, & 최영엽 (1993) · 한국고분자학회 학술대회 연구논문 초록집 · Cited by 160
Sumita, M., Abe, H., Kayaki, H., & Miyasaka, K. (1986) · Journal of Macromolecular Science Part B · doi:10.1080/00222348608248036 · Cited by 158 · cited 1×
“With increasing concentration of graphite, the resistivity suddenly decreases to 2 × 10(4) Ωcm at 10 wt % graphite, which is considered the threshold concentration for percolation conduction (21), and remains relatively constant above 10 wt % (SI Appendix, Fig.”
Luo, Y., Wang, G., Zhang, B., & Zhang, Z. (1998) · European Polymer Journal · doi:10.1016/s0014-3057(98)00099-8 · Cited by 112
Gradisar, M., & Lack, L. (2004) · Journal of Biological Rhythms · doi:10.1177/0748730403261560 · Cited by 82 · cited 1×
“Discussion Precise melt temperature tuning is important for realizing multiple human applications, as physiological temperatures range from 32 °C at the fingertips to over 42 °C in the core during hyperpyrexia (29).”
O'Leary, K. A., & Paul, D. R. (2005) · Polymer · doi:10.1016/j.polymer.2005.12.005 · Cited by 73 · cited 1×
“Thus, the tuning of the comonomer ratio of a long and short sidechain monomer allows for precise control of the melt temperature (31).”
Fuketa, H., Yoshioka, K., Shinozuka, Y., Ishida, K., Yokota, T., Matsuhisa, N., Inoue, Y., Sekino, M., Sekitani, T., Takamiya, M., et al. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2314135 · Cited by 71
Self-citationFinal Report on the Safety Assessment of Acrylates Copolymer and 33 Related Cosmetic Ingredients
Fiume, M. Z. (2002) · International Journal of Toxicology · doi:10.1080/10915810290169800 · Cited by 63 · cited 1×
“Alkyl acrylate monomers are widely used in the skin care industry and after polymerization have low toxicity (22).”
International Profiles in Toxicology: Biography of Vincenzo Cuomo, MD, Ph.D.
Carratù, M. R. (2002) · International Journal of Toxicology · doi:10.1080/10915810252825948 · Cited by 60
Arora, I. (2008) · Cited by 58
Solution and bulk properties of branched polyvinyl acetates IV—Melt viscosity
Long, V. C., Berry, G. C., & Hobbs, L. M. (1964) · Polymer · doi:10.1016/0032-3861(64)90200-9 · Cited by 57
O'Leary, K. A., & Paul, D. R. (2006) · Polymer · doi:10.1016/j.polymer.2005.12.006 · Cited by 56
Xu, X.-B., Li, Z.-M., Dai, K., & Yang, M.-B. (2006) · Applied Physics Letters · doi:10.1063/1.2222339 · Cited by 42 · cited 1×
“Competing organic devices suffer in terms of repeatability, commonly exhibiting less than 100 stable thermal cycles (16, 19, 20).”
Chuang, W.-J., Chiu, W., & Tai, H. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm33601d · Cited by 31 · cited 1×
“Here, we demonstrate a lateral-type sensor where the polymer PTC is printed across two neighboring electrodes (16, 23).”
Effect of Thin Film Thicknesses and Materials on the Response of RTDs and Microthermocouples
Imran, M., & Bhattacharyya, A. (2006) · IEEE Sensors Journal · doi:10.1109/jsen.2006.884167 · Cited by 27
Fabrication of amorphous InGaZnO thin-film transistor-driven flexible thermal and pressure sensors
Park, I.-J., Jeong, C.-Y., Cho, I.-T., Lee, J.-H., Cho, E.-S., Kwon, S. J., Kim, B., Cheong, W.-S., Song, S.-H., & Kwon, H.-I. (2012) · Semiconductor Science and Technology · doi:10.1088/0268-1242/27/10/105019 · Cited by 27 · cited 1×
“One practical solution is to apply multiple discrete temperature sensors to the skin such as thermocouples (11), thermistors (12), or resistive temperature detectors (4, 6, 13) with individual wirings for data readout.”
Final Report on the Safety Assessment of Aluminum Starch Octenylsuccinate
Nair, B., & Yamarik, T. A. (2002) · International Journal of Toxicology · doi:10.1080/10915810290096379 · Cited by 25
Temperature topography of the brain cortex: Thermoencephaloscopy
Shevelev, I. A. (1992) · Brain Topography · doi:10.1007/bf01129034 · Cited by 22
Kim, G., & Park, E. (2008) · Journal of Applied Polymer Science · doi:10.1002/app.28200 · Cited by 18
Pulmonary Function in Normal Rats
Whitehead, G. S., Kimmel, E. C., Reboulet, J. E., & Still, K. (1999) · Defense Technical Information Center (DTIC) · Cited by 11
Cited by
Pursuing prosthetic electronic skin
Chortos, A., Liu, J., & Bao, Z. (2016) · Nature Materials · doi:10.1038/nmat4671 · Cited by 2,396
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Self-citationSkin-inspired highly stretchable and conformable matrix networks for multifunctional sensing
Hua, Q., Sun, J., Liu, H., Bao, R., Yu, R., Zhai, J., Pan, C., & Wang, Z. L. (2018) · Nature Communications · doi:10.1038/s41467-017-02685-9 · Cited by 1,413
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Advanced Carbon for Flexible and Wearable Electronics
Wang, C., Xia, K., Wang, H., Liang, X., Yin, Z., & Zhang, Y. (2019) · Advanced Materials · doi:10.1002/adma.201801072 · Cited by 1,300
Metadata
- Authors
- Yokota, T., Inoue, Y., Terakawa, Y., Reeder, J., Kaltenbrunner, M., Ware, T., Yang, K., Mabuchi, K., Murakawa, T., Sekino, M., Voit, W., Sekitani, T., & Someya, T.
- Affiliations
- Japan Science and Technology Agency (JP)
- The University of Tokyo (JP)
- The University of Texas at Dallas (US)
- University of Tokyo Hospital (JP)
- ORCID
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2015-11-09
- Volume
- 112
- Issue
- 47
- Pages
- 14533-14538
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC4664374
- OpenAlex
- W2171005488
- Cited by
- 382
- References
- 39
- Citations by year
- 2026: 14 · 2025: 25 · 2024: 34 · 2023: 34 · 2022: 39 · 2021: 42 · 2020: 53 · 2019: 39 · 2018: 51 · 2017: 35 · 2016: 16
- FWCI
- 16.89
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Japan Society for the Promotion of Science (30723481)
- National Science Foundation (2013155309)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
- Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
- Keywords
- flexible temperature sensors, semicrystalline polymers, multi-point temperature measurement, spatial temperature gradient, in vivo temperature measurement, rat lung, body temperature
- MeSH terms
- Animals, Body Temperature, Graphite, Polymers, X-Ray Diffraction, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.