Real-time monitoring of metabolic function in liver-on-chip microdevices tracks the dynamics of mitochondrial dysfunction
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Significance: Microfluidic organ-on-a-chip technology is poised to replace animal toxicity testing, but thus far has demonstrated few advantages over traditional methods. Here we demonstrate a sensor-integrated platform permitting real-time tracking of the dynamics of metabolic adaptation to mitochondrial dysfunction. Our approach permits detection of chemical toxicity before any effects on cell or tissue viability can be observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250 · cited 2×
“Fiore M, Zanier R, Degrassi F (2002) Reversible G(1) arrest by dimethyl sulfoxide as a new method to synchronize Chinese hamster cells.”
BackgroundMethodTaking Cell-Matrix Adhesions to the Third Dimension
Cukierman, E., Pankov, R., Stevens, D. R., & Yamada, K. M. (2001) · Science · doi:10.1126/science.1064829 · Cited by 3,027
Microfluidic Large-Scale Integration: The Evolution of Design Rules for Biological Automation
Melin, J., & Quake, S. R. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132646 · Cited by 738
Moussaieff, A., Rouleau, M., Kitsberg, D., Cohen, M., Levy, G., Barasch, D., Nemirovski, A., Shen-Orr, S., Laevsky, I., Amit, M., et al. (2015) · Cell Metabolism · doi:10.1016/j.cmet.2015.02.002 · Cited by 666 · cited 1×
“Mitochondrial function plays a critical role in the development of disease and chemical toxicity (7, 8), as well as the regulation of stem cell pluripotency (9).”
BackgroundSelf-citationThe adverse outcome pathway concept: A pragmatic tool in toxicology
Vinken, M. (2013) · Toxicology · doi:10.1016/j.tox.2013.08.011 · Cited by 467
Self-citationPerfused multiwell plate for 3D liver tissue engineering
Domansky, K., Inman, W., Serdy, J., Dash, A., Lim, M. H. M., & Griffith, L. G. (2010) · Lab Chip · doi:10.1039/b913221j · Cited by 444
Differentiation of human embryonic stem cells into hepatocytes in 2D and 3D culture systems in vitro
Baharvand, H., Hashemi, S. M., Kazemi Ashtiani, S., & Farrokhi, A. (2006) · The International Journal of Developmental Biology · doi:10.1387/ijdb.052072hb · Cited by 429
Tilles, A. W., Baskaran, H., Roy, P., Yarmush, M. L., & Toner, M. (2001) · Biotechnology and Bioengineering · doi:10.1002/bit.1071 · Cited by 330
Sivaraman, A., Leach, J., Townsend, S., Iida, T., Hogan, B., Stolz, D., Fry, R., Samson, L., Tannenbaum, S., & Griffith, L. (2005) · Current Drug Metabolism · doi:10.2174/138920005774832632 · Cited by 310
Zhang, J., Nuebel, E., Wisidagama, D. R. R., Setoguchi, K., Hong, J. S., Van Horn, C. M., Imam, S. S., Vergnes, L., Malone, C. S., Koehler, C. M., et al. (2012) · Nature Protocols · doi:10.1038/nprot.2012.048 · Cited by 282
Cited by
Hofer, M., & Lutolf, M. P. (2021) · Nature Reviews Materials · doi:10.1038/s41578-021-00279-y · Cited by 1,184
Zhang, Y. S., Aleman, J., Shin, S. R., Kilic, T., Kim, D., Mousavi Shaegh, S. A., Massa, S., Riahi, R., Chae, S., Hu, N., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1612906114 · Cited by 833
Pound, P., & Ritskes-Hoitinga, M. (2018) · Journal of Translational Medicine · doi:10.1186/s12967-018-1678-1 · Cited by 419
Evolution of Biochip Technology: A Review from Lab-on-a-Chip to Organ-on-a-Chip
Azizipour, N., Avazpour, R., Rosenzweig, D. H., Sawan, M., & Ajji, A. (2020) · Micromachines · doi:10.3390/mi11060599 · Cited by 277
Recent Advances in Body-on-a-Chip Systems
Sung, J. H., Wang, Y. I., Narasimhan Sriram, N., Jackson, M., Long, C., Hickman, J. J., & Shuler, M. L. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05293 · Cited by 268
Lauschke, V. M., Hendriks, D. F. G., Bell, C. C., Andersson, T. B., & Ingelman-Sundberg, M. (2016) · Chemical Research in Toxicology · doi:10.1021/acs.chemrestox.6b00150 · Cited by 241
Deng, J., Wei, W., Chen, Z., Lin, B., Zhao, W., Luo, Y., & Zhang, X. (2019) · Micromachines · doi:10.3390/mi10100676 · Cited by 229
Tissue Engineering and Regenerative Medicine: New Trends and Directions—A Year in Review
Gomes, M. E., Rodrigues, M. T., Domingues, R. M. A., & Reis, R. L. (2017) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2017.0081 · Cited by 179
Drug Toxicity Evaluation Based on Organ-on-a-chip Technology: A Review
Cong, Y., Han, X., Wang, Y., Chen, Z., Lu, Y., Liu, T., Wu, Z., Jin, Y., Luo, Y., & Zhang, X. (2020) · Micromachines · doi:10.3390/mi11040381 · Cited by 140
“Changes in mitochondria from oxidative phosphorylation to anaerobic glycolysis indicate impaired mitochondrial function to assess changes in cell viability and metabolic function [68] (Figure 1C).”
BackgroundMethodA critical perspective on 3D liver models for drug metabolism and toxicology studies
Serras, A. S., Rodrigues, J. S., Cipriano, M., Rodrigues, A. V., Oliveira, N. G., & Miranda, J. P. (2021) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2021.626805 · Cited by 138
Challenges and Opportunities in the Design of Liver-on-Chip Microdevices
Ehrlich, A., Duche, D., Ouedraogo, G., & Nahmias, Y. (2019) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-060418-052305 · Cited by 125
Self-citationProgress, obstacles, and limitations in the use of stem cells in organ-on-a-chip models
Wnorowski, A., Yang, H., & Wu, J. C. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.06.001 · Cited by 124
Human biomimetic liver microphysiology systems in drug development and precision medicine
Gough, A., Soto-Gutierrez, A., Vernetti, L., Ebrahimkhani, M. R., Stern, A. M., & Taylor, D. L. (2021) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-020-00386-1 · Cited by 117
Flat and microstructured polymeric membranes in organs-on-chips
Pasman, T., Grijpma, D., Stamatialis, D., & Poot, A. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2018.0351 · Cited by 98
Organs-on-chip monitoring: sensors and other strategies
Kilic, T., Navaee, F., Stradolini, F., Renaud, P., & Carrara, S. (2018) · Microphysiological Systems · doi:10.21037/mps.2018.01.01 · Cited by 96
“measurement of dissolved oxygen (DO), even combined with sensors for pH, glucose and lactate, may preliminarily reveal and prevent from mitochondrial dysfunctions (121).”
BackgroundEngineered Liver Platforms for Different Phases of Drug Development
Ware, B. R., & Khetani, S. R. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.08.001 · Cited by 90
“developed a biochip with a computer-controlled microfluidic switchboard that can simultaneously monitor mitochondrial respiration, glucose, and lactate in HepG2/C3A aggregates in real-time [56].”
BackgroundAdvances in Engineered Liver Models for Investigating Drug-Induced Liver Injury
Lin, C., & Khetani, S. R. (2016) · BioMed Research International · doi:10.1155/2016/1829148 · Cited by 66
Soucy, J. R., Bindas, A. J., Koppes, A. N., & Koppes, R. A. (2019) · iScience · doi:10.1016/j.isci.2019.10.052 · Cited by 62
“developed a holistic determination of mitochondrial function in a liver chip system using a combination of a luminescence and enzyme-based sensors to measure oxygen and glucose/lactose (Figure 9D) (Bavli et al., 2016).”
Kammerer, S. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms221910214 · Cited by 59
“Cells could be cultured for up to 30 days and proved to be suitable for toxicological analysis as shown by testing hepatotoxic compounds, including acetaminophen, amiodarone and troglitazone [116,118,119].”
BackgroundRivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57
Liver–heart on chip models for drug safety
Ferrari, E., & Rasponi, M. (2021) · APL Bioengineering · doi:10.1063/5.0048986 · Cited by 53
Sensors-integrated organ-on-a-chip for biomedical applications
Chen, H., Luo, Z., Lin, X., Zhu, Y., & Zhao, Y. (2023) · Nano Research · doi:10.1007/s12274-023-5651-9 · Cited by 47
Critical Considerations for the Design of Multi-Organ Microphysiological Systems (MPS)
Malik, M., Yang, Y., Fathi, P., Mahler, G. J., & Esch, M. B. (2021) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2021.721338 · Cited by 43
Liver organoids: Current advances and future applications for hepatology
Kim, Y., Kang, M., Mamo, M. G., Adisasmita, M., Huch, M., & Choi, D. (2025) · Clinical and Molecular Hepatology · doi:10.3350/cmh.2024.1040 · Cited by 26
Dufva, M. (2023) · Scientific Reports · doi:10.1038/s41598-023-35043-5 · Cited by 14
Youhanna, S., Taebnia, N., Liang, Y., Cheng, N., Wang, Y., Michel, M., & Lauschke, V. M. (2025) · Advanced Biology · doi:10.1002/adbi.202500337 · Cited by 9
Metadata
- Authors
- Bavli, D., Prill, S., Ezra, E., Levy, G., Cohen, M., Vinken, M., Vanfleteren, J., Jaeger, M., & Nahmias, Y.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2016-04-04
- Volume
- 113
- Issue
- 16
- Pages
- E2231-40
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2320117782
- Cited by
- 362
- References
- 28
- FWCI
- 15.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.