The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
A robust and scalable microfluidic metering method that allows protein crystal growth by free interface diffusion
Open accessAbstract
Producing robust and scalable fluid metering in a microfluidic device is a challenging problem. We developed a scheme for metering fluids on the picoliter scale that is scalable to highly integrated parallel architectures and is independent of the properties of the working fluid. We demonstrated the power of this method by fabricating and testing a microfluidic chip for rapid screening of protein crystallization conditions, a major hurdle in structural biology efforts. The chip has 480 active valves and performs 144 parallel reactions, each of which uses only 10 nl of protein sample. The properties of microfluidic mixing allow an efficient kinetic trajectory for crystallization, and the microfluidic device outperforms conventional techniques by detecting more crystallization conditions while using 2 orders of magnitude less protein sample. We demonstrate that diffraction-quality crystals may be grown and harvested from such nanoliter-volume reactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Self-citationChaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Sparse matrix sampling: a screening method for crystallization of proteins
Jancarik, J., & Kim, S. H. (1991) · Journal of Applied Crystallography · doi:10.1107/s0021889891004430 · Cited by 2,049
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
Manz, A., Harrison, D. J., Verpoorte, E. M. J., Fettinger, J. C., Paulus, A., Lüdi, H., & Widmer, H. M. (1992) · Journal of Chromatography A · doi:10.1016/0021-9673(92)80293-4 · Cited by 1,042
A microfabricated fluorescence-activated cell sorter
Fu, A. Y., Spence, C., Scherer, A., Arnold, F. H., & Quake, S. R. (1999) · Nature Biotechnology · doi:10.1038/15095 · Cited by 878
Self-citationGeneration of Gradients Having Complex Shapes Using Microfluidic Networks
Dertinger, S. K. W., Chiu, D. T., Jeon, N. L., & Whitesides, G. M. (2001) · Analytical Chemistry · doi:10.1021/ac001132d · Cited by 839
Crystallization of Biological Macromolecules
McPherson, A. (1999) · Medical Entomology and Zoology · Cited by 825
Patterned Delivery of Immunoglobulins to Surfaces Using Microfluidic Networks
Delamarche, E., Bernard, A., Schmid, H., Michel, B., & Biebuyck, H. (1997) · Science · doi:10.1126/science.276.5313.779 · Cited by 678
Cited by
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Self-citationReactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Small-scale systems for in vivo drug delivery
LaVan, D. A., McGuire, T., & Langer, R. (2003) · Nature Biotechnology · doi:10.1038/nbt876 · Cited by 1,304
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Controlled microfluidic interfaces
Atencia, J., & Beebe, D. J. (2005) · Nature · doi:10.1038/nature04163 · Cited by 1,006
Type IIA topoisomerase inhibition by a new class of antibacterial agents
Bax, B. D., Chan, P. F., Eggleston, D. S., Fosberry, A., Gentry, D. R., Gorrec, F., Giordano, I., Hann, M. M., Hennessy, A., Hibbs, M., et al. (2010) · Nature · doi:10.1038/nature09197 · Cited by 860
Polymer microfabrication technologies for microfluidic systems
Becker, H., & Gärtner, C. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1692-2 · Cited by 860
Microfluidic Large-Scale Integration: The Evolution of Design Rules for Biological Automation
Melin, J., & Quake, S. R. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132646 · Cited by 738
Self-citationIntegrated microfluidic devices
Erickson, D., & Li, D. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.019 · Cited by 726
Formation of monodisperse bubbles in a microfluidic flow-focusing device
Garstecki, P., Gitlin, I., DiLuzio, W., Whitesides, G. M., Kumacheva, E., & Stone, H. A. (2004) · Applied Physics Letters · doi:10.1063/1.1796526 · Cited by 641
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
Microfluidic Device for Single-Cell Analysis
Wheeler, A. R., Throndset, W. R., Whelan, R. J., Leach, A. M., Zare, R. N., Liao, Y. H., Farrell, K., Manger, I. D., & Daridon, A. (2003) · Analytical Chemistry · doi:10.1021/ac0340758 · Cited by 600
Gale, B. K., Jafek, A. R., Lambert, C. J., Goenner, B. L., Moghimifam, H., Nze, U. C., & Kamarapu, S. K. (2018) · Inventions · doi:10.3390/inventions3030060 · Cited by 511
A nanoliter-scale nucleic acid processor with parallel architecture
Hong, J. W., Studer, V., Hang, G., Anderson, W. F., & Quake, S. R. (2004) · Nature Biotechnology · doi:10.1038/nbt951 · Cited by 470
Self-citationZheng, B., Tice, J. D., Roach, L. S., & Ismagilov, R. F. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200453974 · Cited by 398
Hong, J. W., & Quake, S. R. (2003) · Nature Biotechnology · doi:10.1038/nbt871 · Cited by 387
Self-citationInterplay between materials and microfluidics
Hou, X., Zhang, Y. S., Santiago, G. T.-D., Alvarez, M. M., Ribas, J., Jonas, S. J., Weiss, P. S., Andrews, A. M., Aizenberg, J., & Khademhosseini, A. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.16 · Cited by 387
Label-free biological and chemical sensors
Hunt, H. K., & Armani, A. M. (2010) · Nanoscale · doi:10.1039/c0nr00201a · Cited by 371
Process analytical technology (PAT) for biopharmaceutical products
Rathore, A. S., Bhambure, R., & Ghare, V. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3781-x · Cited by 368
Microfluidics: reframing biological enquiry
Duncombe, T. A., Tentori, A. M., & Herr, A. E. (2015) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm4041 · Cited by 345
First-principles and direct design approaches for the control of pharmaceutical crystallization
Fujiwara, M., Nagy, Z. K., Chew, J. W., & Braatz, R. D. (2005) · Journal of Process Control · doi:10.1016/j.jprocont.2004.08.003 · Cited by 344
Advances and New Directions in Crystallization Control
Nagy, Z. K., & Braatz, R. D. (2012) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-062011-081043 · Cited by 332
Kang, L., Chung, B. G., Langer, R., & Khademhosseini, A. (2008) · Drug Discovery Today · doi:10.1016/j.drudis.2007.10.003 · Cited by 325
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Heyries, K. A., Tropini, C., VanInsberghe, M., Doolin, C., Petriv, O. I., Singhal, A., Leung, K., Hughesman, C. B., & Hansen, C. L. (2011) · Nature Methods · doi:10.1038/nmeth.1640 · Cited by 305
Self-citationAn integrated AC electrokinetic pump in a microfluidic loop for fast and tunable flow control
Studer, V., Pépin, A., Chen, Y., & Ajdari, A. (2004) · The Analyst · doi:10.1039/b408382m · Cited by 290
Microfluidics in structural biology: smaller, faster… better
Hansen, C. (2003) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2003.09.010 · Cited by 268
Self-citationMicrofluidics in Inorganic Chemistry
Abou‐Hassan, A., Sandre, O., & Cabuil, V. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200904285 · Cited by 259
Chip in a lab: microfluidics for next generation life science research
Streets, A. M., & Huang, Y. (2013) · Biomicrofluidics · doi:10.1063/1.4789751 · Cited by 180
Metadata
- Authors
- Hansen, C. L., Skordalakes, E., Berger, J. M., & Quake, S. R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2002-12-16
- Volume
- 99
- Issue
- 26
- Pages
- 16531-16536
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2078863041
- Cited by
- 517
- References
- 24
- FWCI
- 22.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.