Motility is a fundamental property of mammalian cells that normally is observed in tissue culture by time lapse microscopy where resolution is limited by the wavelength of light. This paper examines a powerful electrical technique by which cell motion is quantitatively measured at the nanometer level. In this method, the cells are cultured on small evaporated gold electrodes carrying weak ac currents. A large change in the measured electrical impedance of the electrodes is observed when cells attach and spread on these electrodes. When the impedance is tracked as a function of time, fluctuations are observed that are a direct measure of cell motion. Surprisingly, these fluctuations continue even when the cell layer becomes confluent. By comparing the measured impedance with a theoretical model, it is clear that under these circumstances the average motions of the cell layer of 1 nm can be inferred from the measurements. We refer to this aspect of cell motility as micromotion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monitoring fibroblast behavior in tissue culture with an applied electric field.
Giaever, I., & Keese, C. R. (1984) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.81.12.3761 · Cited by 608
Self-citationFormation of cell-to-substrate contacts during fibroblast motility: An interference-reflexion study
Izzard, C. S., & Lochner, L. R. (1980) · Journal of Cell Science · doi:10.1242/jcs.42.1.81 · Cited by 304
Use of Electric Fields to Monitor the Dynamical Aspect of Cell Behavior in Tissue Culture
Giaever, I., & Keese, C. R. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325896 · Cited by 275
Self-citationAdvanced Calculus for Engineers.
Reid, W. P., & Hildebrand, F. B. (1951) · The American Mathematical Monthly · doi:10.2307/2307775 · Cited by 251
Fuller, S., von Bonsdorff, C.-H., & Simons, K. (1984) · Cell · doi:10.1016/0092-8674(84)90527-0 · Cited by 236
Fourier analysis of cell motility: correlation of motility with metastatic potential.
Partin, A. W., Schoeniger, J. S., Mohler, J. L., & Coffey, D. S. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.4.1254 · Cited by 184
Partin, A. W., Isaacs, J. T., Treiger, B. F. G., & Coffey, D. S. (1988) · PubMed · Cited by 74
Cited by
A morphological biosensor for mammalian cells
Giaever, I., & Keese, C. R. (1993) · Nature · doi:10.1038/366591a0 · Cited by 770
Self-citationWegener, J., Keese, C. R., & Giaever, I. (2000) · Experimental Cell Research · doi:10.1006/excr.2000.4919 · Cited by 769
Self-citationTiruppathi, C., Malik, A. B., Del Vecchio, P. J., Keese, C. R., & Giaever, I. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.17.7919 · Cited by 433
Self-citationA review of impedance measurements of whole cells
Xu, Y., Xie, X., Duan, Y., Wang, L., Cheng, Z., & Cheng, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.027 · Cited by 424
Electrical wound-healing assay for cells in vitro
Keese, C. R., Wegener, J., Walker, S. R., & Giaever, I. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0307588100 · Cited by 421
Self-citationImpedance-based cell monitoring: barrier properties and beyond
Benson, K., Cramer, S., & Galla, H.-J. (2013) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-10-5 · Cited by 400
Development and Application of Cell-Based Biosensors
Pancrazio, J. J., Whelan, J. P., Borkholder, D. A., Ma, W., & Stenger, D. A. (1999) · Annals of Biomedical Engineering · doi:10.1114/1.225 · Cited by 391
Application of Real-Time Cell Electronic Sensing (RT-CES) Technology to Cell-Based Assays
Solly, K., Wang, X., Xu, X., Strulovici, B., & Zheng, W. (2004) · ASSAY and Drug Development Technologies · doi:10.1089/adt.2004.2.363 · Cited by 381
Good, R. B., Gilbane, A. J., Trinder, S. L., Denton, C. P., Coghlan, G., Abraham, D. J., & Holmes, A. M. (2015) · The American Journal of Pathology · doi:10.1016/j.ajpath.2015.03.019 · Cited by 349
“Barrier function of PAECs, I-EndoMT cells, andmixed cultures of I-EndoMT/PAECs (1:10 ratio) were quantified with electrical cell-substrate impedance sensing (ECIS; Applied BioPhysics, Troy, NY) as previously described.(25) Cells were seeded at 5 10(4) cells/0.”
MethodBioelectrical impedance assay to monitor changes in cell shape during apoptosis
Arndt, S., Seebach, J., Psathaki, K., Galla, H.-J., & Wegener, J. (2004) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00269-0 · Cited by 318
Zhang, R., & Xie, X. (2012) · Acta Pharmacologica Sinica · doi:10.1038/aps.2011.173 · Cited by 317
Impedance analysis of MDCK cells measured by electric cell-substrate impedance sensing
Lo, C. M., Keese, C. R., & Giaever, I. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80153-0 · Cited by 272
Self-citationRetinoic Acid Induces Blood–Brain Barrier Development
Mizee, M. R., Wooldrik, D., Lakeman, K. A. M., van het Hof, B., Drexhage, J. A. R., Geerts, D., Bugiani, M., Aronica, E., Mebius, R. E., Prat, A., et al. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.1338-12.2013 · Cited by 203
“…furthermore subjected to a mathematical model to calculate the component of resistance attributed to cell– cell interactions, called barrier resistance (Rb), and the component derived from average membrane capacitance of cells covering the electrode (membrane capacitance) (Giaever and Keese, 1991).”
BackgroundMethodNguyen, T. A., Yin, T.-I., Reyes, D., & Urban, G. A. (2013) · Analytical Chemistry · doi:10.1021/ac402761s · Cited by 189
Human In Vitro Skin Models for Wound Healing and Wound Healing Disorders
Hofmann, E., Fink, J., Pignet, A.-L., Schwarz, A., Schellnegger, M., Nischwitz, S. P., Holzer-Geissler, J. C. J., Kamolz, L.-P., & Kotzbeck, P. (2023) · Biomedicines · doi:10.3390/biomedicines11041056 · Cited by 104
Hildebrandt, C., Büth, H., Cho, S., Impidjati, & Thielecke, H. (2010) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2010.01.007 · Cited by 95
Wu, S., Liu, X., Zhou, X., Liang, X. M., Gao, D., Liu, H., Zhao, G., Zhang, Q., & Wu, X. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.09.024 · Cited by 64
Engel, N., Dau, M., Engel, V., Franz, D., Klemmstein, F., Thanisch, C., Kolb, J. F., Frank, M., Springer, A., Köhling, R., et al. (2023) · Biomedicines · doi:10.3390/biomedicines11030697 · Cited by 10
Metadata
- Authors
- Giaever, I., & Keese, C. R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1991-09
- Volume
- 88
- Issue
- 17
- Pages
- 7896-7900
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2038628992
- Cited by
- 828
- References
- 7
- FWCI
- 1.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.