A validation study of Fitbit Charge 2™ compared with polysomnography in adults
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
We evaluated the performance of a consumer multi-sensory wristband (Fitbit Charge 2™), against polysomnography (PSG) in measuring sleep/wake state and sleep stage composition in healthy adults. In-lab PSG and Fitbit Charge 2™ data were obtained from a single overnight recording at the SRI Human Sleep Research Laboratory in 44 adults (19-61 years; 26 women; 25 Caucasian). Participants were screened to be free from mental and medical conditions. Presence of sleep disorders was evaluated with clinical PSG. PSG findings indicated periodic limb movement of sleep (PLMS, > 15/h) in nine participants, who were analyzed separately from the main group (n = 35). PSG and Fitbit Charge 2™ sleep data were compared using paired t-tests, Bland-Altman plots, and epoch-by-epoch (EBE) analysis. In the main group, Fitbit Charge 2™ showed 0.96 sensitivity (accuracy to detect sleep), 0.61 specificity (accuracy to detect wake), 0.81 accuracy in detecting N1+N2 sleep ("light sleep"), 0.49 accuracy in detecting N3 sleep ("deep sleep"), and 0.74 accuracy in detecting rapid-eye-movement (REM) sleep. Fitbit Charge 2™ significantly (p < 0.05) overestimated PSG TST by 9 min, N1+N2 sleep by 34 min, and underestimated PSG SOL by 4 min and N3 sleep by 24 min. PSG and Fitbit Charge 2™ outcomes did not differ for WASO and time spent in REM sleep. No more than two participants fell outside the Bland-Altman agreement limits for all sleep measures. Fitbit Charge 2™ correctly identified 82% of PSG-defined non-REM-REM sleep cycles across the night. Similar outcomes were found for the PLMS group. Fitbit Charge 2™ shows promise in detecting sleep-wake states and sleep stage composition relative to gold standard PSG, particularly in the estimation of REM sleep, but with limitations in N3 detection. Fitbit Charge 2™ accuracy and reliability need to be further investigated in different settings (at-home, multiple nights) and in different populations in which sleep composition is known to vary (adolescents, elderly, patients with sleep disorders).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
The Pittsburgh Sleep Quality Index: a new instrument for psychiatric practice and research
Buysse, D. J., Reynolds, C. F., Monk, T. H., Berman, S. R., & Kupfer, D. J. (1989) · Psychiatry Research · doi:10.1016/0165-1781(89)90047-4 · Cited by 35,234
(1992) · PubMed · Cited by 33,716
The MOS 36-ltem Short-Form Health Survey (SF-36): I. Conceptual Framework and Item Selection
Ware, J. E., & Sherbourne, C. D. (1992) · Medical Care · doi:10.1097/00005650-199206000-00002 · Cited by 30,033
Validation of the Insomnia Severity Index as an outcome measure for insomnia research
Bastien, C. (2001) · Sleep Medicine · doi:10.1016/s1389-9457(00)00065-4 · Cited by 8,067 · cited 3×
“BMI, body mass index; DBP, diastolic blood pressure; ISI, insomnia severity index; PLMS, periodic limb movement of sleep; SBP, systolic blood pressure; SF-36, 36-Item Short Form Health Survey.”
BackgroundMethod(2007) · Cited by 6,530
Principles and Practice of Sleep Medicine
(2011) · Elsevier eBooks · doi:10.1016/c2009-0-59875-3 · Cited by 5,088
The International Classification of Sleep Disorders: Diagnostic and Coding Manual
Daroff, R. B. (1991) · Neurology · doi:10.1212/wnl.41.1.160 · Cited by 5,014
The Rise of Consumer Health Wearables: Promises and Barriers
Piwek, L., Ellis, D. A., Andrews, S., & Joinson, A. (2016) · PLOS Medicine · doi:10.1371/journal.pmed.1001953 · Cited by 1,235
Principles and Practice of Sleep Medicine
(2017) · Elsevier eBooks · doi:10.1016/c2012-0-03543-0 · Cited by 783
Grandner, M. A. (2017) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2016.10.012 · Cited by 720 · cited 1×
“Sleep is fundamental for health and wellness, and insufficient sleep is linked to severe adverse outcomes including obesity, cardiovascular diseases, diabetes, mood disorders, and mortality (Grandner 2017).”
BackgroundVAN DE WATER, A. T. M., HOLMES, A., & HURLEY, D. A. (2011) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2009.00814.x · Cited by 447
Systematic Trends Across the Night in Human Sleep Cycles
Feinberg, I., & Floyd, T. C. (1979) · Psychophysiology · doi:10.1111/j.1469-8986.1979.tb02991.x · Cited by 393
Wake Detection Capacity of Actigraphy During Sleep
Paquet, J., Kawinska, A., & Carrier, J. (2007) · Sleep · doi:10.1093/sleep/30.10.1362 · Cited by 352
Mantua, J., Gravel, N., & Spencer, R. (2016) · Sensors · doi:10.3390/s16050646 · Cited by 314 · cited 5×
“Similar performance (based on PSG-device discrepancies only) between standard actigraphy and wearables is also suggested by Mantua et al. (2016) who compared four different sleep-trackers (Basic Health Tracker 2014 Ed., Fitbit Flex™, Misfit Shine™, Withings Pulse O2) worn on the wrist, and…”
BackgroundInfluentialMovement toward a novel activity monitoring device
Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0585-y · Cited by 301 · cited 3×
“…studies assessing the accuracy of older Fitbit models, which relied on only motion to determine sleep/wake states [Fitbit “original”, specificity of 0.20 (Montgomery-Downs et al. 2012); Fitbit Flex, specificity of 0.35 (Cook et al. 2017) and 0.36 (Kang et al. 2017); Fitbit Ultra, specificity of…”
BackgroundInfluentialBaharav, A., Kotagal, S., Gibbons, V., Rubin, B. K., Pratt, G., Karin, J., & Akselrod, S. (1995) · Neurology · doi:10.1212/wnl.45.6.1183 · Cited by 290
The Sleep of the Ring: Comparison of the ŌURA Sleep Tracker Against Polysomnography
de Zambotti, M., Rosas, L., Colrain, I. M., & Baker, F. C. (2019) · Behavioral Sleep Medicine · doi:10.1080/15402002.2017.1300587 · Cited by 287 · cited 1×
“Our group previously investigated the performance of another multisensory sleep-tracker (the ŌURA ring) in a sample of healthy adolescents (de Zambotti et al. 2017).”
BackgroundSelf-citationMeltzer, L. J., Hiruma, L. S., Avis, K., Montgomery-Downs, H., & Valentin, J. (2015) · Sleep · doi:10.5665/sleep.4918 · Cited by 228
de Zambotti, M., Baker, F. C., Willoughby, A. R., Godino, J. G., Wing, D., Patrick, K., & Colrain, I. M. (2016) · Physiology & Behavior · doi:10.1016/j.physbeh.2016.03.006 · Cited by 222 · cited 4×
“…sleep/wake states [Fitbit “original”, specificity of 0.20 (Montgomery-Downs et al. 2012); Fitbit Flex, specificity of 0.35 (Cook et al. 2017) and 0.36 (Kang et al. 2017); Fitbit Ultra, specificity of 0.52 (Meltzer et al. 2015); Fitbit Charge HR™, specificity of 0.42 (de Zambotti et al. 2016a)].”
BackgroundResultInfluentialSelf-citationSforza, E., Nicolas, A., Lavigne, G., Gosselin RPGST, A., Petit, D., & Montplaisir, J. (1999) · Neurology · doi:10.1212/wnl.52.4.786 · Cited by 222
Prevalence and determinants of periodic limb movements in the general population
Haba‐Rubio, J., Marti‐Soler, H., Marques‐Vidal, P., Tobback, N., Andries, D., Preisig, M., Waeber, G., Vollenweider, P., Kutalik, Z., Tafti, M., et al. (2016) · Annals of Neurology · doi:10.1002/ana.24593 · Cited by 168
Toon, E., Davey, M. J., Hollis, S. L., Nixon, G. M., Horne, R. S. C., & Biggs, S. N. (2016) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.5580 · Cited by 161
Validation of Sleep-Tracking Technology Compared with Polysomnography in Adolescents
de Zambotti, M., Baker, F. C., & Colrain, I. M. (2015) · Sleep · doi:10.5665/sleep.4990 · Cited by 160
Self-citationKang, S.-G., Kang, J. M., Ko, K.-P., Park, S.-C., Mariani, S., & Weng, J. (2017) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2017.03.009 · Cited by 146
Consumer sleep tracking devices: a review of mechanisms, validity and utility
Kolla, B. P., Mansukhani, S., & Mansukhani, M. P. (2016) · Expert Review of Medical Devices · doi:10.1586/17434440.2016.1171708 · Cited by 144
Otzenberger, H., Simon, C., Gronfier, C., & BRANDENBERGER, G. (1997) · Neuroscience Letters · doi:10.1016/s0304-3940(97)00448-5 · Cited by 112
Cook, J. D., Prairie, M. L., & Plante, D. T. (2017) · Journal of Affective Disorders · doi:10.1016/j.jad.2017.04.030 · Cited by 104
On the Nature of Cardiovascular Activation at an Arousal from Sleep
(2003) · Sleep · doi:10.1093/sleep/26.5.543 · Cited by 99
Aktaruzzaman, M., Rivolta, M. W., Karmacharya, R., Scarabottolo, N., Pugnetti, L., Garegnani, M., Bovi, G., Scalera, G. M., Ferrarin, M., & Sassi, R. (2017) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.08.006 · Cited by 57
The Boom in Wearable Technology: Cause for Alarm or Just What is Needed to Better Understand Sleep?
de Zambotti, M., Godino, J. G., Baker, F. C., Cheung, J., Patrick, K., & Colrain, I. M. (2016) · Sleep · doi:10.5665/sleep.6108 · Cited by 50
Self-citationImproving actigraph sleep/wake classification with cardio-respiratory signals
Karlen, W., Mattiussi, C., & Floreano, D. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650401 · Cited by 48
Estimating sleep from multisensory armband measurements: validity and reliability in teens
Roane, B. M., Van Reen, E., Hart, C. N., Wing, R., & Carskadon, M. A. (2015) · Journal of Sleep Research · doi:10.1111/jsr.12317 · Cited by 43
Fitbit Flex: an unreliable device for longitudinal sleep measures in a non-clinical population
Baroni, A., Bruzzese, J., Bartolo, C. A. D., & Shatkin, J. P. (2015) · Sleep And Breathing · doi:10.1007/s11325-015-1271-2 · Cited by 40
K-Complexes: Interaction between the Central and Autonomic Nervous Systems during Sleep
de Zambotti, M., Willoughby, A. R., Franzen, P. L., Clark, D. B., Baker, F. C., & Colrain, I. M. (2016) · Sleep · doi:10.5665/sleep.5770 · Cited by 40
Self-citation0068 ESTIMATION OF SLEEP STAGES USING CARDIAC AND ACCELEROMETER DATA FROM A WRIST-WORN DEVICE
Beattie, Z., Pantelopoulos, A., Ghoreyshi, A., Oyang, Y., Statan, A., & Heneghan, C. (2017) · Sleep · doi:10.1093/sleepj/zsx050.067 · Cited by 29
Cited by
Wearable Sleep Technology in Clinical and Research Settings
DE ZAMBOTTI, M., CELLINI, N., GOLDSTONE, A., COLRAIN, I. M., & BAKER, F. C. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001947 · Cited by 564
Self-citationPeake, J. M., Kerr, G., & Sullivan, J. P. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00743 · Cited by 523
Metrics of sleep apnea severity: beyond the apnea-hypopnea index
Malhotra, A., Ayappa, I., Ayas, N., Collop, N., Kirsch, D., Mcardle, N., Mehra, R., Pack, A. I., Punjabi, N., White, D. P., et al. (2021) · SLEEP · doi:10.1093/sleep/zsab030 · Cited by 489
Accuracy of Wristband Fitbit Models in Assessing Sleep: Systematic Review and Meta-Analysis
Haghayegh, S., Khoshnevis, S., Smolensky, M. H., Diller, K. R., & Castriotta, R. J. (2019) · Journal of Medical Internet Research · doi:10.2196/16273 · Cited by 446
Performance of seven consumer sleep-tracking devices compared with polysomnography
Chinoy, E. D., Cuellar, J. A., Huwa, K. E., Jameson, J. T., Watson, C. H., Bessman, S. C., Hirsch, D. A., Cooper, A. D., Drummond, S. P. A., & Markwald, R. R. (2021) · Sleep · doi:10.1093/sleep/zsaa291 · Cited by 433
Metadata
- Authors
- de Zambotti, M., Goldstone, A., Claudatos, S., Colrain, I. M., & Baker, F. C.
- Venue
- Chronobiology International
- Publisher
- Informa UK Limited
- Published
- 2017-12-13
- Volume
- 35
- Issue
- 4
- Pages
- 465-476
- ISSN
- 0742-0528 (ISSN-L)
- 1525-6073
- OpenAlex
- W2775576072
- Cited by
- 413
- References
- 36
- FWCI
- 36.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.