Blood pressure control during telemonitoring of home blood pressure. A randomized controlled trial during 6 months
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
AIM: To compare the effectiveness of antihypertensive treatment based on telemonitoring of home blood pressure (BP) and conventional monitoring of office BP. METHODS: Hypertensive patients (n = 236) participated in a randomized, controlled study. In the intervention group, antihypertensive treatment was based on home BP monitoring. BP readings were registered by a PDA and automatically transmitted to a server, by which the patient and doctor could communicate. In the control group, patients received usual care with office visits to adjust antihypertensive treatment as needed. Primary outcome was difference in systolic daytime ambulatory BP monitoring (ABPM) change between baseline and 6 months. RESULTS: In both groups, systolic daytime ABPM decreased significantly from baseline to follow-up. The decrease in systolic daytime ABPM was -11.9 mmHg in the intervention group and -9.6 mmHg in the control group (mean difference -2.3 [95% CI -6.1 to -1.5], p = 0.225). The likelihood of daytime ABPM normalization was similar in the two groups [32/113 (28%) vs 46/123 (37%), p = 0.139]. CONCLUSION: Antihypertensive treatment based on telemonitoring of home BP was as effective as usual monitoring of office BP with regards to reduction of BP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Staessen, J. A. (2004) · JAMA · doi:10.1001/jama.291.8.955 · Cited by 288
Home Blood Pressure Measurement
Verberk, W. J., Kroon, A. A., Kessels, A. G. H., & de Leeuw, P. W. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.058 · Cited by 212
Research works printed but not linked: 21
- 10.1097/HJH.0b013e3281fc975a · DOI · Paper page
- 10.1001/jama.289.19.2560 · DOI · Paper page
- Rogers M. A. M., 2002, J Telemed and Telecare, 244
- 10.1080/08037050310000472 · DOI
- 10.1038/sj.jhh.1001584 · DOI
- 10.1136/bmj.38121.684410.AE · DOI · Paper page
- 10.1001/archinte.1980.00330220015009 · DOI
- 10.1016/j.amjhyper.2005.05.017 · DOI · Paper page
- 10.1016/0895-7061(95)00353-3 · DOI · Paper page
- 10.1097/01.hjh.0000198023.53859.a2 · DOI · Paper page
- 10.1016/S0895-7061(04)00867-2 · DOI
- 10.1016/S0895-7061(98)00241-6 · DOI · Paper page
- 10.1001/archinte.159.22.2689 · DOI · Paper page
- Nordmann A., 2000, BMJ, 9, 200
- 10.1007/s11906-996-0020-0 · DOI
- 10.1089/107830200311815 · DOI · Paper page
- 10.1067/mhl.2001.112684 · DOI · Paper page
- 10.7326/0003-4819-134-11-200106050-00008 · DOI · Paper page
- 10.1097/00004872-200306000-00001 · DOI · Paper page
- El Assaad M. A., 2001, Blood Press Monit, 8, 127, 10.1097/00126097-200306000-00006 · DOI · Paper page
- 10.1136/bmj.322.7285.531 · DOI · Paper page
Cited by
The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2019)
Umemura, S., Arima, H., Arima, S., Asayama, K., Dohi, Y., Hirooka, Y., Horio, T., Hoshide, S., Ikeda, S., Ishimitsu, T., et al. (2019) · Hypertension Research · doi:10.1038/s41440-019-0284-9 · Cited by 1,880
Hamine, S., Gerth-Guyette, E., Faulx, D., Green, B. B., & Ginsburg, A. S. (2015) · Journal of Medical Internet Research · doi:10.2196/jmir.3951 · Cited by 1,149
Interactive telemedicine: effects on professional practice and health care outcomes
Flodgren, G., Rachas, A., Farmer, A. J., Inzitari, M., & Shepperd, S. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002098.pub2 · Cited by 806
Tucker, K. L., Sheppard, J. P., Stevens, R., Bosworth, H. B., Bove, A., Bray, E. P., Earle, K., George, J., Godwin, M., Green, B. B., et al. (2017) · PLOS Medicine · doi:10.1371/journal.pmed.1002389 · Cited by 658
Burke, L. E., Ma, J., Azar, K. M. J., Bennett, G. G., Peterson, E. D., Zheng, Y., Riley, W., Stephens, J., Shah, S. H., Suffoletto, B., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000232 · Cited by 516
Agarwal, R., Bills, J. E., Hecht, T. J. W., & Light, R. P. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.160911 · Cited by 430
Uhlig, K., Patel, K., Ip, S., Kitsios, G. D., & Balk, E. M. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-159-3-201308060-00008 · Cited by 368
“Description of Included Studies* Author, Year (Reference) SMBP Monitoring vs. Usual Care SMBP Monitoring AS vs. Usual Care SMBP Monitoring AS vs. SMBP Monitoring ± AS Total Patients, n Intervention Duration† Quality Grade Artinian et al, 2001 (8) X 15 SMBP monitoring counseling Usual care 3 mo B Artinian et al, 2007 (…”
MethodOmboni, S., Gazzola, T., Carabelli, G., & Parati, G. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e32835ca8dd · Cited by 313
“These 23 studies were, thus, included in the meta-analysis [24–46].”
BackgroundBray, E. P., Holder, R., Mant, J., & McManus, R. J. (2010) · Annals of Medicine · doi:10.3109/07853890.2010.489567 · Cited by 245
McKinstry, B., Hanley, J., Wild, S., Pagliari, C., Paterson, M., Lewis, S., Sheikh, A., Krishan, A., Stoddart, A., & Padfield, P. (2013) · BMJ · doi:10.1136/bmj.f3030 · Cited by 199
Duan, Y., Xie, Z., Dong, F., Wu, Z., Lin, Z., Sun, N., & Xu, J. (2017) · Journal of Human Hypertension · doi:10.1038/jhh.2016.99 · Cited by 154
Nangalia, V., Prytherch, D. R., & Smith, G. B. (2010) · Critical Care · doi:10.1186/cc9208 · Cited by 150
“However, other studies have not shown any change in measured parameters with home-based monitoring and intervention for asthma [20] or hypertension [21].”
BackgroundAbaza, H., & Marschollek, M. (2017) · Methods of Information in Medicine · doi:10.3414/me17-05-0003 · Cited by 138
“Most apps resulted in significant improvements in systolic blood pressure [55, 57, 58], allcause mortality and heart failure hospitalizations [54], heart failure prognosis [56], and patients’ exercise capacity (walking distance) [59].”
BackgroundBeishuizen, C. R., Stephan, B. C., van Gool, W. A., Brayne, C., Peters, R. J., Andrieu, S., Kivipelto, M., Soininen, H., Busschers, W. B., Moll van Charante, E. P., et al. (2016) · Journal of Medical Internet Research · doi:10.2196/jmir.5218 · Cited by 128
Omboni, S., & Guarda, A. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2011.100 · Cited by 108
“aIn one study (30) ambulatory SBP/DBP was defined as the whole 24-h average (121 subjects), while in two studies (33,35) ambulatory SBP/DBP was defined as day-time average (534 subjects).”
BackgroundLeo, D. G., Buckley, B. J. R., Chowdhury, M., Harrison, S. L., Isanejad, M., Lip, G. Y. H., Wright, D. J., Lane, D. A., & the TAILOR investigators (2022) · Journal of Medical Internet Research · doi:10.2196/35508 · Cited by 62
“In the subgroup analysis according to study time points, similar results were observed for SBP at 6 months (weighted MD=−3.85 mm Hg, 95% CI −7.03 to −0.68; P =.02; I 2 =100%; Figure 5 [15,17,24,38,45,62,72,75,77,90].”
InfluentialStogios, N., Kaur, B., Huszti, E., Vasanthan, J., & Nolan, R. P. (2020) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2019.11.010 · Cited by 33
Hayek, M. A., Giannouchos, T., Lawley, M., & Kum, H.-C. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.44372 · Cited by 32
Satoh, M., Maeda, T., Hoshide, S., & Ohkubo, T. (2019) · Hypertension Research · doi:10.1038/s41440-019-0221-y · Cited by 28
Satoh, M., Tatsumi, Y., Nakayama, S., Shinohara, Y., Kawazoe, M., Nozato, Y., Kunimura, A., Murakami, T., Toyama, M., Muroya, T., et al. (2025) · Hypertension Research · doi:10.1038/s41440-024-01981-4 · Cited by 25
Shantharam, S. S., Mahalingam, M., Rasool, A., Reynolds, J. A., Bhuiya, A. R., Satchell, T. D., Chapel, J. M., Hawkins, N. A., Jones, C. D., Jacob, V., et al. (2022) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2021.06.025 · Cited by 13
Grover, S., Mishra, H. P., Gupta, R., & Gupta, L. K. (2025) · Journal of Hypertension · doi:10.1097/hjh.0000000000004008 · Cited by 8
Metadata
- Authors
- Madsen, L. B., Kirkegaard, P., & Pedersen, E. B.
- Venue
- Blood Pressure
- Publisher
- Informa UK Limited
- Published
- 2008-01-01
- Volume
- 17
- Issue
- 2
- Pages
- 78-86
- ISSN
- 0803-7051 (ISSN-L)
- 1651-1999
- OpenAlex
- W2066969035
- Cited by
- 79
- References
- 2
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.