Single-ion, transportable optical atomic clocks
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
For the past 15 years, tremendous progress within the fields of laser stabilization, optical frequency combs and atom cooling and trapping have allowed the realization of optical atomic clocks with unrivaled performances. These instruments can perform frequency comparisons with fractional uncertainties well below 10-17, finding applications in fundamental physics tests, relativistic geodesy and time and frequency metrology. Even though most optical clocks are currently laboratory setups, several proposals for using these clocks for field measurements or within an optical clock network have been published, and most of time and frequency metrology institutes have started to develop transportable optical clocks. For the purpose of this special issue, we chose to focus on trapped-ion optical clocks. Even though their short-term fractional frequency stability is impaired by a lower signal-to-noise ratio, they offer a high potential for compactness: trapped ions demand low optical powers and simple loading schemes, and can be trapped in small vacuum chambers. We review recent advances on the clock key components, including ion trap and ultra-stable optical cavity, as well as existing projects and experiments which draw the picture of what future transportable, single-ion optical clocks may resemble.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, D. J., Diddams, S. A., Ranka, J. K., Stentz, A., Windeler, R. S., Hall, J. L., & Cundiff, S. T. (2000) · Science · doi:10.1126/science.288.5466.635 · Cited by 2,661
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
The Effect of Collisions upon the Doppler Width of Spectral Lines
Dicke, R. H. (1953) · Physical Review · doi:10.1103/physrev.89.472 · Cited by 1,491
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450 · cited 3×
“\quantum logic" spectroscopy protocol was proposed and demonstrated in 2005 (104). It was successfully used by a number of groups since then, and extended to the domain of molecular spectroscopy (57, 123, 124). The underlying idea is to trap a spectroscopy ion together with a logic ion which can be used both to s…”
MethodInfluentialGeneration of Nonclassical Motional States of a Trapped Atom
Meekhof, D. M., Monroe, C., King, B. E., Itano, W. M., & Wineland, D. J. (1996) · Physical Review Letters · doi:10.1103/physrevlett.76.1796 · Cited by 1,135 · cited 1×
“motional states through the Coulomb interaction. The trapped ions motional state can be coherently manipulated using Raman pulses, and internal states can be reversibly transferred to motional states (125). In the quantum logic spectroscopy protocol, a state of motion is therefore used as a transfer state to coherentl…”
MethodFrequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720 · cited 1×
“by laser-cooling (68). The socalled micromotion driven by the RF trapping eld is the main contribution to this shift, and can only be minimized by placing the ion as close to the RF null as possible (69, 70). the electric quadrupole shift, which induces a sensitivity to electric eld gradients for the electronic states…”
BackgroundSingle-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Spectroscopy Using Quantum Logic
Schmidt, P. O., Rosenband, T., Langer, C., Itano, W. M., Bergquist, J. C., & Wineland, D. J. (2005) · Science · doi:10.1126/science.1114375 · Cited by 643 · cited 4×
“erties but do not oer easily addressable transitions for laser cooling and clock state detection. For such species, a \quantum logic" spectroscopy protocol was proposed and demonstrated in 2005 (104). It was successfully used by a number of groups since then, and extended to the domain of molecular spectroscopy (…”
MethodInfluentialQuantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
A 920-Kilometer Optical Fiber Link for Frequency Metrology at the 19th Decimal Place
Predehl, K., Grosche, G., Raupach, S. M. F., Droste, S., Terra, O., Alnis, J., Legero, T., Hänsch, T. W., Udem, T., Holzwarth, R., et al. (2012) · Science · doi:10.1126/science.1218442 · Cited by 543
Hunting for topological dark matter with atomic clocks
Derevianko, A., & Pospelov, M. (2014) · Nature Physics · doi:10.1038/nphys3137 · Cited by 522
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
A clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460
Nuclear laser spectroscopy of the 3.5 eV transition in Th-229
Peik, E., & Tamm, C. (2003) · Europhysics Letters (EPL) · doi:10.1209/epl/i2003-00210-x · Cited by 435
Ion-trap measurements of electric-field noise near surfaces
Brownnutt, M., Kumph, M., Rabl, P., & Blatt, R. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.1419 · Cited by 413
Ultrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385 · cited 3×
“dwas chosen following nite-element analysis, which showed a cancellation of the cavity length change due to the support forces for d= 6:7 mm. The resulting passive acceleration sensitivities are 2.45(3), 0.21(4) and 0.01(1) 10 11=gin the axial and transverse directions, the lowest published values to date. Even though…”
MethodInfluentialImproved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
Optical-Frequency Transfer over a Single-Span 1840 km Fiber Link
Droste, S., Ozimek, F., Udem, T., Predehl, K., Hänsch, T. W., Schnatz, H., Grosche, G., & Holzwarth, R. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.110801 · Cited by 315
8 × 10^−17 fractional laser frequency instability with a long room-temperature cavity
Häfner, S., Falke, S., Grebing, C., Vogt, S., Legero, T., Merimaa, M., Lisdat, C., & Sterr, U. (2015) · Optics Letters · doi:10.1364/ol.40.002112 · Cited by 286
Riehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264 · cited 1×
“uming, and a regular array at a continental scale is hard to contemplate in the mid-term. Transportable optical clocks would provide local and/or temporary links to the emerging optical clock network (27). 2 1.2. Geodesy Transportable optical clocks are at the heart of a new approach to geodesy called chronometric lev…”
BackgroundInfluentialSurface-electrode architecture for ion-trap quantum information processing
Chiaverini, J., Blakestad, R. B., Britton, J., Jost, J. D., Langer, C., Leibfried, D., Ozeri, R., & Wineland, D. J. (2005) · Quantum Information and Computation · doi:10.26421/qic5.6-1 · Cited by 257
Experimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250 · cited 1×
“mparisons, precision spectroscopy, relativistic geodesy, etc. Using an optical frequency comb, it can also be transferred to the radiofrequency (RF) domain, where it can form the basis of a timescale (63, 64). In that regard, the useful signal of an optical atomic clock is actually the RF signal, which is why the opti…”
BackgroundGeopotential measurements with synchronously linked optical lattice clocks
Takano, T., Takamoto, M., Ushijima, I., Ohmae, N., Akatsuka, T., Yamaguchi, A., Kuroishi, Y., Munekane, H., Miyahara, B., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.159 · Cited by 245
Integrated optical addressing of an ion qubit
Mehta, K. K., Bruzewicz, C. D., McConnell, R., Ram, R. J., Sage, J. M., & Chiaverini, J. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.139 · Cited by 242
Transportable Optical Lattice Clock with 7 × 10 − 17 Uncertainty
Koller, S. B., Grotti, J., Vogt, S., Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.073601 · Cited by 238
Frequency ratio of Yb and Sr clocks with 5 × 10−17 uncertainty at 150 seconds averaging time
Nemitz, N., Ohkubo, T., Takamoto, M., Ushijima, I., Das, M., Ohmae, N., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.20 · Cited by 221
Surface-electrode architecture for ion-trap quantum information processing
(2005) · CERN Document Server (European Organization for Nuclear Research) · doi:10.5555/2011670.2011671 · Cited by 195
Towards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174
Bjerhammar, A. (1985) · Bulletin Géodésique · doi:10.1007/bf02520327 · Cited by 165
Realization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149
Spectral purity transfer between optical wavelengths at the 10−18 level
Nicolodi, D., Argence, B., Zhang, W., Le Targat, R., Santarelli, G., & Le Coq, Y. (2014) · Nature Photonics · doi:10.1038/nphoton.2013.361 · Cited by 132
A VLBI experiment using a remote atomic clock via a coherent fibre link
Clivati, C., Ambrosini, R., Artz, T., Bertarini, A., Bortolotti, C., Frittelli, M., Levi, F., Mura, A., Maccaferri, G., Nanni, M., et al. (2017) · Scientific Reports · doi:10.1038/srep40992 · Cited by 123
(2017) · doi:10.1103/physrevlett.118.053002 · Cited by 102
A compact, transportable single-ion optical clock with 7.8 × 10−17 systematic uncertainty
Cao, J., Zhang, P., Shang, J., Cui, K., Yuan, J., Chao, S., Wang, S., Shu, H., & Huang, X. (2017) · Applied Physics B · doi:10.1007/s00340-017-6671-5 · Cited by 101 · cited 5×
“+ transportable clock project is the most advanced, with a demonstrated fractional systematic uncertainty below 10 16 in a 0.54 m3 volume (excluding 15 Figure 5. Transportable Ca+ clock at WIPM (from (7)). Left: pictures of the ion trap, laser sources and detection sub-module (a), laser-stabilization cavity (b), ultra…”
BackgroundMethodInfluentialCascaded optical fiber link using the internet network for remote clocks comparison
Chiodo, N., Quintin, N., Stefani, F., Wiotte, F., Camisard, E., Chardonnet, C., Santarelli, G., Amy-Klein, A., Pottie, P.-E., & Lopez, O. (2015) · Optics Express · doi:10.1364/oe.23.033927 · Cited by 100
Cs-based optical frequency measurement using cross-linked optical and microwave oscillators
Tamm, C., Huntemann, N., Lipphardt, B., Gerginov, V., Nemitz, N., Kazda, M., Weyers, S., & Peik, E. (2014) · Physical Review A · doi:10.1103/physreva.89.023820 · Cited by 72
Determination of a high spatial resolution geopotential model using atomic clock comparisons
Lion, G., Panet, I., Wolf, P., Guerlin, C., Bize, S., & Delva, P. (2017) · Journal of Geodesy · doi:10.1007/s00190-016-0986-6 · Cited by 66 · cited 1×
“onal metrology laboratories have been measured accurately (23, 32{34), but mobile atomic clocks are aimed to play a key role in the determination of the geopotential with increased spatial resolution (28, 35). The rst on-eld chronometric leveling measurement campaign using a transportable lattice clock has been report…”
ResultAtomic clocks: new prospects in metrology and geodesy
Delva, P., & Lodewyck, J. (2013) · arXiv · doi:10.48550/arxiv.1308.6766 · Cited by 40
Frequency Comparison of $^{171}{\text {Yb}}^+$ Ion Optical Clocks at PTB and NPL via GPS PPP
Leute, J., Huntemann, N., Lipphardt, B., Tamm, C., Nisbet-Jones, P. B. R., King, S. A., Godun, R. M., Jones, J. M., Margolis, H. S., Whibberley, P. B., et al. (2016) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2016.2524988 · Cited by 29
Cited by
Frequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
Integrated multi-wavelength control of an ion qubit
Niffenegger, R. J., Stuart, J., Sorace-Agaskar, C., Kharas, D., Bramhavar, S., Bruzewicz, C. D., Loh, W., Maxson, R. T., McConnell, R., Reens, D., et al. (2020) · Nature · doi:10.1038/s41586-020-2811-x · Cited by 330
Transportable optical atomic clocks for use in out-of-the-lab environments
Gellesch, M., Jones, J., Barron, R., Singh, A., Sun, Q., Bongs, K., & Singh, Y. (2020) · Advanced Optical Technologies · doi:10.1515/aot-2020-0023 · Cited by 26
Metadata
- Authors
- Delehaye, M., & Lacroûte, C.
- Venue
- Journal of Modern Optics
- Publisher
- Informa UK Limited
- Published
- 2018-03-07
- Volume
- 65
- Issue
- 5-6
- Pages
- 622-639
- ISSN
- 0950-0340 (ISSN-L)
- 1362-3044
- OpenAlex
- W2794149370
- Cited by
- 40
- References
- 41
- FWCI
- 2.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.