The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
The87Sr optical frequency standard at PTB
Open accessAbstract
With 87 Sr atoms confined in a one-dimensional optical lattice, the frequency of the optical clock transition 5s 2 1 S 0 –5s5p 3 P 0 has been determined to be 429 228 004 229 872.9(5) Hz. The transition frequency was measured with the help of a femtosecond-frequency comb against one of Physikalisch-Technische Bundesanstalt (PTB's) H-masers whose frequency was measured simultaneously by the PTB Cs-fountain clock CSF1. The Sr optical frequency standard contributes with a fractional uncertainty of 1.5 × 10 −16 to the total uncertainty. The agreement of the measured transition frequency with previous measurements at other institutes supports the status of this transition as the secondary representation of the second with the currently smallest uncertainty.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“With a lifetime of the excited clock state of about 120 s [44-46] and the light shift coefficient of about -13 Hzcm 2 W -1 [47], we estimate a negligible clock laser induced light shift of few 10 -19 .”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [46]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 580
Sr Lattice Clock at 1 × 10 –16 Fractional Uncertainty by Remote Optical Evaluation with a Ca Clock
Ludlow, A. D., Zelevinsky, T., Campbell, G. K., Blatt, S., Boyd, M. M., de Miranda, M. H. G., Martin, M. J., Thomsen, J. W., Foreman, S. M., Ye, J., et al. (2008) · Science · doi:10.1126/science.1153341 · Cited by 554
Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion
Margolis, H. S., Barwood, G. P., Huang, G., Klein, H. A., Lea, S. N., Szymaniec, K., & Gill, P. R. (2004) · Science · doi:10.1126/science.1105497 · Cited by 302
Porsev, S. G., & Derevianko, A. (2006) · Physical Review A · doi:10.1103/physreva.74.020502 · Cited by 279
Sub-Hertz Optical Frequency Comparisons between Two Trapped Yb+171 Ions
Schneider, T., Peik, E., & Tamm, C. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.230801 · Cited by 205
Nuclear spin effects in optical lattice clocks
Boyd, M. M., Zelevinsky, T., Ludlow, A. D., Blatt, S., Zanon-Willette, T., Foreman, S. M., & Ye, J. (2007) · Physical Review A · doi:10.1103/physreva.76.022510 · Cited by 186
Suppression of Collisional Shifts in a Strongly Interacting Lattice Clock
Swallows, M. D., Bishof, M., Lin, Y., Blatt, S., Martin, M. J., Rey, A. M., & Ye, J. (2011) · Science · doi:10.1126/science.1196442 · Cited by 181
High-Fidelity Transport of Trapped-Ion Qubits through anX-Junction Trap Array
Blakestad, R. B., Ospelkaus, C., VanDevender, A. P., Amini, J. M., Britton, J., Leibfried, D., & Wineland, D. J. (2009) · Physical Review Letters · doi:10.1103/physrevlett.102.153002 · Cited by 167
Uncertainty evaluation of the atomic caesium fountain CSF1 of the PTB
Weyers, S., bner, U. H., der, R. S., Tamm, C., & Bauch, A. (2001) · Metrologia · doi:10.1088/0026-1394/38/4/7 · Cited by 160
Self-citationThe absolute frequency of the87Sr optical clock transition
Campbell, G. K., Ludlow, A. D., Blatt, S., Thomsen, J. W., Martin, M. J., de Miranda, M. H. G., Zelevinsky, T., Boyd, M. M., Ye, J., Diddams, S. A., et al. (2008) · Metrologia · doi:10.1088/0026-1394/45/5/008 · Cited by 153
Cascaded multiplexed optical link on a telecommunication network for frequency dissemination
Lopez, O., Haboucha, A., Kéfélian, F., Jiang, H., Chanteau, B., Roncin, V., Chardonnet, C., Amy‐Klein, A., & Santarelli, G. (2010) · Optics Express · doi:10.1364/oe.18.016849 · Cited by 143
Lattice-Induced Frequency Shifts in Sr Optical Lattice Clocks at the 10−17 Level
Westergaard, P. G., Lodewyck, J., Lorini, L., Lecallier, A., Burt, E. A., Zawada, M., Millo, J., & Lemonde, P. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.210801 · Cited by 137
Recoil-Limited Laser Cooling of Sr87 Atoms near the Fermi Temperature
Mukaiyama, T., Katori, H., Ido, T., Li, Y., & Kuwata‐Gonokami, M. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.113002 · Cited by 131
Ultra-low-noise microwave extraction from fiber-based optical frequency comb
Millo, J., Boudot, R., Lours, M., Bourgeois, P. Y., Luiten, A. N., Coq, Y. L., Kersalé, Y., & Santarelli, G. (2009) · Optics Letters · doi:10.1364/ol.34.003707 · Cited by 125
Probing Interactions Between Ultracold Fermions
Campbell, G. K., Boyd, M. M., Thomsen, J. W., Martin, M. J., Blatt, S., Swallows, M. D., Nicholson, T., Fortier, T. M., Oates, C. W., Diddams, S. A., et al. (2009) · Science · doi:10.1126/science.1169724 · Cited by 121
Hyperpolarizability Effects in a Sr Optical Lattice Clock
Brusch, A., Targat, R. L., Baillard, X., Fouché, M., & Lemonde, P. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.103003 · Cited by 120
Calcium optical frequency standard with ultracold atoms: Approaching 10−15 relative uncertainty
Degenhardt, C., Stoehr, H., Lisdat, C., Wilpers, G., Schnatz, H., Lipphardt, B., Nazarova, T., Pottie, P.-É., Sterr, U., Helmcke, J., et al. (2005) · Physical Review A · doi:10.1103/physreva.72.062111 · Cited by 117
Self-citationOptical lattice clock with atoms confined in a shallow trap
Lemonde, P., & Wolf, P. (2005) · Physical Review A · doi:10.1103/physreva.72.033409 · Cited by 114
Measuring the frequency of a Sr optical lattice clock using a 120 km coherent optical transfer
Hong, F.-L., Musha, M., Takamoto, M., Inaba, H., Yanagimachi, S., Takamizawa, A., Watabe, K.-I., Ikegami, T., Imae, M., Fujii, Y., et al. (2009) · Optics Letters · doi:10.1364/ol.34.000692 · Cited by 113
An optical lattice clock with spin-polarized 87Sr atoms
Baillard, X., Fouché, M., Targat, R. L., Westergaard, P. G., Lecallier, A., Chapelet, F., Abgrall, M., Rovera, D., Laurent, P., Rosenbusch, P., et al. (2007) · The European Physical Journal D · doi:10.1140/epjd/e2007-00330-3 · Cited by 112
Self-citationAccuracy evaluation of an optical lattice clock with bosonic atoms
Baillard, X., Fouché, M., Le Targat, R., Westergaard, P. G., Lecallier, A., Le Coq, Y., Rovera, G. D., Bize, S., & Lemonde, P. (2007) · Optics Letters · doi:10.1364/ol.32.001812 · Cited by 100
Total variance, an estimator of long-term frequency stability [standards]
Greenhall, C. A., Howe, D. A., & Percival, D. B. (1999) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.796124 · Cited by 89
Collisional Losses, Decoherence, and Frequency Shifts in Optical Lattice Clocks with Bosons
Lisdat, C., Winfred, J. S. R. V., Middelmann, T., Riehle, F., & Sterr, U. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.090801 · Cited by 87
Self-citationWeyers, S., Lipphardt, B., & Schnatz, H. (2009) · Physical Review A · doi:10.1103/physreva.79.031803 · Cited by 86
Self-citationDecoherence and Collisional Frequency Shifts of Trapped Bosons and Fermions
Gibble, K. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.113202 · Cited by 79
Determination of Sr properties for a high-accuracy optical clock
Porsev, S. G., Ludlow, A. D., Boyd, M. M., & Ye, J. (2008) · Physical Review A · doi:10.1103/physreva.78.032508 · Cited by 79
Cancellation of the Collisional Frequency Shift in Caesium Fountain Clocks
Szymaniec, K., Chałupczak, W., Tiesinga, E., Williams, C. J., Weyers, S., & Wynands, R. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.153002 · Cited by 69
Self-citationTackling the Blackbody Shift in a Strontium Optical Lattice Clock
Middelmann, T., Lisdat, C., Falke, S., Winfred, J. S. R. V., Riehle, F., & Sterr, U. (2011) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2088470 · Cited by 62
Self-citationDemonstration of a transportable 1 Hz-linewidth laser
Vogt, S., Lisdat, C., Legero, T., Sterr, U., Ernsting, I., Nevsky, A. Y., & Schiller, S. (2011) · Applied Physics B · doi:10.1007/s00340-011-4652-7 · Cited by 61
Self-citationТайченачев, А. В., Yudin, V. I., Ovsiannikov, V. D., Pal'chikov, V. G., & Oates, C. W. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.193601 · Cited by 56
Many-Body Treatment of the Collisional Frequency Shift in Fermionic Atoms
Rey, A. M., Gorshkov, A. V., & Rubbo, C. P. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.260402 · Cited by 49
Three dimensional cooling and trapping with a narrow line
Chanelière, T., He, L., Kaiser, R., & Wilkowski, D. (2007) · The European Physical Journal D · doi:10.1140/epjd/e2007-00329-8 · Cited by 35
Influence of Chirped Excitation Pulses in an Optical Clock With Ultracold Calcium Atoms
Degenhardt, C., Nazarova, T., Lisdat, C., Stoehr, H., Sterr, U., & Riehle, F. (2005) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2004.843388 · Cited by 31
Self-citationRecent atomic clock comparisons at NIST
Lorini, L., Ashby, N., Brusch, A., Diddams, S. A., Drullinger, R. E., Eason, E., Fortier, T. M., Hastings, P., Heavner, T. P., Hume, D. B., et al. (2008) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2008-00807-7 · Cited by 29
Pape, A., Terra, O., Friebe, J., Riedmann, M., Wübbena, T., Rasel, E. M., Predehl, K., Legero, T., Lipphardt, B., Schnatz, H., et al. (2010) · Optics Express · doi:10.1364/oe.18.021477 · Cited by 27
Self-citationOptical frequency synthesis and measurement using fibre-based femtosecond lasers
Grosche, G., Lipphardt, B., & Schnatz, H. (2008) · The European Physical Journal D · doi:10.1140/epjd/e2008-00065-7 · Cited by 25
Self-citationCryogenic fountain development at NIST and INRIM: preliminary characterization
Levi, F., Calosso, C. E., Calonico, D., Lorini, L., Bertacco, E. K., Godone, A., Costanzo, G. A., Mongino, B., Jefferts, S. R., Heavner, T. P., et al. (2010) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1453 · Cited by 22
Interrogation Laser for a Strontium Lattice Clock
Legero, T., Lisdat, C., Winfred, J. S. R. V., Schnatz, H., Grosche, G., Riehle, F., & Sterr, U. (2008) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2008.2007042 · Cited by 19
Self-citationSpecular Spectral Reflectance Of ALS1304 Stainless Steel At Near-Normal Incidence
Namba, Y. (1983) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.934138 · Cited by 5
Rey, A. M., Gorshkov, A. V., & Rubbo, C. P. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.049901 · Cited by 1
Research works printed but not linked: 4
- 2009, Report of the 98th Meeting of the Comité International des Poids et Mesures (CIPM)
- Gill P Riehle F, 2006, Proc. 2006 Meeting of the European Frequency and Time Forum
- Weyers S Bauch A Schröder R Tamm C Gill P, 2002, Frequency Standards and Metrology, Proc. 6th Symp., 64
- 1993, Guide to the Expression of Uncertainty in Measurement ISO/TAG 4
Cited by
Sorted by citations
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Self-citationGeodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Self-citation
Metadata
- Authors
- Falke, S., Schnatz, H., Winfred, J. S. R. V., Middelmann, T., Vogt, S., Weyers, S., Lipphardt, B., Grosche, G., Riehle, F., Sterr, U., & Lisdat, C.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2011-09-12
- Volume
- 48
- Issue
- 5
- Pages
- 399-407
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2016860894
- Cited by
- 129
- References
- 43
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 9 · 2023: 4 · 2022: 2 · 2021: 3 · 2020: 11 · 2019: 6 · 2018: 9 · 2017: 4 · 2016: 9 · 2015: 11 · 2014: 16 · 2013: 19 · 2012: 19
- FWCI
- 9.55
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Metrologia (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- strontium-87, optical frequency standard, optical clock transition, one-dimensional optical lattice, femtosecond optical frequency comb, cesium fountain clock, atomic clocks
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review