The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
The87Sr optical frequency standard at PTB
Open accessAbstract
With 87 Sr atoms confined in a one-dimensional optical lattice, the frequency of the optical clock transition 5s 2 1 S 0 –5s5p 3 P 0 has been determined to be 429 228 004 229 872.9(5) Hz. The transition frequency was measured with the help of a femtosecond-frequency comb against one of Physikalisch-Technische Bundesanstalt (PTB's) H-masers whose frequency was measured simultaneously by the PTB Cs-fountain clock CSF1. The Sr optical frequency standard contributes with a fractional uncertainty of 1.5 × 10 −16 to the total uncertainty. The agreement of the measured transition frequency with previous measurements at other institutes supports the status of this transition as the secondary representation of the second with the currently smallest uncertainty.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“With a lifetime of the excited clock state of about 120 s [44-46] and the light shift coefficient of about -13 Hzcm 2 W -1 [47], we estimate a negligible clock laser induced light shift of few 10 -19 .”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [46]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 580
Sr Lattice Clock at 1 × 10 –16 Fractional Uncertainty by Remote Optical Evaluation with a Ca Clock
Ludlow, A. D., Zelevinsky, T., Campbell, G. K., Blatt, S., Boyd, M. M., de Miranda, M. H. G., Martin, M. J., Thomsen, J. W., Foreman, S. M., Ye, J., et al. (2008) · Science · doi:10.1126/science.1153341 · Cited by 554
Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion
Margolis, H. S., Barwood, G. P., Huang, G., Klein, H. A., Lea, S. N., Szymaniec, K., & Gill, P. R. (2004) · Science · doi:10.1126/science.1105497 · Cited by 302
Porsev, S. G., & Derevianko, A. (2006) · Physical Review A · doi:10.1103/physreva.74.020502 · Cited by 279
Sub-Hertz Optical Frequency Comparisons between Two Trapped Yb+171 Ions
Schneider, T., Peik, E., & Tamm, C. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.230801 · Cited by 205
Nuclear spin effects in optical lattice clocks
Boyd, M. M., Zelevinsky, T., Ludlow, A. D., Blatt, S., Zanon-Willette, T., Foreman, S. M., & Ye, J. (2007) · Physical Review A · doi:10.1103/physreva.76.022510 · Cited by 186
Suppression of Collisional Shifts in a Strongly Interacting Lattice Clock
Swallows, M. D., Bishof, M., Lin, Y., Blatt, S., Martin, M. J., Rey, A. M., & Ye, J. (2011) · Science · doi:10.1126/science.1196442 · Cited by 181
Research works printed but not linked: 4
- 2009, Report of the 98th Meeting of the Comité International des Poids et Mesures (CIPM)
- Gill P Riehle F, 2006, Proc. 2006 Meeting of the European Frequency and Time Forum
- Weyers S Bauch A Schröder R Tamm C Gill P, 2002, Frequency Standards and Metrology, Proc. 6th Symp., 64
- 1993, Guide to the Expression of Uncertainty in Measurement ISO/TAG 4
Cited by
Sorted by citations
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Self-citationGeodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Self-citation
Metadata
- Authors
- Falke, S., Schnatz, H., Winfred, J. S. R. V., Middelmann, T., Vogt, S., Weyers, S., Lipphardt, B., Grosche, G., Riehle, F., Sterr, U., & Lisdat, C.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2011-09-12
- Volume
- 48
- Issue
- 5
- Pages
- 399-407
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2016860894
- Cited by
- 129
- References
- 43
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 9 · 2023: 4 · 2022: 2 · 2021: 3 · 2020: 11 · 2019: 6 · 2018: 9 · 2017: 4 · 2016: 9 · 2015: 11 · 2014: 16 · 2013: 19 · 2012: 19
- FWCI
- 9.55
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Metrologia (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- strontium-87, optical frequency standard, optical clock transition, one-dimensional optical lattice, femtosecond optical frequency comb, cesium fountain clock, atomic clocks
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review